Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diameter distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Primary Modes of Global Drop Size Distributions

Understanding drop size distribution (DSD) variability has important implications for remote sensing and numerical modeling applications. Twelve disdrometer datasets across three latitude bands are analyzed in this study, spanning a broad range of precipitation regimes: light rain, orographic, deep convective, organized midlatitude, and tropical oceanic. Principal component analysis (PCA) is used to reveal comprehensive modes of global DSD spatial and temporal variability. Although the locations contain different distributions of individual DSD parameters, all locations are found to have the same modes of variability. Based on PCA, six groups of points with unique DSD characteristics emerge. The physical processes that underpin these groups are revealed through supporting radar observations. Group 1 (group 2) is characterized by high (low) liquid water content (LWC), broad (narrow) distribution widths, and large (small) median drop diameters D 0 . Radar analysis identifies group 1 (group 2) as convective (stratiform) rainfall. Group 3 is characterized by weak, shallow radar echoes and large concentrations of small drops, indicative of warm rain showers. Group 4 identifies heavy stratiform precipitation. The low latitudes exhibit distinct bimodal distributions of the normalized intercept parameter N w , LWC, and D 0 and are found to have a clustering of points (group 5) with high rain rates, large N w , and moderate D 0 , a signature of robust warm rain processes. A distinct group associated with ice-based convection (group 6) emerges in the midlatitudes. Although all locations exhibit the same covariance of parameters associated with these groups, it is likely that the physical processes responsible for shaping the DSDs vary as a function of location.

54 ENVIRONMENTAL SCIENCES↗

Size, Composition, and Source Profiles of Inhalable Bioaerosols from Colorado Dairies

Particulate matter emissions from agricultural livestock operations contain both chemical and biological constituents that represent a potential human health hazard. The size and composition of these dusts, however, have not been well described. We evaluated the full size distribution (from 0 to 100 μm in aerodynamic diameter) and chemical/biological composition of inhalable dusts inside several Colorado dairy parlors. Four aerodynamic size fractions (<3, 3-10, 10-30, and >30 μm) were collected and analyzed using a combination of physiochemical techniques to understand the structure of bacterial communities and chemical constituents. Airborne particulate mass followed a bimodal size distribution (one mode at 3 μm and a second above 30 μm), which also correlated with the relative concentrations of the following microbiological markers: bacterial endotoxin, 3-hydroxy fatty acids, and muramic acid. Sequencing of the 16S- rRNA components of this aerosol revealed a microbiome derived predominantly from animal sources. Bacterial genera included Staphlyococcus, Pseudomonas, and Streptococcus, all of which have proinflammatory and pathogenic capacity. Our results suggest that the size distribution of bioaerosols emitted by dairy operations extends well above 10 μm in diameter and contains a diverse mixture of potentially hazardous constituents and opportunistic pathogens. These findings should inform the development of more effective emissions control strategies.

Schaeffer, Joshua W↗

Dosimetric characterization of round HDR {sup 192}Ir AccuBoost applicators for breast brachytherapy

Purpose: The AccuBoost brachytherapy system applies HDR {sup 192}Ir beams peripherally to the breast using collimating applicators. The purpose of this study was to benchmark Monte Carlo simulations of the HDR {sup 192}Ir source, to dosimetrically characterize the round applicators using established Monte Carlo simulation and radiation measurement techniques and to gather data for clinical use. Methods: Dosimetric measurements were performed in a polystyrene phantom, while simulations estimated dose in air, liquid water, polystyrene and ICRU 44 breast tissue. Dose distribution characterization of the 4-8 cm diameter collimators was performed using radiochromic EBT film and air ionization chambers. Results: The central axis dose falloff was steeper for the 4 cm diameter applicator in comparison to the 8 cm diameter applicator, with surface to 3 cm depth-dose ratios of 3.65 and 2.44, respectively. These ratios did not considerably change when varying the phantom composition from breast tissue to polystyrene, phantom thickness from 4 to 8 cm, or phantom radius from 8 to 15 cm. Dose distributions on the central axis were fitted to sixth-order polynomials for clinical use in a hand calculation spreadsheet (i.e., nomogram). Dose uniformity within the useful applicator apertures decreased as depth-dose increased. Conclusions: Monte Carlo benchmarking simulations of the HDR {sup 192}Ir source using the MCNP5 radiation transport code indicated agreement within 1% of the published results over the radial/angular region of interest. Changes in phantom size and radius did not cause noteworthy changes in the central axis depth-dose. Polynomial fit depth-dose curves provide a simple and accurate basis for a nomogram.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Definition of the Spatial Resolution of X-Ray Microanalysis in Thin Foils

The spatial resolution of X-ray microanalysis in thin foils is defined in terms of the incident electron beam diameter and the average beam broadening. The beam diameter is defined as the full width tenth maximum of a Gaussian intensity distribution. The spatial resolution is calculated by a convolution of the beam diameter and the average beam broadening. This definition of the spatial resolution can be related simply to experimental measurements of composition profiles across interphase interfaces. Monte Carlo calculations using a high-speed parallel supercomputer show good agreement with this definition of the spatial resolution and calculations based on this definition. The agreement is good over a range of specimen thicknesses and atomic number, but is poor when excessive beam tailing distorts the assumed Gaussian electron intensity distributions. Beam tailing occurs in low-Z materials because of fast secondary electrons and in high-Z materials because of plural scattering.

Williams, D. B.↗

An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions

Certain brachytherapy dose distributions, such as those for LDR prostate implants, are readily modeled by treatment planning systems (TPS) that use the superposition principle of individual seed dose distributions to calculate the total dose distribution. However, dose distributions for brachytherapy treatments using high-Z shields or having significant material heterogeneities are not currently well modeled using conventional TPS. The purpose of this study is to establish a new treatment planning technique (Tufts technique) that could be applied in some clinical situations where the conventional approach is not acceptable and dose distributions present cylindrical symmetry. Dose distributions from complex brachytherapy source configurations determined with Monte Carlo methods were used as input data. These source distributions included the 2 and 3 cm diameter Valencia skin applicators from Nucletron, 4-8 cm diameter AccuBoost peripheral breast brachytherapy applicators from Advanced Radiation Therapy, and a 16 mm COMS-based eye plaque using {sup 103}Pd, {sup 125}I, and {sup 131}Cs seeds. Radial dose functions and 2D anisotropy functions were obtained by positioning the coordinate system origin along the dose distribution cylindrical axis of symmetry. Origin:tissue distance and active length were chosen to minimize TPS interpolation errors. Dosimetry parameters were entered into the PINNACLE TPS, and dose distributions were subsequently calculated and compared to the original Monte Carlo-derived dose distributions. The new planning technique was able to reproduce brachytherapy dose distributions for all three applicator types, producing dosimetric agreement typically within 2% when compared with Monte Carlo-derived dose distributions. Agreement between Monte Carlo-derived and planned dose distributions improved as the spatial resolution of the fitted dosimetry parameters improved. For agreement within 5% throughout the clinical volume, spatial resolution of dosimetry parameter data {<=}0.1 cm was required, and the virtual brachytherapy source data set included over 5000 data points. On the other hand, the lack of consideration for applicator heterogeneity effect caused conventional dose overestimates exceeding an order of magnitude in regions of clinical interest. This approach is rationalized by the improved dose estimates. In conclusion, a new technique was developed to incorporate complex Monte Carlo-based brachytherapy dose distributions into conventional TPS. These results are generalizable to other brachytherapy source types and other TPS.

61 RADIATION PROTECTION AND DOSIMETRY↗

A CHARA ARRAY SURVEY OF CIRCUMSTELLAR DISKS AROUND NEARBY Be-TYPE STARS

We report on a high angular resolution survey of circumstellar disks around 24 northern sky Be stars. The K-band continuum survey was made using the CHARA Array long baseline interferometer (baselines of 30-331 m). The interferometric visibilities were corrected for the flux contribution of stellar companions in those cases where the Be star is a member of a known binary or multiple system. For those targets with good (u, v) coverage, we used a four-parameter Gaussian elliptical disk model to fit the visibilities and to determine the axial ratio, position angle, K-band photospheric flux contribution, and angular diameter of the disk's major axis. For the other targets with relatively limited (u, v) coverage, we constrained the axial ratio, inclination angle, and/or disk position angle where necessary in order to resolve the degeneracy between possible model solutions. We also made fits of the ultraviolet and infrared spectral energy distributions (SEDs) to estimate the stellar angular diameter and infrared flux excess of each target. The mean ratio of the disk diameter (measured in K-band emission) to stellar diameter (from SED modeling) is 4.4 among the 14 cases where we reliably resolved the disk emission, a value which is generally lower than the disk size ratio measured in the higher opacity H{alpha} emission line. We estimated the equatorial rotational velocity from the projected rotational velocity and disk inclination for 12 stars, and most of these stars rotate close to or at the critical rotational velocity.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses

This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of ~40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ~35 to ~300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 10 12 photons per µm 2 per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. Finally, the results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The detection of molecular gas in the ring galaxy Arp 143

We have used the NRAO 12 m telescope to map the inner 10 kpc of NGC 2445, the ring galaxy in Arp 143, in CO-12(J = 1-0). Emission is peaked near the ring galaxy nucleus, but we find evidence for an additional asymmetric and extended CO component. This extended CO distribution is consistent with an approximately 8 kpc diameter crescent-shaped ring of molecular gas, similar to the one seen in H I, accounting for approximately half of the total CO flux. Assuming this distribution, we derive a total H2 mass for NGC 2445 of 0.4-2.4 x 10(exp 10) solar mass, depending on whether a Galactic or low-metallicity Large Magellanic Cloud (LMC) conversion factor is used, and an H2/H I mass ratio between 0.9 and 5. The ring is experiencing low rates of massive star formation despite very high gas column densities. We find that the gas surface density exceeds the critical threshold for star formation throughout the ring, even without a possible contribution from a significant molecular component. The absence of vigorous star formation is most simply understood in terms of its youth (approximately 30 Myr): massive stars have not had time to form in large numbers. Our results support the interpretation that NGC 2445 is a nascent ring galaxy, seen prior to its ring starburst phase.

Higdon, James L.↗

An investigation to determine the pressure distribution on the 0.0137 scale solid rocket booster forebody (MSFC model 467) at angles of attack at or near 90 deg and high Reynolds numbers in the MSFC High Reynolds Number Wind Tunnel (SA29F)

An aerodynamic investigation was conducted in the MSFC High Reynolds Number Wind Tunnel to determine the pressure distribution over the foresection of the current 146 inch diameter shuttle SRB. The test model consisted of a 0.0137 scale version of the SRB nose cone and a forward portion of the cylindrical body which was approximately 2.7 calibers in length. The pressure distributions are plotted as a function of longitudinal station ratioed to body diameter and circumferential location for each angle of attack and Mach number. A Reynolds number variation study was made for Mach numbers of 0.4 and 0.6 at an angle of attack of 270 deg and roll angle of 180 deg.

Ramsey, P. E.↗

Alma resolves the torus of NGC 1068: continuum and molecular line emission

We used the Atacama Large Millimeter Array (ALMA) to map the emission of the CO(6–5) molecular line and the 432 μm continuum emission from the 300 pc sized circumnuclear disk (CND) of the nearby Seyfert 2 galaxy NGC 1068 with a spatial resolution of ∼4 pc. These observations spatially resolve the CND and, for the first time, image the dust emission, the molecular gas distribution, and the kinematics from a 7–10 pc diameter disk that represents the submillimeter counterpart of the putative torus of NGC 1068. We fitted the nuclear spectral energy distribution of the torus using ALMA and near- and mid-infrared (NIR/MIR) data with CLUMPY torus models. The mass and radius of the best-fit solution for the torus are both consistent with the values derived from the ALMA data alone: M{sub gas}{sup torus}=(1±0.3)×10{sup 5} M{sub ⊙} and R {sub torus} = 3.5 ± 0.5 pc. The dynamics of the molecular gas in the torus show strong non-circular motions and enhanced turbulence superposed on a surprisingly slow rotation pattern of the disk. By contrast with the nearly edge-on orientation of the H{sub 2}O megamaser disk, we found evidence suggesting that the molecular torus is less inclined (i = 34°–66°) at larger radii. The lopsided morphology and complex kinematics of the torus could be the signature of the Papaloizou–Pringle instability, long predicted to likely drive the dynamical evolution of active galactic nuclei tori.

79 ASTRONOMY AND ASTROPHYSICS↗

Thickness of Ridged Plains Materials in Hesperia Planum, Mars

The thickness distribution of plains-forming materials in Hesperia Planum is determined by the diameter of partially buried craters. As with all Martian thickness studies, the distribution of measured thicknesses is sparse due to a low number of suitable partially buried craters. The resulting isopach of plains materials has a low level of confidence but is sufficient for generalized thickness trends. The mean of the thickness estimates is 360 + or - 120 m. The isopach of plains-forming materials exhibits an uneven thickness distribution. Average thickness, determined by grid sampling over the region, is 216 + or - 153 m. Local lenses exceed 500 m. A fifth order trend surface provides a partial match (coefficient of correlation = 0.657) to the isopach.

Dehon, R. A.↗

A status review on DNB prediction using CASL baseline boiling model and possible suggestions regarding wall boiling closures

The main goal of FY18 THM’s focus task is to evaluate where the current CASL boiling model stands for DNB predictive performance, to identify which components should be improved or calibrated to enhance DNB performance. Over the past three year’s validation tests, Gen1A boiling model has presented an under-predictive behavior for DNB at the high pressure of interest for PWR application. With this in mind, this year’s task is to focus on 1) best practice guidelines on DNB detection criteria, 2) interfacial momentum transfer closure tests, and 3) wall boiling closure sensitivity on DNB. Best practice guidelines on DNB detection criteria are demonstrated by the following three monitoring variables: 1) max wall temperature, 2) K-value and 3) energy balance. Interfacial momentum transfer closure govern the bubble distribution, especially in lateral direction, as well as bubble mean diameter. A clear correlation between interfacial momentum closure and DNB prediction is not observed in the current tests. However, void distributions are changed with different interfacial momentum closure tests which requires further validation with corresponding experimental measurement. From a variety of wall boiling closure tests, bubble departure diameter seems the most sensitive for DNB performance while fulfilling numerical robustness in DNB simulation. Tolubinski’s bubble departure diameter model was calibrated to see if any improvement is observed in DNB performance. Notable DNB improvement was observed as the bubble departure diameter is reduced. However, reduced bubble departure diameter by calibrated Tolubinski’s model seemed to lead to relatively high wall superheat temperature prediction which requires further validation with associated experimental measurement It should be noted that lack of experimental measurement close to DNB condition hampers this boiling closure sensitivity study significantly. This situation directly reflects some of limitations of the CASL boiling model development. With this in mind, the implementation of improved boiling closure on 5x5 NMVG and MVG tests will be pursued in FY19, the associated DNB best practice guidelines and possible limitations will be addressed for industry DNB application.

42 ENGINEERING↗

Ethanol Blend Effects On Direct Injection Spark-Ignition Gasoline Vehicle Particulate Matter Emissions

Direct injection spark-ignition (DISI) gasoline engines can offer better fuel economy and higher performance over their port fuel-injected counterparts, and are now appearing increasingly in more U.S. vehicles. Small displacement, turbocharged DISI engines are likely to be used in lieu of large displacement engines, particularly in light-duty trucks and sport utility vehicles, to meet fuel economy standards for 2016. In addition to changes in gasoline engine technology, fuel composition may increase in ethanol content beyond the 10% allowed by current law due to the Renewable Fuels Standard passed as part of the 2007 Energy Independence and Security Act (EISA). In this study, we present the results of an emissions analysis of a U.S.-legal stoichiometric, turbocharged DISI vehicle, operating on ethanol blends, with an emphasis on detailed particulate matter (PM) characterization. Gaseous species, particle mass, and particle number concentration emissions were measured for the Federal Test Procedure urban driving cycle (FTP 75) and the more aggressive US06 cycle. Particle number-size distributions and organic to elemental carbon ratios (OC/EC) were measured for 30 MPH and 80 MPH steady-state operation. In addition, particle number concentration was measured during wide open throttle accelerations (WOTs) and gradual accelerations representative of the FTP 75. For the gaseous species and particle mass measurements, dilution was carried out using a full flow constant volume sampling system (CVS). For the particle number concentration and size distribution measurements, a micro-tunnel dilution system was employed. The vehicles were fueled by a standard test gasoline and 10% (E10) and 20% (E20) ethanol blends from the same supplier. The particle mass emissions were approximately 3 and 7 mg/mile for the FTP75 and US06, respectively, with lower emissions for the ethanol blends. During steady-state operation, the geometric mean diameter of the particle-number size distribution remained approximately the same (50 nm) but the particle number concentration decreased with increasing ethanol content in the fuel. In addition, increasing ethanol content significantly reduced the number concentration of 50 and 100 nm particles during gradual and WOT accelerations.

02 PETROLEUM↗

A Novel Sustainable Process for Multilayer Graphene Synthesis Using CO 2 from Ambient Air

Graphene produced by different methods can present varying physicochemical properties and quality, resulting in a wide range of applications. The implementation of a novel method to synthesize graphene requires characterizations to determine the relevant physicochemical and functional properties for its tailored application. We present a novel method for multilayer graphene synthesis using atmospheric carbon dioxide with characterization. Synthesis begins with carbon dioxide sequestered from air by monoethanolamine dissolution and released into an enclosed vessel. Magnesium is ignited in the presence of the concentrated carbon dioxide, resulting in the formation of graphene flakes. These flakes are separated and enhanced by washing with hydrochloric acid and exfoliation by ammonium sulfate, which is then cycled through a tumble blender and filtrated. Raman spectroscopic characterization, FTIR spectroscopic characterization, XPS spectroscopic characterization, SEM imaging, and TEM imaging indicated that the graphene has fifteen layers with some remnant oxygen-possessing and nitrogen-possessing functional groups. The multilayer graphene flake possessed particle sizes ranging from 2 µm to 80 µm in diameter. BET analysis measured the surface area of the multilayer graphene particles as 330 m 2 /g, and the pore size distribution indicated about 51% of the pores as having diameters from 0.8 nm to 5 nm. This study demonstrates a novel and scalable method to synthesize multilayer graphene using CO 2 from ambient air at 1 g/kWh electricity, potentially allowing for multilayer graphene production by the ton. The approach creates opportunities to synthesize multilayer graphene particles with defined properties through a careful control of the synthesis parameters for tailored applications.

36 MATERIALS SCIENCE↗

Measurements of Local Heat Transfer and Pressure on Six 2-Inch-Diameter Blunt Bodies at a Mach Number of 4.95 and at Reynolds Numbers Per Foot up to 81 x 10(exp 6)

Measurements of the local heat transfer and pressure distribution have been made on six 2-inch-diameter, blunt, axially symmetric bodies in the Langley gas dynamics laboratory at a Mach number of 4.95 and at Reynolds numbers per foot up to 81 x 10(exp 6). During the investigation laminar flow was observed over a hemispherical-nosed body having a surface finish from 10 to 20 microinches at the highest test Reynolds number per foot (for this configuration) of 77.4 x 10(exp 6). Though it was repeatedly possible to measure completely laminar flow at this Reynolds number for the hemisphere, it was not possible to observe completely laminar flow on the flat-nosed body for similar conditions. The significance of this phenomenon is obscured by the observation that the effects of particle impacts on the surface in causing roughness were more pronounced on the flat-nosed body. For engineering purposes, a method developed by M. Richard Dennison while employed by Lockheed Aircraft Corporation appears to be a reasonable procedure for estimating turbulent heat transfer provided transition occurs at a forward location on the body. For rearward-transition locations, the method is much poorer for the hemispherical nose than for the flat nose. The pressures measured on the hemisphere agreed very well with those of the modified Newtonian theory, whereas the pressures on all other bodies, except on the flat-nosed body, were bracketed by modified Newtonian theory both with and without centrifugal forces. For the hemisphere, the stagnation-point velocity gradient agreed very well with Newtonian theory. The stagnation-point velocity gradient for the flat- nosed model was 0.31 of the value for the hemispherical-nosed model. If a Newtonian type of flow is assumed, the ratio 0.31 will be independent of Much number and real-gas effects.

Cooper, Morton↗

Distribution of air-water mixtures in parallel vertical channels as an effect of the header geometry

Uneven phase distribution in heat exchangers is a cause of severe reductions in thermal performances of refrigeration equipment. To date, no general design rules are available to avoid phase separation in manifolds with several outlet channels, and even predicting the phase and mass distribution in parallel channels is a demanding task. In the present paper, measurements of two-phase air-water distributions are reported with reference to a horizontal header supplying 16 vertical upward channels. The effects of the operating conditions, the header geometry and the inlet port nozzle were investigated in the ranges of liquid and gas superficial velocities of 0.2-1.2 and 1.5-16.5 m/s, respectively. Among the fitting devices used, the insertion of a co-axial, multi-hole distributor inside the header confirmed the possibility of greatly improving the liquid and gas flow distribution by the proper selection of position, diameter and number of the flow openings between the supplying distributor and the system of parallel channels connected to the header. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-Situ Microphysics from the RACORO IOP

These files were generated by Greg McFarquhar and Robert Jackson at the University of Illinois. Please contact mcfarq@atmos.uiuc.edu or rjackso2@atmos.uiuc.edu for more information or for assistance in interpreting the content of these files. We highly recommend that anyone wishing to use these files do so in a collaborative endeavor and we welcome queries and opportunities for collaboration. There are caveats associated with the use of the data which are difficult to thoroughly document and not all products for all time periods have been thoroughly examined. This is a value added data set of the best estimate of cloud microphysical parameters derived using data collected by the cloud microphysical probes installed on the Center for Interdisciplinary Remotely-Piloted Aircraft Studies (CIRPAS) Twin Otter during RACORO. These files contain best estimates of liquid size distributions N(D) in terms of droplet diameter D, liquid water content LWC, extinction of liquid drops beta, effective radius of cloud drops (re), total number concentration of droplets NT, and radar reflectivity factor Z at 1 second resolution.

54 ENVIRONMENTAL SCIENCES↗

Distribution and histologic effects of intravenously administered amorphous nanosilica particles in the testes of mice

Highlights: Black-Right-Pointing-Pointer There is rising concern regarding the potential health risks of nanomaterials. Black-Right-Pointing-Pointer Few studies have investigated the effect of nanomaterials on the reproductive system. Black-Right-Pointing-Pointer Here, we evaluated the intra-testicular distribution of nanosilica particles. Black-Right-Pointing-Pointer We showed that nanosilica particles can penetrate the blood-testis barrier. Black-Right-Pointing-Pointer These data provide basic information on ways to create safer nanomaterials. -- Abstract: Amorphous nanosilica particles (nSP) are being utilized in an increasing number of applications such as medicine, cosmetics, and foods. The reduction of the particle size to the nanoscale not only provides benefits to diverse scientific fields but also poses potential risks. Several reports have described the in vivo and in vitro toxicity of nSP, but few studies have examined their effects on the male reproductive system. The aim of this study was to evaluate the testicular distribution and histologic effects of systemically administered nSP. Mice were injected intravenously with nSP with diameters of 70 nm (nSP70) or conventional microsilica particles with diameters of 300 nm (nSP300) on two consecutive days. The intratesticular distribution of these particles 24 h after the second injection was analyzed by transmission electron microscopy. nSP70 were detected within sertoli cells and spermatocytes, including in the nuclei of spermatocytes. No nSP300 were observed in the testis. Next, mice were injected intravenously with 0.4 or 0.8 mg nSP70 every other day for a total of four administrations. Testes were harvested 48 h and 1 week after the last injection and stained with hematoxylin-eosin for histologic analysis. Histologic findings in the testes of nSP70-treated mice did not differ from those of control mice. Taken together, our results suggest that nSP70 can penetrate the blood-testis barrier and the nuclear membranes of spermatocytes without producing apparent testicular injury.

60 APPLIED LIFE SCIENCES↗