Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the Reliability Test System Grid Modernization Lab Consortium (RTS-GMLC) via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Power System Recovery Coordinated with (Non-)Black-Start Generators

Power restoration is an urgent task after a black-out, and recovery efficiency is critical when quantifying system resilience. Multiple elements should be considered to restore the power system quickly and safely. This paper proposes a recovery model to solve a direct-current optimal power flow (DCOPF) based on mixed-integer linear programming (MILP). Since most of the generators cannot start independently, the interaction between black-start (BS) and non-black-start (NBS) generators must be modeled appropriately. The energization status of the NBS is coordinated with the recovery status of transmission lines, and both of them are modeled as binary variables. Also, only after an NBS unit receives the cranking power through connected transmission lines, will it be allowed to participate in the following system dispatch. The amount of cranking power is estimated as a fixed proportion to the maximum generation capacity. The proposed model is validated on several test systems, as well as a 1393-bus representation system of the Puerto Rican electric power grid. Test results demonstrate how the recovery of NBS units and damaged transmission lines can be optimized, resulting in an efficient and well-coordinated recovery procedure.

Zhao, Meng↗

Advanced Models and Fast Simulation Algorithms for MARS Plants

With the successful commercialization of modular multilevel converters (MMC) and rapid increase in photovoltaic (PV) penetration and energy storage systems (ESS), one of the research areas being explored dynamically is integration of PV systems and ESS systems to MMCs. On this front, an integrated development of PV plants, ESS, and alternating- and direct-current (ac/dc) systems through Multi-Port Autonomous Reconfigurable Solar (MARS) plant is proposed and being researched upon. However, simulation of MARS systems on traditional existing software takes very long time (order of days) due to the presence of a large number of states and non-linear devices. Therefore, development of fast high fidelity models is of paramount importance to test the hardware design, control design and planning of power system expansions. In this context, two research objectives are addressed in this paper: firstly, an ultra fast single- or multi- CPU simulation algorithm to simulate the MARS system based on state-space models, hybrid discretization algorithm with a relaxation technique that reduces the imposed computational burden and a multi-rate method is presented. Secondly, a reduced order model of MARS is also presented. Both the developed techniques are validated with respect to reference PSCAD/EMTDC model.

Marthi, Phani Ratna Vanamali↗

Dynamic Frequency Regulation Improvement in Hydropower-Hybrid System using Variational Mode Decomposition

Providing frequency response, especially fast frequency response such as Red D in the Pennsylvania-New Jersey-Maryland Interconnection (PJM) market, is challenging for many generation plants to deliver on their own. If they have adequate flexibility, hydropower plants are typically able to provide slower regulation support (e.g., Reg A in PJM), but do not respond fast enough to provide Reg D. The ability to provide Reg D would improve their revenue because this service is typically more valuable. This work presents a control approach to use hydropower, battery, and ultracapacitor systems to provide fast regulation in a way that uses the response contribution of each asset. In particular, the proposed control architecture applies a variational mode decomposition (VMD) technique on the incoming Reg D signal to extract multiple dynamic-regulation components with non-overlapping frequencies. With the response-speed dependent alignment, these regulation components are fed to the hydrogenator and hybrid energy storage system (HESS). The paper evaluates the proposed approach on a direct-current (DC)-coupled active system by computing several performance measures and analyzing sensitivity based on HESS component proportional capacities. The results reveal that the proposed VMD-based signal conditioning performs well and that optimizing the sizing of the battery and ultracapacitor components further enhances performance.

13 HYDRO ENERGY↗

Coordinated Control of Natural and Sub-Synchronous Oscillations via HVDC Links in Great Britain Power System

Conventional power oscillation damping (POD) controllers have been designed to be effective in damping either inter-area low-frequency oscillations (LFO) or sub-synchronous oscillations (SSO). For those POD controls, model-based control design method has been widely implemented with wide-area feedback signals from phasor measurement units (PMU). However, the model accuracy of a large realistic power system can hardly be guaranteed, which will finally impact the POD damping performance. In this paper, a measurement-based method is proposed for POD design using High Voltage Direct Current links (HVDC) to realize the coordinated control of both LFO and SSO. For each type of oscillations, a band-pass filter is added to avoid the interactions between different modes. Case studies are carried out on the Great Britain 36-bus power system model with multiple HVDC links in DIgSILENT/PowerFactory. Simulation results demonstrate that the proposed PODs are effective in damping inter-area LFO and SSO simultaneously.

Zhao, Yi↗

Enhancing Short-Term Flexibility through Characterization of HVDC Transmission Systems

Efficient power grid operation hinges on maintaining safety and reliability through adaptable system flexibility standards. However, in a future power grid characterized by extensive renewable energy integration, conventional system flexibility and predetermined requirements may falter under extreme conditions. This paper addresses the formidable challenge of sustaining secure and dependable power grid operations under these circumstances, emphasizing the role of controllable high voltage direct current (HVdc) transmission systems in amplifying overall system flexibility and tackling operational complexities. To quantitatively assess short-term flexibility and its associated economic benefits from HVdc within specific regions, we propose a Power Flow Distribution Factors (PTDFs) based approach. This methodology takes into account both dispatchable generators and HVdc systems, pinpointing their contributions. Through an analysis of the Western Electricity Coordinating Council (WECC) system, we demonstrate the practical application of this approach to scrutinize the impacts of existing and future HVdc lines.

Operational Flexibility, Multi-terminal HVdc, tran↗

High efficiency compact microwave sources using electrostatic potential depression

In this article, we report theoretical and design studies on the application of an electrostatic potential depression (EPD) on two types of traditional microwave sources, the klystron and the inductive output tube (IOT), both operating in the UHF band. Additionally, the EPD is implemented by a section of the metallic beam pipe on which a direct current (dc) negative high voltage is applied. Inside the EPD section, the modulated electron beam develops into bunches over a very short longitudinal distance, indicating a possible design approach for a compact device. With the application of an EPD, the peak value of the first harmonic current in a microwave tube can be further increased compared to that in a conventional design, suggesting higher circuit efficiency. As the electron beam leaves the EPD section, the reacceleration of the beam provides a longitudinal cooling effect. With the addition of an EPD, circuit power extraction efficiency above 80% is achieved in both the modified design of the IOT and the novel conceptual circuit design of the klystron.

42 ENGINEERING↗

A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.

14 SOLAR ENERGY↗

AI & Physics-Based Bad Command/Data Detection in Large Power Electronics Systems: Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS)

Detection of bad data from measurement sensors and bad commands from control centers need to be carried out to avoid instabilities within large power electronics systems. Towards the same, in this paper, model and data driven methods are proposed to identify anomalies in measured data and commands received by large power electronics systems. The large power electronics system considered in this paper is a multi-port autonomous reconfigurable solar power plant (MARS), which consists of photovoltaic (PV) and energy storage systems (ESSs) that connect to high-voltage direct current (HVdc) system and transmission ac power grid. The proposed algorithms in the MARS power plant to detect bad data from measurements and bad commands from control centers are evaluated in simulations and hardware-in-the-loop (HIL) tests. Furthermore, it has been observed that the proposed algorithms are able to detect bad measurements and commands in all the use cases evaluated.

14 SOLAR ENERGY↗

Synchronized Phasor Measurement Unit-based Central Controller for Normal and Contingent Operation of a High-Capacity HVDC Macrogrid for the Continental US

This paper presents a Synchronized Phasor Measurement Unit (PMU) based controller to support the coordination and operation of a high-capacity high-voltage direct current (HVDC) macrogrid transmission for the continental US. The proposed controller allows for optimal scheduling of each segment of the multi-terminal HVDC network under normal and contingent conditions, while considering minimum levels of frequency response requirements. The performance of the proposed controller is tested on a 100,222-bus representation of the US Eastern and Western interconnections. Results show that a centralized PMU-based controller improves the frequency nadir of the HVDC macrogrid under contingency conditions by 25.9%. Furthermore, the primary frequency response (PFR) of the HVDC macrogrid is increased by 33.4%. The performance of each interconnection under the largest credible contingency conditions is also discussed.

Mohan, Nihal↗

Renewable Integration in Hybrid ac-dc Systems using Multi-port Autonomous Reconfigurable Solar power plant (MARS)

To increase inertia and improve primary frequency response of future grids, grid-forming inverters connecting PV to grid and energy storage systems (ESSs) are likely to play an important role. Moreover, high-voltage direct current (HVdc) links will also be an enabler to transfer remote PV generation and for improved grid stability. That is, with increased penetration of PV, discrete development of PV and ESS connecting to transmission ac grid and HVdc links is one of the solutions for stable operation of grid. Here, an integrated concept for integration of PV and ESS to transmission ac grid and HVdc links is proposed that is named as multi-port autonomous reconfigurable solar power plant (MARS). The proposed integrated development reduces the cost associated with respect to discrete development of PV-ESS systems connecting to transmission ac grid and HVdc links. The integrated development incorporates advanced control methods to provide inertial and primary frequency response, reactive power support, and transient stability to manage PV and ESS resources. In this paper, high-fidelity switched system model of the integrated system and grids are developed and detailed simulation results are provided to showcase the stable operation of the integrated system and provision of grid support functions.

14 SOLAR ENERGY↗

Frequency Injection Based HVDC Attack-Defense Control Via Squeeze-Excitation Double CNN

Due to the independent controllability and fast power regulation capability, the High Voltage Direct Current (HVDC) system could be a prospective technology to provide multiple ancillary services to the system besides conventional bulk power transmission. However, with the increase of False Data Injection Attacks (FDIAs) on PMU data, the HVDC system could have the wrong response once the collected data that the HVDC system relied on is attacked, thus threatening the system operating security. How to ensure the security of the PMU-based HVDC ancillary service control become an urgent issue. To mitigate the risk, this paper proposed an HVDC attack-defense control based on the FDIAs detection method. Firstly, the Squeeze-Excitation based Double Convolutional Neural Networks (SE-DCNN) is proposed to realize fast identification of the attacking frequency type based on the time and frequency domain signals. Furthermore, the duration time of FDIAs is detected by the local outlier factor. Then, utilizing the results from SE-DCNN, HVDC ancillary service control framework is reorganized and an HVDC attack defense control is proposed for suppressing the potential influence of various types of FDIAs on the HVDC system ancillary service. Different experiments results demonstrate that the proposed method has the ability to significantly mitigate the frequency deviation and oscillation under the FDIA.

42 ENGINEERING↗

The Value of Increased HVDC Capacity Between Eastern and Western U.S. Grids: The Interconnections Seam Study

The Interconnections Seam Study examines the potential economic value of increasing electricity transfer between the Eastern and Western Interconnections using high-voltage direct-current (HVDC) transmission and cost-optimizing both generation and transmission resources across the United States, proposing, assessing, justifying, and illustrating a major infrastructure change involving two of the worlds largest power grids. The study conducted a multi-model analysis that used co-optimized generation and transmission expansion planning and production cost modeling. Four transmission designs under eight scenarios were developed and studied to estimate costs and potential benefits. The results show benefit-to-cost ratios that reach as high as 2.5, indicating significant value to increasing the transmission capacity between the interconnections under the cases considered, realized through sharing generation resources and flexibility across regions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Limitations of Fault-Tolerant Quantum Linear System Solvers for Quantum Power Flow

Quantum computers hold promise for solving problems intractable for classical computers, especially those with high time or space complexity. Practical quantum advantage can be said to exist for such problems when the end-to-end time for solving such a problem using a classical algorithm exceeds that required by a quantum algorithm. Reducing the power flow (PF) problem into a linear system of equations allows for the formulation of quantum PF (QPF) algorithms, which are based on solving methods for quantum linear systems such as the Harrow-Hassidim-Lloyd (HHL) algorithm. Speedup from using QPF algorithms is often claimed to be exponential when compared to classical PF solved by state-of-the-art algorithms. Here, we investigate the potential for practical quantum advantage in solving QPF compared to classical methods on gate-based quantum computers. Notably, this paper does not present a new QPF solving algorithm but scrutinizes the end-to-end complexity of the QPF approach, providing a nuanced evaluation of the purported quantum speedup in this problem. Our analysis establishes a best-case bound for the HHL-based quantum power flow complexity, conclusively demonstrating that the HHL-based method has higher runtime complexity compared to the classical algorithm for solving the direct current power flow (DCPF) and fast decoupled load flow (FDLF) problem. Notably, our analysis and conclusions can be extended to any quantum linear system solver with rigorous performance guarantees, based on the known complexity lower bounds for this problem. Additionally, we establish that for potential practical quantum advantage (PQA) to exist it is necessary to consider DCPF-type problems with a very narrow range of condition number values and readout requirements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Estimating Fast Charging Infrastructure Requirements to Fully Electrify Ride-Hailing Fleets Across the United States

Ride-hailing electrification is made challenging by a variety of factors, including limited driver access to overnight charging and a nascent network of public direct-current fast charging (DCFC). This article projects the DCFC infrastructure needed to electrify ride-hailing across 384 cities in the United States. Research leveraging a novel infrastructure projection tool, Electric Vehicle Infrastructure Tool for On-Demand Mobility Services model (EVI-OnDemand), estimates that 25,400 DCFC ports capable of charging vehicles at a mean power of 150 kW are required to electrify 1.45 million ride-hailing vehicles in the baseline scenario. Results show that ride-hailing vehicles require 17.5 DCFC ports per 1000 vehicles, three times that of personal electric vehicles (EVs). Infrastructure demand is also shown to vary across cities; 63% more DCFC ports are needed to support 1000 battery EVs in Chicago versus Miami. The analysis also includes sensitivity studies that explore variation in charging demand across input assumptions, finding that charging power, vehicle class, overnight charging access rates, and port utilization influence the network size needed. Projections vary from 18,600 to 41,300 DCFC ports across sensitivity scenarios, indicating that ride-hailing electrification will require significant expansion of access to fast charging even in the most optimistic scenarios, and investments into supporting assets can reduce the scale of the public charging expansion needed.

33 ADVANCED PROPULSION SYSTEMS↗

Etching of Si 3 N 4 induced by electron beam plasma from hollow cathode plasma in a downstream reactive environment

An etching system based on the interaction of electrons extracted from a direct current (DC) hollow-cathode (HC) Ar plasma and injected towards a Si3N4 covered silicon substrate located in the downstream reactive environment created by an additional remote CF 4 /O 2 plasma source was developed and evaluated. By controlling the properties of the injected beam electrons, this approach allows to deliver energy to a surface functionalized by exposure to reactive species, and initiate surface etching. The energy of the primary beam electrons is controlled by the acceleration voltage relative to the HC discharge. Ar atoms flow from the high-pressure HC discharge into the low pressure downstream reactive environment in the process chamber. For an acceleration voltage greater than the ionization potential of Ar and/or process gas species, the energetic primary beam electrons produce a secondary plasma in the process chamber, and can also cause additional dissociation. We have characterized the properties of the secondary plasma and also surface etching of Si 3 N 4 as a function of process parameters, including acceleration voltage (0-80 V), discharge current of the HC discharge (1-2 A), pressure (3.5-20 mTorr), source to substrate distance (1.5 to 5 cm), and feed gas composition (20% and 80% O2 in CF 4 /O 2 ). The electron energy probability function (EEPF) measured with a Langmuir probe about 2.5 cm below the extraction ring suggests several major groups of electrons for this situation, including high energy primary beam electrons with an energy that varies as the acceleration voltage is changed and low energy electrons produced by beam electron-induced ionization of the Ar gas in the process chamber. When a remote CF 4 /O 2 plasma is additionally coupled to the process chamber, Si 3 N 4 surfaces can be functionalized, and by varying the energy of the beam electrons, Si 3 N 4 etching can be induced by electron-neutral synergy effect with plasma-surface interaction. For conditions without beam electron injection, the remote plasma etching rate (ER) of Si 3 N 4 depends strongly on the O 2 concentration in the CF 4 /O 2 processing gas mixture and can be suppressed for O 2 -rich process conditions by the formation of a SiONF passivation layer on the Si 3 N 4 surface. The combination of the HC electron beam source with the remote plasma source (HCEB-RP) makes it possible to induce Si 3 N 4 etching for O 2 -rich remote plasma conditions where remote plasma by itself produces negligible Si 3 N 4 etching. The electron enhanced etching of Si 3 N 4 depends strongly on O 2 /CF 4 mixing ratio reflecting changing arrival rates of O and F species at the surface. Optical emission spectroscopy was used to estimate the ratio of gas phase F and O densities and found to be controlled by the gas mixing ratio and independent of HC EB operating conditions. At this time the detailed sequence of events operative in the etching mechanism is unclear. While the increase of the electron energy is ultimately responsible for initiating surface etching, at present we cannot rule out a role of ions from the simultaneously produced secondary plasma in plasma surface interaction mechanisms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radio-frequency magnetron sputter deposition of ultrathick boron carbide films

The deposition of thick B 4 C films with low residual stress by conventional direct-current magnetron sputtering is accompanied by the formation of dust particulates contaminating the target, chamber, and substrates and leading to the formation of nodular defects in films. Here, we demonstrate that the formation of particulates is greatly reduced during radio-frequency magnetron sputtering (RFMS). We systematically study properties of B 4 C films deposited by RFMS with a substrate temperature of 330 °C, a target-to-substrate distance of 10 cm, Ar working gas pressure in the range of 4.5–12.0 mTorr (0.6–1.6 Pa), and substrate tilt angles of 0°–80°. All films are x-ray amorphous. A columnar structure develops with increasing either Ar pressure or substrate tilt. For columnar films, the column tilt angle decreases with increasing Ar pressure, which we attribute to a corresponding increase in the width of the distribution of impact angles of deposition flux. In contrast to the Keller–Simmons rule, the deposition rate increases with increasing Ar pressure, which suggests a better coupling of the RF energy to the plasma processes that lead to target sputtering at higher pressures. There is a critical substrate tilt angle above which the total residual stress is close to zero. This critical substrate tilt angle is ~0° for an Ar pressure of 12 mTorr (1.6 Pa). The lower residual stress state, necessary for depositing ultrathick films, is characterized by a larger concentration of nanoscale inhomogeneities and decreased mechanical properties. Based on these results, RFMS deposition of 60-μm-thick B 4 C films is demonstrated.

36 MATERIALS SCIENCE↗

Optimization of an electron injector for operating high-intensity polarized electron beam

In this work, the simulation and optimization of an electron injector that operates a high-intensity polarized electron beam are presented. The electron injector would provide a single-bunch electron beam at a repetition rate of 1 Hz with a bunch charge of 10 nC, kinetic energy of 400 MeV and an electron spin polarization of 85%. A direct current (DC) high-voltage photogun was employed to produce the 10 nC polarized electron beam with a kinetic energy of 350 keV, beam diameter of 1.44 cm (Gaussian distribution with σ of 0.36 cm) and full bunch length of 1.3 ns (Gaussian distribution with σ of 0.325 ns). The beam was compressed to 6 ps of RMS bunch length using one 114.24 MHz standing-wave sub-harmonic buncher, two 571.2 MHz standing-wave sub-harmonic bunchers and one 2.856 GHz traveling-wave buncher. The beam was accelerated finally to 400 MeV via eight 2.856 GHz traveling-wave Linacs. We performed the beam simulation, and the simulated results showed that the optimized RMS bunch length was 4.65 ps, RMS relative energy spread was 0.48% and normalized RMS transverse emittance was 30.13 mm · mrad at a beam energy of 400 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗