Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron beam accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

AN INJECTION/EXTRACTION SCENARIO FOR EMMA

EMMA is an experiment to study beam dynamics in a linear non-scaling fixed-field alternating gradient accelerator (FFAG). It accelerates an electron beam from 10 to 20 MeV kinetic energy. To optimally perform these studies, one must be able to inject the beam at any energy within the machine's energy range. Furthermore, because we wish to study the behavior of large-emittance beams in such a machine, the injection systems must be able to inject the beam anywhere within a transverse phase space ellipse with a normalized acceptance of 3 mm, and the extraction systems must be able to extract from that same ellipse. I describe a computation of kicker and septum fields to achieve all of these requirements, and discuss how this interacts with the hardware constraints.

43 PARTICLE ACCELERATORS↗

Comment on 'Field structure and electron acceleration in a laser beam of a high-order Hermite-Gaussian mode' [J. Appl. Phys. 101, 083113 (2007)]

Wang et al. [J. Appl. Phys. 101, 083113 (2007)] investigated vacuum electron acceleration by high-order Hermite-Gaussian laser beams. However, we reveal that some of their explanations for their simulation results are not reasonable. We investigate their simulation in detail and discover that the injection momentum distributions in the longitudinal and transverse directions play an important role in inducing the valley that appears in the plot of the ejection energy as a function of the injection angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strategies for mitigating the ionization-induced beam head erosion problem in an electron-beam-driven plasma wakefield accelerator

Strategies for mitigating ionization-induced beam head erosion in an electron-beam-driven plasma wakefield accelerator (PWFA) are explored when the plasma and the wake are both formed by the transverse electric field of the beam itself. Beam head erosion can occur in a preformed plasma because of a lack of focusing force from the wake at the rising edge (head) of the beam due to the finite inertia of the electrons. When the plasma is produced by field ionization from the space charge field of the beam, the head erosion is significantly exacerbated due to the gradual recession (in the beam frame) of the 100% ionization contour. Beam particles in front of the ionization front cannot be focused (guided) causing them to expand as in vacuum. When they expand, the location of the ionization front recedes such that even more beam particles are completely unguided. Eventually this process terminates the wake formation prematurely, i.e., well before the beam is depleted of its energy. Ionization-induced head erosion can be mitigated by controlling the beam parameters (emittance, charge, and energy) and/or the plasma conditions. In this paper we explore how the latter can be optimized so as to extend the beam propagation distance and thereby increase the energy gain. In particular we show that, by using a combination of the alkali atoms of the lowest practical ionization potential (Cs) for plasma formation and a precursor laser pulse to generate a narrow plasma filament in front of the beam, the head erosion rate can be dramatically reduced. Simulation results show that in the upcoming “two-bunch PWFA experiments” on the FACET facility at SLAC national accelerator laboratory the energy gain of the trailing beam can be up to 10 times larger for the given parameters when employing these techniques. Comparison of the effect of beam head erosion in preformed and ionization produced plasmas is also presented.

43 PARTICLE ACCELERATORS↗

Shielding of a hadron in a finite e-beam

The thorough study of coherent electron cooling, the modern cooling technique capable to deal with accelerators operating in the range of few TeVs, rises many interesting questions. One of them is a shielding dynamics of a hadron in an electron beam. Now this effect is computed analytically in the infinite beam approximation. Many effects are drastically different in finite and infinite plasmas. Here we propose a method to compute the dynamical shielding effect in a finite cylindrical plasma - the realistic model of an electron beam in accelerators.

43 PARTICLE ACCELERATORS↗

Electron beam dynamics in the DARHT-II linear induction accelerator

The DARHT-II linear induction accelerator (LIA) accelerates a 2-kA electron beam to more than 17 MeV. The beam pulse has a greater than 1.5-microsecond flattop region over which the electron kinetic energy is constant to within 1%. The beam dynamics are diagnosed with 21 beam-position monitors located throughout the injector, accelerator, and after the accelerator exit, where we also have beam imaging diagnostics. We discuss the tuning of the injector and accelerator, and present data for the resulting beam dynamics. We discuss the tuning procedures and other methods used to minimize beam motion, which is undesirable for its application as a bremsstrahlung source for multi-pulse radiography of exlosively driven hydrodynamic experiments. We also present beam stability measurements, which we relate to previous stability experiments at lower current and energy.

43 PARTICLE ACCELERATORS↗

Ultrafast Diagnostics for Electron Beams from Laser Plasma Accelerators

We present an overview of diagnostic techniques for measuring key parameters of electron bunches from Laser Plasma Accelerators (LPAs). The diagnostics presented here were chosen because they highlight the unique advantages (e.g. diverse forms of electromagnetic emission) and difficulties (e.g. shot-to-shot variability) associated with LPAs. Non destructiveness and high resolution (in space and time and energy) are key attributes that enable the formation of a comprehensive suite of simultaneous diagnostics which are necessary for the full characterization of the ultrashort, but highly-variable electron bunches from LPAs.

43 PARTICLE ACCELERATORS↗

Emittance growth from electron beam modulation

In linac ring colliders like MeRHIC and eRHIC a modulation of the electron bunch can lead to a modulation of the beam beam tune shift and steering errors. These modulations can lead to emittance growth. This note presents simple formulas to estimate these effects which generalize some previous results.

43 PARTICLE ACCELERATORS↗

Small scale electron linear accelerators for industrial applications

Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications

43 PARTICLE ACCELERATORS↗

Ultrashort megaelectronvolt positron beam generation based on laser-accelerated electrons

Experimental generation of ultrashort MeV positron beams with high intensity and high density using a compact laser-driven setup is reported. A high-density gas jet is employed experimentally to generate MeV electrons with high charge; thus, a charge-neutralized MeV positron beam with high density is obtained during laser-accelerated electrons irradiating high-Z solid targets. It is a novel electron–positron source for the study of laboratory astrophysics. Meanwhile, the MeV positron beam is pulsed with an ultrashort duration of tens of femtoseconds and has a high peak intensity of 7.8 × 10{sup 21} s{sup −1}, thus allows specific studies of fast kinetics in millimeter-thick materials with a high time resolution and exhibits potential for applications in positron annihilation spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Opportunities for Bright Beam Generation at the Argonne Wakefield Accelerator (AWA)

Bright electron beams have played a critical role in many recent advances in accelerator technology. Producing bright beams via photo-emission is ultimately limited by the mean transverse energy (MTE), which is determined by the photocathode. This paper discusses the opportunity to generate bright electron beams using an upgraded version of the Argonne Wakefield Accelerator (AWA) photo-injector. The focus of this study is to examine the optimal configurations of the AWA photo-injector to produce 100 pC with a ∼100 nm transverse emittance (corresponding to a 5D brightness B5≥1015 A·m−2). The numerical optimization of the AWA photo-injector operating point, including realistic electromagnetic field maps, is presented for the different types of photocathodes under consideration.

Frame, Emily↗

Transport and Non-Invasive Position Detection of Electron Beams from Laser-Plasma Accelerators

The controlled imaging and transport of ultra-relativistic electrons from laser-plasma accelerators is of crucial importance to further use of these beams, e.g. in high peak-brightness light sources. We present our plans to realize beam transport with miniature permanent quadrupole magnets from the electron source through our THUNDER undulator. Simulation results demonstrate the importance of beam imaging by investigating the generated XUV-photon flux. In addition, first experimental findings of utilizing cavity-based monitors for non-invasive beam-position measurements in a noisy electromagnetic laser-plasma environment are discussed.

43 PARTICLE ACCELERATORS↗

Large dynamic range diagnostics for high current electron LINACs

The Jefferson Lab FEL driver accelerator - Energy Recovery Linac has provided a beam with average current of up to 9 mA and beam energy of 135 MeV. The high power beam operations have allowed developing and testing methods and approaches required to set up and tune such a facility simultaneously for the high beam power and high beam quality required for high performance FEL operations. In this contribution we briefly review this experience and outline problems that are specific to high current - high power non-equilibrium linac beams. While the original strategy for beam diagnostics and tuning have proven to be quite successful, some shortcomings and unresolved issues were also observed. The most important issues are the non-equilibrium (non-Gaussian) nature of the linac beam and the presence of small intensity - large amplitude fraction of the beam a.k.a. beam halo. Thus we also present a list of the possible beam halo sources and discuss possible mitigations means. We argue that for proper understanding and management of the beam halo large dynamic range (>10{sup 6}) transverse and longitudinal beam diagnostics can be used. We also present results of transverse beam profile measurements with the dynamic range approaching 10{sup 5} and demonstrate the effect the increased dynamic range has on the beam characterization, i.e., emittance and Twiss parameters measurements. We also discuss near future work planned in this field and where the JLab FEL facility will be used for beam tests of the developed of new diagnostics.

43 PARTICLE ACCELERATORS↗

Observation of optical transition radiation from electron beams generated by laser plasma accelerator

Laser plasma accelerators (LPAs) have made great progress, achieving electron beam with energy up to 1 GeV from a centimeter scale capillary plasma waveguide. Here in this work, we report the measurement of optical transition radiation (OTR) from the capillary-based LPA electron beams. Transition radiation images, produced by electrons passing through two separate foils (located at 2.3 m and 3.8 m away from the exit of the LPA) were recorded with a high resolution imaging system, respectively. Two magnetic quadrupole lenses were placed right after the capillary to focus and collimate the electron beams. Lastly, significant localized spikes appeared in the OTR images when the electron beam was focused by the magnetic quadrupole lenses, indicating the coherence of the radiation and the existence of ultrashort longitudinal structures inside the electron beam.

43 PARTICLE ACCELERATORS↗

Analysis of Capillary Guided Laser Plasma Accelerator Experiments at LBNL

Laser wakefield acceleration experiments were carried out by using a hydrogen-filledcapillary discharge waveguide. For a 15 mm long, 200 mu m diameter capillary, quasi-monoenergetic e-beams up to 300 MeV were observed. By de-tuning discharge delay from optimum guiding performance, self-trapping was found to be stabilized. For a 33 mm long, 300 mu m capillary, a parameter regime with high energy electron beams, up to 1 GeV, was found. In this regime, the electron beam peak energy was correlated with the amount of trapped electrons.

43 PARTICLE ACCELERATORS↗

Absolute energy calibration for relativistic electron beams with pointing instability from a laser-plasma accelerator

The pointing instability of energetic electron beams generated from a laser-driven accelerator can cause a serious error in measuring the electron spectrum with a magnetic spectrometer. In order to determine a correct electron spectrum, the pointing angle of an electron beam incident on the spectrometer should be exactly defined. Here, we present a method for absolutely calibrating the electron spectrum by monitoring the pointing angle using a scintillating screen installed in front of a permanent dipole magnet. The ambiguous electron energy due to the pointing instability is corrected by the numerical and analytical calculations based on the relativistic equation of electron motion. It is also possible to estimate the energy spread of the electron beam and determine the energy resolution of the spectrometer using the beam divergence angle that is simultaneously measured on the screen. The calibration method with direct measurement of the spatial profile of an incident electron beam has a simple experimental layout and presents the full range of spatial and spectral information of the electron beams with energies of multi-hundred MeV level, despite the limited energy resolution of the simple electron spectrometer.

43 PARTICLE ACCELERATORS↗

Simulation of a Next Generation Plasma Accelerator

Supercomputer simulations of plasma-based accelerators typically use a “moving window” to restrict the simulation area to a “small” region of interest that encompasses the laser beam and the portion of wakefield that accelerates the electron beam. In this simulation, a laser beam (red and blue disks) propagating through an under-dense plasma displaces electrons, creating a wake that supports very high electric fields, or “wakefield” (pale blue and yellow), that can be used to accelerate a short electron beam (white) to high-energy over a very short distance. While the simulation box is spatially much smaller, the number of time steps that are required to simulate the crossing of the laser through the plasma is still very large, typically over a million. (Credit: Jean-Luc Vay/Berkeley Lab)

43 PARTICLE ACCELERATORS↗

Artificial stimulation of auroral electron acceleration by intense field aligned currents

A cesium-doped high explosion was detonated at 165 km altitude in the auroral ionosphere during quiet conditions. An Alfven wave pulse with a 200-mV/m electric field was observed, with the peak occurring 135 ms after the explosion at a distance of about 1 km. The count rate of fixed energy 2-keV electron detectors abruptly increased at 140 ms, peaked at 415 ms, and indicated a downward field-aligned beam of accelerated electrons. An anomalously high-field aligned beam of backscattered electrons was also detected. The acceleration is interpreted as due to production of an electrostatic shock or double layer between 300 and 800 km altitude. The structure was probably formed by an instability of the intense field-aligned currents in the Alfven wave launched by the charge-separation electric field due to the explosion.

Holmgren, G.↗

Electron beam-based sources of ultrashort x-ray pulses.

A review of various methods for generation of ultrashort x-ray pulses using relativistic electron beam from conventional accelerators is presented. Both spontaneous and coherent emission of electrons is considered. The importance of the time-resolved studies of matter at picosecond (ps), femtosecond (fs), and atttosecond (as) time scales using x-rays has been widely recognized including by award of a Nobel Prize in 1999 [Zewa]. Extensive reviews of scientific drivers can be found in [BES1, BES2, BES3, Lawr, Whit]. Several laser-based techniques have been used to generate ultrashort x-ray pulses including laser-driven plasmas [Murn, Alte, Risc, Rose, Zamp], high-order harmonic generation [Schn, Rund, Wang, Arpi], and laser-driven anode sources [Ande]. In addition, ultrafast streak-camera detectors have been applied at synchrotron sources to achieve temporal resolution on the picosecond time scale [Wulf, Lind1]. In this paper, we focus on a different group of techniques that are based on the use of the relativistic electron beam produced in conventional accelerators. In the first part we review several techniques that utilize spontaneous emission of electrons and show how solitary sub-ps x-ray pulses can be obtained at existing storage ring based synchrotron light sources and linacs. In the second part we consider coherent emission of electrons in the free-electron lasers (FELs) and review several techniques for a generation of solitary sub-fs x-ray pulses. Remarkably, the x-ray pulses that can be obtained with the FELs are not only significantly shorter than the ones considered in Part 1, but also carry more photons per pulse by many orders of magnitude.

43 PARTICLE ACCELERATORS↗