Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Mapping Electron Beam-Induced Radiolytic Damage in Molecular Crystals

Every electron crystallography experiment is fundamentally constrained by radiation damage [1]. Despite its crucial importance, little is understood about the onset and progression of radiolysis in beam-sensitive molecular crystals [2]. Since the typical metric used for monitoring the degradation induced by radiolysis is the attenuation of Bragg reflections in electron diffraction patterns [3], the scope of previous analyses [2-6] has mostly been limited to indirect observation via the back focal plane. Here, a simultaneous visualization of the effects of electron beam-induced radiolysis—in both real space and reciprocal space—remains elusive.

74 ATOMIC AND MOLECULAR PHYSICS↗

Radiolysis of Thin Water Ice in Electron Microscopy

Little is known about the radiolysis of water ice, especially as compared to the radiolysis of liquid water. In this study, the radiolytic decomposition of thin water ice films is probed for an initial 80 keV electron beam using electron energy loss spectroscopy, EELS. Pre-peaks in the oxygen K-edge spectra give the relative intensities of most of the oxygen containing species produced by radiolytic water decomposition. Contrary to expectations from the extrapolation of liquid water radiolysis data to high dose rates where significant H 2 O 2 production is expected, the main molecular product observed in the oxygen K-edge EELS spectra of water ice is O 2 . Significant mass loss of water and decomposition of most of its radiolytic products are observed for higher exposures, and the O atom seems to have a major role in the subsequent chemistry. An inverse relationship between the formation of O 2 and of ·OH is observed. A new high-dose reaction scheme is proposed. Furthermore, the significance of our results with respect to the radiolysis of water ice and for electron microscopy studies is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of coherent offset of velocity distribution in electron coolers on ion dynamics

We revisit the effect of coherent offset in velocity distribution of the electron beam in electron coolers and consider its implications for the dynamics of the cooled ion bunch. This effect becomes of special importance for high-energy electron coolers due to reduction of transverse angular spread with energy, thus requiring strict control. As an example, estimates of the severity of and the possibility to observe the considered effects for LEReC case are discussed.

43 PARTICLE ACCELERATORS↗

Building better electron sources with graphene

This report is a press release and discusses how "Graphene substrates can be reused repeatedly for photocathodes that emit high brightness electron beams in electron microscopes and accelerators."

36 MATERIALS SCIENCE↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

Measurement of the EMC Effect of the Helium-3 Nucleus at Jefferson Lab

The MARATHON (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A=3 EMC Effect in Deep Inelastic Scattering Off the Tritium and Helium MirrOr Nuclei) experiment ran in the Hall A Facility of the Thomas Jefferson National Accelerator Facility (JLab). The experiment used a 10.59 GeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) of JLab to measure the ratio of the F2 structure functions of Helium-3 and Deuterium. Data were taken in the kinematic range of 0.195 lte x lte 0.825, 2.5 (GeV/c)2 lte Q2 lte 13 (GeV/c)2, and 3.5 (GeV/c2)^2 lte W^2 lte 13 (GeV/c2)^2. This is the first measurement of the 3He EMC effect that is purely in the Deep Inelastic Scattering region. The results of this experiment constitute an important, complimentary addition, to the limited data presently available for the EMC effect of light nuclei. The MARATHON results are compared to the world data for light, medium, and heavy nuclei. This measurement is considered an essential component to uncovering the nature of the EMC effect.

Hague, Tyler↗

DESIGNING THE SPREADERS AND SPLITTERS FOR THE FFA@CEBAF ENERGY UPGRADE

The FFA@CEBAF energy upgrade study aims to approximately double the final energy of the electron beam at the Continuous Electron Beam Accelerator Facility (CEBAF). It will do this by replacing the highest-energy recirculating arcs with fixed-field alternating gradient (FFA) arcs, allowing for several more passes to circulate through the machine. This upgrade necessitates the re-design of the vertical spreader sections, which separates each pass into different recirculation arcs. Additionally, the FFA arcs will need horizontal splitter lines to correct for time of flight and R56. This work will present the current state of the spreader re-design and splitter design.

Benesch, J.↗

Optimization of DARHT Axis 1 Injector Voltage

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injector electron beam energy. The technique for time resolved measurement of the electron beam energy using electron Permanent Magnet Spectrometer (ePMSpec) has been developed. The electron energy then is used to infer the voltage produced by the injector pulsed power. The injector pulsed power of DARHT I consists of a 1.5-MV, glycol-insulated Blumlein that is pulsecharged by a step-up transformer and switched by four, laser-triggered spark gaps. A series of increasing impedance transmission lines are used to transform the output voltage of the Blumlein to a maximum of 3.8MV at the diode. Figure 1a shows a graphic of the Axis-1 prime power tank, Blumlein and downstream transmission lines. The injector pulse power is designed to produce voltage on a velvet cathode located in the vacuum vessel. The specifications of the voltage-pulse flat-top over 60ns is +/-1%. A key element in the high-voltage circuit is the ethylene glycol Blumlein. The outer volume, adjacent to the laser triggered switches of the Blumlein, is a peaking capacitor. This is an independent volume that contains a mixture of ethylene glycol and water to make it an adjustable capacitor of 380 to 750 pF.

43 PARTICLE ACCELERATORS↗

Long lifetime of bialkali photocathodes operating in high gradient superconducting radio frequency gun

Abstract High brightness, high charge electron beams are critical for a number of advanced accelerator applications. The initial emittance of the electron beam, which is determined by the mean transverse energy (MTE) and laser spot size, is one of the most important parameters determining the beam quality. The bialkali photocathodes illuminated by a visible laser have the advantages of high quantum efficiency (QE) and low MTE. Furthermore, Superconducting Radio Frequency (SRF) guns can operate in the continuous wave (CW) mode at high accelerating gradients, e.g. with significant reduction of the laser spot size at the photocathode. Combining the bialkali photocathode with the SRF gun enables generation of high charge, high brightness, and possibly high average current electron beams. However, integrating the high QE semiconductor photocathode into the SRF guns has been challenging. In this article, we report on the development of bialkali photocathodes for successful operation in the SRF gun with months-long lifetime while delivering CW beams with nano-coulomb charge per bunch. This achievement opens a new era for high charge, high brightness CW electron beams.

43 PARTICLE ACCELERATORS↗

Photoinjector Generation of High-Charge Magnetized Beams for Electron-Cooling Applications

The recently announced Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will collide high-energy ion-beams and electron beams to pursue nuclear physics research on quark-gluon plasma's. The facility performances (luminosity) would be improved if the ion-beam emittance degradation is mitigated via a phase-space-cooling technique. One potential cooling method uses a bright electron beam to cool the ion beams. The cooling rate for this electron-cooling method depends on the transverse emittance of the cooling electron beam and could benefit from using a beam with significant canonical angular momentum dubbed as a magnetized beam. This research focuses on simulation and experimental generation and characterization of high charge magnetized electron beams with parameters comparable to those required for electron cooling at an electron-ion collider. The experiment uses the 50-MeV photo-injector available at the Fermilab Accelerator Science and Technology (FAST) Facility. The measurements are benchmarked against simulations.

43 PARTICLE ACCELERATORS↗

DESIGNING THE SPREADERS AND SPLITTERS FOR THE FFA@CEBAF ENERGY UPGRADE

A degrader device is being built at the CEBAF injector to degrade the electron beam phase space for machine acceptance studies. The electron beam is degraded through multiple scattering in a thin target before further transport in the injector beamline for injection into CEBAF. The degraded electron beam will approximate phase space distributions expected from a bremsstrahlung-based polarized positron source as in the PEPPo method. The effort is in broader support of the Ce+BAF positron capability that is currently under study. Two options for the degrader device are considered, and simulation results are presented.

Sy, A.↗

Etching with electron beam-generated plasmas: Selectivity versus ion energy in silicon-based films

In the ideal case, plasma-enhanced atomic layer etching enables the ability to not only remove one monolayer of material but also leave adjacent layers undamaged. This dual mandate requires fine control over the flux of species to ensure efficacy, while maintaining an often arduously low ion energy. Electron beam-generated plasmas are well-suited for etching at low ion energies as they are generally characterized by highly charged particle densities (10 10 –10 11 cm –3 ) and low electron temperatures (<1.0 eV), which provide the ability to deliver a large flux of ions whose energies are <5 eV. Raising the ion energy with substrate biasing thus enables process control over an energy range that extends down to values commensurate with the bond strength of most material systems. In this work, we discuss silicon nitride etching using pulsed, electron beam-generated plasmas produced in argon-SF6 backgrounds. We pay particular attention to the etch rates and selectivity versus oxidized silicon nitride and polycrystalline silicon as a function of ion energy from a few eV up to 50 eV. Here, we find the blanket etch rate of Si 3 N 4 to be in the range of 1 A/s, with selectivities (versus SiO 2 and poly-Si) greater than 10:1 when ion energies are below 30 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase Transformations among TiO2 Polymorphs

Polymorphs widely exist in nature and synthetic systems and are well known to determine material properties. Understanding phase transformation mechanisms among polymorphs enables the design of structures and tuning of phases to tailor material properties. However, current understanding is limited due to the lack of direct observations that track the processes and the structural evolution is not known at atomic scale. Here, integrating (semi) in situ transmission electron microscopy and density functional theory, we report atomic structural evolutions of phase transformation from anatase (A) to rutile (R), brookite (B), R-phase, and TiO. Besides the consistent paths with previous reports, we discover several unreported paths, including a [001] direction and (020) plane of anatase to [100]A and (011)R of rutile, respectively, ( , ) and , . Density functional theory analysis elucidates atomic structural evolution during the processes and over 16% of Ti-O bonds break and reform during the processes with energy barriers of ~0.7-1.0 eV per TiO2 formula unit. Under electron-beam irradiation, anatase particles transform into TiO2-R phase or TiO at high or room temperature, respectively. We also reveal the anisotropic nature of electron-beam effect, which is seldom discussed: dependence of crystallographic orientation with respect to electron-beam irradiation direction. Understanding the atomic structural evolution sheds light on interpreting and controlling TiO2 polymorphs and interface structures for various applications. The revealed electron-beam effects in our work provide guidance for in situ transmission electron microscopy studies.

Song, Miao↗

Extreme high vacuum for polarized electron sources

Nuclear physics experiments often require highly polarized electron beams to do precise measurements of the structure and size of nucleons and the nucleus, as well as for searches for physics beyond the standard model. Jefferson Lab?s electron source, with polarization near 90%, has been providing polarized electron beams for CEBAF for over two decades. Development is underway for polarized electron sources at MESA at Mainz and the Electron Ion Collider at Brookhaven National Lab, and there is potential for polarized electron beam in the future at facilities including the International Linear Collider, an electron upgrade at CERN, and the SuperKEKB collider in Japan. At Jefferson Lab there are even plans to make use of polarized electrons to make a polarized positron source for experimental nuclear physics. High polarization electron beams are generated using photoemission from strained superlattice GaAs based photocathodes, and photocathode lifetime is limited by the ionization of residual gas in the system, which is then accelerated into the photocathode. Extreme high vacuum (near 1x10-10 Pa) is required to operate the Jefferson Lab polarized electron source with an acceptable lifetime, and the upcoming projects will need various combinations of higher current, higher bunch charge and longer photocathode lifetimes. To meet the vacuum requirements for polarized electron sources, every component for a polarized electron source must be optimized, including chamber materials, pumps, bakeout procedure and the high voltage electrode geometry and processing. Each change in these components must be evaluated offline before being used in the accelerator, and effects on pressure are difficult to evaluate even using XHV-optimized hot filament ionization gauges. In fact, we do not get a final evaluation of system modifications until an electron source is built, installed and lifetime measurements are made over the course of months or years of operation. I will be discussing the evolution of vacuum in the Jefferson Lab polarized source system toward XHV pressures and discuss the characterization and limitations measured for commercially available XHV vacuum gauges. Finally, I?ll present the effect of system pressure on photocathode lifetime and highlight how XHV pressure standards can benefit the ongoing efforts to improve vacuum for the next generation of polarized electron sources.

Stutzman, Marcy↗

Measurement of the Dispersion in the CeC Beamlines

The coherent electron cooling requires to match the relativistic factors of the hadron and electron beam within 10 -4 accuracy. Initial matching is based on the energy measurement of the electron beam using solenoid with accuracy about 10 -3 (the hadron relativistic factor can be found from the revolution frequency). Further matching is done with observation of the recombination rate with fine tuning based on the cooling rate. The last two steps require change of the electron energy which is achieved by change of the linac voltage. The interaction of the hadron and electron beams is affected by the transverse overlap of two beams. To minimize the effect, we need zero dispersion in the common section. The merge of the beams a dogleg transfer line is used containing two dipoles and three quadrupoles. The zeroing of dispersion is performed by settings of the quadrupoles. We have developed two ways to measure the dispersion. In the first mostly commonly used we change both dipoles by the same value creating the mismatch between the electron energy and bending magnet. In the compensated dogleg the position in the second dipole should not change, and the trajectory angle will change by the same amount as deflecting angle but in opposite direction. Therefore, the trajectory in the common section will not change. The value of the dispersion can be calculated from the beam displacement divided by the relative chang of the dipoles’ current. The second method is based on the change of the electron beam energy using linac. This method requires electron orbit alignment with linac axis to avoid beam steering. The results are shown in Fig.1 and Fig. 2. The first figure shows the dispersion prior the correction, and the second figure after the correction.

43 PARTICLE ACCELERATORS↗

Magnetically collimated relativistic charge-neutral electron–positron beams from high-power lasers

In this work, we report the observation of charge-neutral MeV electron-positron beams from magnetically collimated laser-driven pair-production experiments. Relativistic pairs of electrons were generated from laser-solid interactions in an external 13-T mirror field. The pairs were subsequently confined, deflected or collimated depending on the particle energy and field strength, and measured by a magnetic particle spectrometer. Equal quantities of positrons and electrons were measured in the collimated beams with an energy around 13 MeV along the magnetic mirror axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimating Beam-Target Heating

At Los Alamos National Laboratory, two high-current linear induction accelerators (LIAs) are used to produce bremsstrahlung source spots for flash radiography of high-explosive driven hydrodynamic experiments at the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility. Measurements of the electron-beam current density profile are valuable for understanding the beam dynamics in order to improve the quality of the radiography source spot. A technique commonly used at DARHT is to image the profile in Cerenkov or Optical Transition Radiation (OTR) light created by the beam striking a thin target inserted into the beam line. Target materials include aluminized dielectrics and titanium foils for OTR, and fused silica wafers for Cerenkov radiation. A practical complication with this technique is heating of the target by the electron beam. If the beam density is too great, the target can be destroyed. Moreover, even if the beam density is kept low enough to be nondestructive, the beam can heat the target to a high enough temperature to desorb gas from the surface. In that case, direct impact ionization of the gas by beam electrons can partially neutralize the beam, causing it to over-focus, thereby spoiling the data, if not destroying the target. The purpose of this note is to review some of the fundamental physics of electron beam heating in order to provide some elementary guidance for design of these imaging experiments to avoid overheating the target. Some specific examples for materials that we often use for imaging targets and beam-target experiments are provided.

43 PARTICLE ACCELERATORS↗

Toward fully automated UED operation using two-stage machine learning model

To demonstrate the feasibility of automating UED operation and diagnosing the machine performance in real time, a two-stage machine learning (ML) model based on self-consistent start-to-end simulations has been implemented. This model will not only provide the machine parameters with adequate precision, toward the full automation of the UED instrument, but also make real-time electron beam information available as single-shot nondestructive diagnostics. Furthermore, based on a deep understanding of the root connection between the electron beam properties and the features of Bragg-diffraction patterns, we have applied the hidden symmetry as model constraints, successfully improving the accuracy of energy spread prediction by a factor of five and making the beam divergence prediction two times faster. The capability enabled by the global optimization via ML provides us with better opportunities for discoveries using near-parallel, bright, and ultrafast electron beams for single-shot imaging. It also enables directly visualizing the dynamics of defects and nanostructured materials, which is impossible using present electron-beam technologies.

36 MATERIALS SCIENCE↗