Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Improved Design of Active Pixel CMOS Sensors for Charged Particle Detection

The Department of Energy (DOE) nuclear physics program requires developments in detector instrumentation electronics with improved energy, position and timing resolution, sensitivity, rate capability, stability, dynamic range, and background suppression. The current Phase-I project was focused on analysis of standard-CMOS photogate Active Pixel Sensors (APS) as an efficient solution to this challenge. The advantages of the CMOS APS over traditional hybrid approaches (i.e., separate detection regions bump-bonded to readout circuits) include greatly reduced cost, low power and the potential for vastly larger pixel counts and densities. However, challenges remain in terms of the signal-to-noise ratio (SNR) and readout speed (currently on the order of milliseconds), which is the major problem for this technology. Recent work has shown that the long readout time for photogate APS is due to the presence of (interface) traps at the semiconductor-oxide interface. This Phase-I work yielded useful results in two areas: (a) Advanced three-dimensional (3D) physics-based simulation models and simulation-based analysis of the impact of interface trap density on the transient charge collection characteristics of existing APS structures; and (b) Preliminary analysis of the feasibility of an improved photogate pixel structure (i.e., new APS design) with an induced electric field under the charge collecting electrode to enhance charge collection. Significant effort was dedicated in Phase-I to the critical task of implementing accurate interface trap models in CFDRC's NanoTCAD 3D semiconductor device-physics simulator. This resulted in validation of the new NanoTCAD models and simulation results against experimental (published) data, within the margin of uncertainty associated with obtaining device geometry, material properties, and experimentation details. Analyses of the new, proposed photogate APS design demonstrated several promising trends.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-, Light-Cured Scintillating Plastic for 3D-Printing Applications

Additive manufacturing techniques enable a wide range of possibilities for novel radiation detectors spanning simple to highly complex geometries, multi-material composites, and metamaterials that are either impossible or cost prohibitive to produce using conventional methods. The present work identifies a set of promising formulations of photocurable scintillator resins capable of neutron-gamma pulse shape discrimination (PSD) to support the additive manufacturing of fast neutron detectors. The development of these resins utilizes a step-by-step, trial-and-error approach to identify different monomer and cross-linker combinations that meet the requirements for 3D printing followed by a 2-level factorial parameter study to optimize the radiation detection performance, including light yield, PSD, optical clarity, and hardness. The formulations resulted in hard, clear, PSD-capable plastic scintillators that were cured solid within 10 s using 405 nm light. The best-performing scintillator produced a light yield 83% of EJ-276 and a PSD figure of merit equaling 1.28 at 450–550 keVee.

Frandsen, Brian G. (ORCID:0000000319964320)↗

Silicon vertex tracker for RHIC PHENIX Experiment

The PHENIX experiment at Relativistic Heavy Ion Collider will be equipped with Silicon Vertex tracker to enhance its physics capability. There are four layers of silicon sensor to reconstruct charged tracks with 50 {micro}m resolution of decay length measurement. The VTX surrounds the collision point. The inner two layers and the outer two layers are composed of 30 pixel ladders and 44 stripixel ladders, respectively. We have been developing these detectors and done a performance test with 120 GeV proton beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of Total and Partial Charge-changing Cross Sections for 200-400 MeV/nucleon 12C in Water and Polycarbonate

We have studied charged nuclear fragments produced by 200 - 400 MeV/nucleon carbon ions, interacting with water and polycarbonate, using a newly developed emulsion detector. Total and partial charge-changing cross sections for the production of B, Be, and Li fragments were measured and compared with both previously published measurements, and model predictions. This study is of importance for validating and improving carbon ion therapy treatment planning systems, and for estimating the radiological risks for personnel on space missions, since carbon is a significant component of the Galactic Cosmic Rays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Silicon vertex tracker for RHIC PHENIX experiment

The PHENIX experiment at Relativistic Heavy Ion Collider will be equipped with Silicon Vertex tracker to enhance its physics capability. There are four layers of silicon sensor to reconstruct charged tracks with 50 {micro}m resolution of decay length measurement. The VTX surrounds the collision point. The inner two layers and the outer two layers are composed of 30 pixel ladders and 44 stripixel ladders, respectively. We have been developing these detectors and done a performance test with 120 GeV proton beam.

74 ATOMIC AND MOLECULAR PHYSICS↗

Strontium Iodide Instrument Development for Gamma Spectroscopy and Radioisotope Identification

Development of the Europium-doped Strontium Iodide scintillator, SrI2(Eu), has progressed significantly in recent years. SrI2(Eu) has excellent material properties for gamma ray spectroscopy: high light yield (>80,000 ph/MeV), excellent light yield proportionality, and high effective atomic number (Z=49) for high photoelectric cross-section. High quality 1.5 and 2 diameter boules are now available due to rapid advances in SrI2(Eu) crystal growth. In these large SrI2(Eu) crystals, optical self-absorption by Eu2+ degrades the energy resolution as measured by analog electronics, but we mitigate this effect through on-the-fly correction of the scintillation pulses by digital readout electronics. Using this digital correction technique we have demonstrated energy resolution of 2.9% FWHM at 662 keV for a 4 in3 SrI2(Eu) crystal, over 2.6 inches long. Based on this digital readout technology, we have developed a detector prototype with greatly improved radioisotope identification capability compared to Sodium Iodide, NaI(Tl). The higher resolution of SrI2(Eu) yields a factor of 2 to 5 improvement in radioisotope identification (RIID) error rate compared to NaI(Tl).

energy resolution↗

Straddle Carrier Interface and Dispatching System

SCIDS is the Data Dispatching and Transfer Point (DDTP) component of a straddle carrier-based radiation detection system developed for the DOE Megaports Initiative for scanning shipping containers in transshipment ports. Its purpose is to communicate with a Radiation Detection Straddle Carrier (RDSC) developed by Detector Networks International, sending commands to the RDSC and receiving sensor data from the RDSC. Incoming sensor and status data from the RDSC is forwarded to a back-end data storage and display system that is external to SCIDS. SCIDS provides a graphical user interface for port operations personnel that displays location and status of the RDSC and status of each container in the port, and accepts commands from the operator directing the scanning operations of the RDSC.

Source record↗

Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100$\%$ fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 $\mu$m width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. The experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies to Improve the Sensitivity to Low Energy Interactions in Dual-Phase Xenon Dark Matter Detectors. Department of Energy Office of Science Graduate Student Research (SCGSR) Program, Final project report

Noble liquid time projection chambers (TPCs) are some of the most sensitive particle detectors ever developed. They see use in searches for new physics with neutrinos, or for new particles like dark matter. They work by sensing light and charge signals left behind by particle interactions in a volume of liquified xenon or argon. TPCs are so sensitive that even a single electron liberated in an interaction can be readily detected. However this sensitivity to signals comes with a sensitivity to background noise, with one example being single electrons that arrive long after the signals from a true particle interaction. This type of noise has been the subject of multiple studies, which have concluded that single electron backgrounds are well correlated with prior events in the TPC, as well as impurities in the detection medium. At Lawrence Livermore National Laboratory (LLNL), the XeNu TPC is a testbed for a novel study of these backgrounds by generating data with new components made of aluminum and Shapal--the latter being an exotic ceramic which can be machined using standard tools. These materials were selected to replace plastic components which introduce impurities in the TPC during operation. Without plastic, the hope is that electron backgrounds will be reduced, leaving new opportunities for studying their origins and dependence on impurities. The SCGSR fellowship served as a springboard to help meet these objectives. Over the course of a year, the new components were designed, fabricated, and installed in XeNu. Following their installation, data was taken for use in a future study that will enable the electron background contributions from plastic components to be studied directly. In the interim, preliminary analysis results indicate that electron backgrounds with the new components are roughly 50% lower. This has established the efficacy of Shapal as a low-background replacement for plastic components where electrical and thermal stability are needed

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗