Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Electrical Fault and Power Quality Detection Algorithms and Customer-Owned DERs Monitoring with a Cyber Grid Guard System and DLT

In this study, the electrical fault and power quality detection algorithms and customer-owned DERs monitoring use cases were implemented, with a Cyber Grid Guard system and DLT. Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substations, and are associated with customer-owned distributed energy resources (DERs). Data from these IEDs, such as power meters and protection relays, must be kept confidential and of high integrity. Blockchain technology has the potential to increase microgrid resilience by enhancing data sharing security. The growing use of IEDs and customer-owned renewable energy sources (DERs) may make it necessary to connect Distributed Ledger Technology (DLT) with power system applications. We implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in the loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results showed the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, power system applications for the ESGT with DERs and the CGG system will be based on executing smart contracts between electrical utilities and customer-owned DERs.

Piesciorovsky, Emilio↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

System and method for combined heat and electric power generation

A system for combined heat and electric power generation, preferably including a heat reservoir and one or more electric generators, each preferably including a heat source and an energy converter. A method for combined heat and electric power generation, preferably including activating an electric generator, deactivating the electric generator, and/or providing heat from a heat reservoir.

Lorimer, Adam↗

A Boundary Topology Optimization Approach for Lightweighting Electric Machines Inspired by Additive Manufacturing

Minimizing the mass in electric machines while maintaining superior performance has become a new requirement for the advancement of drivetrains used in wind energy and electric mobility. Topology optimization for light-weighting electric machines using traditional approaches typically explore a restricted design space allowed by standard parametrizable geometry and manufacturing, while advanced methods like cell-based density approaches suffer from a lack of robust manufacturability constraints during the optimization process. To overcome these drawbacks, we explore a grid-independent, boundary TO where the outer shape of the magnet is parameterized using Bezier curves. We conduct a design of experiments (DOE) to study the effect of different magnet shapes on machine performance by varying the control points on the Bezier curves. A machine-learning based surrogate model is constructed using the data from the DOE to quantify the relationship between the control points, air-gap torque and mass. The control points are then optimized to maximize the torque density. The approach is used for minimizing electrical steel mass in the IEA-15MW radial flux direct-drive wind turbine generator. The free-from boundary TO resulted in smooth and concise shapes that can be easily additively manufactured with upto 20-ton reduction in electrical steel mass.

additive manufacturing↗

A New Shape Optimization Approach for Lightweighting Electric Machines Inspired by Additive Manufacturing: Preprint

Minimizing the mass in electric machines while maintaining superior performance is a new requirement for the advancement of drivetrains used in wind energy and electric mobility. Topology optimization (TO) for lightweighting electric machines using traditional approaches typically explores a restricted design space allowed by standard parametrizable geometry and manufacturing, while advanced methods, such as cell-based density approaches, suffer from a lack of robust manufacturability constraints during the optimization process. To overcome these drawbacks, we explore a grid-independent, boundary TO where the outer shape of the magnet is parameterized using Bezier curves. We conduct a design of experiments (DOE) to study the effect of different magnet shapes on machine performance by varying the control points on the Bezier curves. A machine-learning-based surrogate model is constructed using the data from the DOE to quantify the relationship between the control points, air-gap torque, and mass. The control points are then optimized to maximize the torque density. The approach is used for minimizing electrical steel mass in the International Energy Agency (IEA) 15-MW radial flux direct-drive wind turbine generator. The free-form boundary TO resulted in smooth and concise shapes that can be easily additively manufactured with up to a 20-ton reduction in electrical steel mass.

additive manufacturing↗

The Modeling of the Synfuel Production Process: Process models of Fischer-Tropsch production with electricity and hydrogen provided by various scales of nuclear plants

Synthetic fuels (synfuels), also known as electro-fuels (E-fuels), are hydrocarbon fuels produced from waste CO2 streams and water electrolysis, with electricity as the primary source of energy. To achieve substantial reductions in greenhouse gas (GHG) emissions, electricity sources must release zero carbon or near-zero carbon, as is the case with solar, wind, hydro, and nuclear power. Nuclear power is one of the largest and steadiest domestic sources of clean energy in the United States. Moreover, nuclear power has the potential to produce hydrogen economically for less than $2/kg, reaching the DOE near-term target price. Thus, using nuclear power to produce synfuels has the unique potential to significantly reduce the GHG emissions of hydrocarbon fuels production and end-use applications. Fisher-Tropsch or FT fuel (a mixture of naphtha, jet fuel, and diesel) is of great interest because it is a drop-in fuel that can be blended with conventional petroleum counterparts and is compatible with existing infrastructure. By using the ASPEN Plus model, this report develops FT fuel production models on three scales, corresponding to nuclear plants with capacities of 1000 MWe, 437 Mwe, and 100 MWe, respectively. The FT model case with energy from a 437-MWe nuclear plant is used as a baseline case. This report summarizes the baseline ASPEN Plus model results with a detailed mass and energy analysis. Our modeled facility produces 507 MT/day (185,000 gal/day) of FT fuel by converting 255 MT/day of hydrogen and 1,580 MT/day of CO2. The FT fuel production energy efficiency from hydrogen and electricity energy inputs is 70% (lowerheating-value or LHV-based). Including the high-temperature electrolyzer in the system boundary, the FT fuel production LHV efficiency from electricity and thermal energy inputs is 51%, considering 39.8 kWh/kg of electricity and 6.86 kWh/kg of thermal energy use from a nuclear plant for hydrogen production. The FT production efficiency can potentially be increased by further integrating the heat exchange between nuclear plant and FT process, and this study is underway. The carbon conversion ratio in the baseline case is 99%, with process CO2 capture and recirculation and oxy-combustion using the oxygen by-product from water electrolysis. The hydrogen consumption is 1.38 kg/gal-FT fuel and the CO2 consumption is 8.56 kg/gal-FT fuel in the baseline case. With different FT production scales determined by the nuclear plant capacity, the FT model was scaled using the same operating parameters, which led to the same conversion efficiency regardless of scale. However, the different FT plant scales will impact the economics of FT fuel production; this impact will be examined in the next phase of this study.

Zang, Guiyan↗

Development of dual phase soft magnetic laminate for advanced electric machines

The development of dual phase soft magnetic laminate for advanced electric machines at General Electric is summarized, including alloy development, properties, manufacturing trials, prototype experience, potential applications, and future material development. Dual phase soft magnetic laminates provide the flexibility to tune magnetic/non-magnetic state at the desired locations, using solution nitriding treatment with protective mask/coating. This enabling material technology benefits electric machine performance by reducing flux leakage in the laminates. It also decouples the electromagnetic and mechanical design, which opens up the design space for advanced electric machines. Magnetic and mechanical properties of dual phase laminates were compared to commercial FeSi and FeCo soft magnetic laminates. Driven by the market needs for high power density and high-speed electric machines, a synchronous reluctance (SynRel) machine without PMs using dual phase soft magnetic laminates was assessed in machine electromagnetic performance as well as rotor stress analysis by finite element simulation. Successful prototype build and testing further retired manufacturing risks and advanced the technology maturity level. Future material development with higher mechanical strength, higher saturation magnetization, higher permeability, and lower loss are highly desired for ground and air transportation electrification.

Rallabandi, Vandana↗

Electrically tunable metasurfaces incorporating a phase change material

Electrically tunable metasurfaces including an array of subwavelength metasurface unit elements are presented. The unit elements include a stacked metal-insulator-metal structure within which an active phase change layer is included. A purely insulator, metal, or coexisting metal-insulator phase of the active layer can be electrically controlled to tune an amplitude and phase response of the metasurfaces. In combination with the subwavelengths dimensions of the unit elements, the phase and amplitude response can be controlled in a range from optical wavelengths to millimeter wavelength of incident light. Electrical control of the unit elements can be provided via resistive heating produced by flow of current though a top metal layer of the unit elements. Alternatively, electrical control of the unit elements can be provided via electrical field effect produced by applying a voltage differential between the top and bottom metal layers of the unit elements.

Kim, Yonghwi↗

Apparatus and method for high density detachable electrical interface

The present disclosure relates to a high density electrical interconnect apparatus for interfacing with remotely located electrical components. The apparatus may have a housing, a substrate element supported within the housing, and a plurality of independent substrate interface connect subsystems arranged in a planar grid on the substrate element. The apparatus further has a plurality of independent electrical interface connector subassemblies, each configured to be coupled to an associated subplurality of the substrate interface connect subsystems, to form a plurality of electrical communication channels with the remotely located electrical components.

Patra, Susant↗

Low Tidal Current Speed Electricity Generation for Power at an Aquaculture Farm

Aquaculture farms are often located where tidal currents speeds are strong enough to ensure the currents supply fresh nutrients but not so strong that they harm the farm infrastructure. Traditional tidal turbines have cut-in speeds of 1 m/s and cannot generate electricity at current speeds below that threshold. Current energy converters that rely on vortex induced vibration (VIV) for movement can generate electricity at current speeds below 1 m/s. Here we discuss a project where researchers from the Pacific Northwest National Laboratory (PNNL) collaborate with researchers from the University of Michigan to investigate the feasibility of using a VIV current energy converter to generate electricity at an aquaculture farm. The VIV current energy converter uses flow induced oscillations of tandem cylinders and adaptive damping to harness the maximum horizontal marine hydrokinetic (MHK) energy by mimicking fish undulations. The current energy converter will be field tested and its power output measured over a range of current speeds. In addition to working with the University of Michigan, the PNNL researchers are collaborating with the Hog Island Oyster Company to assess their electricity usage and quantify the current energy resources at their Humboldt Bay facility. The electricity usage and current resource assessment at the aquaculture farm will be compared to the power produced by VIVACE to determine the feasibility of using VIVACE for power production at the farm.

Branch, Ruth A.↗

System and method for combined heat and electric power generation

A system for combined heat and electric power generation, preferably including a heat reservoir and one or more electric generators, each preferably including a heat source and an energy converter. A method for combined heat and electric power generation, preferably including activating an electric generator, deactivating the electric generator, and/or providing heat from a heat reservoir.

Lorimer, Adam G.↗

Precise Motion Control of Hybrid Hydraulic Electric Architecture (HHEA)

Off-highway heavy-duty vehicles have been long-standing users of hydraulic systems for power transmission and control. However, traditional hydraulic systems suffer from significant energy losses which lead to increased operating costs and a larger carbon footprint due to higher CO2 emissions. Improving the efficiency of these mobile machines is crucial not only for reducing their environmental impact but also for saving billions of dollars in operating costs. Currently, the state-of-the-art Load Sensing Architecture uses throttling valves for control, which significantly reduces its efficiency and does not recuperate energy from over-running loads. Researchers have developed several architectures such as Common Pressure Rail systems, Displacement Control, STEAM, and Electrohydraulic Architecture to improve the efficiency of off-road mobile machines. However, each of these architectures has its drawbacks. To increase system efficiency and take advantage of electrification benefits, our research group has developed a novel Hybrid Hydraulic-Electric Architecture (HHEA). The HHEA can significantly improve efficiency, decrease the size of electrical components, and maintain control performance. This new architecture has the potential to revolutionize the off-highway mobile machine industry and lead to a more sustainable future. The HHEA uses a set of common pressure rails to provide the majority of power to the actuators via power-dense hydraulics and uses electric motors for precise control and power modulation. In the context of off-road mobile machines, energy savings are undoubtedly important but it is equally important to consider the machines’ ability to perform tasks with precision and accuracy according to given commands. Therefore, precise motion control is of utmost importance to maintain the utility of Hybrid Hydraulic-Electric Architecture (HHEA). The HHEA presents a unique challenge to motion control due to the discrete pressure changes that occur when the system switches between selected pressure rails. These changes are made to minimize system inefficiencies or to keep the system within the torque capability of the electric motor. Hence, it is important to solve the motion control challenges for HHEA. This thesis aims at developing an effective motion control strategy for HHEA. The dissertation presents a two-tiered control strategy for HHEA, comprising a high-level and a low-level controller. The primary responsibility of the high- level controller is to optimize energy efficiency by making informed pressure rail selections. On the other hand, the low-level controller is focused on achieving precise motion control of the HHEA, which is crucial for realizing the desired reference trajectories. To achieve this, the low-level controller utilizes a passivity-based backstepping integral controller as the nominal control, which handles the motion control between two pressure rail switches. Additionally, a separate least norm controller is utilized as a transition controller to manage motion control during pressure rail transitions. The effectiveness of the combined control strategy is demonstrated through experiments conducted on two hardware-in-the-loop testbeds. Furthermore, the HHEA is installed on the boom and stick actuators of a backhoe arm to build a Human-in-the-Loop system that a human operator can control. A real-time rail switching algorithm is developed to determine pressure rail switching based on present duty cycle information from the operator. Modifications have been made to the human-machine interface to achieve more intuitive control. Modifications include performing control in the task-oriented coordinates, incorporating pressure feedback to enhance control with physical interaction, and using velocity field control to simplify multi-degree-of-freedom tasks and to enable novice operators to perform them with reduced risk, improved efficiency, and productivity. The research in this dissertation makes significant contributions to the field of off-road mobile machine control, providing a novel and effective control strategy for the HHEA, and demonstrating the potential for simplified machine operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterizing peak electricity demand for U.S. households: an assessment of end-use loads and demand factors

Understanding household peak electricity demand is critical to evaluate the technical need for electrical infrastructure upgrades. This study characterizes peak loads for existing and new equipment using metered data from a convenience sample of 11,940 U.S. dwellings from four sources, including 911 from two sources with end-use metering. After standardized data cleaning and labeling, we derived descriptive statistics for key metrics, such as maximum demand and demand factors, and developed predictive models relating 60- to 15-min demand for the National Electrical Code (NEC). Mean 15-min maximum demand was 9.7 kW (median 9.0 kW; IQR 7.0–11.5 kW, 95% CI 9.6–9.8 kW), indicating spare capacity in 98% of homes with hypothetical 100 A panels. Maximum demand increased with floor area and number of high-demand loads. Dwelling maximum demand was driven by higher-power, longer-duration heating appliances and vehicle charging, while most user-operated appliances contributed little. Demand factors are used to account for how most devices contribute less than their rated power to maximum demand. Existing load mean demand factors (28%; median 10%; IQR 0–58%; CI 28–29%) were higher than those for new loads (21%; median 7%; IQR 0–35%; CI 20–21%), because new loads changed the timing and magnitude of maximum demand. New high-demand loads had higher than average demand factors (40–60%). Whole dwelling demand factors support the NEC's 40% assumption, but they challenge its conservative 100% treatment of new HVAC. We propose a data-driven 50% demand factor for new equipment, which would align with metered data, improve affordability, and modernize electrical codes.

Appliances↗

Disaggregating growth in future retail electricity rates

The retail rate impacts of a number of emerging trends (e.g., rapid deployment of electric vehicles and storage, transmission build-out for large-scale renewables deployment, and grid modernization) are unknown. Importantly, decision-makers are concerned about the potential future rate impacts on energy affordability and equity. We disaggregate the key drivers of retail electricity rates and assess their impacts on future rate growth considering their interactions and uncertainty. Specifically, we develop ranges of future cost growth for a generic investor-owned and vertically-integrated electric utility representing typical cost and operating characteristics. The rate driver growth rate ranges are applied in isolation and jointly to quantify the uncertainty and variability in future retail electricity rates. The results identify what rate drivers and factors may minimize and/or decrease uncertainty in retail rate growth and their linkages to industry trends.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Coupled management of electric vehicle workplace charging and office building loads

Significant building energy savings are realized through heating, ventilation, and air conditioning (HVAC) setpoint adjustment and daylighting control. Workplace charging (WPC) enables colocation of electric vehicles (EVs) with office building loads. We proposed managing energy use of workplace EV charging and the office building and determined the number of EVs that building energy savings can facilitate charging. We simulated building energy savings in typical medium offices in Chicago IL, Baltimore MD, and Houston TX, spanning three US climate regions. Considering the EV hosting capacity of the saved building energy and travel patterns of roundtrip commuting, we minimized EV charging costs under time-of-use electricity pricing. Managed WPC can reduce charging electricity bills compared to first-come, first-served charging. The ratio of EVs to chargers, the coincident period of commuters’ dwell time and lower electricity prices, and the number of EVs in the office impacted the economic benefits achieved through charging management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Statistical Analysis of Intertube Tunneling Contacts in the Macroscopic Electrical Conductivity of Carbon Nanotube Fibers

Here, this study investigates the influence of tunneling contact resistances between carbon nanotubes (CNTs) on electron transport and electrical conductivity of macroscopic carbon nanofibers (CNFs), which profoundly impacts the performance of CNT thin film electronics, CNF electron emitters and cathodes, and energy conversion and storage devices. Utilizing a self-consistent electrical contact model coupling a transmission line model with tunneling current, we calculate the contact resistances of a plethora of CNT-CNT contacts within a CNF fiber, which consists of aligned, densely packed CNTs. A statistical analysis is conducted, using Gaussian distributions to account for variations in contact lengths, tunneling gap distances, and single CNT aspect ratios, to calculate the CNT-CNT contact resistance and the overall resistance of CNT fiber. By scaling our model to a macroscopic level, our results are in good agreement with experimental measurements. Our calculation suggests that while increasing the contact overlap length diminishes individual CNT-CNT contact resistance, it could paradoxically increase macroscopic CNT fiber resistance for a given constant CNF mass density, which is due to that fact that a larger overlap length allows more CNTs to pack along an electrical conduction path per unit length, leading to more tunneling contact junctions connected in series and thus less number of parallel conduction paths within the fiber cross section. Increasing tunneling gap distance increases both individual contact and overall fiber resistance. This research provides a simple design tool for tailoring CNT fiber electrical properties to promote real-world applications using CNTs or similar low-dimensional materials.

36 MATERIALS SCIENCE↗

Electrical Switching and Imaging of Antiferromagnetic Spins in Perovskite Epitaxial Thin Films

Electrical control of antiferromagnets is essential for the field of antiferromagnetic spintronics that promises ultrafast speed and terahertz dynamics. However, the large family of complex oxide antiferromagnets such as perovskites have been largely unexplored. Here, we demonstrate electrical switching and detection of Néel vector in LaFeO 3 epitaxial thin films with an epitaxy-enabled biaxial anisotropy, of which the switching behavior is understood by comparing to magnetic field controlled spin Hall magnetoresistance measurements. The electrical switching is corroborated by imaging of antiferromagnetic domains using X-ray Magnetic Linear Dichroism Photoemission Electron Microscopy. Electrical switching of 3-nm and 10-nm LaFeO 3 films was achieved over a wide temperature range of 25 to 300 K. This work offers an attractive platform for exploration of antiferromagnetic spintronics and other emerging phenomena such as potential insulating altermagnetism.

36 MATERIALS SCIENCE↗