Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Four-color infrared bolometer system for one-meter telescope

A far-infrared photometer has been developed as a focal plane instrument for a balloon-borne 102-cm telescope. The four gallium-doped Ge bolometers adopted for the system operate at 1.8 K in a liquid-helium dewar. Wavelength bands of the four-bolometer system are a narrow spectrum between 18 and 22 microns, and bands centered at 42, 70, and 140 microns. The responsivity and Johnson noise of the detectors limit the performance of the instrument.

Daneu, V.↗

The physics of heterodyne detection in the far-infrared: Transition from electric-field to photon-absorption detection in a simple system

The history of heterodyne detection is reviewed from the radiowave to the optical regions of the electromagnetic spectrum with emphasion the submillimeter/far infrared. The transition from electric field to photon absorption detection in a simple system is investigated. The response of an isolated two level detector to a coherent source of incident radiation is calculated for both heterodyne and video detection. When the processes of photon absorption and photon emission cannot be distinguished, the relative detected power at double- and sum-frequencies is found to be multiplied by a coefficient, which is less than or equal to unity, and which depends on the incident photon energy and on the effective temperature of the system.

Teich, M. C.↗

CCD charge collection efficiency and the photon transfer technique

The charge-coupled device (CCD) has shown unprecendented performance as a photon detector in the areas of spectral response, charge transfer, and readout noise. Recent experience indicates, however, that the full potential for the CCD's charge collection efficiency (CCE) lies well beyond that which is realized in currently available devices. A definition of CCE performance is presented and a standard test tool (the photon transfer technique) for measuring and optimizing this important CCD parameter is introduced. CCE characteristics for different types of CCDs are compared; the primary limitations in achieving high CCE performance are discussed, and the prospects for future improvement are outlined.

Janesick, J.↗

The interstellar carbon abundance. II - Rho Ophiuchi and Beta Scorpii

A procedure designed to obtain increased sensitivity from high-dispersion IUE spectra by using a flat-field spectrum to remove nonrandom noise due to the response pattern of the SEC vidicon detector is described. Application of this procedure to spectra of Rho Oph and Beta(1) Sco near the spin-forbidden interstellar 2325 line of C II yields 2 sigma upper limits on absorption of W (lambda) not greater than about 4 mA. The resulting depletion of carbon from the interstellar gas toward Rho Oph exceeds a factor of 1.4.

Welty, D. E.↗

Common but unappreciated sources of error in one, two, and multiple-color pyrometry

The most common sources of error in optical pyrometry are examined. They can be classified as either noise and uncertainty errors, stray radiation errors, or speed-of-response errors. Through judicious choice of detectors and optical wavelengths the effect of noise errors can be minimized, but one should strive to determine as many of the system properties as possible. Careful consideration of the optical-collection system can minimize stray radiation errors. Careful consideration must also be given to the slowest elements in a pyrometer when measuring rapid phenomena.

Spjut, R. Erik↗

Review of AMCID technology

Some advantages are given of the basic AMCID configuration. The spectral response is diagrammed of doped silicon detectors.

Parry, C. M.↗

Hard X-Ray Measurements of Polycapillary Optics for Astronomy

Results from hard x-ray tests of a polycapillary optic will be presented. A prototype polycapillary optic consisting of about 2500 individual capillary bundles was provided by X-ray Optical Systems, Inc. The optic was tested at the 100m-long stray-light facility at Marshall Space Flight Center over the 8-50 keV energy band using a CZT detector. Significantly improved high-energy response was observed over previous versions. Implications of these results for future balloon and space astronomy missions will also be reviewed.

Kolodziejczak, Jeffery J.↗

On the Dome Effect of Flux Radiometers to Radiative Forcing

Since the introduction of thermopile, pyranometers (solar, e.g., 0.3-3.0 micrometers) and pyrgeometers (terrestrial, e.g., 4-50 micrometers) have become instruments commonly used for measuring the broadband hemispherical irradiances at the surface in a long-term, monitoring mode for decades. These commercially available radiometers have been manufactured in several countries such as from the United States, Asia, and Europe, and are generally reliable and economical. These worldwide distributions of surface measurements become even more important in the era of Earth remote sensing in studying climate forcing. However, recent studies from field campaigns have pointed out that erroneous factors (e.g., temperature gradients between the filter dome and detector, emissivity of the thermopile) are responsible for the unacceptable level of uncertainty (e.g., 10-20 W m (exp -2)). Using a newly developed instrument of Quantum Well Infrared Photodetector (QWIP), we have characterized the brightness temperature fields of pyranometers and pyrgeometers under various sky conditions. The QWIP is based on the superlattice (GaAs/AlGaAs) technology and has a noise equivalent temperature (NE delta T) less than 0.1 K. The quality of pyranometer and pyrgeometer measurements can be improved largely by applying proper knowledge of the thermal parameters affecting the operation of the thermopile systems. For example, we show a method to determine the "dome factor" (the longwave emission divided by the longwave transmission of a pyrgeometer dome) from field measurements. The results show, and are verified independently by the QWIP, that our dome factors of 0.59 and 0.90 are much smaller than the value of 4.0 assumed by the WMO (World Meteorological Organization). Data correction procedure and algorithm will be presented and discussed.

Tsay, S.-C.↗

On the Dome Effect of Flux Radiometers to Radiative Forcing

Since the introduction of thermopile, pyranometers (solar, e.g., 0.3-3.0 microns) and pyrgeometers (terrestrial, e.g., 4-50 microns) have become instruments commonly used for measuring the broadband hemispherical irradiances at the surface in a long-term, monitoring mode for decades. These commercially available radiometers have been manufactured in several countries such as from the United States, Asia, and Europe, and are generally reliable and economical. These worldwide distributions of surface measurements become even more important in the era of Earth remote sensing in studying climate forcing. However, recent studies from field campaigns have pointed out that erroneous factors (e.g., temperature gradients between the filter dome and detector, emissivity of the thermopile) are responsible for the unacceptable level of uncertainty (e.g., 10-20 W/square Meter). Using a newly developed instrument of Quantum Well Infrared Photodetector (QWIP), we have characterized the brightness temperature fields of pyranometers and pyrgeometers under various sky conditions. The QWIP is based on the superlattice (GaAs/AlGaAs) technology and has a noise equivalent temperature (NE delta T) less than 0.1 K. The quality of pyranometer and pyrgeometer measurements can be improved largely by applying proper knowledge of the thermal parameters affecting the operation of the thermopile systems. For example, we show a method to determine the "dome factor" (the longwave emission divided by the longwave transmission of a pyrgeometer dome) from field measurements. The results show, and are verified independently by the QWIP, that our dome factors of 0.59 and 0.90 are much smaller than the value of 4.0 assumed by the WMO. Data correction procedure and algorithm will be presented and discussed.

Tsay, S.-C.↗

Characterization of Thermal Parameters for Improving Pyranometer and Pyrgeometer Measurements

Since the introduction of thermopile, pyranometers (solar, e.g., 0.3-3.0 micrometers) and pyrgeometers (terrestrial, e.g., 4-50 micrometers) have become instruments commonly used for measuring the broadband hemispherical irradiances at the surface in a long-term, monitoring mode for decades. These commercially available radiometers have been manufactured in several countries such as from the United States, Asia, and Europe, and are generally reliable and economical. These worldwide distributions of surface measurements become even more important in the era of Earth remote sensing in studying climate change. However, recent studies from field campaigns have pointed out that erroneous factors (e.g., temperature gradients between the filter dome and detector, emissivity of the thermopile) are responsible for the unacceptable level of uncertainty (e.g., 20 W m(exp -2)). Using a newly developed instrument of Quantum Well Infrared Photodetector (QWTP), we have characterized the brightness temperature fields of pyranometers and pyrgeometers under various sky conditions. The QWIP is based on the superlattice (GaAs/AlGaAs) technology and has a noise equivalent temperature (NEAT) less than 0.1 K. The quality of pyranometer and pyrgeometer measure- ments can be improved largely by applying proper knowledge of the thermal parameters affecting the operation of the thermopile systems. Data correction procedure and algorithm will be presented and discussed.

Tsay, Si-Chee↗

Thermal Characteristics of Pyranometers and Pyrgeometers in Atmosphere-Surface Energetic Measurements

Since the introduction of thermopile, pyranometers (solar, e.g., 0.3 - 3.0 microns) and pyrgeometers (terrestrial, e.g., 4 - 50 microns) have become instruments commonly used for measuring the broadband hemispherical irradiances at the surface in a long-term, monitoring mode for decades. These commercially available radiometers have been manufactured in several countries such as from the United States, Asia, and Europe, and are generally reliable and economical. These worldwide distributions of surface measurements become even more important in the era of Earth remote sensing in studying climate change. However, recent studies from field campaigns have pointed out that erroneous factors (e.g., temperature gradients between the filter dome and detector, emissivity of the thermopile) are responsible for the unacceptable level of uncertainty (e.g., 20 W/sq m). It is best to utilize an energy balance equation to describe the thermal dome effect of pyranometers and pyrgeometers. Therefore, quality of pyranometer and pyrgeometer measurements can be improved largely by applying proper knowledge of the thermal parameters affecting the operation of the thermopile systems. Data correction procedure and algorithm will be presented and discussed.

Tsay, Si-Chee↗

Reducing Stray Light To Characterize Nirspec Subsystems: The Focal Plane Array And Micro-Shutter Array

The James Webb Space Telescope (JWST) is an infrared, space-based telescope scheduled for launch in 2013. JWST includes four scientific instruments, including the Near Infrared Spectrometer (NIRSpec), which operates in the wavelength range from 0.6 to 5 microns. NASA/Goddard Space Flight Center (GSFC) is responsible for two NIRSpec subsystems: the detector subsystem, with its focal plane array (FPA), and the micro-shutter subsystem, with its micro-shutter array (MSA). The FPA is comprised of two side-by-side Rockwell Scientific HgCdTe 2kx2k detectors, with detectors and readout electronics optimized for low noise. The MSA is a GSFC developed micro-electro-mechanical system (MEMS) that serves as a programmable slit mask, allowing NIRSpec to obtain simultaneous spectra of >100 objects in a single field of view. We present the optical characterization test plan of the FPA. The test plan is driven by many requirements: cryogenic operating temperature, a flight-like beam shape, and multi-wavelength photon flux from 1 to 60,000 per second, thus low stray light is critical. We use commercial optical modeling software to predict stray light effects at the FPA. We also present the optical contrast test plan of the MSA. Since each individual shutter element operates in on/off fashion, the most important optical metric is contrast. The MSA structure is designed to minimize stray and scattered light, and the test setup reduces stray light such that the optical contrast requirement is met.

Connelly, Joseph A.↗

Expected Performance of the GLAST Burst Monitor

The GLAST Burst Monitor (GBM) will enhance LAT observations of GRBs by extending the spectral coverage from the LAT threshold down to approx. 8 kev, and will provide a trigger for re-orienting the spacecraft to observe delayed emission from selected bursts outside the LAT field of view. GBM consists of twelve NaI scintillation detectors operating in the 8 kev to 1 MeV energy range and two BGO scintillation detectors operating in the 150 keV to 30 MeV energy range. Detector resolution, effective area, and angular response have been determined by calibrations. Analyses indicate that the on-board burst threshold will be approx. 0.7 photon/cm2/s and the on-board burst localization accuracy will typically be better than 8 degrees.

Meegan, Charles↗

Mitigating Photon Jitter in Optical PPM Communication

A theoretical analysis of photon-arrival jitter in an optical pulse-position-modulation (PPM) communication channel has been performed, and now constitutes the basis of a methodology for designing receivers to compensate so that errors attributable to photon-arrival jitter would be minimized or nearly minimized. Photon-arrival jitter is an uncertainty in the estimated time of arrival of a photon relative to the boundaries of a PPM time slot. Photon-arrival jitter is attributable to two main causes: (1) receiver synchronization error [error in the receiver operation of partitioning time into PPM slots] and (2) random delay between the time of arrival of a photon at a detector and the generation, by the detector circuitry, of a pulse in response to the photon. For channels with sufficiently long time slots, photon-arrival jitter is negligible. However, as durations of PPM time slots are reduced in efforts to increase throughputs of optical PPM communication channels, photon-arrival jitter becomes a significant source of error, leading to significant degradation of performance if not taken into account in design. For the purpose of the analysis, a receiver was assumed to operate in a photon- starved regime, in which photon counts follow a Poisson distribution. The analysis included derivation of exact equations for symbol likelihoods in the presence of photon-arrival jitter. These equations describe what is well known in the art as a matched filter for a channel containing Gaussian noise. These equations would yield an optimum receiver if they could be implemented in practice. Because the exact equations may be too complex to implement in practice, approximations that would yield suboptimal receivers were also derived.

Moision, Bruce↗

Sub-micron surface plasmon resonance sensor systems

A sensor for detecting the presence of a target analyte, ligand or molecule in a test fluid, comprising a light transmissive substrate on which an array of surface plasmon resonant (SPR) elements is mounted is described. A multi-channel sensor for detecting the presence of several targets with a single micro-chip sensor is described. A multi-channel sensor including collections of SPR elements which are commonly functionalized to one of several targets is also described. The detectors sense changes in the resonant response of the SPR elements indicative of binding with the targets.

Glazier, James A.↗

Sub-micron surface plasmon resonance sensor systems

A sensor for detecting the presence of a target analyte, ligand or molecule in a test fluid, comprising a light transmissive substrate on which an array of surface plasmon resonant (SPR) elements is mounted is described. A multi-channel sensor for detecting the presence of several targets with a single microchip sensor is described. A multi-channel sensor including collections of SPR elements which are commonly functionalized to one of several targets is also described. The detectors sense changes in the resonant response of the SPR elements indicative of binding with the targets.

Glazier, James A.↗

Sub-micron surface plasmon resonance sensor systems

A sensor for detecting the presence of a target analyte, ligand or molecule in a test fluid, comprising a light transmissive substrate on which an array of surface plasmon resonant (SPR) elements is mounted is described. A multi-channel sensor for detecting the presence of several targets with a single micro-chip sensor is described. A multi-channel sensor including collections of SPR elements which are commonly functionalized to one of several targets is also described. The detectors sense changes in the resonant response of the SPR elements indicative of binding with the targets.

Glazier, James A.↗

Sub-micron surface plasmon resonance sensor systems

A sensor for detecting the presence of a target analyte, ligand or molecule in a test fluid, comprising a light transmissive substrate on which an array of surface plasmon resonant (SPR) elements is mounted is described. A multichannel sensor for detecting the presence of several targets with a single microchip sensor is described. A multichannel sensor including collections of SPR elements which are commonly functionalized to one of several targets is also described. The detectors sense changes in the resonant response of the SPR elements indicative of binding with the targets.

Glazier, James A.↗