Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

X-ray Diffraction Studies of Single-Crystal Materials for Broad Battery Applications

Single-crystal materials have attracted growing interest in battery research due to their well-defined crystallographic orientation, absence of grain boundaries, and enhanced mechanical and electrochemical stability. This Review provides a comprehensive overview of recent advances in the synthesis, structural evolution, and performance optimization of single-crystal electrodes and solid electrolytes. Particular focus is placed on the application of advanced X-ray diffraction (XRD) techniques, including operando synchrotron diffraction, reciprocal space mapping, and Bragg coherent diffraction imaging, which have enabled in-depth investigations of lattice strain, cation disorder, phase transitions, and defect formation. Representative case studies across Ni-rich layered oxides, spinel-type cathodes, and garnet-based electrolytes are examined to highlight the structural features unique to single crystals. Additionally, the synergistic integration of XRD with machine learning, tomography, and spectroscopy is discussed as a powerful direction for real-time analysis and predictive modeling. Furthermore, these insights provide critical guidance for the rational design of high-performance single-crystal materials in lithium, sodium, and solid-state battery systems.

25 ENERGY STORAGE↗

Ultra Low Level Environmental Neutron Measurements Using Superheated Droplet Detectors

Through the application of superheated droplet detectors (SDDs), the SIMPLE project for the direct search for dark matter (DM) reached the most restrictive limits on the spin-dependent sector to date. The experiment is based on the detection of recoils following WIMP-nuclei interaction, mimicking those from neutron scattering. The thermodynamic operation conditions yield the SDDs intrinsically insensitive to radiations with linear energy transfer below ∼150 keVμm{sup -1} such as photons, electrons, muons and neutrons with energies below ∼40 keV. Underground facilities are increasingly employed for measurements in a low-level radiation background (DM search, gamma-spectroscopy, intrinsic soft-error rate measurements, etc.), where the rock overburden shields against cosmic radiation. In this environment the SDDs are sensitive only to α-particles and neutrons naturally emitted from the surrounding materials. Recently developed signal analysis techniques allow discrimination between neutron and α-induced signals. SDDs are therefore a promising instrument for low-level neutron and α measurements, namely environmental neutron measurements and α-contamination assays. In this work neutron measurements performed in the challenging conditions of the latest SIMPLE experiment (1500 mwe depth with 50-75 cm water shield) are reported. The results are compared with those obtained by detailed Monte Carlo simulations of the neutron background induced by {sup 238}U and {sup 232}Th traces in the facility, shielding and detector materials. Calculations of the neutron energy distribution yield the following neutron fluence rates (in 10{sup -8} cm{sup -2}s{sup -1}): thermal (<0.5 eV): 2.5; epithermal (0.5 eV-100 keV): 2.2; fast (>1 MeV): 3.9. Signal rates were derived using standard cross sections and codes routinely employed in reactor dosimetry. The measured and calculated neutron count rates per unit of active mass were 0.15 ct/kgd and 0.33 ct/kg-d respectively. As the major signal contribution (98%) originates from radio-impurities in the detector container, alternative materials will be employed in future devices. Latest results regarding the improvement of the detector characterization accuracy towards its application in environmental neutron detection are in progress and will be described. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging a solvent-swollen polymer gel network by open liquid transmission electron microscopy

Visualizing the network of a solvent-swollen polymer gel remains problematic. To address this challenge, open transmission electron microscopy (TEM) was applied to thin gel films permeated by a nonvolatile ionic liquid. The targeted physical gels were prepared by cooling concentrated solutions of poly(ethylene glycol) in 1-ethyl-3-methyl imidazolium ethyl sulfate [EMIM][EtSO 4 ]. During the cooling, gelation occurred by a frustrated crystallization of the dissolved polymer, leading to a percolated, solvent-permeated semicrystalline network in which nanoscale polymer crystals acted as crosslinks. Crystalline features ranging from ~5 to ~200 nm were observed, with the visible network strands dominantly consisting of long curvilinear crystallites of ~15–20 nm diameter. Nascent spherulites irregularly decorated the network, creating a complex structural hierarchy that complicated analyses. Lacking diffraction contrast, TEM did not visualize the many disordered, fully solvated PEG chains present in the voids between crystals. Finally, recognizing that a network's three dimensionality is ambiguous when assessed through two-dimensional microscopy projections, a small gel region was studied by TEM tomography, revealing a nearly isotropic three-dimensional arrangement of the curvilinear crystallites, which displayed remarkably uniform cylindrical cross sections.

36 MATERIALS SCIENCE↗

Detecting Cage Crossing and Filling Clusters of Magnesium and Carbon Atoms in Zeolite SSZ-13 with Atom Probe Tomography

The conversion of methanol to valuable hydrocarbon molecules is of great commercial interest, as the process serves as a sustainable alternative for the production of, for instance, the base chemicals for plastics. The reaction is catalyzed by zeolite materials. By the introduction of magnesium as a cationic metal, the properties of the zeolite, and thereby the catalytic performance, are changed. With atom probe tomography (APT), nanoscale relations within zeolite materials can be revealed: i.e., crucial information for a fundamental mechanistic understanding. We show that magnesium forms clusters within the cages of zeolite SSZ-13, while the framework elements are homogeneously distributed. These clusters of just a few nanometers were analyzed and visualized in 3-D. Magnesium atoms seem to initially be directed to the aluminum sites, after which they aggregate and fill one or two cages in the zeolite SSZ-13 structure. The presence of magnesium in zeolite SSZ-13 increases the lifetime as well as the propylene selectivity. By using operando UV–vis spectroscopy and X-ray diffraction techniques, we are able to show that these findings are related to the suppression of aromatic intermediate products, while maintaining the formation of polyaromatic compounds. Further nanoscale analysis of the spent catalysts showed indications of magnesium redistribution after catalysis. Unlike zeolite H-SSZ-13, for which only a homogeneous distribution of carbon was found, carbon can be either homogeneously or heterogeneously distributed within zeolite Mg-SSZ-13 crystals as the magnesium decreases the coking rate. Carbon clusters were isolated, visualized, and analyzed and were assumed to be polyaromatic compounds. Small one-cage-filling polyaromatic compounds were identified; furthermore, large-cage-crossing aromatic molecules were found by isolating large coke clusters, demonstrating the unique coking mechanism in zeolite SSZ-13. Short-length-scale evidence for the formation of polyaromatic compounds at acid sites is discovered, as clear nanoscale relations between aluminum and carbon atoms exist.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchrotron radiation - Applications in the earth sciences

Synchrotron-radiation sources and their characteristics are overviewed along with recent synchrotron-based research on earth materials and future earth-science applications utilizing the next generation of synchrotron-radiation sources presently under construction. Focus is placed on X-ray scattering studies of earth materials (crystalline and noncrystalline) under ambient conditions, diffraction studies of earth materials at high pressures and/or temperatures, spectroscopic studies, primarily X-ray absorption spectroscopy, and spatially resolved X-ray fluorescence studies of compositional variations in earth materials. It is noted that other synchrotron-based methods, such as X-ray tomography and topography may become important in characterizing earth materials, while soft X-ray/vacuum ultraviolet radiation from synchrotron sources can be applied to problems involving the structural environments of low-atomic-number elements and the characterization of surface reactions of minerals with liquids and gases.

Bassett, W. A.↗

Sol–gel synthesis, structure and luminescence properties of Ba{sub 2}ZnMoO{sub 6}:Eu{sup 3+} phosphors

Graphical abstract: The phosphor powders of Ba{sub 2}ZnMoO{sub 6}:Eu{sup 3+} were prepared by sol–gel method. The dependence of luminescence intensity on the Eu{sup 3+} concentration was investigated. - Highlights: • We synthesize Ba{sub 2}ZnMoO{sub 6}:Eu{sup 3+} phosphors by the sol–gel method. • The effect of temperature on the crystallinity and morphology is investigated. • The phosphor presents an intense CT band in near UV range (370–410 nm). • The concentration quenching mechanism is the exchange interaction. - Abstract: Double-perovskite Ba{sub 2}Zn{sub 1−x}MoO{sub 6}:xEu{sup 3+} (x = 0, 0.02, 0.04, 0.06, 0.08, 0.1) orange–red emitting phosphors were synthesized by using the sol–gel method. The crystalline structure and photoluminescence properties of the phosphors were investigated. The X-ray diffraction (XRD) patterns indicate that the structure of matrix Ba{sub 2}ZnMoO{sub 6} is cubic double-perovskite with space group Fm-3m. The Ba{sub 2}ZnMoO{sub 6}:Eu{sup 3+} phosphors present an intense broad charge transfer (CT) band absorption in near UV range (370–410 nm), which attributes to the charge transfer state of MoO{sub 6}, and performs orange–red emission of Eu{sup 3+} ({sup 5}D{sub 0} → {sup 7}F{sub 1} transition) at around 596 nm. A low concentration quenching occurs in Ba{sub 2}ZnMoO{sub 6}:Eu{sup 3+} and the optimal doping concentration is about 6 mol%. The Ba{sub 2}ZnMoO{sub 6}:Eu{sup 3+} phosphors are considered to be a promising orange–red emitting phosphor for near ultraviolet GaN-based white light emitting diode.

36 MATERIALS SCIENCE↗

Analysis of Selected Legacy 85 Kr Samples

Legacy samples composed of 85 Kr encapsulated in solid zeolite 5A material and five small metal tubes containing a mixture of the zeolite combined with a glass matrix resulting from hot isostatic pressing have been preserved. The samples were a result of krypton R&D encapsulation efforts in the late 1970s performed at the Idaho Chemical Processing Plant. These samples were shipped to Oak Ridge National Laboratory (ORNL) in mid-FY 2014. Upon receipt the outer shipping package was opened, and the inner package, removed and placed in a radiological hood. The individual capsules were double bagged as they were removed from the inner shipping pig and placed into individual glass sample bottles for further analysis. The five capsules were then x-ray imaged. Capsules 1 and 4 appear intact and to contain an amorphous mass within the capsules. Capsule 2 clearly shows the saw marks on the capsule and a quantity of loose pellet or bead-like material remaining in the capsule. Capsule 3 shows similar bead-like material within the intact capsule. Capsule 5 had been opened at an undetermined time in the past. The end of this capsule appears to have been cut off, and there are additional saw marks on the side of the capsule. X-ray tomography allowed the capsules to be viewed along the three axes. Of most interest was determining whether there was any residual material in the closed end of Capsule 5. The images confirmed the presence of residual material within this capsule. The material appears to be compacted but still retains some of the bead-like morphology. Based on the nondestructive analysis (NDA) results, a proposed path forward was formulated to advance this effort toward the original goals of understanding the effects of extended storage on the waste form and package. Based on the initial NDA and the fact that there are at least two breached samples, it was proposed that exploratory tests be conducted with the breached specimens before opening the three intact capsules. Portions of these would be analyzed to determine the fraction of krypton/xenon remaining in the matrix and the amount of rubidium remaining in the matrix. The inner surface of the breached capsules would be examined for corrosion. The materials contained in Capsules 2 and 5 have been examined. There appears to be a relatively uniform distribution of Kr and Rb throughout the pellets examined. The chemical composition of the pellets appears to be consistent with 5A molecular sieves. The material contained within Capsule 5 showed ~1 at. % lead. The origin of the Pb is currently indeterminate. X-ray diffraction analysis shows a significant shift from the 5A structure, most likely due to the Kr encapsulation / sintering process that occurred when the samples were made. The capsule walls were also examined and showed extensive corrosion throughout. Elemental mapping of the capsule material appeared consistent with carbon steel, while the weld material appeared consistent with a stainless steel. The interior surface of the capsule appeared to have a layer of material containing Al, Si, and Ca similar to the 5A molecular sieve. Analysis for Rb within the corrosion sites was inconclusive.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information

Purpose: X-ray scatter incurred to detectors degrades the quality of cone-beam computed tomography (CBCT) and represents a problem in volumetric image guided and adaptive radiation therapy. Several methods using a beam blocker for the estimation and subtraction of scatter have been proposed. However, due to missing information resulting from the obstruction of the blocker, such methods require dual scanning or dynamically moving blocker to obtain a complete volumetric image. Here, we propose a half beam blocker-based approach, in conjunction with a total variation (TV) regularized Feldkamp-Davis-Kress (FDK) algorithm, to correct scatter-induced artifacts by simultaneously acquiring image and scatter information from a single-rotation CBCT scan. Methods: A half beam blocker, comprising lead strips, is used to simultaneously acquire image data on one side of the projection data and scatter data on the other half side. One-dimensional cubic B-Spline interpolation/extrapolation is applied to derive patient specific scatter information by using the scatter distributions on strips. The estimated scatter is subtracted from the projection image acquired at the opposite view. With scatter-corrected projections where this subtraction is completed, the FDK algorithm based on a cosine weighting function is performed to reconstruct CBCT volume. To suppress the noise in the reconstructed CBCT images produced by geometric errors between two opposed projections and interpolated scatter information, total variation regularization is applied by a minimization using a steepest gradient descent optimization method. The experimental studies using Catphan504 and anthropomorphic phantoms were carried out to evaluate the performance of the proposed scheme. Results: The scatter-induced shading artifacts were markedly suppressed in CBCT using the proposed scheme. Compared with CBCT without a blocker, the nonuniformity value was reduced from 39.3% to 3.1%. The root mean square error relative to values inside the regions of interest selected from a benchmark scatter free image was reduced from 50 to 11.3. The TV regularization also led to a better contrast-to-noise ratio. Conclusions: An asymmetric half beam blocker-based FDK acquisition and reconstruction technique has been established. The proposed scheme enables simultaneous detection of patient specific scatter and complete volumetric CBCT reconstruction without additional requirements such as prior images, dual scans, or moving strips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Interactive 3D Visualization Tool for Customizable Analyses of Tomography Datasets in Material Science

Current methods for visualizing and analyzing 3D tomography datasets in materials science often lack the interactivity and depth required for detailed structural insights. This limitation restricts a researchers' ability to accurately interpret complex data, which is critical for advancing material innovations and understanding structural properties. To address this issue, we have developed a novel, web-based interactive 3D visualization and analysis tool from the Trame framework that offers customizable features to enhance data interpretability. The tool allows users to adjust parameters such as visible range, slice planes, data rotation, and layering, providing a more detailed and dynamic view of complex structures. Its user-friendly web interface increases the accessibility and ease of use for both novice and experienced researchers, to visualize large volumetric datasets. The tool supports a diverse range of data formats, making it versatile for various research applications. Unique capabilities include real-time data manipulation, automated feature detection, context-sensitive feedback, and real-time volume calculations and distributions per sliced region or layer, alongside the ability to quickly generate high-quality screenshots and videos for presentations and reports. These advancements offer a comprehensive solution for enhanced 3D data exploration, significantly improving the analysis process and communication of results in materials science.

36 - MATERIALS SCIENCE↗

Radiation Induced Segregation at Grain Boundaries in Steels: NSUF 2018 Milestone Report

This document outlines the user supported post-irradiation characterization by Oak Ridge National Laboratory under the Nuclear Scientific User Facility Consolidated Innovative Nuclear Research project, “Correlative Atom Probe and Electron Microscopy Study of Radiation Induced Segregation at Low and High Angle Grain Boundaries in Steels.” Fiscal Year 2018 was the second of a two-year project aimed at using analytical electron microscopy combined with atom probe tomography (APT) to probe the nanometer length scale segregations in austenitic stainless steels after neutron irradiation. Particularly, analytical electron microscopy using the FEI F200X Talos was successfully completed in the first year, and the second year was focused on APT study. Scanning electron microscopy (SEM) coupled with an electron backscatter diffraction (EBSD) detector was performed on selected specimens to locate high and low angle grain boundaries for targeted specimen preparation using focused ion beam (FIB). FIB prepared lift outs were used for APT examination of the grain boundaries using a Cameca Instruments LEAP 4000X HR instrument. This report briefly summarizes the specimen preparation and APT results obtained at the Center for Advanced Energy Studies.

36 MATERIALS SCIENCE↗

A New Residual Strain Mapping Program Using Energy Dispersive X-Ray Diffraction at the Advanced Photon Source

Here, the ability to non-destructively map the residual strain field inside an engineering component is important for predicting its fatigue life or developing processing methods to prevent failure or enhance performance. In this paper, we describe a new residual strain mapping program at the Advanced Photon Source, Argonne National Laboratory. The new program is based on energy dispersive x-ray diffraction (EDXRD). It is capable of non-destructively penetrating a several- cm thick polycrystalline sample fabricated from engineering alloys using high-energy x-rays and measuring the residual strain field with mm or better spatial resolution and approximately ±1 x 10 -4 strain resolution. A multi-element detector array is employed to measure multiple strain components simultaneously. The residual strain mapping setup is augmented with a high-energy tomography capability, allowing precise alignment of the material volume of interest for residual strain mapping and providing a complementary view of the structure to understand the measured strain field. These measurement capabilities are demonstrated using several strain mapping examples ranging from polycrystalline structural alloys to biological materials. We also provide some guidance for the future users of the program for a successful residual strain mapping experiment. We are expanding the capabilities of the new setup with various in situ capabilities including thermo-mechanical loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reaching the third dimension

X-ray imaging is extensively used in medical and materials science. Traditionally, the depth dimension is obtained by turning the sample to gain different views. The famous penetrating properties of X-rays mean that projection views of the subject sample can be readily obtained in the linear absorption regime. 180 degrees of projections can then be combined using computed tomography (CT) methods to obtain a full 3D image, a technique extensively used in medical imaging. In the work now presented in Nature Materials, Stephan Hruszkewycz and colleagues have demonstrated genuine 3D imaging by a new method called 3D Bragg projection ptychography1. Our approach combines the 'side view' capability of using Bragg diffraction from a crystalline sample with the coherence capabilities of ptychography. Thus, it results in a 3D image from a 2D raster scan of a coherent beam across a sample that does not have to be rotated.

36 MATERIALS SCIENCE↗

The PICASSO digital detector for Diffraction Enhanced Imaging at ELETTRA

A clinical mammography program is in progress at the medical beamline SYRMEP of the Italian synchrotron radiation laboratory ELETTRA in Trieste. A conventional screen-film system is utilized as detector for the examinations on patients. For the next experimental step a digital detector has been designed taking into account the essential requirements for mammography such as high spatial and contrast resolution, high efficiency for low dose examinations and high speed for short acquisition time. A double-layer prototype has already been tested in the frame of the PICASSO project. In addition, an analyzer crystal set-up for Diffraction Enhanced Imaging (DEI) has been available for many years at the SYRMEP beamline. Applying the DEI technique several successful experiments have been carried out in biomedical imaging and in particular in-vitro breast imaging utilizing commercially available detectors. Recently a system upgrade yielded a double-crystal analyzer set-up with improved stability and higher angular resolution. In this study the PICASSO detector has been utilized in combination with the new analyzer set-up for imaging in-vitro breast tissue samples. In order to test the potential of the combined system planar and tomographic images have been acquired and the first results are here presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray scatter correction method for dedicated breast computed tomography

Purpose: To improve image quality and accuracy in dedicated breast computed tomography (BCT) by removing the x-ray scatter signal included in the BCT projections. Methods: The previously characterized magnitude and distribution of x-ray scatter in BCT results in both cupping artifacts and reduction of contrast and accuracy in the reconstructions. In this study, an image processing method is proposed that estimates and subtracts the low-frequency x-ray scatter signal included in each BCT projection postacquisition and prereconstruction. The estimation of this signal is performed using simple additional hardware, one additional BCT projection acquisition with negligible radiation dose, and simple image processing software algorithms. The high frequency quantum noise due to the scatter signal is reduced using a noise filter postreconstruction. The dosimetric consequences and validity of the assumptions of this algorithm were determined using Monte Carlo simulations. The feasibility of this method was determined by imaging a breast phantom on a BCT clinical prototype and comparing the corrected reconstructions to the unprocessed reconstructions and to reconstructions obtained from fan-beam acquisitions as a reference standard. One-dimensional profiles of the reconstructions and objective image quality metrics were used to determine the impact of the algorithm. Results: The proposed additional acquisition results in negligible additional radiation dose to the imaged breast ({approx}0.4% of the standard BCT acquisition). The processed phantom reconstruction showed substantially reduced cupping artifacts, increased contrast between adipose and glandular tissue equivalents, higher voxel value accuracy, and no discernible blurring of high frequency features. Conclusions: The proposed scatter correction method for dedicated breast CT is feasible and can result in highly improved image quality. Further optimization and testing, especially with patient images, is necessary to characterize its impact on clinical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging

Purpose: This work applies a cascaded systems model for cone-beam CT imaging performance to the design and optimization of a system for musculoskeletal extremity imaging. The model provides a quantitative guide to the selection of system geometry, source and detector components, acquisition techniques, and reconstruction parameters. Methods: The model is based on cascaded systems analysis of the 3D noise-power spectrum (NPS) and noise-equivalent quanta (NEQ) combined with factors of system geometry (magnification, focal spot size, and scatter-to-primary ratio) and anatomical background clutter. The model was extended to task-based analysis of detectability index (d') for tasks ranging in contrast and frequency content, and d' was computed as a function of system magnification, detector pixel size, focal spot size, kVp, dose, electronic noise, voxel size, and reconstruction filter to examine trade-offs and optima among such factors in multivariate analysis. The model was tested quantitatively versus the measured NPS and qualitatively in cadaver images as a function of kVp, dose, pixel size, and reconstruction filter under conditions corresponding to the proposed scanner. Results: The analysis quantified trade-offs among factors of spatial resolution, noise, and dose. System magnification (M) was a critical design parameter with strong effect on spatial resolution, dose, and x-ray scatter, and a fairly robust optimum was identified at M {approx} 1.3 for the imaging tasks considered. The results suggested kVp selection in the range of {approx}65-90 kVp, the lower end (65 kVp) maximizing subject contrast and the upper end maximizing NEQ (90 kVp). The analysis quantified fairly intuitive results--e.g., {approx}0.1-0.2 mm pixel size (and a sharp reconstruction filter) optimal for high-frequency tasks (bone detail) compared to {approx}0.4 mm pixel size (and a smooth reconstruction filter) for low-frequency (soft-tissue) tasks. This result suggests a specific protocol for 1 x 1 (full-resolution) projection data acquisition followed by full-resolution reconstruction with a sharp filter for high-frequency tasks along with 2 x 2 binning reconstruction with a smooth filter for low-frequency tasks. The analysis guided selection of specific source and detector components implemented on the proposed scanner. The analysis also quantified the potential benefits and points of diminishing return in focal spot size, reduced electronic noise, finer detector pixels, and low-dose limits of detectability. Theoretical results agreed quantitatively with the measured NPS and qualitatively with evaluation of cadaver images by a musculoskeletal radiologist. Conclusions: A fairly comprehensive model for 3D imaging performance in cone-beam CT combines factors of quantum noise, system geometry, anatomical background, and imaging task. The analysis provided a valuable, quantitative guide to design, optimization, and technique selection for a musculoskeletal extremities imaging system under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TRTR NRAD NRS Beamline Abstract

The Neutron Radiography (NRAD) Reactor is a 250kW TRIGA housed under the largest hot cell in the United States, making it the foremost location to perform neutron imaging of irradiated nuclear fuels and materials, including those intended for use with advanced reactors. Currently, NRAD has two radial beamlines that are used for neutron radiography and tomography. Upgrades to the North neutron beamline include the replacement of the in-tank beam chamber, through-the-wall collimator, and neutron shutter. These beamline upgrades will not only improve image quality for current capabilities but will also condition the beam to be more suitable for advanced methods such as neutron powder diffraction. These upgrades will increase the excess reactivity of the core, reduce unnecessary activation and exposure to workers, and significantly reduce the amount of shielding required around the beam. This presentation will describe how these upgrades improve beam quality, increase utilization of the reactor, and reduce radiation exposure to personnel.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Future of Electron Scattering and Diffraction

The ability to correlate the atomic- and nanoscale-structure of condensed matter with physical properties (e.g., mechanical, electrical, catalytic, and optical) and functionality forms the core of many disciplines. Directing and controlling materials at the quantum-, atomic-, and molecular-levels creates enormous challenges and opportunities across a wide spectrum of critical technologies, including those involving the generation and use of energy. The workshop identified next generation electron scattering and diffraction instruments that are uniquely positioned to address these grand challenges. The workshop participants identified four key areas where the next generation of such instrumentation would have major impact: A – Multidimensional Visualization of Real Materials B – Atomic-scale Molecular Processes C – Photonic Control of Emergence in Quantum Materials D – Evolving Interfaces, Nucleation, and Mass Transport Real materials are comprised of complex three-dimensional arrangements of atoms and defects that directly determine their potential for energy applications. Understanding real materials requires new capabilities for three-dimensional atomic scale tomography and spectroscopy of atomic and electronic structures with unprecedented sensitivity, and with simultaneous spatial and energy resolution. Many molecules are able to selectively and efficiently convert sunlight into other forms of energy, like heat and electric current, or store it in altered chemical bonds. Understanding and controlling such process at the atomic scale require unprecedented time resolution. One of the grand challenges in condensed matter physics is to understand, and ultimately control, emergent phenomena in novel quantum materials that necessitate developing a new generation of instruments that probe the interplay among spin, charge, orbital, and lattice degrees of freedom with intrinsic time- and length-scale resolutions. Molecules and soft matter require imaging and spectroscopy with high spatial resolution without damaging their structure. The strong interaction of electrons with matter allows high-energy electron pulses to gather structural information before a sample is damaged. Electron ScatteringImaging, diffraction, and spectroscopy are the fundamental capabilities of electron-scattering instruments. The DOE BES-funded TEAM (Transmission Electron Aberration-corrected Microscope) project achieved unprecedented sub-atomic spatial resolution in imaging through aberration-corrected transmission electron microscopy. To further advance electron scattering techniques that directly enable groundbreaking science, instrumentation must advance beyond traditional two-dimensional imaging. Advances in temporal resolution, recording the full phase and energy spaces, and improved spatial resolution constitute a new frontier in electron microscopy, and will directly address the BES Grand Challenges, such as to “control the emergent properties that arise from the complex correlations of atomic and electronic constituents” and the “hidden states” “very far away from equilibrium”. Ultrafast methods, such as the pump-probe approach, enable pathways toward understanding, and ultimately controlling, the chemical dynamics of molecular systems and the evolution of complexity in mesoscale and nanoscale systems. Central to understanding how to synthesize and exploit functional materials is having the ability to apply external stimuli (such as heat, light, a reactive flux, and an electrical bias) and to observe the resulting dynamic process in situ and in operando, and under the appropriate environment (e.g., not limited to UHV conditions). To enable revolutionary advances in electron scattering and science, the participants of the workshop recommended three major new instrumental developments: A. Atomic-Resolution Multi-Dimensional Transmission Electron Microscope: This instrument would provide quantitative information over the entire real space, momentum space, and energy space for visualizing dopants, interstitials, and light elements; for imaging localized vibrational modes and the motion of charged particles and vacancies; for correlating lattice, spin, orbital, and charge; and for determining the structure and molecular chemistry of organic and soft matter. The instrument will be uniquely suited to answer fundamental questions in condensed matter physics that require understanding the physical and electronic structure at the atomic scale. Key developments include stable cryogenic capabilities that will allow access to emergent electronic phases, as well as hard/soft interfaces and radiation- sensitive materials. B. Ultrafast Electron Diffraction and Microscopy Instrument: This instrument would be capable of nano-diffraction with 10 fs temporal resolution in stroboscopic mode, and better than 100 fs temporal resolution in single shot mode. The instrument would also achieve single- shot real-space imaging with a spatial/temporal resolution of 10 nm/10 ps, representing a thousand fold improvement over current microscopes. Such a capability would be complementary to x-ray free electron lasers due to the difference in the nature of electron and x-ray scattering, enabling space-time mapping of lattice vibrations and energy transport, facilitating the understanding of molecular dynamics of chemical reactions, the photonic control of emergence in quantum materials, and the dynamics of mesoscopic materials. C. Lab-In-Gap Dynamic Microscope: This instrument would enable quantitative measurements of materials structure, composition, and bonding evolution in technologically relevant environments, including liquids, gases and plasmas, thereby assuring the understanding of structure function relationship at the atomic scale with up to nanosecond temporal resolution. This instrument would employ a versatile, modular sample stage and holder geometry to allow the multi-modal (e.g., optical, thermal, mechanical, electrical, and electrochemical) probing of materials’ functionality in situ and in operando. The electron optics encompasses a pole piece that can accommodate the new stage, differential pumping, detectors, aberration correctors, and other electron optical elements for measurement of materials dynamics. To realize the proposed instruments in a timely fashion, BES should aggressively support research and development of complementary and enabling instruments, including new electron sources, advanced electron optics, new tunable specimen pumps and sample stages, and new detectors. The proposed instruments would have transformative impact on physics, chemistry, materials science, engineering

43 PARTICLE ACCELERATORS↗

Tomography of ultrarelativistic nuclei with polarized photon-gluon collisions

A linearly polarized photon can be quantized from the Lorentz-boosted electromagnetic field of a nucleus traveling at ultrarelativistic speed. When two relativistic heavy nuclei pass one another at a distance of a few nuclear radii, the photon from one nucleus may interact through a virtual quark-antiquark pair with gluons from the other nucleus, forming a short-lived vector meson (e.g., ρ 0 ). In this experiment, the polarization was used in diffractive photoproduction to observe a unique spin interference pattern in the angular distribution of ρ 0 → π + π – decays. The observed interference is a result of an overlap of two wave functions at a distance an order of magnitude larger than the ρ0 travel distance within its lifetime. The strong-interaction nuclear radii were extracted from these diffractive interactions and found to be 6.53 ± 0.06 fm ( 197 Au) and 7.29 ± 0.08 fm ( 238 U), larger than the nuclear charge radii. The observable is demonstrated to be sensitive to the nuclear geometry and quantum interference of nonidentical particles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗