Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deformation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Autonomous extraction of millimeter-scale deformation in InSAR time series using deep learning

Systematically characterizing slip behaviours on active faults is key to unraveling the physics of tectonic faulting and the interplay between slow and fast earthquakes. Interferometric Synthetic Aperture Radar (InSAR), by enabling measurement of ground deformation at a global scale every few days, may hold the key to those interactions. However, atmospheric propagation delays often exceed ground deformation of interest despite state-of-the art processing, and thus InSAR analysis requires expert interpretation and a priori knowledge of fault systems, precluding global investigations of deformation dynamics. Here, we show that a deep auto-encoder architecture tailored to untangle ground deformation from noise in InSAR time series autonomously extracts deformation signals, without prior knowledge of a fault’s location or slip behaviour. Applied to InSAR data over the North Anatolian Fault, our method reaches 2 mm detection, revealing a slow earthquake twice as extensive as previously recognized. We further explore the generalization of our approach to inflation/deflation-induced deformation, applying the same methodology to the geothermal field of Coso, California.

58 GEOSCIENCES↗

Alloying effects on deformation induced microstructure evolution in copper

In this work, we investigated the effects of alloying elements on plastic deformation and microstructure evolution in polycrystalline copper (Cu) and Cu alloyed with 1 wt. % lead (Cu-1 %Pb). These materials were selected due to the size mismatch between Cu and Pb, with the latter forming precipitates at grain boundaries. Multi-modal characterization techniques, including neutron diffraction, electron backscatter diffraction (EBSD), and transmission electron microscopy (TEM), along with finite element simulations were employed to study the deformation behavior across multiple length scales. While both Cu and Cu-1%Pb exhibited similar macroscale response and final deformation textures, both dislocation line profile analysis and TEM revealed increased dislocation density in deformed Cu-1%Pb specimens. The presence of lead precipitates also significantly affected local plastic deformation during compression, with their influence diminishing with increasing strain. These results demonstrate the complex relationships between alloying elements, plastic deformation, microstructural evolution, and material behavior under load. The insights gained from this multi-scale and multi-technique approach contribute to the fundamental understanding of microstructural evolution in immiscible alloys and are valuable for tailoring the properties of structural materials for specific engineering applications.

36 MATERIALS SCIENCE↗

NON-CONTACT ACOUSTO-THERMAL SIGNATURES OF PLASTIC DEFORMATION IN TI-6AL-4V

Plastic deformation introduces changes in a material which include increases in: dislocations, strains, residual stress, and yield stress. However, these changes have a very small impact on the material properties such as elastic modulus, conductivity and ultrasonic wave speed. This is due to the fact that interatomic forces govern these properties, and they are not affected by plastic deformation to any large degree. This is evident from the fact that the changes in electrical resistance and ultrasonic velocity in plastically deformed and virgin samples are very small and can only be determined by highly controlled experiments. Except for X-ray diffraction, there are no direct nondestructive methods for measuring strain and the residual stress. This paper presents an application of the non-contact acousto-thermal signature (NCATS) NDE methodology to detect plastic deformation in flat dog bone Ti-6Al-4V samples. Results of the NCATS measurements on samples subjected to incremental amounts of plastic deformation are presented. The maximum temperature attained by the sample due to acoustic excitation is found to be sensitive to the amount of plastic strain. It is observed that the temperature induced by acoustic excitation increases to a peak followed by a decrease to failure. The maximum temperature peak occurs at plastic strains of 12-14%. It is observed that there is a correlation between the peak in maximum temperature rise and the strain at the experimentally determined ultimate tensile strength. A microstructural based explanation for this will be presented. The results are discussed in reference to utilizing this technique for detection and evaluation of plastic deformation.

36 MATERIALS SCIENCE↗

Pressure–strain interaction. I. On compression, deformation, and implications for Pi-D

The pressure–strain interaction describes the rate per unit volume that energy is converted between bulk flow and thermal energy in neutral fluids or plasmas. The term has been written as a sum of the pressure dilatation and the collisionless analog of viscous heating referred to as Pi–D , which isolates the power density due to compressible and incompressible effects, respectively. It has been shown that Pi–D can be negative, which makes its identification as collisionless viscous heating troubling. We argue that an alternate decomposition of pressure–strain interaction can be useful for interpreting the underlying physics. Since Pi–D contains both normal deformation and shear deformation, we propose grouping the normal deformation with the pressure dilatation to describe the power density due to converging/diverging flows, with the balance describing the power density purely due to shear deformation. We then develop a kinetic theory interpretation of compression, normal deformation, and shear deformation. We use the results to determine the physical mechanisms that can make Pi–D negative. We argue that both decompositions can be useful for the study of energy conversion in weakly collisional or collisionless fluids and plasmas, and implications are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Duality defect in a deformed transverse-field Ising model

Physical quantities with long lifetimes have both theoretical significance in the study of quantum many-body systems and practical implications for quantum technologies. In this manuscript, we investigate the roles played by topological defects in the construction of quasiconserved quantities, using as a prototypical example the Kramers-Wannier duality defect in a deformed one-dimensional quantum transverse-field Ising model. We construct the duality defect Hamiltonian in three different ways: half-chain Kramers-Wannier transformation, utilization of techniques in the Ising fusion category, and defect-modified weak integrability breaking deformation. The third method is also applicable for the study of generic integrable defects under weak integrability breaking deformations. We also work out the deformation of defect-modified higher charges in the model and study their slower decay behavior. Furthermore, we consider the corresponding duality defect twisted deformed Floquet transverse-field Ising model and investigate the stability of the isolated zero mode associated with the duality defect in the integrable Floquet Ising model, under such weak integrability breaking deformation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of quadrupole deformation and continuum effects in the “island of inversion” nuclei 28,29,31 F

The peculiar properties of nuclei in the so-called “island of inversion” around Z = 10 and N = 20 are the focus of current nuclear physics research. Recent studies showed that 28 F has a negative-parity ground state and thus lies within the southern shore of the island of inversion, and 29 F presents a halo structure in its ground state, but it is unclear which effects, such as deformation, shell evolution due to tensor forces, or couplings to the continuum, lead to this situation. Here, we investigate the role of quadrupole deformation and continuum effects on the single-particle structure of 28,29,31 F from a relativistic mean-field approach and show how both phenomena can lead to a negative-parity ground state in 28 F and halo structures in 29,31 F. We solve the Dirac equation in the complex-momentum (Berggren) representation for a potential with quadrupole deformation at the first order obtained from relativistic mean-field calculations using the NL3 interaction and calculate the continuum level densities using the Green’s function method. We extract single-particle energies and widths from the continuum level densities to construct the Nilsson diagrams of 28,29,31 F in the continuum and analyze the evolution of both the widths and occupation probabilities of relevant Nilsson orbitals in 28 F and find that some amount of prolate deformation must be present. In addition, we calculate the density distributions for bound Nilsson orbitals near the Fermi surface in 29,31 F and reveal that, for a quadrupole deformation 0.3 ≤ β 2 ≤ 0.45 (prolate), characteristic halo tails appear at large distances. Using the relativistic mean-field approach in the complex-momentum representation with the Green’s function method, we demonstrate that in neutron-rich fluorine isotopes, while in the spherical case the pf shells are already inverted and close to the neutron emission threshold, a small amount of quadrupole deformation can dramatically reduce the gap between positive- and negative-parity states and increase the role of continuum states, ultimately leading to the negative parity in the ground state of 28 F and the halo structures in 29,31 F.

20 ≤ A ≤ 38↗

Tidal deformability with sharp phase transitions in binary neutron stars

The neutron star tidal deformability is a critical parameter which determines the premerger gravitational-wave signal in a neutron star merger. In this article, we show how neutron star tidal deformabilities behave in the presence of one or two sharp phase transition(s). We characterize how the tidal deformability changes when the properties of these phase transitions are modified in dense matter equations of state. Sharp phase transitions lead to the smallest possible tidal deformabilities and also induce discontinuities in the relation between tidal deformability and gravitational mass. These results are qualitatively unmodified by a modest softening of the phase transition. Lastly, we test two universal relations involving the tidal deformability and show that their accuracy is limited by sharp phase transitions.

79 ASTRONOMY AND ASTROPHYSICS↗

Coulomb excitation of 80 Sr and the limits of the 𝑁 ≈ 𝑍 ≈ 40 island of deformation

The region of 𝑁 ≈ 𝑍 ≈ 40 has long been associated with strongly deformed nuclear configurations. The presence of this strong deformation was recently confirmed through lifetime measurements in 𝑁 ≈ 𝑍 Sr and Zr nuclei. Theoretically, however, these nuclei present a challenge due to the vast valence space required to incorporate all necessary orbitals. Recent state-of-the-art predictions indicate a near axial prolate deformation for 𝑁 = 𝑍 and 𝑁 = 𝑍+2 nuclei between 𝑁 = 𝑍 = 36 and 𝑁 = 𝑍 = 40. In this work we investigate the shores of this island of deformation through a sub-barrier Coulomb excitation study of the 𝑁 = 𝑍+4 nucleus, 80 Sr . Extracting a spectroscopic quadrupole moment of 𝑄 𝑠 ⁡($2^+_1$)= $0.5^{+0.8}_{−0.9}$𝑒⁢b, we find that 80 Sr is inconsistent with significant axial prolate deformation with a significance of 1.5⁢𝜎. This result, albeit with a large uncertainty, indicates that the predicted region of strong prolate deformation around 𝑁 = 𝑍 = 40 is tightly constrained to the quartet of nuclei: 76,78 Sr and 78,80 Zr .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-BRF-03: Quality Assurance of Deformable Image Registration in Radiotherapy

Purpose: To introduce methods to analyze Deformable Image Registration (DIR) and identify regions of potential DIR errors. Methods: DIR Deformable Vector Fields (DVFs) quantifying patient anatomic changes were evaluated using the Jacobian determinant and the magnitude of DVF curl as functions of tissue density and tissue type. These quantities represent local relative deformation and rotation, respectively. Large values in dense tissues can potentially identify non-physical DVF errors. For multiple DVFs per patient, histograms and visualization of DVF differences were also considered. To demonstrate the capabilities of methods, we computed multiple DVFs for each of five Head and Neck (H'N) patients (P1–P5) via a Fast-symmetric Demons (FSD) algorithm and via a Diffeomorphic Demons (DFD) algorithm, and show the potential to identify DVF errors. Results: Quantitative comparisons of the FSD and DFD registrations revealed <0.3 cm DVF differences in >99% of all voxels for P1, >96% for P2, and >90% of voxels for P3. While the FSD and DFD registrations were very similar for these patients, the Jacobian determinant was >50% in 9–15% of soft tissue and in 3–17% of bony tissue in each of these cases. The volumes of large soft tissue deformation were consistent for all five patients using the FSD algorithm (mean 15%±4% volume), whereas DFD reduced regions of large deformation by 10% volume (785 cm{sup 3}) for P4 and by 14% volume (1775 cm{sup 3}) for P5. The DFD registrations resulted in fewer regions of large DVF-curl; 50% rotations in FSD registrations averaged 209±136 cm{sup 3} in soft tissue and 10±11 cm{sup 3} in bony tissue, but using DFD these values were reduced to 42±53 cm{sup 3} and 1.1±1.5 cm{sup 3}, respectively. Conclusion: Analysis of Jacobian determinant and curl as functions of tissue density can identify regions of potential DVF errors by identifying non-physical deformations and rotations. Collaboration with Phillips Healthcare, as indicated in authorship.

60 APPLIED LIFE SCIENCES↗

SU-F-BRF-14: Increasing the Accuracy of Dose Calculation On Cone-Beam Imaging Using Deformable Image Registration in the Case of Prostate Translation

Purpose: Artifacts can reduce the quality of dose re-calculations on CBCT scans during a treatment. The aim of this project is to correct the CBCT images in order to allow for more accurate and exact dose calculations in the case of a translation of the tumor in prostate cancer. Methods: Our approach is to develop strategies based on deformable image registration algorithms using the elastix software (Klein et al., 2010) to register the treatment planning CT on a daily CBCT scan taken during treatment. Sets of images are provided by a 3D deformable phantom and comprise two CT and two CBCT scans: one of both with the reference anatomy and the others with known deformations (i.e. translations of the prostate). The reference CT is registered onto the deformed CBCT and the deformed CT serves as the control for dose calculation accuracy. The planned treatment used for the evaluation of dose calculation is a 2-Gy fraction prescribed at the location of the reference prostate and assigned to 7 rectangular fields. Results: For a realistic 0.5-cm translation of the prostate, the relative dose discrepancy between the CBCT and the CT control scan at the prostate's centroid is 8.9 ± 0.8 % while dose discrepancy between the registered CT and the control scan lessens to −2.4 ± 0.8 %. For a 2-cm translation, clinical indices like the V90 and the D100 are more accurate by 0.7 ± 0.3 % and 8.0 ± 0.5 cGy respectively when using registered CT than when using CBCT for dose calculation. Conclusion: The results show that this strategy gives doses in agreement within a few percents with those from calculations on actual CT scans. In the future, various deformations of the phantom anatomy will allow a thorough characterization of the registration strategies needed for more complex anatomies.

60 APPLIED LIFE SCIENCES↗

WE-D-9A-02: Automated Landmark-Guided CT to Cone-Beam CT Deformable Image Registration

Purpose: The anatomical changes that occur between the simulation CT and daily cone-beam CT (CBCT) are investigated using an automated landmark-guided deformable image registration (LDIR) algorithm with simultaneous intensity correction. LDIR was designed to be accurate in the presence of tissue intensity mismatch and heavy noise contamination. Method: An auto-landmark generation algorithm was used in conjunction with a local small volume (LSV) gradient matching search engine to map corresponding landmarks between the CBCT and planning CT. The LSVs offsets were used to perform an initial deformation, generate landmarks, and correct local intensity mismatch. The landmarks act as stabilizing controlpoints in the Demons objective function. The accuracy of the LDIR algorithm was evaluated on one synthetic case with ground truth and data of ten head and neck cancer patients. The deformation vector field (DVF) accuracy was accessed using a synthetic case. The Root mean square error of the 3D canny edge (RMSECE), mutual information (MI), and feature similarity index metric (FSIM) were used to access the accuracy of LDIR on the patient data. The quality of the corresponding deformed contours was verified by an attending physician. Results: The resulting 90 percentile DVF error for the synthetic case was within 5.63mm for the original demons algorithm, 2.84mm for intensity correction alone, 2.45mm using controlpoints without intensity correction, and 1.48 mm for the LDIR algorithm. For the five patients the mean RMSECE of the original CT, Demons deformed CT, intensity corrected Demons CT, control-point stabilized deformed CT, and LDIR CT was 0.24, 0.26, 0.20, 0.20, and 0.16 respectively. Conclusion: LDIR is accurate in the presence of multimodal intensity mismatch and CBCT noise contamination. Since LDIR is GPU based it can be implemented with minimal additional strain on clinical resources. This project has been supported by a CPRIT individual investigator award RP11032.

60 APPLIED LIFE SCIENCES↗

The ANACONDA algorithm for deformable image registration in radiotherapy

Purpose: The purpose of this work was to describe a versatile algorithm for deformable image registration with applications in radiotherapy and to validate it on thoracic 4DCT data as well as CT/cone beam CT (CBCT) data. Methods: ANAtomically CONstrained Deformation Algorithm (ANACONDA) combines image information (i.e., intensities) with anatomical information as provided by contoured image sets. The registration problem is formulated as a nonlinear optimization problem and solved with an in-house developed solver, tailored to this problem. The objective function, which is minimized during optimization, is a linear combination of four nonlinear terms: 1. image similarity term; 2. grid regularization term, which aims at keeping the deformed image grid smooth and invertible; 3. a shape based regularization term which works to keep the deformation anatomically reasonable when regions of interest are present in the reference image; and 4. a penalty term which is added to the optimization problem when controlling structures are used, aimed at deforming the selected structure in the reference image to the corresponding structure in the target image. Results: To validate ANACONDA, the authors have used 16 publically available thoracic 4DCT data sets for which target registration errors from several algorithms have been reported in the literature. On average for the 16 data sets, the target registration error is 1.17 ± 0.87 mm, Dice similarity coefficient is 0.98 for the two lungs, and image similarity, measured by the correlation coefficient, is 0.95. The authors have also validated ANACONDA using two pelvic cases and one head and neck case with planning CT and daily acquired CBCT. Each image has been contoured by a physician (radiation oncologist) or experienced radiation therapist. The results are an improvement with respect to rigid registration. However, for the head and neck case, the sample set is too small to show statistical significance. Conclusions: ANACONDA performs well in comparison with other algorithms. By including CT/CBCT data in the validation, the various aspects of the algorithm such as its ability to handle different modalities, large deformations, and air pockets are shown.

60 APPLIED LIFE SCIENCES↗

SU-E-J-115: Correlation of Displacement Vector Fields Calculated by Deformable Image Registration Algorithms with Motion Parameters of CT Images with Well-Defined Targets and Controlled-Motion

Purpose: To investigate correlation of displacement vector fields (DVF) calculated by deformable image registration algorithms with motion parameters in helical axial and cone-beam CT images with motion artifacts. Methods: A mobile thorax phantom with well-known targets with different sizes that were made from water-equivalent material and inserted in foam to simulate lung lesions. The thorax phantom was imaged with helical, axial and cone-beam CT. The phantom was moved with a cyclic motion with different motion amplitudes and frequencies along the superior-inferior direction. Different deformable image registration algorithms including demons, fast demons, Horn-Shunck and iterative-optical-flow from the DIRART software were used to deform CT images for the phantom with different motion patterns. The CT images of the mobile phantom were deformed to CT images of the stationary phantom. Results: The values of displacement vectors calculated by deformable image registration algorithm correlated strongly with motion amplitude where large displacement vectors were calculated for CT images with large motion amplitudes. For example, the maximal displacement vectors were nearly equal to the motion amplitudes (5mm, 10mm or 20mm) at interfaces between the mobile targets lung tissue, while the minimal displacement vectors were nearly equal to negative the motion amplitudes. The maximal and minimal displacement vectors matched with edges of the blurred targets along the Z-axis (motion-direction), while DVF’s were small in the other directions. This indicates that the blurred edges by phantom motion were shifted largely to match with the actual target edge. These shifts were nearly equal to the motion amplitude. Conclusions: The DVF from deformable-image registration algorithms correlated well with motion amplitude of well-defined mobile targets. This can be used to extract motion parameters such as amplitude. However, as motion amplitudes increased, image artifacts increased significantly and that limited image quality and poor correlation between the motion amplitude and DVF was obtained.

60 APPLIED LIFE SCIENCES↗

Simulation of pseudo-CT images based on deformable image registration of ultrasound images: A proof of concept for transabdominal ultrasound imaging of the prostate during radiotherapy

Purpose: Imaging of patient anatomy during treatment is a necessity for position verification and for adaptive radiotherapy based on daily dose recalculation. Ultrasound (US) image guided radiotherapy systems are currently available to collect US images at the simulation stage (US{sub sim}), coregistered with the simulation computed tomography (CT), and during all treatment fractions. The authors hypothesize that a deformation field derived from US-based deformable image registration can be used to create a daily pseudo-CT (CT{sub ps}) image that is more representative of the patients’ geometry during treatment than the CT acquired at simulation stage (CT{sub sim}). Methods: The three prostate patients, considered to evaluate this hypothesis, had coregistered CT and US scans on various days. In particular, two patients had two US–CT datasets each and the third one had five US–CT datasets. Deformation fields were computed between pairs of US images of the same patient and then applied to the corresponding US{sub sim} scan to yield a new deformed CT{sub ps} scan. The original treatment plans were used to recalculate dose distributions in the simulation, deformed and ground truth CT (CT{sub gt}) images to compare dice similarity coefficients, maximum absolute distance, and mean absolute distance on CT delineations and gamma index (γ) evaluations on both the Hounsfield units (HUs) and the dose. Results: In the majority, deformation did improve the results for all three evaluation methods. The change in gamma failure for dose (γ{sub Dose}, 3%, 3 mm) ranged from an improvement of 11.2% in the prostate volume to a deterioration of 1.3% in the prostate and bladder. The change in gamma failure for the CT images (γ{sub CT}, 50 HU, 3 mm) ranged from an improvement of 20.5% in the anus and rectum to a deterioration of 3.2% in the prostate. Conclusions: This new technique may generate CT{sub ps} images that are more representative of the actual patient anatomy than the CT{sub sim} scan.

60 APPLIED LIFE SCIENCES↗

SU-F-J-97: A Joint Registration and Segmentation Approach for Large Bladder Deformations in Adaptive Radiotherapy

Purpose: To improve results of deformable image registration (DIR) in adaptive radiotherapy for large bladder deformations in CT/CBCT pelvis imaging. Methods: A variational multi-modal DIR algorithm is incorporated in a joint iterative scheme, alternating between segmentation based bladder matching and registration. Using an initial DIR to propagate the bladder contour to the CBCT, in a segmentation step the contour is improved by discrete image gradient sampling along all surface normals and adapting the delineation to match the location of each maximum (with a search range of +−5/2mm at the superior/inferior bladder side and step size of 0.5mm). An additional graph-cut based constraint limits the maximum difference between neighboring points. This improved contour is utilized in a subsequent DIR with a surface matching constraint. By calculating an euclidean distance map of the improved contour surface, the new constraint enforces the DIR to map each point of the original contour onto the improved contour. The resulting deformation is then used as a starting guess to compute a deformation update, which can again be used for the next segmentation step. The result is a dense deformation, able to capture much larger bladder deformations. The new method is evaluated on ten CT/CBCT male pelvis datasets, calculating Dice similarity coefficients (DSC) between the final propagated bladder contour and a manually delineated gold standard on the CBCT image. Results: Over all ten cases, an average DSC of 0.93±0.03 is achieved on the bladder. Compared with the initial DIR (0.88±0.05), the DSC is equal (2 cases) or improved (8 cases). Additionally, DSC accuracy of femoral bones (0.94±0.02) was not affected. Conclusion: The new approach shows that using the presented alternating segmentation/registration approach, the results of bladder DIR in the pelvis region can be greatly improved, especially for cases with large variations in bladder volume. Fraunhofer MEVIS received funding from a research grant by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

In situ neutron diffraction study on tensile deformation behavior of carbon-strengthened CoCrFeMnNi high-entropy alloys at room and elevated temperatures

In this paper, carbon is doped into a CoCrFeMnNi high-entropy alloy as an interstitial atom, improving the single phase solid solution alloy with a good combination of strength and ductility at room temperature by introducing deformation twins. In situ neutron diffraction (ND) is applied to investigate the carbon-doped CoCrFeMnNi deformation mechanism and micromechanical behaviors during uniaxial tension at room and elevated temperatures. With in situ results accompanied with the microstructure and texture measurement, it is found that the plastic deformation is dominated by dislocation slip at an early stage at both temperatures. However, at high strain level, deformation is mediated simultaneously by deformation twins and microbands at room temperature, while it is governed solely by microbands at elevated temperature of 573 K. The evolution of lattice strain, peak intensity, and peak width from in situ ND elucidates the micromechanical behaviors regarding the role of slips and twins. Finally, the texture represented by orientation distribution function indicates that the initial specimen possesses a relatively strong {112} <110> texture component, and the room-temperature tension deformed texture comprises of slip-induced fiber texture and twinning-induced {115} <552> texture component.

36 MATERIALS SCIENCE↗

Multiscale framework for predicting the coupling between deformation and fluid diffusion in porous rocks

In this project, a predictive multiscale framework will be developed to simulate the strong coupling between solid deformations and fluid diffusion in porous rocks. We intend to improve macroscale modeling by incorporating fundamental physical modeling at the microscale in a computationally efficient way. This is an essential step toward further developments in multiphysics modeling, linking hydraulic, thermal, chemical, and geomechanical processes. This research will focus on areas where severe deformations are observed, such as deformation bands, where classical phenomenology breaks down. Multiscale geometric complexities and key geomechanical and hydraulic attributes of deformation bands (e.g., grain sliding and crushing, and pore collapse, causing interstitial fluid expulsion under saturated conditions), can significantly affect the constitutive response of the skeleton and the intrinsic permeability. Discrete mechanics (DEM) and the lattice Boltzmann method (LBM) will be used to probe the microstructure---under the current state---to extract the evolution of macroscopic constitutive parameters and the permeability tensor. These evolving macroscopic constitutive parameters are then directly used in continuum scale predictions using the finite element method (FEM) accounting for the coupled solid deformation and fluid diffusion. A particularly valuable aspect of this research is the thorough quantitative verification and validation program at different scales. The multiscale homogenization framework will be validated using X-ray computed tomography and 3D digital image correlation in situ at the Advanced Photon Source in Argonne National Laboratories. Also, the hierarchical computations at the specimen level will be validated using the aforementioned techniques in samples of sandstone undergoing deformation bands.

58 GEOSCIENCES↗

Residual Stresses and Plastic Deformation in Self-Pierce Riveting of Dissimilar Aluminum-to-Magnesium Alloys

In this study, the complex relationship between deformation history and residual stresses in a magnesium-to-aluminum self-pierce riveted (SPR) joint is elucidated using numerical and experimental approaches. Non-linear finite element (FE) simulations incorporating strain rate and temperature effects were performed to model the deformation in the SPR process. In order to accurately capture the deformation, a stress triaxiality-based damage material model was employed to capture the sheet piercing from the rivet. Strong visual comparison between the physical cross-section of the SPR joint and the simulation was achieved. To aid in understanding of the role of deformation in the riveting process and to validate the modeling approach, several experimental measurements were conducted. To quantify the plastic deformation from the piercing of the rivet, micro hardness mapping was performed on a cross-section of the SPR joint. The FE model showed very strong correlation to the experimental hardness mapping results suggesting the nonlinear model captured the plastic deformation with high accuracy. To measure the elastic residual stresses in the SPR joint, neutron and x-ray diffraction mapping techniques were conducted and in general, the FE model correlated well to the trends and magnitudes of the elastic stresses. While some error occurred in between the model and the neutron and x-ray diffraction results, the numerical approach developed in this study shows potential as a tool for understanding SPR behavior as well as optimizing the process parameters.

36 MATERIALS SCIENCE↗