Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drying methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Method of producing a storage bulb for an atomic hydrogen maser

A storage bulb for an atomic hydrogen maser is produced by coating its internal surface with an emulsion containing both TFE and FEP particles. The emulsion is produced by mixing a first quantity of TFE in an aqueous dispersion with a second quantity of FEP in an aqueous dispersion, with a third quantity of distilled water. The emulsion is poured into the bulb to coat it uniformly so as to form a thin film of emulsion on the bulb's internal surface. After excess emulsion is drained out of the bulb the emulsion in the bulb is dried to remove the water and most of the aqueous matter therefrom. The remaining emulsion is then cured by heating the bulb to a temperature of at least 380 C.

Erpenbach, H.↗

A METHOD TO REDUCE BIOBURDEN IN ASTROMATERIALS CURATION FACILITIES WITHOUT INTRODUCING UNWANTED CONTAMINATION

Introduction: NASA curates its Astromaterials collections in cleanrooms that are carefully monitored for particulate, inorganic and trace metal contamination. Current sample collections are not particularly susceptible to organic contamination or biological alteration. However, new collections like those from the OSIRIS-REx and Hayabusa2 missions will have organic contamination requirements and are susceptible to biodegradation. It will be necessary sterilize or at least disinfect curation labs, as well as tools and equipment in a manner that does not introduce additional contamination and does not affect the samples 1. Current curation cleaning procedures utilize isopropyl alcohol which offers some bioburden reduction, but is not effective against spore-forming bacteria or fungal spores 2. We present a modified disinfection method that uses ultrapure hydrogen peroxide to reduce bioburden inside curation labs and glove boxes without introducing contamination or damaging curation equipment. We tested this method in the meteorite processing lab as well as on a glovebox being cleaned for use in processing ANGSA (Apollo Next Generation Sample Analysis) samples and present the results of those tests. We discuss the limitations of this method and describe potential situations in which it will not be applicable. The CDC guidelines for disinfection andsterilization in healthcare facilities discusses over 15different methods for reducing bioburden in hospitalsettings 3. The most common method, steamsterilization, is well suited to sterilizing curationprocessing tools but cannot easily be used to sterilizecleanroom surfaces or large equipment likegloveboxes. Chemical sterilization with bleach(NaOCl) is also a common strategy in healthcare andpharmaceutical settings that presents materialcompatibility issues as well as serious inorganiccontamination concerns for curation facilities.Introducing a new source of Na and Cl into curationlabs is not acceptable. Other chemical methods likeethylene oxide, formaldehyde, iodophors andquaternary ammonium compounds could introduceorganic and inorganic contamination. We chose tofocus on hydrogen peroxide because it is generallycompatible with commonly used curation materialslike stainless steel, aluminum and Teflon and becauseit decomposes to oxygen and water. The CDCguidelines for hydrogen peroxide specify using a 7.5wt% solution at 25 ̊C with a contact time of 30 minutesfor high level disinfection and 6 hours for sterilization.High level disinfection is defined as a technique thatwill kill all microorganisms except large numbers ofbacterial spores 3. Methods: We prepared a solution of 7.5 wt%hydrogen peroxide from a stock solution of ultrapure30 wt% peroxide (JT Baker) and curation gradeultrapure water. This ultrapure water is already used incuration cleaning procedures and thus is not consideredand additional source of contamination. We conducteda materials compatibility test by exposing unanodizedand anodized 6061 T6 Al alloy to the peroxide solutionfor up to six hours and periodically inspecting thesurfaces for visible defects. We used this peroxide todisinfect the floor of the meteorite processing lab andthe interior of a curation glovebox by exposing thesesurfaces to the peroxide solution for 30 min. Thesurfaces were swabbed with a dry macrofoam swabbefore (Puritan Brand 2518051PFRNDFD) and afterperoxide treatment to collect microbes present on thesurfaces. Microbes were extracted by sonication fromthe swab into 15 ml of PBS (phosphate buffered saline)and inoculated onto the following media: TSA (trypticsoy agar) BA (blood agar), R2A (Reasoners 2 agar),Potato Dextrose Agar, Saboraud Dextrose Agar andSaboraud Dextrose Agar with 0.1 mg/ mlchloramphenicol. Four TSA plates and two BA plateswere inoculated with 0.1 ml of PBS each andincubated at 35 and 37 for 48 hours. Two R2A°C°Cplates (0.1 ml of PBS each) were incubated at 25 .°CThe remaining plates were inoculated with 0.2ml ofPBS and incubated at 30 ̊C for seven days. Afterincubation bacterial and fungal isolates were countedand transferred to new plates for identification usingthe VITEK24 automated system or by sequencing aportion of the barcode gene (16S rRNA for bacteria,small subunit gene for fungi) on an ABI 3500 Sangersequencer. Negative controls consisted of swabs thatwere opened in the sampling environment andanalyzed alongside the experimental samples.Results: A 6 hour exposure to hydrogen peroxideresulted in visible pitting on un-anodized 6061 Al, butnot on anodized surfaces. No visible pitting occurredafter a 30 minute exposure. Therefore, we decided tolimit our experimental tests to 30 min. exposures. 17bacterial CFU (colony forming units) representing 4distinct organisms were isolated from the meteorite processing lab floor prior to hydrogen peroxidetreatment. We were unable culture any organisms afterperoxide treatment. In the glovebox we were able toculture three bacterial CFU representing three distinctspecies, including a spore forming bacterium prior todisinfection with peroxide. After the peroxidetreatment we were unable to culture any organisms.Routine monitoring of the meteorite processing lab andthe glovebox did not indicate any increase in unwantedinorganic contamination after these peroxidetreatments. Discussion: A 30 minute treatment with 7.5 wt%peroxide appears to be an effective method forreducing bioburden on typical cleanroom surfaces. Themethod does not introduce unwanted organic orinorganic contamination and is compatible withcommonly used curation materials like stainless steel,Teflon and anodized aluminum alloys. Special careshould be taken with un-anodized aluminum.Prolonged exposure to hydrogen peroxide can causepitting on this material. We recommend using thismethod to disinfect curation labs and equipment whenbiological alteration is a concern. This method iseffective at room temperature and cannot be used todisinfect labs and equipment where the ambienttemperature is < 0 ̊C. Astromaterials samples shouldbe removed from the area where disinfection is tooccur. Hydrogen peroxide is a powerful oxidizingagent and will react with any organic carbon present inthe sample. References: [1.] Mccubbin, F. M. et al.Sp. Sci Rev(2019) doi:10.1007/s11214-019-0615-9. [2.] Mogul, R.et al.Astrobiology 18, ast.2017.1814 (2018). [3.]Rutala, W. A. & Weber, D. J. Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. [4.] Pincus, D. H. in Encyclopedia of Rapid Microbiological Methods (2005).

A. B. Regberg↗

Practical and efficient magnetic heat pump

Method for pumping heat magnetically at room temperature is more economical than existing refrigeration systems. Method uses natural magneto-thermal effect of gadolinium metal to establish temperature gradient across length of tube. Regenerative cyclic process in which gadolinium sample is magnetized and gives off heat at one end of tube, and then is demagnetized at other end to absorb heat has established temperature gradients of 144 degrees F in experiments near room temperature. Other materials with large magnetothermal effects can be used below room temperature. Possible commercial applications include freeze-drying and food processing, cold storage, and heating and cooling of buildings, plants, and ships.

Brown, G. V.↗

High Resolution, Single-Step Patterning of Silica Aerogels

Three-dimensional metallic structures are fabricated with high spatial resolution in silica aerogels. In our method, silica hydrogels are prepared with a standard base-catalyzed route, and exchanged with an aqueous solution typically containing Ag' ions (1 M) and 2-propanol (0.2 M). The metal ions are reduced photolytically with a table-top ultraviolet lamp, or radiolytically, with a focused X-ray beam. We fabricated dots and lines as small as 30 x 70 km, protruding for several mm into the bulk of the materials. The hydrogels are eventually supercritically dried to yield aerogels, without any measurable change in the shape and spatial resolution of the lithographed structures. Transmission electron microscopy shows that illuminated regions are composed of Ag clusters with a size of several pm, separated by thin layers of silica.

Bertino, M. F.↗

Explicit Finite Element Modeling of Multilayer Composite Fabric for Gas Turbine Engine Containment Systems: Ballistic Impact Testing - Part 2

Under the Federal Aviation Administration's Airworthiness Assurance Center of Excellence and the Aircraft Catastrophic Failure Prevention Program, National Aeronautics and Space Administration Glenn Research Center collaborated with Arizona State University, Honeywell Engines, Systems and Services, and SRI International to develop improved computational models for designing fabric-based engine containment systems. In the study described in this report, ballistic impact tests were conducted on layered dry fabric rings to provide impact response data for calibrating and verifying the improved numerical models. This report provides data on projectile velocity, impact and residual energy, and fabric deformation for a number of different test conditions.

ZYLON↗

A centrifuge CO2 pellet cleaning system

An advanced turbine/CO2 pellet accelerator is being evaluated as a depaint technology at Oak Ridge National Laboratory (ORNL). The program, sponsored by Warner Robins Air Logistics Center (ALC), Robins Air Force Base, Georgia, has developed a robot-compatible apparatus that efficiently accelerates pellets of dry ice with a high-speed rotating wheel. In comparison to the more conventional compressed air 'sandblast' pellet accelerators, the turbine system can achieve higher pellet speeds, has precise speed control, and is more than ten times as efficient. A preliminary study of the apparatus as a depaint technology has been undertaken. Depaint rates of military epoxy/urethane paint systems on 2024 and 7075 aluminum panels as a function of pellet speed and throughput have been measured. In addition, methods of enhancing the strip rate by combining infra-red heat lamps with pellet blasting and by combining the use of environmentally benign solvents with the pellet blasting have also been studied. The design and operation of the apparatus will be discussed along with data obtained from the depaint studies.

Foster, C. A.↗

Packing and flow particle simulations

Granular material is present across natural and industrial processes on Earth and other planets. Granular particles show up in space exploration (lunar regolith), avalanches (boulders), food (coffee), construction (concrete powder) and manufacturing (additive manufacturing powder, battery slurries). Important phenomena emerge from large collections of granular particles. The size scales of the particles in granular material, 10 μm diameter or larger, makes particle-based simulations a tractable computational method. This seminar will present the packing and flow of granular matter using particle-based discrete element modeling simulations. Particles modeled with rotational friction only require as few as 2.6 contacts for mechanical stability, as opposed to 6 contacts for frictionless particles. Optimal parameters for in-space manufacturing particulate material are identified. Specifically, the maximum density and contacts occurs for a large-to-small particle volume ratio of 0.265. Stress and contact fabric fluctuations of flowing dry granular matter have power-law scaling with strain rate, and a kink. The pressure-dependent slope change kink could identify the transition between slower, quasistatic and faster, inertial flows.

granular↗

Packing and flow particle simulations

Granular material is present across natural and industrial processes on Earth and other planets. Granular particles show up in space exploration (lunar regolith), avalanches (boulders), food (coffee), construction (concrete powder) and manufacturing (additive manufacturing powder, battery slurries). Important phenomena emerge from large collections of granular particles. The size scales of the particles in granular material, 10 μm diameter or larger, makes particle-based simulations a tractable computational method. This seminar will present the packing and flow of granular matter using particle-based discrete element modeling simulations. Particles modeled with rotational friction only require as few as 2.6 contacts for mechanical stability, as opposed to 6 contacts for frictionless particles. Optimal parameters for in-space manufacturing particulate material are identified. Specifically, the maximum density and contacts occurs for a large-to-small particle volume ratio of 0.265. Stress and contact fabric fluctuations of flowing dry granular matter have power-law scaling with strain rate, and a kink. The pressure-dependent slope change kink could identify the transition between slower, quasistatic and faster, inertial flows.

granular↗

Method for Manufacturing Thin-film Lithium Microbatteries

A process for making thin-film batteries including the steps of cleaning a glass or silicon substrate having an amorphous oxide layer several microns thick; defining with a mask the layer shape when depositing cobalt as an adhesion layer and platinum as a current collector; using the same mask as the preceding step to sputter a layer of LiCoO2 on the structure while rocking it back and forth; heating the substrate to 300 C. for 30 minutes; sputtering with a new mask that defines the necessary electrolyte area; evaporating lithium metal anodes using an appropriate shadow mask; and, packaging the cell in a dry-room environment by applying a continuous bead of epoxy around the active cell areas and resting a glass slide over the top thereof.

Jay F Whitacre↗

Efficient Ionization Investigation for Flow Control and Energy Extraction

Nonequilibrium ionization of air by nonthermal means is explored for hypersonic vehicle applications. The method selected for evaluation generates a weakly ionized plasma using pulsed nanosecond, high-voltage discharges sustained by a lower dc voltage. These discharges promise to provide a means of energizing and sustaining electrons in the air while maintaining a nearly constant ion/neutral molecule temperature. This paper explores the use of short approx.5 nsec, high-voltage approx.12 to 22 kV, repetitive (40 to 100 kHz) discharges in generating a weakly ionized gas sustained by a 1 kV dc voltage in dry air at pressures from 10 to 80 torr. Demonstrated lifetimes of the sustainer discharge current approx.10 to 25 msec are over three orders of magnitude longer than the 5 nsec pulse that generates the electrons. This life is adequate for many high speed flows, enabling the possibility of exploiting weakly ionized plasma phenomena in flow-fields such as those in hypersonic inlets, combustors, and nozzles. Results to date are obtained in a volume of plasma between electrodes in a bell jar. The buildup and decay of the visible emission from the pulser excited air is photographed on an ICCD camera with nanosecond resolution and the time constants for visible emission decay are observed to be between 10 to 15 nsec decreasing as pressure increases. The application of the sustainer voltage does not change the visible emission decay time constant. Energy consumption as indicated by power output from the power supplies is 194 to 669 W depending on pulse repetition rate.

Schneider, Steven J.↗

Copper peroxide

A number of oxidizing agents, including chlorine, bromine, ozone and other peroxides, were allowed to act on copper solutions with the intention of forming copper peroxide. The only successful agent appears to be hydrogen peroxide. It must be used in a neutral 50 to 30 percent solution at a temperature near zero. Other methods described in the literature apparently do not work. The excess of hydrogen must be quickly sucked out of the brown precipitate, which it is best to wash with alcohol and ether. The product, crystalline under a microscope, can be analyzed only approximately. It approaches the formula CuO2H2O. In alkaline solution it appears to act catalytically in causing the decomposition of other peroxides, so that Na2O2 cannot be used to prepare it. On the addition of acids the H2O2 is regenerated. The dry substance decomposes much more slowly than the moist but is not very stable.

Moser, L.↗

Compression Behavior of Fluted-Core Composite Panels

In recent years, fiber-reinforced composites have become more accepted for aerospace applications. Specifically, during NASA s recent efforts to develop new launch vehicles, composite materials were considered and baselined for a number of structures. Because of mass and stiffness requirements, sandwich composites are often selected for many applications. However, there are a number of manufacturing and in-service concerns associated with traditional honeycomb-core sandwich composites that in certain instances may be alleviated through the use of other core materials or construction methods. Fluted-core, which consists of integral angled web members with structural radius fillers spaced between laminate face sheets, is one such construction alternative and is considered herein. Two different fluted-core designs were considered: a subscale design and a full-scale design sized for a heavy-lift-launch-vehicle interstage. In particular, axial compression of fluted-core composites was evaluated with experiments and finite-element analyses (FEA); axial compression is the primary loading condition in dry launch-vehicle barrel sections. Detailed finite-element models were developed to represent all components of the fluted-core construction, and geometrically nonlinear analyses were conducted to predict both buckling and material failures. Good agreement was obtained between test data and analyses, for both local buckling and ultimate material failure. Though the local buckling events are not catastrophic, the resulting deformations contribute to material failures. Consequently, an important observation is that the material failure loads and modes would not be captured by either linear analyses or nonlinear smeared-shell analyses. Compression-after-impact (CAI) performance of fluted core composites was also investigated by experimentally testing samples impacted with 6 ft.-lb. impact energies. It was found that such impacts reduced the ultimate load carrying capability by approximately 40% on the subscale test articles and by less than 20% on the full-scale test articles. Nondestructive inspection of the damage zones indicated that the detectable damage was limited to no more than one flute on either side of any given impact. More study is needed, but this may indicate that an inherent damage-arrest capability of fluted core could provide benefits over traditional sandwich designs in certain weight-critical applications.

Schultz, Marc R.↗

InSAR-based detection method for mapping and monitoring slow-moving landslides in remote regions with steep and mountainous terrain: An application to Nepal

Mapping and monitoring landslides in remote areas with steep and mountainous terrain is logistically challenging, expensive, and time consuming. Yet, in order to mitigate hazards and prevent loss of life in these areas, and to better understand landslide processes, high-resolution measurements of landslide activity are necessary. Satellite-based synthetic aperture radar interferometry (InSAR) provides millimeter-scale measurements of ground surface deformation that can be used to identify and monitor landslides in remote areas where ground-based monitoring techniques are not feasible. Here we present a novel InSAR deformation detection approach, which uses double difference time-series with local and regional spatial filters and pixel clustering methods to identify and monitor slow-moving landslides without making a priori assumptions of the location of landslides. We apply our analysis to freely available Copernicus Sentinel-1 satellite data acquired between 2014 and 2017 centered on the Trishuli River drainage basin in Nepal. We found a minimum of 6 slow-moving landslides that all occur within the Ranimatta lithologic formation (phyllites, metasandstones, meta basics). These landslides have areas ranging from 0.39 to 1.66 sq.km and long-term dry-season displacement rates ranging from 2.1 to 8.8 cm/yr. Due to periods of low coherence during the monsoon season (June – September) each year, and following the 25 April 2015 Mw7.8 Gorkha earthquake, our time series analysis is limited to the 2014-2015 and 2016-2017 dry seasons (September - May). We found that each of the landslides displayed slightly higher rates during the 2014 period, likely as a result of higher cumulative rainfall that fell during the 2014 monsoon season. Although we do not have high quality InSAR data to show the landslide evolution directly following the Gorkha earthquake, the similar rates of movement before (2014-2015) and after (2016-2017) Gorkha suggest the earthquake had negligible long-term impact on these landslides. Our findings highlight the potential for region-wide mapping of slow-moving l and slides using freely available remote sensing data in remote areas such as Nepal and future work will benefit from expanding our methodology to other regions around the world.

Synthetic Aperture Radar↗

Fracture Mechanics Testing of Titanium 6AL-4V in LMP-103S Propellant

Propellant tank safe-life analysis is a spacecraft propulsion subsystem Launch Range processing requirement. The material property inputs for the safe-life analysis include the stress intensity factor for environment-assisted cracking (KEAC). The KEAC for titanium alloy Ti 6Al-4V in LMP-103S propellant was determined experimentally using an innovative test method following ASTM E1681, Standard Test Method for Determining Threshold Stress Intensity Factor for Environment-Assisted Cracking of Metallic Materials. This effort was a collaboration between NASA Goddard Space Flight Center and NASA Kennedy Space Center to expose the test specimens in the propellant, while loaded in the test fixtures, for 1000- hour (42 days) at 50°C. Two test rounds have been completed to date; 1) testing mechanically loaded specimens but without propellant and 2) testing mechanically loaded specimens wetted with LMP-103S propellant. The dry test was to evaluate the crack growth without exposure to the LMP-103S propellant, and further assess the un-wetted stress intensity factor for the full 1000-hour duration. The second round of testing included the propellant soak for the requisite 1000- hour at 50°C. Current results show that the threshold intensity factor for environment-assisted cracking (exposed to LMP103S) is 22.5 ksi√in for the bulk material and 36. 2 ksi√in for the weld material. A generic ‘candidate’ tank geometry and material thickness is developed for a damage tolerance of known surface cracks below the nondestructive inspection technique detection limit. Evaluations with and without the use of a threshold intensity factor for environment-assisted cracking is performed for the required 4x propellant tank service life using the software tool NASGRO. SP2024_00239

Green propulsion↗

Open-path tunable diode laser absorption for eddy correlation flux measurements of atmospheric trace gases

Biogenic emissions from and dry deposition to terrestrial surfaces are important processes determining the trace gas composition of the atmosphere. An instrument has been developed for flux measurements of gases such as CH4, N2O, and O3 based on the eddy correlation technique which combines trace gas fluctuation measurements with simultaneous windfield measurements. The instrument combines a tunable diode laser infrared light source with an open-path multipass absorption cell in order to provide the fast time response and short base pathlength required for the eddy correlation method. Initial field tests using the instrument to measure methane emissions from a local wetland demonstrate the capability for high precision eddy correlation flux measurements.

Anderson, Stuart M.↗

Quantitative Mapping of Pore Fraction Variations in Silicon Nitride Using an Ultrasonic Contact Scan Technique

An ultrasonic scan procedure using the pulse-echo contact configuration was employed to obtain maps of pore fraction variations in sintered silicon nitride samples in terms of ultrasonic material properties. Ultrasonic velocity, attenuation coefficient, and reflection coefficient images were obtained simultaneously over a broad band of frequencies (e.g., 30 to 110 MHz) by using spectroscopic analysis. Liquid and membrane (dry) coupling techniques and longitudinal and shear-wave energies were used. The major results include the following: Ultrasonic velocity (longitudinal and shear wave) images revealed and correlated with the extent of average through-thickness pore fraction variations in the silicon nitride disks. Attenuation coefficient images revealed pore fraction nonuniformity due to the scattering that occurred at boundaries between regions of high and low pore fraction. Velocity and attenuation coefficient images were each nearly identical for machined and polished disks, making the method readily applicable to machined materials. Velocity images were similar for wet and membrane coupling. Maps of apparent Poisson's ratio constructed from longitudinal and shear-wave velocities quantified Poisson's ratio variations across a silicon nitride disk. Thermal wave images of a disk indicated transient thermal behavior variations that correlated with observed variations in pore fraction and velocity and attenuation coefficients.

Roth, Don J.↗

Additional Trials & Tribulations in Synthesizing a Sulfide Standard

Well-characterized sulfide reference materials that can serve as matrix-matched calibrants for in-situ trace element analyses via laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) remain elusive. Here, we describe the creation an in-house sulfide standard at NASA JSC that will be used to measure siderophile and chalcophile trace elements in low pressure experimental products, specifically pentlandite ([FeNi]9S8) and pyrrhotite ([FeNi]1-xS), as well as natural sulfides in terrestrial and meteoritic mineral assemblages. Recent methods in creating a homogenous sulfide standard include pressed pellets, synthesized chips, or fused glass [e.g. 1-3]. Other studies, however, have had success in forming homogenous FeS standards via synthesization methods [e.g. 4-6]. We present a variation of the method described in [4], in which we create a pyrrhotite standard doped with a variety of trace elements (Zn, As, Se, Mo, Ru, Rh, Pd, Sn, Sb, Te, W, Os, Ir, Pt, Au) at ~10-40 ppm and Cu at ~200 ppm. Sulfide compositions were constructed using Fe and Ni metal and elemental sulfur powders. Trace elements were added to elemental sulfur from Atomic Absorption Spectroscopy (AAS) elemental standards as either nitrate or chloride solutions to prevent oxidation of the metal powders. The dried sulfur mixture was mixed with Fe and Ni powders and mechanically mixed before two aliquots were placed in separate SiO2 tubes. Each tube was held under vacuum for ~30 minutes, sealed under vacuum, and then heated at 800C for 48 hours. Like [4], the synthesis products were composed of pourous sulfide crystals. Major element analyses of both experimental aliquots, collected using an Electron Probe Microanalyser (EPMA), yield indistinguishable major element compositions (uncertainties in 2SE & 2RSE[%]), with an average of 57.90  0.09 (0.16 %), 4.95  0.03 (0.55 %), and 39.70  0.14 (0.34 %), for Fe, Ni, and S, respectively. Trace element data were measured using a Photon Machines 193nm laser ablation system coupled to a Thermo-Scientific Element-XR ICP-MS. Spot sizes were limited to 50 μm due to the porous nature of the sulfide target material. Trace element abundances, normalized to Fe as an internal standard, were also found to be homogenous between the two aliquots, with weighted mean 2RSE (%) values of <3.0 for all trace elements. Synthesized products were re-powdered and absolute concentrations measured via solution ICP-MS. Although the sulfide appears to be homogenous, sintering experiments will be performed to more closely match the standard density to natural sulfides and minimize differences in ablation behavior. Improved density also allows for higher sensitivity (i.e. more compact target material) and larger spot sizes or traverses, as void space is eliminated. Additional major and trace element analyses on the products of the sintering experiments will be undertaken.

Jacob B Setera↗

A rapid method for optimization of the rocket propulsion system for single-stage-to-orbit vehicles

A rapid analytical method for the optimization of rocket propulsion systems is presented for a vertical take-off, horizontal landing, single-stage-to-orbit launch vehicle. This method utilizes trade-offs between propulsion characteristics affecting flight performance and engine system mass. The performance results from a point-mass trajectory optimization program are combined with a linearized sizing program to establish vehicle sizing trends caused by propulsion system variations. The linearized sizing technique was developed for the class of vehicle systems studied herein. The specific examples treated are the optimization of nozzle expansion ratio and lift-off thrust-to-weight ratio to achieve either minimum gross mass or minimum dry mass. Assumed propulsion system characteristics are high chamber pressure, liquid oxygen and liquid hydrogen propellants, conventional bell nozzles, and the same fixed nozzle expansion ratio for all engines on a vehicle.

Eldred, C. H.↗