At least 505 records · Page 28

EPR Imaging at a Few Megahertz Using SQUID Detectors

An apparatus being developed for electron paramagnetic resonance (EPR) imaging operates in the resonance-frequency range of about 1 to 2 MHz well below the microwave frequencies used in conventional EPR. Until now, in order to obtain sufficient signal-to-noise radios (SNRs) in conventional EPR, it has been necessary to place both detectors and objects to be imaged inside resonant microwave cavities. EPR imaging has much in common with magnetic resonance imaging (MRI), which is described briefly in the immediately preceding article. In EPR imaging as in MRI, one applies a magnetic pulse to make magnetic moments (in this case, of electrons) precess in an applied magnetic field having a known gradient. The magnetic moments precess at a resonance frequency proportional to the strength of the local magnetic field. One detects the decaying resonance-frequency magnetic- field component associated with the precession. Position is encoded by use of the known relationship between the resonance frequency and the position dependence of the magnetic field. EPR imaging has recently been recognized as an important tool for non-invasive, in vivo imaging of free radicals and reduction/oxidization metabolism. However, for in vivo EPR imaging of humans and large animals, the conventional approach is not suitable because (1) it is difficult to design and construct resonant cavities large enough and having the required shapes; (2) motion, including respiration and heartbeat, can alter the resonance frequency; and (3) most microwave energy is absorbed in the first few centimeters of tissue depth, thereby potentially endangering the subject and making it impossible to obtain adequate signal strength for imaging at greater depth. To obtain greater penetration depth, prevent injury to the subject, and avoid the difficulties associated with resonant cavities, it is necessary to use lower resonance frequencies. An additional advantage of using lower resonance frequencies is that one can use weaker applied magnetic fields: For example, for a resonance frequency of 1.4 MHz, one needs a magnetic flux density of 0.5 Gauss approximately the flux density of the natural magnetic field of the Earth.

Hahn, Inseob↗

Fine-tuning machine-learned particle-flow reconstruction for new detector geometries in future colliders

We demonstrate transfer learning capabilities in a machine-learned algorithm trained for particle-flow reconstruction in high energy particle colliders. This paper presents a cross-detector fine-tuning study, where we initially pretrain the model on a large full simulation dataset from one detector design, and subsequently fine-tune the model on a sample with a different collider and detector design. Specifically, we use the Compact Linear Collider detector (CLICdet) model for the initial training set and demonstrate successful knowledge transfer to the CLIC-like detector (CLD) proposed for the Future Circular Collider in electron-positron mode. We show that with an order of magnitude less samples from the second dataset, we can achieve the same performance as a costly training from scratch, across particle-level and event-level performance metrics, including jet and missing transverse momentum resolution. Furthermore, we find that the fine-tuned model achieves comparable performance to the traditional rule-based particle-flow approach on event-level metrics after training on 100,000 CLD events, whereas a model trained from scratch requires at least 1 million CLD events to achieve similar reconstruction performance. To our knowledge, this represents the first full-simulation cross-detector transfer learning study for particle-flow reconstruction. These findings offer valuable insights towards building large foundation models that can be fine-tuned across different detector designs and geometries, helping to accelerate the development cycle for new detectors and opening the door to rapid detector design and optimization using machine learning.

43 PARTICLE ACCELERATORS↗

Optical detectors for spectroscopy

The modes of operation of photoconductive and photoemissive array detectors are described, and their performance characteristics compared and contrasted, with emphasis on their suitability for use as detectors for optical spectroscopy. The prospects for future developments of the array detectors are discussed.

Timothy, J. G.↗

Scintillator-fiber charged-particle track-imaging detector

A scintillator-fiber charged-particle track-imaging detector has been developed using a bundle of square cross-section plastic scintillator fiber optics, proximity focused onto an image intensified Charge Injection Device (CID) camera. Detector to beams of 15 MeV protons and relativistic Neon, Manganese, and Gold nuclei have been exposed and images of their tracks are obtained. This paper presents details of the detector technique, properties of the tracks obtained, and range measurements of 15 MeV protons stopping in the fiber bundle.

Binns, W. R.↗

Precise pointing of space telescope using a quadrant detector

A study was done to evaluate the pointing performance of Space Telescope with a quadrant detector used as the fine guidance sensor. The detector, a quadrant digicon, has been proposed as a replacement detector should unforeseen problems develop with the present baseline interferometer design. The detector model is discussed along with the experimental data from which it was derived.

Strikwerda, T. E.↗

Measurement of Rayleigh Scattering in Liquid Argon at Vacuum Ultraviolet Wavelengths

Liquid argon based experiments are limited in scintillation light analysis capabilities due to inconsistent measured values of fundamental constants essential for reconstructing scintillation events. This experiment measures the Rayleigh scattering length of vacuum ultraviolet light propagating in liquid argon to support liquid argon experiments by expanding the scope of scintillation signal analysis. Preliminary results are presented for the Rayleigh scattering length in arange of vacuum ultraviolet wavelengths, including the liquid argon scintillation peak wavelength. Currently, further data collection and analysis is required to reduce measurement uncertainty as well as quantify and correct for other effects such as the photon detector temperature dependence. Results will contribute to the development of new photon detector system analysis methods for liquid argon experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.↗

Unsupervised Learning for Improved Gamma-Ray Spectrometry in Pixelated Cadmium Zinc Telluride (CZT) Detectors

Machine learning has been found to be ubiquitously useful across many industries, presenting an opportunity to improve radiation detection performance using data-driven algorithms. Improved detector resolution can aid in the detection, identification, and quantification of radionuclides. Here, in this work, a novel, data-driven, unsupervised learning approach is developed to improve detector spectral characteristics by learning, and subsequently rejecting, poorly performing regions of the pixelated detector. Feature engineering is used to fit individual characteristic photo peaks to a Doniach lineshape with a linear background model. Then, principal component analysis is used to learn a lower-dimension latent space representation of each photo peak where the pixels are clustered, and subsequently ranked, based on the cluster mean distance to an optimal point. Pixels within the worst cluster(s) are rejected to improve the full-width at half-maximum (FWHM) by 10% to 15% (relative to the bulk detector) at 50% net efficiency when applied to training data obtained from measurements of a 100 μCi 154 Eu source using a H3D M400i pixelated cadmium zinc telluride detector. These results compare well with, but do not outperform, a greedy algorithm that accumulates pixels in order of FWHM from lowest to highest used as a benchmark. In the future, this approach can be extended to include the detector energy and angular response. Finally, the model is applied to newly seen natural and enriched uranium spectra relevant for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aerosol Jet Printing on Rigid and Flexible Substrates for Space Applications

Aerosol Jet Printing (AJP) will enable new detector assemblies that were not previously possible with traditional assembly processes. This technology has the potential to reduce mass and volume for fabrication and assembly of detector, instrument and electronics concepts by reducing trace widths down to 10 microns, printing on complex geometries, and allowing new concept production. This presentation summarizes efforts developing AJP for detectors and circuitry for space applications.

Aerosol Jet Printing↗

Benchmarking Simulations of the Compton Spectrometer and Imager with Calibrations

The Compton Spectrometer and Imager (COSI) is a balloon-borne 𝛾-ray (0.2-5 MeV) telescope designed to study astrophysical sources. COSI employs a compact Compton telescope design utilizing 12 high-purity germanium double-sided strip detectors and is inherently sensitive to polarization. In 2016, COSI was launched from Wanaka, New Zealand and completed a successful 46-day flight on NASA’s new Super Pressure Balloon. In order to perform imaging, spectral, and polarization analysis of the sources observed during the 2016 flight, we compute the detector response from well-benchmarked simulations. As required for accurate simulations of the instrument, we have built a comprehensive mass model of the instrument and developed a detailed detector effects engine which applies the intrinsic detector performance to Monte Carlo simulations. The simulated detector effects include energy, position, and timing resolution, thresholds, dead strips, charge sharing, charge loss, crosstalk, dead time, and detector trigger conditions. After including these effects, the simulations closely resemble the measurements, the standard analysis pipeline used for measurements can also be applied to the simulations, and the responses computed from the simulations are accurate. We have computed the systematic error that we must apply to measured fluxes at certain energies, which is 6.3% on a rage. Here we describe the detector effects engine and the benchmarking tests performed with calibrations.

Sleator, Clio C.↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017) (and subsequently titled) Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020) (Final Technical Report)

This is the Final Technical Report for the DoE Measurement Innovation (previously Diagnostic Development) grant DE-SC0006077 titled HIBP Applications to Advance Understanding of Plasma Transport Physics (2011-2017), and subsequently titled Development of Beam Measurements to Advance Understanding of Transients and Improve Validation (2017-2020). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 May 2011–17 July 2020. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that will improve understanding of transport, magnetic equilibrium, and electric fields in magnetically confined plasmas. We have developed novel hardware and advanced techniques to expand beam-based diagnostic capabilities, and extend measurements to new operating regimes. Some have been realized using a Heavy Ion Beam Probe (HIBP) having traditional features, while other applications have joined our innovations with subsets of advantageous HIBP features. This work has established smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key Measurement Innovations include: Computer Models and Simulations of HIBP Applications-Computer modeling and simulating of HIBP applications is central to predicting interaction of beam particles with plasmas, designing diagnostic systems, and anticipating measurement characteristics. We have extended the capability and improved measurement fidelity of the HIBP diagnostic on the Madison Symmetric Torus (MST) reversed field pinch (RFP); simulated feasibility of HIBP operation in the Helically Symmetric eXperiment (HSX) optimized stellarator; and investigated the plausibility of HIBP measurements in the ASDEX Upgrade tokamak. We have also developed a new technique that uses ion optics to model a finite phase-space beam. It yields more realistic (than traditional method) estimates of sample volume characteristics, which influence measurement resolution and sensitivity. Extension of Diagnostic Capabilities and Measurements on the MST RFP-Capabilities have been extended using the first and only HIBP installation on an RFP. Challenges associated with operation of the diagnostic on MST include the three-dimensional nature of particle trajectories, temporal topology and amplitude changes in the plasma equilibrium, and strong particle and radiative emission from the plasma. We have addressed these challenges through development of detailed and higher precision diagnostic simulations, calibrated subtraction of noise to resolve secondary ion signals, and implementation of hardware that enables higher fidelity measurement of plasma fluctuations. Development of New Hardware and Measurement Techniques - We have advanced beam-based measurement capabilities via development of new detectors and techniques to determine the poloidal magnetic flux ψ in the plasma, and enable placement of detectors close to the plasma and thus allow a smaller and less expensive diagnostic. We have demonstrated measurement of ψ, an ability that was made possible by development of highly effective noise reduction techniques. We also modeled the effect of non-ideal and instrumentation effects by developing a virtual (simulated) diagnostic. Application of beam-based diagnostics on various devices and multiple magnetic configurations (e.g. stellarator, tokamak, and reversed field pinch) enables investigation of critical physics issues and measurements resulting in the broad parameter space data needed to test and validate theory & modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Highly Sensitive Multi-Element HgCdTe E-APD Detector for IPDA Lidar Applications

An HgCdTe electron avalanche photodiode (e-APD) detector has been developed for lidar receivers, one application of which is integrated path differential absorption lidar measurements of such atmospheric trace gases as CO2 and CH4. The HgCdTe APD has a wide, visible to mid-wave-infrared, spectral response, high dynamic range, substantially improved sensitivity, and an expected improvement in operational lifetime. A demonstration sensor-chip assembly consisting of a 4.3 lm cutoff HgCdTe 4 9 4 APD detector array with 80 micrometer pitch pixels and a custom complementary metal-oxide-semiconductor readout integrated circuit was developed. For one typical array the APD gain was 654 at 12 V with corresponding gain normalized dark currents ranging from 1.2 fA to 3.2 fA. The 4 9 4 detector system was characterized at 77 K with a 1.55 micrometer wavelength, 1 microsecond wide, laser pulse. The measured unit gain detector photon conversion efficiency was 91.1%. At 11 V bias the mean measured APD gain at 77 K was 307.8 with sigma/mean uniformity of 1.23%. The average, noise-bandwidth normalized, system noise-equivalent power (NEP) was 1.04 fW/Hz(exp 1/2) with a sigma/mean of 3.8%. The measured, electronics-limited, bandwidth of 6.8 MHz was more than adequate for 1 microsecond pulse detection. The system had an NEP (3 MHz) of 0.4 fW/Hz(exp 1/2) at 12 V APD bias and a linear dynamic range close to 1000. A gain-independent quantum-limited SNR of 80% of full theoretical was indicative of a gain-independent excess noise factor very close to 1.0 and the expected APD mode quantum efficiency.

NEP↗

Quantification of LEU Holdup using gamma ray imaging and inverse transport solver

Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Constraining the Beam Neutrino MC Flux Using the MINOS ND Data

This document describes a method to handle correlated systematic uncertainties from hadron production on the beam spectrum by using the neutrino ·data from the MINOS detector. We have developed a tuning function which can be applied after the fact to the Monte Carlo to force agreement with the CC neutrino energy spectra observed in the near detector and the beam MC. The method relies on the flexible NuMI beam, which can be configured so as to selectively sample pions. of different momenta and angles off the target. There is sufficient information in the neutrino data in a detector like MINOS to deduce the portion of the underlying spectrum of hadrons off the NuMI target which contribute to the NuMI flux.

Kopp, Sacha [U. Texas, Austin (main)]↗

Development of 256 x 256 Element Impurity Band Conduction Infrared Detector Arrays for Astronomy

This report describes the work performed on a one and a half year advance technology program to develop Impurity Band Conduction (IBC) detectors with very low dark current, high quantum efficiency, and with good repeatable processes. The program fabricated several epitaxial growths of Si:As detecting layers from 15 to 35 microns thick and analyzed the performance versus the thickness and the Arsenic concentration of these epitaxial layers. Some of the epitaxial runs did not yield because of excessive residual impurities. The thicker epitaxial layers and the ones with higher Arsenic concentration resulted in good detectors with low dark currents and good quantum efficiency. The program hybridized six detector die from the best detector wafers to a low noise, 256 x 256 readout array and delivered the hybrids to NASA Ames for a more detailed study of the performance of the detectors.

Domingo, George↗

Field ionization device used for measuring the pulse height defect of He/+/ in silicon

A neutral particle detector using field ionization and liquid-nitrogen-cooled solid state detectors has been developed to investigate the pulse height defect of low energy He(+) ions in silicon. The field ionization tip is fabricated from a short length of tungsten wire; a typical detector is of the surface-barrier Si type with a thin Au window and low capacitance (about 15 pF); the assembly is mounted in a cylindrical vacuum chamber which is pumped to about 10 to the -6th torr. As an example, pulse height distributions for He(+) and H(+) taken at tip bias of 25.7 kV are presented. The detected energy of the H and He ions are studied as a function of the actual energies of accelerated ions, for a detector having a gold front conducting surface layer of 32 micrograms/sq cm.

Curtis, C. C.↗

Polarized polymer films as electronic pulse detectors of cosmic dust particles

A new type of dust particle detector has been developed which consists of a polarized film of polyvinylidene fluoride (PVDF) having conducting electrons on its surface and operating with no bias voltage. Here, the response characteristics of PVDF detectors with areas in the range 4-150 sq cm and thickness in the range 2-28 microns to iron particles accelerated to velocities in the range 1-12 km/s are reported. The discussion also covers the mechanism of detection, fast pulse response, noise characteristics, and the dependence of the detector signal amplitude on particle mass and velocity. The detectors exhibit long-term stability and can be operated for extended periods of time over the temperature range -50 to +50 C; their response to dust particle impacts is unaffected by high background fluxes of charged particles.

Simpson, J. A.↗