Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Resolution enhancement of multichannel microwave imagery from the Nimbus-7 SMMR for maritime rainfall analysis

A restoration of the 37, 21, 18, 10.7, and 6.6 GHz satellite imagery from the scanning multichannel microwave radiometer (SMMR) aboard Nimbus-7 to 22.2 km resolution is attempted using a deconvolution method based upon nonlinear programming. The images are deconvolved with and without the aid of prescribed constraints, which force the processed image to abide by partial a priori knowledge of the high-resolution result. The restored microwave imagery may be utilized to examined the distribution of precipitating liquid water in marine rain systems.

Olson, W. S.↗

Study of non-thermal photon production under different scenarios in solar flares. 2: The Compton inverse and Bremsstrahlung models and fittings

Energy spectra of photons emitted from Bremsstrahlung (BR) of energetic electrons with matter, is obtained from the deconvolution of the electron energy spectra. It can be inferred that the scenario for the production of X-rays and gamma rays in solar flares may vary from event to event. However, it is possible in many cases to associated low energy events to impulsive acceleration, and the high energy phase of some events to stochastic acceleration. In both cases, flare particles seem to be strongly modulated by local energy losses. Electric field acceleration, associated to neutral current sheets is a suitable candidate for impulsive acceleration. Finally, that the predominant radiation process of this radiation is the inverse Compton effect due to the local flare photon field.

Perez-Peraza, J.↗

A simple method of obtaining concentration depth-profiles from X-ray diffraction

The construction of composition profiles from X-ray intensity bands was investigated. The intensity band-to-composition profile transformation utilizes a solution which can be easily evaluated. The technique can be applied to thin films and thick speciments for which the variation of lattice parameters, linear absorption coefficient, and reflectivity with composition are known. A deconvolution scheme with corrections for the instrumental broadening and ak-alfadoublet is discussed.

Wiedemann, K. E.↗

A Study of Morrison's Iterative Noise Removal Method

Morrison's iterative noise removal method is studied by characterizing its effect upon systems of differing noise level and response function. The nature of data acquired from a linear shift invariant instrument is discussed so as to define the relationship between the input signal, the instrument response function, and the output signal. Fourier analysis is introduced, along with several pertinent theorems, as a tool to more thorough understanding of the nature of and difficulties with deconvolution. In relation to such difficulties the necessity of a noise removal process is discussed. Morrison's iterative noise removal method and the restrictions upon its application are developed. The nature of permissible response functions is discussed, as is the choice of the response functions used.

Ioup, G. E.↗

Input-output characterization of an ultrasonic testing system by digital signal analysis

Ultrasonic test system input-output characteristics were investigated by directly coupling the transmitting and receiving transducers face to face without a test specimen. Some of the fundamentals of digital signal processing were summarized. Input and output signals were digitized by using a digital oscilloscope, and the digitized data were processed in a microcomputer by using digital signal-processing techniques. The continuous-time test system was modeled as a discrete-time, linear, shift-invariant system. In estimating the unit-sample response and frequency response of the discrete-time system, it was necessary to use digital filtering to remove low-amplitude noise, which interfered with deconvolution calculations. A digital bandpass filter constructed with the assistance of a Blackman window and a rectangular time window were used. Approximations of the impulse response and the frequency response of the continuous-time test system were obtained by linearly interpolating the defining points of the unit-sample response and the frequency response of the discrete-time system. The test system behaved as a linear-phase bandpass filter in the frequency range 0.6 to 2.3 MHz. These frequencies were selected in accordance with the criterion that they were 6 dB below the maximum peak of the amplitude of the frequency response. The output of the system to various inputs was predicted and the results were compared with the corresponding measurements on the system.

Williams, J. H., Jr.↗

Quantitative analysis of hard X-ray 'footpoint' flares observed by the solar maximum mission

Amplifier gain and collimator hole size variations across the field of view, amplifier/filter efficiency, variations in effective collimator hole size and angular response with photon energy, dead-time, and hard X-ray plate transmission, are among the factors for which instrumental corrections have to be incorporated to effect reliable correction and deconvolution of images from the SMM satellite's Hard X-ray Imaging Spectrometer (HXIS). Attention is given to the substantial Poisson noise in these energy bands. The maximum entropy deconvolution/correction routine developed for establishing the spatial structure reliably inferrable from HXIS data is presented, together with the results of the application of this routine to the three impulsive flares reported by Duijemian et al. (1982) from April 10, May 21, and November 5, 1980.

Mackinnon, A. L.↗

The spatial structure of IRC + 10216 and NGC 7027 in the far-infrared

Spatial scans of IRC + 10216 and NGC 7027 were made at 50 and 100 microns using a diffraction-limited slit. Maximum entropy deconvolution techniques were applied to the data and, in effect, the structure of these sources was probed down to a scale far smaller than previously achieved at these wavelengths. IRC + 10216 was unresolved on a spatial scale of several arcsecs and a low upper limit to either the dust-gas ratio or the bulk emissivity of the grains was implied for the large molecular envelope surrounding the star. NGC 7027 was easily resolved in the scans, with far-infrared emission distribution corresponding closely with the distribution of ionized gas and shorter wavelength infrared emission.

Lester, D. F.↗

Separating Peaks in X-Ray Spectra

Deconvolution algorithm assists in analysis of x-ray spectra from scanning electron microscopes, electron microprobe analyzers, x-ray fluorescence spectrometers, and like. New algorithm automatically deconvolves x-ray spectrum, identifies locations of spectral peaks, and selects chemical elements most likely producing peaks. Technique based on similarities between zero- and second-order terms of Taylor-series expansions of Gaussian distribution and of damped sinusoid. Principal advantage of algorithm: no requirement to adjust weighting factors or other parameters when analyzing general x-ray spectra.

Nicolas, David↗

Resolution enhancement of multichannel microwave imagery from the Nimbus-7 SMMR for maritime rainfall analysis

A restoration of the 37, 21, 18, 10.7, and 6.6 GHz satellite imagery from the scanning multichannel microwave radiometer (SMMR) aboard Nimbus-7 to 22.2 km resolution is attempted using a deconvolution method based upon nonlinear programming. The images are deconvolved with and without the aid of prescribed constraints, which force the processed image to abide by partial a priori knowledge of the high-resolution result. The restored microwave imagery may be utilized to examine the distribution of precipitating liquid water in marine rain systems.

Olson, William S.↗

Measurements of electron attachment lineshapes and cross sections at ultra-low electron energies for CF2Cl2, c-C4F6, c-C4F8 and c-C7F14

Electron-attachment cross sections are reported in the electron energy range 0-160 meV, and at energy resolutions of 7.0 and 7.5 meV (FWHM), for the molecules CF2Cl2 (dichlorodifluoromethane), c-C4F6 (perfluorocyclobutene), c-C4F8 (perfluorocyclobutane), and c-C7F14 (perfluoromethylcyclohexane). Use is made of the Kr photoionization method. Measured attachment lineshapes are deconvoluted from the spectral slit function, and are converted to cross sections by normalization through thermal attachment-rate constants. Comparisons are made with attachment cross sections derived from several independent sets of swarm-measured rate constants, and with collisional ionization (high-Rydberg attachment) data.

Chutjian, A.↗

Far-infrared detection of a circumstellar dust torus around Sharpless 106

High angular resolution scans at 42 and 95 microns have been obtained of the far-infrared source associated with S106. Using maximum entropy deconvolution techniques it is found that the far-IR-emitting dust appears to be distributed in a toroidal shape around the central star.This result is similar to the morphology implied to millimeter line and continuum mapping on a variety of size scales.

Harvey, Paul M.↗

Optical correlator use at Johnson Space Center

For automation and robotics in the Space Station era, NASA's Johnson Space Center is pursuing several means of synthetic vision. The optical correlator is one such means. The deformable mirror device will form the basis of the first correlator in this project. In-house and contracted effort is being used. Initial in-house activities will concentrate on an impulse deconvolution technique and on a programmable retina for spatial remappings of an image prior to correlation. The retina will permit a form of edge extraction and other primitive operations. Additionally, it will be used as a research tool for assisting persons with low vision.

Juday, Richard D.↗

The quality of geological information derivable from high resolution reflectance spectra - Results for mafic silicates

High-resolution visible and near-infrared diffuse reflectance spectra of mafic silicates can be deconvolved to yield quantitative information concerning mineral mixture properties, and the results can be directly applied to remotely sensed data. Spectral reflectance measurements of laboratory mixtures of olivine, orthophyroxene, and clinopyroxene with known chemistries, phase abundances, and particle size distributions have been utilized to develop correlations between spectral properties and the physicochemical parameters of the samples. A large number of mafic silicate spectra were measured and examined for systematic variations in spectral properties as a function of chemistry, phase abundance, and particle size. Three classes of spectral parameters (ratioed, absolute, and wavelength) were examined for any correlations. Each class is sensitive to particular mafic silicate properties. Spectral deconvolution techniques have been developed for quantifying, with varying degrees of accuracy, the assemblage properties (chemistry, phase abundance, and particle size).

Cloutis, E. A.↗

Data reduction and analysis of HELIOS plasma wave data

Reduction of data acquired from the HELIOS Solar Wind Plasma Wave Experiments on HELIOS 1 and 2 was continued. Production of 24 hour survey plots of the HELIOS 1 plasma wave data were continued and microfilm copies were submitted to the National Space Science Data Center. Much of the effort involved the shock memory from both HELIOS 1 and 2. This data had to be deconvoluted and time ordered before it could be displayed and plotted in an organized form. The UNIVAX 418-III computer was replaced by a DEC VAX 11/780 computer. In order to continue the reduction and analysis of the data set, all data reduction and analysis computer programs had to be rewritten.

Anderson, Roger R.↗

Techniques for the analysis of data from coded-mask X-ray telescopes

Several techniques useful in the analysis of data from coded-mask telescopes are presented. Methods of handling changes in the instrument pointing direction are reviewed and ways of using FFT techniques to do the deconvolution considered. Emphasis is on techniques for optimally-coded systems, but it is shown that the range of systems included in this class can be extended through the new concept of 'partial cycle averaging'.

Skinner, G. K.↗

Narrow band imagery in the 8-14 micron spectral region

The problem of deconvolution of the point source response function (PSF) for two-dimensional imaging infrared arrays is addressed. A variety of phenomena can lead to PSF degradation, ranging from atmospheric turbulence to the array itself. The maximum entropy algorithm is used to demonstrate that substantial image quality improvements are possible in the case of a PSF which is degraded by electronic rather than optical smearing. This result implies that IR arrays need not have perfect or even very good pixel-pixel crosstalk rejection ratios for use in astronomy.

Goebel, J. H.↗