The Ranicon - A resistive anode image converter

A versatile photon and charged particle imaging system is described. The Ranicon employs a microchannel electron multiplier plate to convert each detected event into a charge signal. This charge pulse is proximity-focused onto a large-area resistive anode plate equipped with pickup electrodes on its edges. Each event is located electronically by the ratios of the charges collected at the edges or by the differences of the signals' risetimes. One- or two-dimensional pictures are built up by storing events digitally (e.g., a core memory) or in analog form (e.g., a storage oscilloscope). Compact laboratory models have been constructed and tested. Operating characteristics, applications, limitations, and advantages of the Ranicon are discussed.

Lampton, M.↗

Woven-grid sealed quasi-bipolar lead-acid battery construction and fabricating method

A quasi-bipolar lead-acid battery construction includes a plurality of bipolar cells disposed in side-by-side relation to form a stack, and a pair of monoplanar plates at opposite ends of the stack, the cell stack and monopolar plates being contained within a housing of the battery. Each bipolar cell is loaded with an electrolyte and composed of a bipolar electrode plate and a pair of separator plates disposed on opposite sides of the electrode plate and peripherally sealed thereto. Each bipolar electrode plate is composed of a partition sheet and two bipolar electrode elements folded into a hairpin configuration and applied over opposite edges of the partition sheet so as to cover the opposite surfaces of the opposite halves thereof. Each bipolar electrode element is comprised of a woven grid with a hot-melt strip applied to a central longitudinal region of the grid along which the grid is folded into the hairpin configuration, and layers of negative and positive active material pastes applied to opposite halves of the grid on opposite sides of the central hot-melt strip. The grid is made up of strands of conductive and non-conductive yarns composing the respective transverse and longitudinal weaves of the grid. The conductive yarn has a multi-stranded glass core surrounded and covered by a lead sheath, whereas the non-conductive yarn has a multi-stranded glass core surrounded and covered by a thermally activated sizing.

Rippel, Wally E.↗

A 'tabletop' electrostatic ion storage ring: Mini-Ring

We report on the design, construction, and commissioning of a novel electrostatic ion storage ring of small dimensions - in the following referred to as 'Mini-Ring'. Mini-Ring consists of four horizontal parallel-plate deflectors and two conical electrostatic mirrors. Ions are injected through the two deflectors on the injection side and off axis with respect to the conical mirrors which face each other. The first injection deflector, originally at zero voltage, is switched to its set value such that the ions after one turn follow stable trajectories of lengths of roughly 30 cm. This design reduces the number of electrodes necessary to guide the ion beam through the ring in stable orbits. The six elements (deflectors and mirrors) are placed on a common grounded plate - the tabletop. Here, we present the design, ion trajectory simulations, and results of the first test experiments demonstrating the successful room-temperature operation of Mini-Ring at background pressures of 10{sup -6}-10{sup -7} mbar.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and initial operating characteristics of the 20 megawatt linear plasma accelerator facility

A 20-megawatt linear plasma accelerator facility, a steady flow, Faraday-type plasma accelerator facility for high velocity aerodynamic testing, was constructed, developed, and brought to an operational status. The accelerator has a 63.5-mm-square and 0.5-meter-long channel and utilizes nitrogen-seeded with 2 % mole fraction of cesium vapor. Modification of the original accelerator design characteristics and the improvements necessary to make the arc heater a suitable plasma source are described. The measured accelerator electrode current distribution and the electrode-wall potential distributions are given. The computed and the measured values are in good agreement. Measured pitot pressure indicates that an accelerator exit velocity of 9.2 km/sec, is obtained with 30 of the 36 electrode pairs powered and corresponds to a velocity increase to about 2 1/4 times the computed entrance velocity. The computed stagnation enthalpy at the accelerator exit is 92 MJ/kg, and the mass density corresponds to an altitude of about 58 km. The 92 MJ/kg stagnation enthalpy corresponds to a kinetic energy content at low temperature equivalent to a velocity of 13.6 km/sec.

Carter, A. F.↗

The FAST (FRC Acceleration Space Thruster) Experiment

The Field Reverse Configuration (FRC) is a magnetized plasmoid that has been developed for use in magnetic confinement fusion. Several of its properties suggest that it may also be useful as a thruster for in-space propulsion. The FRC is a compact toroid that has only poloidal field, and is characterized by a high plasma beta = (P)/(B (sup 2) /2Mu0), the ratio of plasma pressure to magnetic field pressure, so that it makes efficient use of magnetic field to confine a plasma. In an FRC thruster, plasmoids would be repetitively formed and accelerated to high velocity; velocities of = 250 km/s (Isp = 25,000s) have already been achieved in fusion experiments. The FRC is inductively formed and accelerated, and so is not subject to the problem of electrode erosion. As the plasmoid may be accelerated over an extended length, it can in principle be made very efficient. And the achievable jet powers should be scalable to the MW range. A 10 kW thruster experiment - FAST (FRC Acceleration Space Thruster) has just started at the Marshall Space Flight Center. The design of FAST and the status of construction and operation will be presented.

Martin, Adam↗

Intramolecular redox-site interplay effect on organic electrode for fast-charging and wide-temperature-range sodium-ion batteries

Organic electrode materials (OEMs) hold great promise for sodium-ion batteries (SIBs) due to their exceptional structural tunability and sustainability. However, the development of OEMs with fast redox kinetics and robust structural integrity remains challenging, especially over a wide temperature range. Herein, we propose an effective strategy to address both sluggish redox kinetics and insufficient structural stability in OEMs by constructing an intramolecular redox-site interplay effect. This effect is demonstrated by two hexaazatrinaphthylene-carboxylate isomers, namely HATN-m-COONa and HATN-o-COONa. Systematic experimental and computational results jointly reveal the intramolecular redox-site interplay effect in HATN-o-COONa decreases the rigid π-π stacking interactions and minimizes the skeleton structural distortion, offering faster redox kinetics and enhanced structural integrity in HATN-o-COONa compared to HATN-m-COONa (without intramolecular redox-site interplay effect). Consequently, HATN-o-COONa exhibits superior rate performance (258 mA h g−1 at 10 A g−1) and enhanced cycle stability (93% after 1000 cycles at 5 A g−1) compared to HATN-m-COONa. More importantly, HATN-o-COONa demonstrates exceptional wide-temperature adaptability, ranging from -40 °C (315 mA h g−1 at 0.1 A g−1) to 60 oC (343 mAh g-1 at 5 A g-1). This work establishes a promising design rationale for developing fast-charging and wide-temperature adaptable OEMs for energy storage systems.

Gao, Yawei [ORNL] (ORCID:0000000225672853)↗

Electrochemical-Reaction-Driven Interfacial Stress in a Solid-Solid Layered Architecture

Reaction-driven interfacial growth causes significant strain in layered architectures accompanied by mass transfer and moving boundaries. We present an analytical construct of the stress generated in a multilayer film, which incorporates the elastic-plastic strain of the growth layer, which suggests its strong dependence on the mechanical properties and thickness. This analytical formalism is further applied to a layered all-solid-state lithium battery architecture. This study demonstrates that mechanical stability can be enhanced by using a positive electrode material with high stiffness, porous hosts for lithium plating, and small external elastic constraints to buffer the volumetric changes in the electrode material. Furthermore, our results also reveal that small surface flaws in the solid electrolyte and high internal hydrostatic pressure can alleviate lithium dendrite growth through surface cracks.

25 ENERGY STORAGE↗

Understanding Binder–Silicon Interactions during Slurry Processing

The conformation of poly(acrylic acid) (PAA) as a function of shear during slurry processing to construct silicon-based anodes is elucidated via rheology-coupled ultra-small-angle neutron scattering (rheo-USANS). Rheo-USANS shows that PAA with encapsulated silicon exists as discrete aggregates that do not interact with one another. As a result, a well-connected matrix of silicon and carbon black dispersed in PAA does not exist; thus, the electrode is inhomogeneous. Raman mapping and X-ray photoelectron spectroscopy were used to confirm the electrode heterogeneity and further understand the cycling properties. These results are correlated to silicon surface chemistry to provide a pathway to making better electrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly active non-PGM catalysts prepared from metal organic frameworks

Finding inexpensive alternatives to platinum group metals (PGMs) is essential for reducing the cost of proton exchange membrane fuel cells (PEMFCs). Numerous materials have been investigated as potential replacements of Pt, of which the transition metal and nitrogen-doped carbon composites (TM/N x /C) prepared from iron doped zeolitic imidazolate frameworks (ZIFs) are among the most active ones in catalyzing the oxygen reduction reaction based on recent studies. In this report, we demonstrate that the catalytic activity of ZIF-based TM/N x /C composites can be substantially improved through optimization of synthesis and post-treatment processing conditions. Ultimately, oxygen reduction reaction (ORR) electrocatalytic activity must be demonstrated in membrane-electrode assemblies (MEAs) of fuel cells. The process of preparing MEAs using ZIF-based non-PGM electrocatalysts involves many additional factors which may influence the overall catalytic activity at the fuel cell level. Evaluation of parameters such as catalyst loading and perfluorosulfonic acid ionomer to catalyst ratio were optimized. Our overall efforts to optimize both the catalyst and MEA construction process have yielded impressive ORR activity when tested in a fuel cell system.

30 DIRECT ENERGY CONVERSION↗

Biomedical technology transfer: Applications of NASA science and technology

The major efforts of the Stanford Biomedical Applications Team Program at the Stanford University School of Medicine for the period from October 1, 1975 to September 31, 1976 are covered. A completed EMG biotelemetry system which monitors the physiological signals of man and animals in space related research is discussed. The results of a pilot study involving lower body negative pressure testing in cardiac patients has been completed as well as the design and construction of a new leg negative pressure unit for evaluating heart patients. This technology utilizes vacuum chambers to stress the cardiovascular system during space flight. Laboratory tests of an intracranial pressure transducer, have been conducted. Extremely stable long term data using capacative pressure sensors has lead to the order of commercially manufactured monitoring systems base. Projects involving commercialization are: flexible medical electrodes, an echocardioscope, a miniature biotelemetry system, and an on-line ventricular contour detector.

Source record↗

Design of a welded joint for robotic, on-orbit assembly of space trusses

In the future, some spacecraft will be so large that they must be assembled on-orbit. These spacecraft will be used for such tasks as manned missions to Mars or used as orbiting platforms for monitoring the Earth or observing the universe. Some large spacecraft will probably consist of planar truss structures to which will be attached special purpose, self-contained modules. The modules will most likely be taken to orbit fully outfitted and ready for use in heavy-lift launch vehicles. The truss members will also similarly be taken to orbit, but most unassembled. The truss structures will need to be assembled robotically because of the high costs and risks of extra-vehicular activities. Some missions will involve very large loads. To date, very few structures of any kind have been constructed in space. Two relatively simple trusses were assembled in the Space Shuttle bay in late 1985. Here the development of a design of a welded joint for on-orbit, robotic truss assembly is described. Mechanical joints for this application have been considered previously. Welded joints have the advantage of allowing the truss members to carry fluids for active cooling or other purposes. In addition, welded joints can be made more efficient structurally than mechanical joints. Also, welded joints require little maintenance (will not shake loose), and have no slop which would cause the structure to shudder under load reversal. The disadvantages of welded joints are that a more sophisticated assembly robot is required, weld flaws may be difficult to detect on-orbit, the welding process is hazardous, and welding introduces contamination to the environment. In addition, welded joints provide less structural damping than do mechanical joints. Welding on-orbit was first investigated aboard a Soyuz-6 mission in 1969 and then during a Skylab electron beam welding experiment in 1973. A hand held electron beam welding apparatus is currently being prepared for use on the MIR space station. Presently, Marshall Space Flight Center is evaluating processes appropriate for on-orbit welding. A low gravity environment has been found to have very minor effects on the welding processes appropriate for this application. This is based on tests run on-orbit as well as low gravity environments achieved by flying aircraft in parabolic trajectories. It appears that a modified form of gas tungsten arc welding (GTAW) will be most appropriate for welding together structures on-oribt. The process has been modified to work in a vacuum by providing gas to the arc zone by means of a hollow tungsten electrode with special shielding. A commercial tube welding head has been successfully modified for use on-orbit with a gas leakage rate of approximately 2.5 liters/min. To develop as realistic a joint as possible, a specific truss structure was selected on which to base the design. The structure considered was based on the 120 foot diameter aerobrake tetrahedral truss structure. The truss members were assumed to consist of graphite/epoxy tubes. Also, it was assumed that the nodes were constructed of 2219-T87 aluminum alloy. The magnitude of the member load assumed for design purposes was 100 kips.

Rule, William K.↗

Laser Doppler vibrometry for piezoelectric coefficient ($d_{33}$) measurements in irradiated aluminum nitride

Sensors used for experiments in advanced reactors must survive in harsh environments. Few material systems can be used to construct sensors viable for extreme conditions. Aluminum nitride (AlN) is one such material because it has high thermal stability and radiation resistance and sustains good piezoelectric and dielectric properties at high temperatures. In this work, the piezoelectric coefficient $d_{33}$ of the AlN single-crystal with thermal and irradiation damage was investigated using an indirect method with a laser Doppler vibrometer (LDV). Surface electrodes were deposited on the AlN samples, and the vibration response of the samples to an applied voltage was monitored using the LDV as a function of the excitation frequency. The $d_{33}$ estimation was based on the excitation voltage and the thickness-mode displacement extracted from the LDV measurements. Further, six AlN substrates were irradiated with 8 MeV Al 2+ at three fluences (10 15 , 10 16 , and 10 17 ions/cm 2 ) and two temperatures (300 °C and 500 °C). The $d_{33}$ for the six irradiated samples and one pristine sample were measured, and the measurement uncertainty was estimated based on five repeated tests. All samples were also measured by a commercial piezometer for comparison. The experimental results demonstrate that the piezoelectric coefficients obtained by LDV were about 0.8–1.16 pm/V lower than those obtained by the piezometer. With the compensation of the clamping effect, the corrected LDV values are similar to the piezometer results. Both show similar trends in all samples, which validates the feasibility of the proposed method for $d_{33}$ measurement. Based on the LDV results, the irradiated samples show a 12%–22% decrease in $d_{33}$ compared with the pristine samples. The samples irradiated under the same fluence at a higher temperature (500 °C) demonstrated a lower $d_{33}$ than those at 300 °C. The effect of the retro-reflective tape, sample temperature, and sample size on the $d_{33}$ measurement were also studied.

36 MATERIALS SCIENCE↗

Subauditory Speech Recognition based on EMG/EPG Signals

Sub-vocal electromyogram/electro palatogram (EMG/EPG) signal classification is demonstrated as a method for silent speech recognition. Recorded electrode signals from the larynx and sublingual areas below the jaw are noise filtered and transformed into features using complex dual quad tree wavelet transforms. Feature sets for six sub-vocally pronounced words are trained using a trust region scaled conjugate gradient neural network. Real time signals for previously unseen patterns are classified into categories suitable for primitive control of graphic objects. Feature construction, recognition accuracy and an approach for extension of the technique to a variety of real world application areas are presented.

Jorgensen, Charles↗

Carbon Nanotube Based Nanotechnology for NASA Mission Needs and Societal Applications

Carbon nanotubes (CNT) exhibit extraordinary mechanical properties and unique electronic properties and therefore, have received much attention for more than a decade now for a variety of applications ranging from nanoelectronics, composites to meeting needs in energy, environmental and other sectors. In this talk, we focus on some near term potential of CNT applications for both NASA and other Agency/societal needs. The most promising and successful application to date is a nano chem sensor at TRL 6 that uses a 16-256 sensor array in the construction of an electronic nose. Pristine, doped, functionalized and metal-loaded SWCNTs are used as conducting materials to provide chemical variation across the individual elements of the sensor array. This miniaturized sensor has been incorporated in an iPhone for homeland security applications. Gases and vapors relevant to leak detection in crew vehicles, biomedical, mining, chemical threats, industrial spills and others have been demonstrated. SWCNTs also respond to radiation exposure via a change in conductivity and therefore, a similar strategy is being pursued to construct a radiation nose to identify radiation sources (gamma, protons, neutrons, X-ray, etc.) with their energy levels. Carbon nanofibers (CNFs) grown using plasma enhanced CVD typically are vertical, individual, freestanding structures and therefore, are ideal for construction of nanoelectrodes. A nanoelectrode array (NEA) can be the basis for an affinity-based biosensor to meet the needs in applications such as lab-on-a-chip, environmental monitoring, cancer diagnostics, biothreat monitoring, water and food safety and others. A couple of demonstrations including detection of e-coli and ricin will be discussed. The NEA is also useful for implantation in the brain for deep brain stimulation and neuroengineering applications. Miniaturization of payload such as science instrumentation and power sources is critical to reduce launch costs. High current density (greater than 100 mA/per square centimeters) field emission capabilities of CNTs can be exploited for construction of electron gun for electron microscopy and X-ray tubes for spectrometers and baggage screening. A CNT pillar array configuration has been demonstrated, not only meeting the high current density needs but more importantly providing long term emitter stability. Finally, supercapacitors hold the promise to combine the high energy density of a battery with the high power density of capacitors. Traditional graphite electrodes have not delivered this promise yet. A novel design and processing approach using MWCNTs has shown a record 550 F/g capacitance along with significant device endurance. This supercapacitor is suitable for railgun launch application for NASA, powering rovers and robots, consumer electronics and future hybrid vehicles.

Li, Jing↗

Use of Sequential Injection Analysis to construct a Potentiometric Electronic Tongue: Application to the Multidetermination of Heavy Metals

An automated potentiometric electronic tongue (ET) was developed for the quantitative determination of heavy metal mixtures. The Sequential Injection Analysis (SIA) technique was used in order to automate the obtaining of input data, and the combined response was modeled by means of Artificial Neural Networks (ANN). The sensor array was formed by four sensors: two based on chalcogenide glasses Cd sensor and Cu sensor, and the rest on poly(vinyl chloride) membranes Pb sensor and Zn sensor. The Ion Selective Electrode (ISE) sensors were first characterized with respect to one and two analytes, by means of high-dimensionality calibrations, thanks to the use of the automated flow system; this characterization enabled an interference study of great practical utility. To take profit of the dynamic nature of the sensor's response, the kinetic profile of each sensor was compacted by Fast Fourier Transform (FFT) and the extracted coefficients were used as inputs for the ANN in the multidetermination applications. In order to identify the ANN which provided the best model of the electrode responses, some of the network parameters were optimized. Finally analyses were performed employing synthetic samples and water samples of the river Ebro; obtained results were compared with reference methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Layered transition metal thiophosphates /MPX3/ as photoelectrodes in photoelectrochemical cells

Layered crystals of the transition metal thiophosphates were synthesized and characterized for use as photoelectrodes in photoelectrochemical cells. Crystals incorporating tin and manganese show n-type response while those with iron and nickel show p-type response. These materials have a measured indirect bandgap of about 2.1 eV. They show ability to photoelectrolyze water in acid solutions with onset potentials which change in a Nernstian way as the PH of the solution changes. The onset potential is near zero volts versus a saturated calomel electrode at pH 2. At n-type crystals, oxygen could be evolved upon irradiation at underpotentials of 850 mV and at p-type crystals, hydrogen could be evolved at underpotentials of 400 mV, indicating a net gain in energy conversion. All crystals were unstable in basic solution. Liquid junction photovoltaic cells in iodide-triiodide acid solution using these layered materials were also constructed and found to have low efficiences.

Byvik, C. E.↗

Room Temperature Carbon Nanotube Based Sensor for Carbon Monoxide Detection

Sulfonated single-walled carbon nanotubes have been used in an integrated electrode structure forthe detection of carbon monoxide. The sensor responds to 0.5 ppm of CO in air at room temperature. All eightsensors with this material in a 32-sensor array showed good repeatability and reproducibility, with response andrecovery times of about 10 s. Pristine nanotubes generally do not respond to carbon monoxide and the resultshere confirm sulfonated nanotubes to be a potential candidate for the construction of an electronic nose thatrequires at least a few materials for the selective detection of CO.

Nanomaterial functionalization↗

Influence of substrates on photoelectrochemical performance of sprayed n-CdIn{sub 2}S{sub 4} electrodes

Cadmium indium sulphide (CdIn{sub 2}S{sub 4}) electrodes have been prepared onto the preheated fluorine doped tin oxide (FTO) coated glass and stainless steel (SS) substrates at optimized deposition conditions by using spray pyrolysis. Influence of substrates on the photoelectrochemical (PEC) performance has been carried out using cell configuration n-CdIn{sub 2}S{sub 4}/1 M (NaOH + Na{sub 2}S + S)/C for studying the current-voltage (I-V), photovoltaic output, photovoltaic rise and decay, photo and spectral responses and capacitance-voltage (C-V) characteristics. The junction ideality factor in dark (n{sub D}) and light (n{sub L}), series and shunt resistances (R{sub s} and R{sub sh}), fill factor (FF) and efficiency ({eta}) for the cell have been estimated. The measured fill factor (FF) and cell efficiency ({eta}) of the cells are found to be 0.47%, 0.38%, and 1.06%, 0.38% for FTO and SS substrates respectively. The Energy band diagram of band bending has been constructed using the physical parameters estimated from Mott-Schottky plots. Mott-Schottky plots shows the flat-band potential (V{sub fb}) of CdIn{sub 2}S{sub 4} films to be -1.15 V/SCE and -0.90 V/SCE on FTO and SS substrates respectively. (author)