Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic noise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Laser-Induced Cooperative Transition in Molecular Electronic Crystal

The competing and non-equilibrium phase transitions, involving dynamic tunability of cooperative electronic and magnetic states in strongly correlated materials, show great promise in quantum sensing and information technology. To date, the stabilization of transient states is still in the preliminary stage, particularly with respect to molecular electronic solids. Here, a dynamic and cooperative phase in potassium-7,7,8,8-tetracyanoquinodimethane (K-TCNQ) with the control of pulsed electromagnetic excitation is demonstrated. Simultaneous dynamic and coherent lattice perturbation with 8 ns pulsed laser (532 nm, 15 MW cm -2 , 10 Hz) in such a molecular electronic crystal initiates a stable long-lived (over 400 days) conducting paramagnetic state (≈42 Ωcm), showing the charge–spin bistability over a broad temperature range from 2 to 360 K. Comprehensive noise spectroscopy, in situ high-pressure measurements, electron spin resonance (ESR), theoretical model, and scanning tunneling microscopy/spectroscopy (STM/STS) studies provide further evidence that such a transition is cooperative, requiring a dedicated charge–spin–lattice decoupling to activate and subsequently stabilize nonequilibrium phase. Finally, the cooperativity triggered by ultrahigh-strain-rate (above 10 6 s -1 ) pulsed excitation offers a collective control toward the generation and stabilization of strongly correlated electronic and magnetic orders in molecular electronic solids and offers unique electro-magnetic phases with technological promises.

36 MATERIALS SCIENCE↗

Electron-nuclear decoupling at a spin clock transition

The ability to design quantum systems that decouple from environmental noise sources is highly desirable for development of quantum technologies with optimal coherence. The chemical tunability of electronic states in magnetic molecules combined with advanced electron spin resonance techniques provides excellent opportunities to address this problem. Indeed, so-called clock transitions have been shown to protect molecular spin qubits from magnetic noise, giving rise to significantly enhanced coherence. Here we conduct a spectroscopic and computational investigation of this physics, focusing on the role of the nuclear bath. Away from the clock transition, linear coupling to the nuclear degrees of freedom causes a modulation and decay of electronic coherence, as quantified via electron spin echo signals generated experimentally and in silico. Meanwhile, the effective hyperfine interaction vanishes at the clock transition, resulting in electron-nuclear decoupling and an absence of quantum information leakage to the nuclear bath, providing opportunities to characterize other decoherence sources.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of Advanced Avalanche Photodiodes for Water Vapor Lidar Receivers

Development of advanced differential absorption lidar (DIAL) receivers is very important to increase the accuracy of atmospheric water vapor measurements. A major component of such receivers is the optical detector. In the near-infrared wavelength range avalanche photodiodes (APD's) are the best choice for higher signal-to-noise ratio, where there are many water vapor absorption lines. In this study, characterization experiments were performed to evaluate a group of silicon-based APD's. The APD's have different structures representative of different manufacturers. The experiments include setups to calibrate these devices, as well as characterization of the effects of voltage bias and temperature on the responsivity, surface scans, noise measurements, and frequency response measurements. For each experiment, the setup, procedure, data analysis, and results are given and discussed. This research was done to choose a suitable APD detector for the development of an advanced atmospheric water vapor differential absorption lidar detection system operating either at 720, 820, or 940 nm. The results point out the benefits of using the super low ionization ratio (SLIK) structure APD for its lower noise-equivalent power, which was found to be on the order of 2 to 4 fW/Hz(sup (1/2)), with an appropriate optical system and electronics. The water vapor detection systems signal-to-noise ratio will increase by a factor of 10.

Refaat, Tamer F.↗

Up Periscope! Designing a New Perceptual Metric for Imaging System Performance

Modern electronic imaging systems include optics, sensors, sampling, noise, processing, compression, transmission and display elements, and are viewed by the human eye. Many of these elements cannot be assessed by traditional imaging system metrics such as the MTF. More complex metrics such as NVTherm do address these elements, but do so largely through parametric adjustment of an MTF-like metric. The parameters are adjusted through subjective testing of human observers identifying specific targets in a set of standard images. We have designed a new metric that is based on a model of human visual pattern classification. In contrast to previous metrics, ours simulates the human observer identifying the standard targets. One application of this metric is to quantify performance of modern electronic periscope systems on submarines.

imaging↗

Double Image Polarimeter—Ultra Fast: Simultaneous Three-color (BVR) Polarimeter with Electron-multiplying Charge-coupled Devices

We describe a new instrument capable of high-precision (10{sup −5}) polarimetric observations simultaneously in three passbands (BVR). The instrument utilizes electron-multiplying charge-coupled device (EM CCD) cameras for high efficiency and fast image readout. The key features of the Double Image Polarimeter—Ultra Fast (DIPol-UF) are: (i) the optical design with high throughput and inherent stability; (ii) great versatility, which makes the instrument optimally suitable for observations of bright and faint targets; and (iii) a control system, which allows the use of the polarimeter remotely. Examples are given of the first results obtained from high signal-to-noise observations of bright nearby stars and of fainter sources such as X-ray binaries in their quiescent states.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Brief characterization of germanium junction field effect transistors (FETs) at 77, 4, and 1.8 K

In the case of modern infrared focal planes, one of the major problems is related to the noise contribution of the cooled, impedance-matching device used as the preamplifier stage in the detector electronics system. An ideal preamp device should have the low-noise advantages of a buried-channel device and operate isothermally with the low-temperature detector array. The Ge JFET might provide this ideal device. A testing program with Ge JFETs is discussed. It is concluded that germanium JFETs offer an attractive alternative for cryogenic preamplifier designs. They operate well with high transconductance and low noise at LHe temperatures. It is believed that these devices point the way for the development of large, integrated-array, long wavelength, infrared focal planes which incorporate germanium detectors, germanium load resistors, and germanium preamplifiers within the same monolithic structure.

Arentz, R. F.↗

Electron plasma oscillations associated with type III radio emissions and solar electrons

Results of an extensive search for electron plasma oscillations associated with type III radio noise bursts are presented which were obtained by analyzing 87 type III bursts detected in plasma-wave and charged-particle measurements carried out by IMP 6, 7, and 8. Only one case is found for which plasma oscillations were associated with electrons of solar origin; at least eight events are identified in which no plasma oscillations were detected even though electrons from solar flares were clearly evident. The type III emissions are compared with similar radiation coming from upstream of earth's bow shock at the harmonic of the local electron plasma frequency, and quantitative calculations of the rate of conversion from plasma oscillatory energy to electromagnetic radiation are performed. The results show that electron plasma oscillations are seldom observed in association with solar electron events and type III radio bursts at 1.0 AU and that neither the type III emissions nor the radiation from upstream of the bow shock can be adequately explained by a current model for the coupling of electron plasma oscillations to electromagnetic radiation. Several possible explanations are considered for this discrepancy between theory and observations.

Gurnett, D. A.↗

On the measurement of hardness at high strain rates by nanoindentation impact testing

Recent advances in electronics have enabled nanomechanical measurements with very low noise, fast time constants and high data acquisition rates. Furthermore, these capabilities open the door for a wide range of ultra-fast nanomechanical testing. Given the inherent dynamic nature of high-speed testing, a thorough understanding of the testing system's dynamics and electronics is extremely important for accurate measurements. In this work, an analytical framework that includes the mechanical and electronic contributions of the instrument and the material constitutive response is presented to provide guidelines for performing high strain rate measurements of hardness by nanoindentation testing. Simple closed-form solutions that provide insights on the choice of test methodology, test parameters and instrument design are presented along with the strain rate range over which accurate measurements can be performed with the commercially available nanoindenters.

36 MATERIALS SCIENCE↗

A Discrete Component Low-Noise Preamplifier Readout for a Linear (1x16) SiC Photodiode Array

A compact, low-noise and inexpensive preamplifier circuit has been designed and fabricated to optimally readout a common cathode (1x16) channel 4H-SiC Schottky photodiode array for use in ultraviolet experiments. The readout uses an operational amplifier with 10 pF capacitor in the feedback loop in parallel with a low leakage switch for each of the channels. This circuit configuration allows for reiterative sample, integrate and reset. A sampling technique is given to remove Johnson noise, enabling a femtoampere level readout noise performance. Commercial-off-the-shelf acquisition electronics are used to digitize the preamplifier analogue signals. The data logging acquisition electronics has a different integration circuit, which allows the bandwidth and gain to be independently adjusted. Using this readout, photoresponse measurements across the array between spectral wavelengths 200 nm and 370 nm are made to establish the array pixels external quantum efficiency, current responsivity and noise equivalent power.

low-noise preamplifier↗

Signal-Induced Noise Effects in a Photon Counting System for Stratospheric Ozone Measurement

Signal-induced noise (SIN) is a common effect resulting when a photomultiplier tube (PMT) is saturated, for a brief moment, with a high intensity light pulse. After the laser pulse is sent into the atmosphere a very large light return, from either the near-field or a cloud, causes the PMT to momentarily saturate. The PMT is gated off at this time so no signal is seen at the anode. When the PMT gate is turned on, the far-field light return from the atmosphere is observed. This signal is distorted, however because of the addition of SIN to the received light signal causing a slower than expected decay of the atmospheric signal return. We have characterized SIN responses to varying parameters of the incident light on the PMT. These varied parameters included incident wavelength, PMT voltage, incident intensity, and tube type. We found that only the amplitude of the SIN was effected by varying PMT voltages and light intensities. The amplitude increased linearly as input light intensity increased. Different incident wavelengths at the same intensity did not effect the amplitude or the temporal behavior of the SIN response. Finally, different PMT tubes with similar physical structures exhibited similar SIN responses although with different amplitudes. The different amplitudes can be attributed to the different gains and operating voltages of each tube. These results suggest that SIN is caused by photocathode electron dynamics such as charge accumulation on internal PMT surfaces. These surfaces then emit the electrons slowly resulting in a long decay noise signal. With the SIN responses characterized we can now try to develop a method to reduce or eliminate SIN in DIAL systems.

Harper, David B.↗

Blocking Losses With a Photon Counter

It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

Moision, Burce E.↗

Deriving Deformable Mirror Performance Requirements in Simulation with Experimental Verification

Coronagraph instruments rely on predictable and stable deformable mirror (DM) surface displacement to achieve the contrast required to detect Earth-sized exoplanets orbiting nearby Solar-type stars. Anomalous DM behavior, such as unstable or pinned actuators, can limit contrast in coronagraphs. Simulating how these undesired behaviors affect the performance of a high contrast imaging architecture is important for developing requirements on their associated hardware. Simulating a vortex coronagraph (VC) with two deformable mirrors, this study quantifies how the number of pinned actuators affect the performance of Focal Plane Wavefront Sensing and Control algorithms using both Grid Search Electric Field Conjugation (EFC) and Planned EFC, which uses Beta-Bumping. The simulation also quantifies how various types of voltage noise such as zero-mean Gaussian noise, zero-mean periodic noise, and drift can affect the contrast of a VC during an observation run. A tolerance of a change in the Mean Normalized Intensity of ${1\times10^{-11}}$ is allocated to both types of error. If Planned EFC is used, only 1 pinned actuator on both DMs can be tolerated. If only pure Grid Search EFC is used the DMs cannot have any pinned actuators. For the case of zero-mean Gaussian noise and zero-mean periodic noise, one can tolerate a noise standard deviation of no more than ${\sigma = 0.45 \text{ mV}}$. For drift, we can only tolerate ${\sigma = 0.30 \text{ mV}}$ or less. These results show that the DM electronics and the DM themselves need to be nearly defect free to avoid having more than 1 pinned actuator. The electronics need to be tested for different types of noise statistics and that both the average and standard deviation of the noise should be measured.

Dean L. Palmer↗

High efficiency klystron for the SPS application

The enhancement of klystron efficiency through the use of collector depression, that is by recovering energy from the spent electron beam after microwave amplification, was investigated. Design considerations included noise, harmonics, cooling, and service life. The mod anode, to be employed for beam control, and the depressed collector, used in spent electron beam energy recovery, are described.

Larue, A. D.↗

Planar Doppler Velocimetry for Large-Scale Wind Tunnel Testing

Recently, Planar Doppler Velocimetry (PDV) has been shown by several laboratories to offer an attractive means for measuring three-dimensional velocity vectors everywhere in a light sheet placed in a flow. Unlike other optical means of measuring flow velocities, PDV is particularly attractive for use in large wind tunnels where distances to the sample region may be several meters, because it does not require the spatial resolution and tracking of individual scattering particles or the alignment of crossed beams at large distances. To date, demonstrations of PDV have been made either in low speed flows without quantitative comparison to other measurements, or in supersonic flows where the Doppler shift is large and its measurement is relatively insensitive to instrumental errors. Moreover, most reported applications have relied on the use of continuous-wave lasers, which limit the measurement to time-averaged velocity fields. This work summarizes the results of two previous studies of PDV in which the use of pulsed lasers to obtain instantaneous velocity vector fields is evaluated. The objective has been to quantitatively define and demonstrate PDV capabilities for applications in large-scale wind tunnels that are intended primarily for the production testing of subsonic aircraft. For such applications, the adequate resolution of low-speed flow fields requires accurate measurements of small Doppler shifts that are obtained at distances of several meters from the sample region. The use of pulsed lasers provides the unique capability to obtain not only time-averaged fields, but also their statistical fluctuation amplitudes and the spatial excursions of unsteady flow regions such as wakes and separations. To accomplish the objectives indicated, the PDV measurement process is first modeled and its performance evaluated computationally. The noise sources considered include those related to the optical and electronic properties of Charge-Coupled Device (CCD) arrays and to speckle effects associated with coherent illumination from pulsed lasers. The signal noise estimates are incorporated into the PDV signal analysis process and combined with computed scattering signals using a Mie scattering theory for polydisperse smoke particles. The relevant parameters incorporate a range of practical aerodynamic test conditions and facility sizes. The results define the optimum instrument configurations, show that the expected signal levels from a practical PDV system are sufficiently large to allow its useful application in large facilities, and show that the expected velocity measurement uncertainties are small compared to the mean velocities of interest for most subsonic, large-scale wind tunnel testing. Experimental studies using several experimental bench-top setups are then described that validate the physics of the PDV model and to calibrate its computed results. The validated model allows estimates of the uncertainties of PDV measurements and a complete definition of the PDV capabilities to be made with sufficient confidence to decide the viability of PDV for large-scale wind tunnel applications.

McKenzie, Robert L.↗

Low-frequency electrostatic instabilities excited by injections of an electron beam in space

One-dimensional particle simulations have been carried out to study the low-frequency broadband electrostatic noise that propagates almost perpendicularly from the magnetic field line when a nonrelativistic electron beam is injected into space from a spacecraft. For T(e) = T(i) the electrostatic ion cyclotron waves appear as well as the waves near the lower hybrid frequency. When the magnetic field is reduced so that Omega(e) is much less than omega(pe) in a nonisothermal plasma, T(e) greater than T(i) oblique ion acoustic instabilities appear to propagate almost perpendicular to the magnetic field. In addition, a very low frequency mode at omega much less than Omega(i) is found to be generated by the electrons flowing into the conductor. Both the injected beam electrons as well as the ambient electrons flowing into the spacecraft are responsible for generating those instabilities, which accelerate ions perpendicular to the magnetic field.

Hwang, Y. S.↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of signal to noise enhancement using a highly selective modulation tracking filter

Experiments are reported which utilize photodielectric effects in semiconductor loaded superconducting resonant circuits for suppressing noise in RF communication systems. The superconducting tunable cavity acts as a narrow band tracking filter for detecting conventional RF signals. Analytical techniques were developed which lead to prediction of signal-to-noise improvements. Progress is reported in optimization of the experimental variables. These include improved Q, new semiconductors, improved optics, and simplification of the electronics. Information bearing signals were passed through the system, and noise was introduced into the computer model.

Haden, C. R.↗