Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Dynamic-Range Compression For Infrared Imagery

Photorefractive crystals covering detectors prevent saturation. To make full use of information in image, desirable to compress dynamic range of input intensity to within region of approximately linear response of detector. Dynamic-range compression exhibited by measurements of attenuation in photorefractive GaAs. Effective dynamic-range-compressor plate, film, or coating reduces apparent contrast of scene imaged on detector plane to within dynamic range of detectors; original image contrast or intensity data recovered subsequently in electronic image processing because range-compression function and inverse known.

Cheng, Li-Jen↗

Performance of high resolution decoding with Multi-Anode Microchannel Array detectors

The Multi-Anode Microchannel Array (MAMA) is a microchannel plate based photon counting detector with applications in ground-based and space-based astronomy. The detector electronics decode the position of each photon event, and the decoding algorithm that associates a given event with the appropriate pixel is determined by the geometry of the anode array. The standard MAMA detector has a spatial resolution set by the anode array of 25 microns, but the MCP pore resolution exceeds this. The performance of a new algorithm that halves the pixel spacing and improves the pixel spatial resolution is described. The new algorithm does not degrade the pulse-pair resolution of the detector and does not require any modifications to the detector tube. Measurements of the detector's response demonstrate that high resolution decoding yields a 60 percent enhancement in spatial resolution. Measurements of the performance of the high resolution algorithm with a 14 micron MAMA detector are also described. The parameters that control high resolution performance are discussed. Results of the application of high resolution decoding to speckle interferometry are presented.

Kasle, David B.↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broad band X-ray astronomical spectroscopy

The Broad Band X-Ray Telescope (BBXRT) experiment has been designed for high sensitivity, moderate resolution spectrophotometry of cosmic sources in the range 0.5 to 12 keV. Principal elements are two co-aligned imaging telescopes with cooled Si(Li) detectors at each focus. The mirror design uses an approximate geometry of tightly nested, conical, foil reflectors that allow a large filling factor (high throughput) at small grazing angles (high energy response). Each detector consists of a cluster of five elements defined with grooves on a single crystal. This arrangement affords some spatial resolution as well as a means of substantial background reduction. Shuttle borne measurements will typically be of 2000 s duration for sources with a flux of 10 to the -12 erg/sq cm-s.

Serlemitsos, P. J.↗

Study of perovskite CsPbBr 3 detector polarization and its mitigation with ultrahigh x-ray flux

High-flux capable semiconductor x-ray detectors are essential in various applications, but the detrimental effects of detector polarization limit their use in many cases. Here, for this work, we studied the polarization of perovskite CsPbBr 3 semiconductor detectors using ultrahigh flux synchrotron x rays (10 6 –10 12 photons s –1 mm –2 at 58.61 keV). The CsPbBr 3 detectors did not show immediate polarization prominently until a flux higher than 10 10 photons s –1 mm –2 . Using the pump-and-probe technique, we visualized the spatial and temporal effects of polarization. The polarized region, represented by reduced photocurrent, extended beyond the area under direct irradiation, and the reduced photocurrent persisted after potential de-polarization treatments. We found that stronger applied electric fields and fewer carrier traps can mitigate polarization, represented by less photocurrent deficit. By examining the detectors’ current response under controlled ambient light, low, and high-flux x rays, we studied the trap filling and release behavior of CsPbBr 3 . We discovered that the polarization is caused by partial detector damage due to deep defects generated by ultrahigh flux x-ray irradiation. Our work provides insight into CsPbBr 3 polarization under extremely intense x-ray radiation and shows that reducing crystal defects and increasing detector bias voltage are effective solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Test results from a comparative evaluation of a condensation nuclei fire detector

The fire/smoke alarm response of a condensation nuclei fire detector (CNFD) was compared with photoelectric and ionization detectors. Tests were conducted in a former control room 8.5 m by 8.9 with a 2.7 m ceiling. The room had air supplied from above the ceiling and under the floor with return air exiting from ceiling grills. The environment was varied from 278 to 305 K and relative humidities from 8 to 65%. Four detection zones were located in the room. Each zone contained a sampling head for the CNDF, a photodetector, and an ionization detector so that each detector system had four opportunities to alarm during tests. The particle level in the test room was also monitored during tests with a condensation nuclei particle counter. The CNFD responded to 90% of exposures to smoldering plastic and 84% of exposures to visible fire. The photoelectric response was 43 and 12.5% respectively for the same conditions. The ionization response was 9 and 48 respectively.

Bricker, R. W.↗

Gamma-ray Exportable Adjustable Spectrum Evolution

An initial number of fissions on a fissile/fissionable material, defined by ENDF library availability, is used to produce an initial inventory of fission products (FPs). The FPs are decayed using full, analytical solutions to the Bateman equations to calculate the FP inventory at a user-specified time. The radiation detector, a high-purity germanium (HPGe) detector, has been modeled using every gamma-ray in the ENDF/TENDL libraries individually, and the modeled response can be multiplied by the activity of each fission product to determine a full, energy dependent detector response, including dead time. The detector response can be output as a PeakEasy (.spe) file, or as a text file. Since each radioisotope's inventory is known, the proportion to the total may be shown for each isotope, as well as many radionuclides in a user-specified energy window. Full execution and display of results takes 1-3 seconds, depending on the complexity of the input parameters.

Holschuh, ThomasV [Idaho National Laboratory (INL)↗

Characterization of Partial Charge Collection Induced by Neutron Damage in High-Purity Germanium Detectors

This paper investigates the correlation of damage induced by neutron interactions and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the observed energy spectrum. The partial charge collection produces observable spectral changes by increasing the peak width and reducing resolution (full width half maximum). A detailed characterization using various check sources was performed before and after iterations of neutron exposure in order to observe the effects of the neutron damage. An additional set of measurements was performed along with characterizations to show the detector’s response at discrete locations on the HPGe crystal. This was done to observe how the spectrum changes when the gamma rays are isolated to regions of various thicknesses of germanium. In order to impart damage, the detector was placed inside a californium shuffler with the face of the detector against the guide tube for the 252 Cf source. For irradiation of the HPGe, the source was then positioned in front of the face of the detector using the stepper motor of the shuffler. The neutron exposure time intervals were recorded and increased based on the initial damage observed. An MCNP simulation was performed to estimate the amount of interactions that occurred in the germanium crystal to ensure enough damage had occurred. Studying the effects that neutron damage imparts on a bullet-type HPGe detector can help provide necessary data to estimate total neutron exposure limits, reduce the likelihood of decisions made on suspect data, and aid in diagnostics of a damaged detector.

36 MATERIALS SCIENCE↗

MODIS Detector Differences Using Deep Convective Clouds and Desert Targets

An accurate on-orbit characterization of the Moderate Resolution Imaging Spectroradiometer (MODIS) sensors onboard the Terra and Aqua satellites is essential to satisfy the requirements from the scientific community for high-quality operational and research products. In this study, NASA’s C6.1 L1B data are utilized to assess the stability of the calibrated top of atmosphere reflectance retrieved from individual detectors within a spectral band over deep convective clouds (DCCs) and desert sites. The results from these invariant Earth targets show detector-to-detector (D2D) differences in the L1B reflectance products for select MODIS reflective solar bands. For Aqua MODIS, the D2D differences have no significant change over time for the bands studied. However, the D2D differences exhibit an increase in magnitude over time for Terra MODIS bands 1, 3-7, and 26, which can induce noticeable striping and higher uncertainties in the downstream data products. The D2D stability assessment results over DCCs are consistent with those observed over desert sites. In addition, the view-angle dependence of the D2D differences is investigated by separating the frames along scan into five zones. The D2D assessment is performed for each of the five zones, and the results will further benefit any improvements in the calibration of a detector-dependent response versus scan angle that can be considered for future MODIS Level 1B Collections.

MODIS↗

The response of a 0.03-cm silicon detector to a mixed neutron and gamma field as a function of shield material and thickness

The neutron and gamma radiation from a MHW-RTG was used to evaluate the total response of a shielded 0.3-mm silicon detector. The generator employs a 2200 W(th) PuO2 heat source concept known as the HELIPAK. The total integrated neutron and gamma ray fluxes at 100 cm away from the source along the radial direction were 1.67 x 1,000 n/sq cm/s and 1.49 x 10,000 gamma sq cm/s, respectively. Experimental values of the response function of the shielded silicon detector were used to determine the total counting rates due to photons at bias energies ranging from 50 to 200 keV. For neutrons, analytically computed response functions were used to determine the total counting rates at the same bias energies. It was found that for an aluminum shield the neutrons are not significant, regardless of the thickness of the shield. However, the magnitude of the total counting rate due to neutrons increases with increased atomic number of the shield and becomes comparable to the counting rate due to photons for a platinum shield thickness of 5 cm.

Taherzadeh, M.↗

The cosmic muon and detector simulation framework of the extreme energy events (EEE) experiment

Abstract This paper describes the simulation framework of the extreme energy events (EEE) experiment. EEE is a network of cosmic muon trackers, each made of three multi-gap resistive plate chambers (MRPC), able to precisely measure the absolute muon crossing time and the muon integrated angular flux at the ground level. The response of a single MRPC and the combination of three chambers have been implemented in a GEANT4-based framework (GEMC) to study the telescope response. The detector geometry, as well as details about the surrounding materials and the location of the telescopes have been included in the simulations in order to realistically reproduce the experimental set-up of each telescope. A model based on the latest parametrization of the cosmic muon flux has been used to generate single muon events. After validating the framework by comparing simulations to selected EEE telescope data, it has been used to determine detector parameters not accessible by analysing experimental data only, such as detection efficiency, angular and spatial resolution.

Abbrescia, M.↗

NPP VIIRS Geometric Performance Status

Visible Infrared Imager Radiometer Suite (VIIRS) instrument on-board the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP) satellite is scheduled for launch in October, 2011. It is to provide satellite measured radiance/reflectance data for both weather and climate applications. Along with radiometric calibration, geometric characterization and calibration of Sensor Data Records (SDRs) are crucial to the VIIRS Environmental Data Record (EDR) algorithms and products which are used in numerical weather prediction (NWP). The instrument geometric performance includes: 1) sensor (detector) spatial response, parameterized by the dynamic field of view (DFOV) in the scan direction and instantaneous FOV (IFOV) in the track direction, modulation transfer function (MTF) for the 17 moderate resolution bands (M-bands), and horizontal spatial resolution (HSR) for the five imagery bands (I-bands); 2) matrices of band-to-band co-registration (BBR) from the corresponding detectors in all band pairs; and 3) pointing knowledge and stability characteristics that includes scan plane tilt, scan rate and scan start position variations, and thermally induced variations in pointing with respect to orbital position. They have been calibrated and characterized through ground testing under ambient and thermal vacuum conditions, numerical modeling and analysis. This paper summarizes the results, which are in general compliance with specifications, along with anomaly investigations, and describes paths forward for characterizing on-orbit BBR and spatial response, and for improving instrument on-orbit performance in pointing and geolocation.

Lin, Guoqing↗

Neutron Calibration Studies for the SuperCDMS SNOLAB Experiment

My time at Fermilab has been dedicated to advancing the field of dark matter detection through my contributions to the SuperCDMS collaboration. The first project involved the development and testing of a delivery system for a Cf-252 neutron source to calibrate the SuperCDMS silicon and germanium detectors. Subsequently, I focused on parametrizing the detectors' instrumental response by optimizing a plastic scintillator backing array to measure the scattering angle of a collimated neutron beam. The Monte Carlo simulation I designed provided insights into the detection efficiency of the array, and the best-fit design I arrived at for the scattering counters will be implemented into the final array. Additionally, I assembled a muon detector with legacy hardware to enhance the ability of the calibration experiment to reduce dark current and false signals. As my work nears completion, I am confident that these contributions will significantly enhance the precision and reliability of the SuperCDMS experiment, pushing the boundaries of our understanding of dark matter and contributing to the broader scientific community's quest to unravel the mysteries of the universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton Quenching in Rare-Earth Inorganic Scintillators: GAGG:Ce and YSO:Ce

Scintillator detectors are an integral component of radiation detection systems for a variety of applications such as medical imaging, accelerator diagnostics, and space science. Typically, a scintillator detector’s response is characterized using gamma sources to understand the detection response to different types of radiation, including charged particle detection. However, there exists a nonlinearity of the amount of light produced from an incident gamma ray of specific energy and the light produced from an incident charged particle of the same energy. This important effect, known as quenching, must be accounted for to interpret energies from charged particles incident on detectors. In this article, we present results of quenching parameterization for two types of cerium-doped inorganic scintillators, Y2SiO5:Ce (YSO:Ce) and Gd3Al2Ga3O12:Ce (GAGG:Ce). We measured the light output from incident proton energies from 1 to 25 MeV using a 3-MV tandem accelerator and two reactions: Au(p,p)Au and 3He(d,p)⁴He. Using gamma-ray sources to calibrate the detectors, we compared the measured electron-equivalent energy versus the incident energy expected. Using an adaptation of the Birks semi-empirical formula, we extracted the Birks parameter (kB) to understand quenching. For one of the GAGG:Ce samples, the kB parameter of 0.0072 [g cm-2 MeV-1] is comparable to a similar study where the value of kB was 0.0065 [g cm-2 MeV-1]. For YSO:Ce, no other kB values were found in the literature. Three different types of GAGG:Ce were used to collect measurements of kB as a function of dopant concentration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heat Transfer Issues in Thin-Film Thermal Radiation Detectors

The Thermal Radiation Group at Virginia Polytechnic Institute and State University has been working closely with scientists and engineers at NASA's Langley Research Center to develop accurate analytical and numerical models suitable for designing next generation thin-film thermal radiation detectors for earth radiation budget measurement applications. The current study provides an analytical model of the notional thermal radiation detector that takes into account thermal transport phenomena, such as the contact resistance between the layers of the detector, and is suitable for use in parameter estimation. It was found that the responsivity of the detector can increase significantly due to the presence of contact resistance between the layers of the detector. Also presented is the effect of doping the thermal impedance layer of the detector with conducting particles in order to electrically link the two junctions of the detector. It was found that the responsivity and the time response of the doped detector decrease significantly in this case. The corresponding decrease of the electrical resistance of the doped thermal impedance layer is not sufficient to significantly improve the electrical performance of the detector. Finally, the "roughness effect" is shown to be unable to explain the decrease in the thermal conductivity often reported for thin-film layers.

Barry, Mamadou Y.↗

Characterization of silicon drift detectors with electrons for the TRISTAN project

Sterile neutrinos are a minimal extension of the standard model of particle physics. A promising model-independent way to search for sterile neutrinos is via high-precision β-spectroscopy. The Karlsruhe tritium neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector’s response to electrons on the final sterile neutrino sensitivity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The pyroelectric properties of TGS for application in infrared detection

The pyroelectric property of triglycine sulfate and its application in the detection of infrared radiation are described. The detectivities of pyroelectric detectors and other types of infrared detectors are compared. The thermal response of a pyroelectric detector element and the resulting electrical response are derived in terms of the material parameters. The noise sources which limit the sensitivity of pyroelectric detectors are described, and the noise equivalent power for each noise source is given as a function of frequency and detector area.

Kroes, R. L.↗