Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

S-SAD phasing study of death receptor 6 and its solution conformation revealed by SAXS

A comparative analysis of sulfur phasing of death receptor 6 (DR6) using data collected at wavelengths of 2.0 and 2.7 Å is presented. SAXS analysis of unliganded DR6 defines a dimer as the minimum physical unit in solution. A subset of tumour necrosis factor receptor (TNFR) superfamily members contain death domains in their cytoplasmic tails. Death receptor 6 (DR6) is one such member and can trigger apoptosis upon the binding of a ligand by its cysteine-rich domains (CRDs). The crystal structure of the ectodomain (amino acids 1–348) of human death receptor 6 (DR6) encompassing the CRD region was phased using the anomalous signal from S atoms. In order to explore the feasibility of S-SAD phasing at longer wavelengths (beyond 2.5 Å), a comparative study was performed on data collected at wavelengths of 2.0 and 2.7 Å. In spite of sub-optimal experimental conditions, the 2.7 Å wavelength used for data collection showed potential for S-SAD phasing. The results showed that the R{sub ano}/R{sub p.i.m.} ratio is a good indicator for monitoring the anomalous data quality when the anomalous signal is relatively strong, while d′′/sig(d′′) calculated by SHELXC is a more sensitive and stable indicator applicable for grading a wider range of anomalous data qualities. The use of the ‘parameter-space screening method’ for S-SAD phasing resulted in solutions for data sets that failed during manual attempts. SAXS measurements on the ectodomain suggested that a dimer defines the minimal physical unit of an unliganded DR6 molecule in solution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Control and automation of the Pegasus multi-point Thomson scattering system

A new control system for the Pegasus Thomson scattering diagnostic has recently been deployed to automate the laser operation, data collection process, and interface with the system-wide Pegasus control code. Automation has been extended to areas outside of data collection, such as manipulation of beamline cameras and remotely controlled turning mirror actuators to enable intra-shot beam alignment. Additionally, the system has been upgraded with a set of fast (∼1 ms) mechanical shutters to mitigate contamination from background light. Modification and automation of the Thomson system have improved both data quality and diagnostic reliability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards Autonomous Experiments by Connecting High Performance Microscopy with High Performance Computing

The digitization of controls, data, and analysis in microscopy is bringing the idea of autonomous microscopes closer to reality than ever before. Automated transmission electron microscopy (TEM) is already fairly routine for some experiments the only require simple repetitive tasks such as imaging biological macromolecules for single particle cryoEM [1], tilt series for electron tomography [2], and movies for crystallography [3]. The vast majority of TEM experiments are conducted completely by human operators who choose the regions of interest, optimize experimental parameters, and make decisions about data quality visually during an experiment. The field is still a long way from having completely autonomous TEMs that can adapt to sample difficulties and tune experimental parameters based on data quality and desired experimental outcomes. Part of the issue is the lack of capability for feeding information learned from on-line, live data analysis back into the on-going experiment [4]. Furthermore, this presentation will discuss current capabilities for large scale data reduction and analysis using high performance computing (i.e. supercomputing) and progress towards developing a true feed-back loop that places data analysis and theory in the experimental loop.

97 MATHEMATICS AND COMPUTING↗

Developing the Proof of Concept for the SERI QC Flag Translation

SERI QC is a robust solar data quality assessment software tool that has been in continuous use for more than three decades. This report, the second of six in the Data Quality and Uncertainty Integration project, develops the proof of concept, including programming in C and a collection of spreadsheet tools, for estimating the operational uncertainty from three-component solar irradiance measurements using information available from SERI QC. The report establishes a field reference for determining the operational uncertainty for each irradiance component based on the SERI QC coupling. Results demonstrate that the operational uncertainty estimates based on global irradiance best represent the collective results for all sky conditions.

14 SOLAR ENERGY↗

Source scaling comparison and validation in Central Italy: data intensive direct S waves versus the sparse data coda envelope methodology

SUMMARY Robustness of source parameter estimates is a fundamental issue in understanding the relationships between small and large events; however, it is difficult to assess how much of the variability of the source parameters can be attributed to the physical source characteristics or to the uncertainties of the methods and data used to estimate the values. In this study, we apply the coda method by Mayeda et al. using the coda calibration tool (CCT), a freely available Java-based code (https://github.com/LLNL/coda-calibration-tool) to obtain a regional calibration for Central Italy for estimating stable source parameters. We demonstrate the power of the coda technique in this region and show that it provides the same robustness in source parameter estimation as a data-driven methodology [generalized inversion technique (GIT)], but with much fewer calibration events and stations. The Central Italy region is ideal for both GIT and coda approaches as it is characterized by high-quality data, including recent well-recorded seismic sequences such as L'Aquila (2009) and Amatrice–Norcia–Visso (2016–2017). This allows us to apply data-driven methods such as GIT and coda-based methods that require few, but high-quality data. The data set for GIT analysis includes ∼5000 earthquakes and more than 600 stations, while for coda analysis we used a small subset of 39 events spanning 3.5 < Mw < 6.33 and 14 well-distributed broad-band stations. For the common calibration events, as well as an additional 247 events (∼1.7 < Mw < ∼5.0) not used in either calibration, we find excellent agreement between GIT-derived and CCT-derived source spectra. This confirms the ability of the coda approach to obtain stable source parameters even with few calibration events and stations. Even reducing the coda calibration data set by 75 per cent, we found no appreciable degradation in performance. This validation of the coda calibration approach over a broad range of event size demonstrates that this procedure, once extended to other regions, represents a powerful tool for future routine applications to homogeneously evaluate robust source parameters on a national scale. Furthermore, the coda calibration procedure can homogenize the Mw estimates for small and large events without the necessity of introducing any conversion scale between narrow-band measures such as local magnitude (ML) and Mw, which has been shown to introduce significant bias.

Morasca, Paola (ORCID:0000000265254867)↗

Corrective Action Decision Document/Closure Report for Corrective Action Unit 546: Injection Well and Surface Releases Nevada Test Site, Nevada, Revision 0, with ROTCs 1-2

This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit 546, Injection Well and Surface Releases, at the Nevada Test Site, Nevada, in accordance with the Federal Facility Agreement and Consent Order (FFACO, 1996; as amended February 2008). Corrective Action Unit (CAU) 546 is comprised of two corrective action sites (CASs): • 06-23-02, U-6a/Russet Testing Area • 09-20-01, Injection Well The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation for closure of CAU 546. To achieve this, corrective action investigation (CAI) activities were performed from May 5 through May 28, 2008, as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 546: Injection Well and Surface Releases, Nevada Test Site, Nevada (NNSA/NSO, 2008). The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective (DQO) process: • Determine whether a contaminant of concern is present at a given CAS. • Determine whether sufficient information is available to evaluate potential corrective action alternatives at each CAS. The CAU 546 dataset from the investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the quality and acceptability of the dataset for use in fulfilling the DQO data needs. Because DQO data needs were met, and corrective actions have been implemented, it has been determined that no further corrective action (based on risk to human receptors) is necessary for the CAU 546 CASs. The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office provides the following recommendations: • No further corrective actions are needed for CAU 546 CASs. • No Corrective Action Plan is required. • A Notice of Completion to the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office is requested from the Nevada Division of Environmental Protection for closure of CAU 546. • Corrective Action Unit 546 should be moved from Appendix III to Appendix IV of the Federal Facility Agreement and Consent Order. Analytes detected during the CAI were evaluated against final action levels established in this document. No analytes were detected at concentrations exceeding final action levels. However, contaminants of concern were presumed to be present in the subsurface soil at CAS 09-20-01. Therefore, the corrective action of close in place was selected as the preferred alternative for this CAS. Potential source material was removed from CAS 06-23-02; therefore, the corrective action of clean closure was selected as the preferred alternative at this CAS.

54 ENVIRONMENTAL SCIENCES↗

Microfluidic sorting of protein nanocrystals by size for X-ray free-electron laser diffraction

The advent and application of the X-ray free-electron laser (XFEL) has uncovered the structures of proteins that could not previously be solved using traditional crystallography. While this new technology is powerful, optimization of the process is still needed to improve data quality and analysis efficiency. One area is sample heterogeneity, where variations in crystal size (among other factors) lead to the requirement of large data sets (and thus 10–100 mg of protein) for determining accurate structure factors. To decrease sample dispersity, we developed a high-throughput microfluidic sorter operating on the principle of dielectrophoresis, whereby polydisperse particles can be transported into various fluid streams for size fractionation. Using this microsorter, we isolated several milliliters of photosystem I nanocrystal fractions ranging from 200 to 600 nm in size as characterized by dynamic light scattering, nanoparticle tracking, and electron microscopy. Sorted nanocrystals were delivered in a liquid jet via the gas dynamic virtual nozzle into the path of the XFEL at the Linac Coherent Light Source. We obtained diffraction to ∼4 Å resolution, indicating that the small crystals were not damaged by the sorting process. We also observed the shape transforms of photosystem I nanocrystals, demonstrating that our device can optimize data collection for the shape transform-based phasing method. Using simulations, we show that narrow crystal size distributions can significantly improve merged data quality in serial crystallography. From this proof-of-concept work, we expect that the automated size-sorting of protein crystals will become an important step for sample production by reducing the amount of protein needed for a high quality final structure and the development of novel phasing methods that exploit inter-Bragg reflection intensities or use variations in beam intensity for radiation damage-induced phasing. This method will also permit an analysis of the dependence of crystal quality on crystal size.

36 MATERIALS SCIENCE↗

Life Cycle Inventory of Current Photovoltaic Module Recycling Processes in Europe

With the rapid and accelerating growth of PV module installation and an increase of PV modules from the nineteen eighties and nineties reaching the end of their 30 year lifespan, their proper end of life treatment gets into focus. This report deals with the approaches, the environmental impacts and the recovered materials of PV module recycling. In this report, the environmental life cycle assessment of the current generation recycling of crystalline silicon (c-Si) and cadmium telluride (CdTe) PV modules is described. Due to the still limited waste stream today, c-Si PV modules are mainly treated in recycling plants designed for treatment of laminated glass, metals or electronic waste. Only the bulk materials glass, aluminium and copper are recovered, while the cells and other materials such as plastics are incinerated. CdTe PV modules have been treated in dedicated recycling plants for many years and life cycle inventories of this process have been published. The semiconductor is recovered in addition to glass and copper. Life cycle inventories of the recycling of current c-Si and CdTe PV modules are compiled following two modelling approaches related to recycling. The cut-off approach uses economic allocation to divide the total efforts of the recycling process between the treatment of the used PV module and the recovered products. The end-of-life approach considers the recycling process separately from the potentially avoided burdens due to recovered materials. The life cycle inventories of c-Si PV module recycling are based on data obtained from four European recyclers surveyed between 2015 and 2016. For CdTe PV module recycling, the life cycle inventories were established based on published data for the First Solar recycling facility in Germany. The life cycle impact assessment is done based on six environmental indicators previously identified as most relevant for PV electricity: particulate matter, freshwater ecotoxicity, human toxicity non-cancer effects, human toxicity cancer effects, mineral, fossil and renewable resource depletion and climate change. The life cycle inventories according to the cut-off approach can be applied to complement existing life cycle inventory data on PV systems. The environmental impacts of the recycling of c-Si PV modules are very small (maximum 1.1 %) compared to the impacts caused by the production of a 3 kWp residential PV system mounted on a slanted roof. In the case of CdTe PV module recycling, the treatment of the PV panels has the highest but still rather minor contribution in the indicator climate change (4.8 %). The life cycle inventories according to the end-of-life approach allow an assessment of the net environmental benefits of recycling. The recovery of glass, metals, and semiconductor material from c-Si and CdTe PV modules causes lower environmental impacts than the extraction, refinement and supply of the respective materials from primary resources. The highest potential benefits are observed in the indicator mineral, fossil and renewable resource depletion. The data quality of the recycling of c-Si PV modules is classified as fair since only limited information is available. In contrast, the data quality of CdTe PV module recycling is considered very good. The study was financed by the Swiss Federal Office of Energy (SFOE) and carried out in the framework of the Task 12 of the Photovoltaic Powers System Programme (PVPS) of the International Energy Agency (IEA).

14 SOLAR ENERGY↗

C IV LINE-WIDTH ANOMALIES: THE PERILS OF LOW SIGNAL-TO-NOISE SPECTRA

Comparison of six high-redshift quasar spectra obtained with the Large Binocular Telescope with previous observations from the Sloan Digital Sky Survey shows that failure to correctly identify absorption and other problems with accurate characterization of the C IV λ1549 emission line profile in low signal-to-noise (S/N) data can severely limit the reliability of single-epoch mass estimates based on the C IV emission line. We combine the analysis of these new high-quality data with a reanalysis of three other samples based on high-S/N spectra of the C IV emission line region. We find that a large scatter between the Hβ- and C IV-based masses remains even for this high-S/N sample when using the FWHM to characterize the broad-line region velocity dispersion and the standard virial assumption to calculate the mass. However, we demonstrate that using high-quality data and the line dispersion to characterize the C IV line width leads to a high level of consistency between C IV- and Hβ-based masses, with <0.3 dex of observed scatter and an estimated ∼0.2 dex intrinsic scatter, in the mass residuals.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring Renewable Energy Opportunities in Select Southeast Asian Countries: A Geospatial Analysis of the Levelized Cost of Energy of Utility-Scale Wind and Solar Photovoltaics

The costs of renewable energy-based electricity generation have fallen precipitously in recent years to levels that are increasingly competitive with traditional generation such as fossil fuel-based generation. As these costs become increasingly competitive, private developers, policymakers, and energy system planners are searching for opportunities to harness high-quality renewable energy resources. Developing economies are setting ambitious targets and exploring how cost-effective, grid-connected renewable energy options can help power economic growth and meet growing electricity demands. This includes the member states of the Association of Southeast Asian Nations (ASEAN) that are determined to reach a target of 23% of renewable energy in the region's total primary energy supply by 2025. A critical gap to identifying opportunities and scaling up renewable energy is the lack of quality data and analyses to support decisions on the investment and deployment of renewables - including wind and solar photovoltaics (PV). This work supports decision making by providing high-quality data and spatial analysis of the cost of utility-scale wind and solar PV generation in select countries of Southeast Asia - specifically, the ASEAN member states. Generation costs are expressed as the levelized cost of energy (LCOE) - a commonly used metric that represents the net present value of the unit cost of electricity during the lifetime of a particular electricity generation technology. This is the first spatial estimate of LCOE for these technologies within the ASEAN member states - providing insights into the roles that renewable energy resource quality and other factors may play in generation costs.

14 SOLAR ENERGY↗

The minimum crystal size needed for a complete diffraction data set

A formula for absolute scattering power is derived to include spot fading arising from radiation damage and the crystal volume needed to collect diffraction data to a given resolution is calculated. In this work, classic intensity formulae were united with an empirical spot-fading model in order to calculate the diameter of a spherical crystal that will scatter the required number of photons per spot at a desired resolution over the radiation-damage-limited lifetime. The influences of molecular weight, solvent content, Wilson B factor, X-ray wavelength and attenuation on scattering power and dose were all included. Taking the net photon count in a spot as the only source of noise, a complete data set with a signal-to-noise ratio of 2 at 2 Å resolution was predicted to be attainable from a perfect lysozyme crystal sphere 1.2 µm in diameter and two different models of photoelectron escape reduced this to 0.5 or 0.34 µm. These represent 15-fold to 700-fold less scattering power than the smallest experimentally determined crystal size to date, but the gap was shown to be consistent with the background scattering level of the relevant experiment. These results suggest that reduction of background photons and diffraction spot size on the detector are the principal paths to improving crystallographic data quality beyond current limits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Salt Effects on Li-Ion Exchange Kinetics of Na 2 Mg 2 P 3 O 9 N: Systematic In Situ Synchrotron Diffraction Studies

The kinetics and thermodynamics of solid-state ion exchange of Li+ into Na2Mg2P3O9N were investigated using in situ synchrotron X-ray diffraction methods for a series of Li-containing salts, allowing systematic trends with general applicability to ion exchange reactions to be elucidated. The collection of data for a wide range of reaction conditions was enabled through the use of a novel multiwell sample environment which leverages the ability of the synchrotron beamline to rapidly (similar to 1 s) collect high-quality data suitable for monitoring reaction progress. From these data, it was possible to resolve the influence of salt choice and salt concentration on the ion exchange reaction kinetics. Furthermore, by carrying out experiments at different temperatures, initial estimates of activation energies were obtained. It was generally found that the ion exchange reaction kinetics strongly depended on the salt chosen as the ion source rather than being primarily determined by the ion mobility of the ceramic.

Cosby, Monty R.↗

Flatfielding of hybrid pixel detectors in tender x-ray scattering

The ability of the soft matter interfaces beamline at National Synchrotron Light Source II to access x-ray energy in the tender x-ray regime, i.e., from 2.1 to 5 keV, enables new resonant x-ray scattering studies at the sulfur K-edge and others. We present a new approach to correct data acquired in the tender x-ray regime with a Pilatus3 detector in order to improve the data quality and to correct the various artifacts inherent to hybrid pixel detectors, such as variations in modules’ efficiency or noisy detector module junctions. Further, this new flatfielding significantly enhances the data quality and enables detection of weak scattering signals.

47 OTHER INSTRUMENTATION↗

New methods for indexing multi-lattice diffraction data

A new indexing method is presented which is capable of indexing multiple crystal lattices from narrow wedges of data. The efficacy of this method is demonstrated with both semi-synthetic multi-lattice data and real multi-lattice data recorded from microcrystals of ∼1 µm in size. A new indexing method is presented which is capable of indexing multiple crystal lattices from narrow wedges of diffraction data. The method takes advantage of a simplification of Fourier transform-based methods that is applicable when the unit-cell dimensions are known a priori. The efficacy of this method is demonstrated with both semi-synthetic multi-lattice data and real multi-lattice data recorded from crystals of ∼1 µm in size, where it is shown that up to six lattices can be successfully indexed and subsequently integrated from a 1° wedge of data. Analysis is presented which shows that improvements in data-quality indicators can be obtained through accurate identification and rejection of overlapping reflections prior to scaling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-D-204-03: Comparison of Patient Positioning Methods Through Modeling of Acute Rectal Toxicity in Intensity Modulated Radiation Therapy for Prostate Cancer. Does Quality of Data Matter More Than the Quantity?

Purpose: To determine if differences in patient positioning methods have an impact on the incidence and modeling of grade >=2 acute rectal toxicity in prostate cancer patients who were treated with Intensity Modulated Radiation Therapy (IMRT). Methods: We compared two databases of patients treated with radiation therapy for prostate cancer: a database of 79 patients who were treated with 7 field IMRT and daily image guided positioning based on implanted gold markers (IGRTdb), and a database of 302 patients who were treated with 5 field IMRT and daily positioning using a trans-abdominal ultrasound system (USdb). Complete planning dosimetry was available for IGRTdb patients while limited planning dosimetry, recorded at the time of planning, was available for USdb patients. We fit Lyman-Kutcher-Burman (LKB) model to IGRTdb only, and Univariate Logistic Regression (ULR) NTCP model to both databases. We perform Receiver Operating Characteristics analysis to determine the predictive power of NTCP models. Results: The incidence of grade >= 2 acute rectal toxicity in IGRTdb was 20%, while the incidence in USdb was 54%. Fits of both LKB and ULR models yielded predictive NTCP models for IGRTdb patients with Area Under the Curve (AUC) in the 0.63 – 0.67 range. Extrapolation of the ULR model from IGRTdb to planning dosimetry in USdb predicts that the incidence of acute rectal toxicity in USdb should not exceed 40%. Fits of the ULR model to the USdb do not yield predictive NTCP models and their AUC is consistent with AUC = 0.5. Conclusion: Accuracy of a patient positioning system affects clinically observed toxicity rates and the quality of NTCP models that can be derived from toxicity data. Poor correlation between planned and clinically delivered dosimetry may lead to erroneous or poorly performing NTCP models, even if the number of patients in a database is large.

60 APPLIED LIFE SCIENCES↗

Special Report on Review of "The Department of Energy's Quality Assurance Process for Prime Recipients' Reporting for the American Recovery and Reinvestment Act"

The American Recovery and Reinvestment Act of 2009 (Recovery Act) was established to jumpstart the U.S. economy, create or save millions of jobs, spur technological advances in health and science, and invest in the Nation's energy future. The Department of Energy (Department) will receive an unprecedented $37 billion in Recovery Act funding to support a variety of science, energy, and environmental initiatives. The majority of the funding received by the Department will be allocated to various recipients through grants, cooperative agreements, contracts, and other financial instruments. To ensure transparency and accountability, the Office of Management and Budget (OMB) requires that recipients report on their receipt and use of Recovery Act funds on a quarterly basis to FederalReporting.gov. OMB also specifies that Federal agencies should develop and implement formal procedures to help ensure the quality of recipient reported information. Data that must be reported by recipients includes total funding received; funds expended or obligated; projects or activities for which funds were obligated or expended; and the number of jobs created and/or retained. OMB requires that Federal agencies perform limited data quality reviews of recipient data to identify material omissions and/or significant reporting errors and notify the recipients of the need to make appropriate and timely changes to erroneous reports. As part of a larger audit of recipient Recovery Act reporting and performance measurement and in support of a Government-wide review sponsored by the Recovery Accountability and Transparency Board, we completed an interim review to determine whether the Department had established a process to ensure the quality and accuracy of recipient reports. Our review revealed that the Department had developed a quality assurance process to facilitate the quarterly reviews of recipient data. The process included procedures to compare existing information from the Department's financial information systems with that reported to FederalReporting.gov by recipients. In addition, plans were in place to notify recipients of anomalies and/or errors exposed by the quality assurance process. While the Department has made a good deal of progress in this area, we did, however, identify several issues which could, if not addressed, impact the effectiveness of the quality assurance process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The recent absolute total np and pp cross section determinations: quality of data description and prediction of experimental observables

The absolute total cross sections for np and pp scattering below 1000 MeV are determined based on partial-wave analyses (PWAs) of nucleon-nucleon scattering data. These cross sections are compared with the most recent ENDF/B-VII.0 and JENDL-3.3 data files, and the Nijmegen PWA. Systematic deviations from the ENDF/B-VII.0 and JENDL-3.3 evaluations are found to exist in the low-energy region. Comparison of the np evaluation with the result of most recent np total and differential cross section measurements will be discussed. Results of those measurements were not used in the evaluation database. A comparison was done to check a quality of evaluation and its capabilities to predict experimental observables. Excellent agreement was found between the new experimental data and our PWA predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of Tank 23H (HTF-23-19-23, -24, -25) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 23H to support ECP and CCP. The results of the analysis indicate the concentrations of species in Tank 23H increase with depth in the tank. The sample obtained from the lowest level of 60” from the bottom of the tank shows the highest concentrations for most species analyzed. The surface sample and the 140” sub-surface sample show similar compositions with the sub-surface sample being slightly more concentrated, and both are more dilute than the lowest 60” sub-surface sample for most species analyzed. The total uranium concentration in the three Tank 23H samples show a slight increase from the surface sample to the next lower sub-surface sample, but then a slight decrease in the uranium concentration in the lowest sub-surface sample. The U-235 weight fraction ranges from 0.94-1.2% in the Tank 23H samples. The sum of the major cations versus the sum of the major anions shows a difference of ~5% or less for all three of the Tank 23H samples indicating good data quality for the non-radioactive analytes in the table. Small %RSD values for the replicate analyses with the exception of species close to the detection limit (e.g., Fe) provide another indication of good data quality for the non-radioactive species. The silicon concentrations measured in the Tank 23H samples were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗