Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cryogenic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Modeling of Cryogenic Heated-Tube Flow Boiling Experiments of Hydrogen and Helium With the Generalized Fluid System Simulation Program

Accurate modeling of cryogenic boiling heat transfer is vital for the development of extended-duration space missions. Such missions may require the transfer of cryogenic propellants from in-space storage depots or the cooling of nuclear reactors. Purdue University in collaboration with NASA has assembled a database of cryogenic flow boiling data points from heated-tube experiments dating back to 1959, which has been used to develop new flow boiling correlations specifically for cryogens. Computational models of several of these experiments have been constructed in the Generalized Fluid System Simulation Program (GFSSP), a network flow code developed at NASA’s Marshall Space Flight Center. The new Purdue-developed universal correlations cover the full boiling curve: onset of nucleate boiling, nucleate boiling, critical heat flux, and film boiling. These correlations have been coded into GFSSP user subroutines. The fluids modeled in this study are liquid hydrogen and liquid helium. Predictions of local wall temperature and pressure drop are presented and compared to the test data.

multi-phase flow↗

Cryogenic Extension of NASA Species Polynomials Using Hydrogen and Oxygen at Stoichiometry

NASA has been conducting research in Rotating Detonation Rocket Engines (RDREs) for several years. A recent test at the Marshall Spaceflight Center has successfully shown operation of a RDRE that ran for 251 seconds which had combustion chamber cryogenic inlet conditions [1]. However, an overall pressure gain was not observed in the performance of the engine. Such an indication could mean an optimal chamber design is yet to be discovered. Such a design could significantly reduce parasitic pressure loses and improve overall engine efficiency beyond that of conventional rockets. To investigate different chamber configurations, new CFD capability is needed to accurately capture cryogenic thermophysical and transport property data. Such an effort is currently part of NASA’s Early Career Initiative (ECI) program. This paper focuses on the thermophysical property mixture model approach that makes use of NASA’s polynomial fits of species and another cryogenic model chosen from NIST’s Refprop program. Presented in this paper are results of a 1D denotation CFD simulation of stoichiometric Hydrogen and Oxygen mixture at a cryogenic upstream condition.

Combustion↗

CFD Modeling of Bi-Directional PMD inside Cryogenic Propellant Tanks Onboard Parabolic Flights

Future cryogenic propulsion systems will require efficient methods with which to transfer cryogenic propellants from a depot storage tank to a customer receiver tank to minimize cost and maximize reusability. The Reduced Gravity Cryogenic Transfer project is currently developing advanced cryogenic fluid management technology and developing and validating new numerical models for three phases of transfer: line chilldown, tank chilldown, and tank fill. Additionally, multiple liquid nitrogen (LN 2 ) parabolic flight transfer rigs are being designed by universities and NASA to investigate the gravitational sensitivities that exist in these three technologies. In order to maximize the collection of low-g data during flights, it is required to extract as much (LN 2 as possible from the supply tank, despite variable gravity levels. The purpose of this paper is to present computational fluid dynamics (CFD) volume of fluid simulations of (LN 2 behavior in the supply tank onboard parabolic flights to validate the optimal design of a bi-directional propellant management device (PMD) using the commercial software FLOW-3D. A parametric study is conducted on the effects of gravity level, fill level, pore size, open area, thickness, and type of baffle on PMD performance. Based on results, the PMD as designed exceeds the targeted expulsion efficiency.

Jason Hartwig↗

Lessons Learned From A Cryogenic Motor Configuration Study for Aircraft Propulsion

Cryogenic electric machines are a promising technology for multi megawatt electric aircraft drivetrains. Superconducting stators that make use of low AC loss superconducting wires are considered to be a key component for these cryogenic machines. NASA has undertaken 6-year technical challenge to address this need by designing a 5 MW superconducting motor and cryogenic drive and developing multi-MW prototypes. This poster shares the lessons learned from a completed design study that evaluated several configurations of a 5 MW cryogenic motor for this application. The lessons are drawn from a qualitative study of 16 configurations and a quantitative study of 8 down selected configurations. The quantitative study involved using a motor design code based on analytical calculations (electromagnetic, thermofluid, mechanical, and motor sizing) to determine each configuration’s Pareto front of total efficiency and total specific power. This poster builds upon preliminary results that were previously presented by (1) reporting final results based on a revised design code for each configuration, including a considerable increase in fidelity for a novel radial flux motor and (2) making a down selection of the configuration for future detailed design and demonstration and documenting the rationale for the selection.

Superconductors↗

Cryogenic immersion microscope

A cryogenic immersion microscope whose objective lens is at least partially in contact with a liquid reservoir of a cryogenic liquid, in which reservoir a sample of interest is immersed is disclosed. When the cryogenic liquid has an index of refraction that reduces refraction at interfaces between the lens and the sample, overall resolution and image quality are improved. A combination of an immersion microscope and x-ray microscope, suitable for imaging at cryogenic temperatures is also disclosed.

Le Gros, Mark↗

Cryogenic exciter

The disclosed technology is a cryogenic static exciter. The cryogenic static exciter is connected to a synchronous electric machine that has a field winding. The synchronous electric machine is cooled via a refrigerator or cryogen like liquid nitrogen. The static exciter is in communication with the field winding and is operating at ambient temperature. The static exciter receives cooling from a refrigerator or cryogen source, which may also service the synchronous machine, to selected areas of the static exciter and the cooling selectively reduces the operating temperature of the selected areas of the static exciter.

47 OTHER INSTRUMENTATION↗

A model for manuscript submitted to the nth IIR conference on overview of the long-baseline neutrino facility cryogenic system

The Deep Underground Neutrino Experiment (DUNE) collaboration is developing a multi-kiloton Long-Baseline neutrino experiment that will be located one mile underground at the Sanford Underground Research Facility (SURF) in Lead, SD. In the present design, detectors will be located inside four cryostats filled with a total of 68,400 ton of ultrapure liquid argon, at the level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The Long-Baseline Neutrino Facility (LBNF) is developing the conventional facilities and cryogenics infrastructure supporting this experiment. The cryogenics system is composed of several sub-systems: External/Infrastructure, Proximity, and Internal cryogenics. It will be engineered, manufactured, commissioned, and qualified by an international engineering team. This contribution highlights the main features of the LBNF cryogenic system. It presents its performance, functional requirements and modes of operations. As a result, it also details the status of the design, present and future needs.

43 PARTICLE ACCELERATORS↗

Status of the LBNF Cryogenic System

The Sanford Underground Research Facility (SURF) will host the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about a mile underground in Lead, SD. In the current configuration four cryostats will contain a modular detector and a total of 68,400 ton of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The Long-Baseline Neutrino Facility (LBNF) provides the conventional facilities and the cryogenic infrastructure to support DUNE. The system is comprised of three sub-systems: External/Infrastructure, Proximity and Internal cryogenics. An international engineering team will design, manufacture, commission, and qualify the LBNF cryogenic system. This contribution presents the models of operations, layout and main features of the LBNF cryogenic system. The expected performance, the functional requirements and the status of the design are also highlighted.

43 PARTICLE ACCELERATORS↗

Hydrocyclone for cryogenic gas-vapor separation

A hydrocyclone for separating a vapor from a carrier gas is disclosed. The hydrocyclone comprises one or more nozzles. A cryogenic liquid is injected to a tangential feed inlet at a velocity that induces a tangential flow and a cyclone vortex in the hydrocyclone. The carrier gas is injected into the cryogenic liquid, causing the vapor to dissolve, condense, desublimate, or a combination thereof, forming a vapor-depleted carrier gas and a vapor-enriched cryogenic liquid. The vapor-depleted carrier gas is drawn through a vortex finder and the vapor-enriched cryogenic liquid is drawn through an apex nozzle outlet. In this manner, the vapor is removed from the carrier gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Two-Phase Dense Fluid Expander for Advanced Cryogenic Air Separation and Low-Grade Heat Recovery

Cryogenic air separation represents the state-of-the-art technology to produce oxygen to feed coal gasification units. Given the maturity of this technology, it is difficult to identify opportunities to improve process efficiency and reduce the cost of the oxygen produced. However, Air Products conducted research and a feasibility investigation into the use of a two-phase (liquid-vapor) dense fluid expander (DFE) to improve the overall efficiency of cryogenic air separation. Demonstration of this novel concept was intended to allow two important process improvements: 1) elimination of the need for the DFE discharge to be single phase 2) expansion of the operating region of expanders in ASU service. Expanding the scope of turboexpander application beyond current application limits and traditional device designs would allow an increase in power recovery, and application of refrigeration and power recovery at new locations in process cycles would also enable the implementation of new process concepts. These new process concepts include power recovery from compression waste heat and refrigeration extraction and power recovery by replacing let-down valves with two-phase DFEs. Considering the maturity of cryogenic air separation, these new process options could represent a step change in power reduction and provide significant savings in operating costs. These new concepts would be particularly well-suited to large-scale oxygen production by cryogenic air separation and would enhance the economics of producing oxygen for use in coal gasification processes. Rotoflow, an Air Products business unit, manufactures dense fluid expanders in Pennsylvania for sites around the world. This project was executed in two phases, which are illustrated in Figure 1 below. Phase 1 consisted of a feasibility investigation of multiple applications of two-phase DFEs. In Phase 2, devices were identified, designed, fabricated and tested to explore the feasibility of commercial applications of DFEs operating in two-phase service. Engineering and testing were performed by personnel in Air Products’ Rotoflow business unit, with coordination with other Air Products business units.

01 COAL, LIGNITE, AND PEAT↗

Fabrication and installation of the Mu2e cryogenic distribution system

The muon-to-electron conversion (Mu2e) experiment at Fermilab will be used to search for the charged lepton flavor-violating conversion of muons to electrons in the field of an atomic nucleus. The Mu2e experiment is currently in the construction stage. The scope of this paper is the cryogenic distribution system and superconducting power leads for four superconducting solenoid magnets: Production Solenoid (PS), an Upstream and Downstream Transport Solenoids (TSu and TSd) and Detector Solenoid (DS). The design of the cryogenic distribution system and the fabrication of several sub-systems was reported previously. This paper reports on additional fabrication and installation progress that has been performed over the past two years. Lessons learned during fabrication and testing of the cryogenic distribution system components are described. In particular, the challenges and solutions implemented for aluminum welding are reported. A description of the process used to qualify the welding procedure and welders for welding the aluminium stabilized NbTi superconducting power leads is provided. Additionally, the progress made with regards to installing the power leads into the cryogenic Feedboxes is covered.

White, Michael J.↗

Automated cryogenic refilling system

An improved system and method for the automated refilling of cryogenic helium is provided. In one embodiment, the system includes a dewar in fluid communication with a liquid helium cryostat through a cryogen transfer line. A controller regulates operation of a three-way valve to pre-cool the transfer line and to cause gaseous helium to flow to the dewar and force liquid helium through the transfer line into the cryostat. The controller is coupled to the output of a cryogenic level sensor, such that the controller regulates the helium liquid level within the cryostat. During filling cycles, the dewar liquid level is also monitored by the cryogenic level sensor and an alarm sounds if the dewar liquid level is undesirably low. Between filling cycles, the controller is operable to ventilate the dewar through a solenoid vent valve in fixed time intervals to ensure the dewar pressure is sufficiently low so as to not bleed liquid helium into the cryostat.

Ruiz-Rodriguez, Mariano M.↗

Flexible linkages for thermal management at cryogenic temperatures

Cryogenic system design often presents the competing requirements of thermal coupling between components while de-coupling them structurally. Good thermal coupling is necessary for adequate thermal management during cryogenic operation of the system and to reduce the cooldown time from the ambient to cryogenic temperature. Structural de-coupling is essential to reduce thermal stresses during cooldown, mitigate the trasmission of vibration and loads to sensitive and/or fragile components, and compensate for integration misalignments. Flexible thermal links (FTLs) are an essential component of cryogenic systems that provides a balance between thermal coupling and structural isolation.

42 ENGINEERING↗

Pressure safety approach for PIP-II cryogenic distribution system and cryomodules

The Proton Improvement Plan-II (PIP-II) is a superconducting linear accelerator being built at Fermilab that will provide 800 MeV proton beam for neutrino production. The linac consists of a total of twenty-three (23) cryomodules of five (5) different types. Cooling is required at 2K, 5K and 40K. The Cryogenic Distribution System (CDS) consists of a Distribution Valve Box, ~285 m of cryogenic transfer line, modular Bayonet Cans to interface with cryomodules, and a Turnaround Can. The cryogenic system must provide protection from over-pressure by sizing pressure relief devices for all volumes and process line circuits. The cryomodule cavity circuits have dual pressure ratings, 4.1 bara when cold and 2.05 bara when warm (T>80K). Worst case relieving cases will be identified. The methods for determining heat flux will be presented. For the relieving occurring in the linac tunnel, flow must vent to outside to avoid an oxygen deficiency hazard. Also, we will present vacuum vessel relief sizing to protect the cryogenic distribution system vacuum shells from over pressure during an internal line rupture. The project is funded by US DOE Offices of Science, High Energy Physics.

43 PARTICLE ACCELERATORS↗

DC Cryogenic Modeling of Open-Source SkyWater 130 nm MOSFETs at 77 K Using BSIM4

Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrogen temperature. We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS) and shows no dependence on drain voltage. Due to the open-source nature of SKY130, we have made our models publicly available on Github. We hope this work will continue the trend for democratizing circuit design at cryogenic temperatures in high-energy physics by enabling open access to accurate cryogenic CMOS device models at 77 K.

Beall, F. [Texas U., Arlington]↗

Cryogenic RF characterization of the MAGO cavity for high-frequency gravitational-wave detection

Superconducting radio-frequency (SRF) cavities are promising resonant sensors for gravitational-wave detection in the kHz-MHz frequency range. We report the cryogenic RF characterization of a prototype superconducting niobium cavity with an unconventional geometry designed for narrow electromagnetic mode separation. Following an adapted surface preparation procedure, cryogenic tests were performed at Fermilab and DESY at temperatures down to 2 K. Mechanical tuning at room temperature achieved a mode splitting of approximately 11 kHz at cryogenic temperature. High electromagnetic quality factors consistent with previous prototype cavities were measured. The measurements further revealed phase transfer characteristics relevant for stable low-level RF control as well as indications of mode coupling potentially caused by one-point multipacting. In addition, first cryogenic measurements of the mechanical eigenmodes yielded mechanical quality factors significantly below commonly assumed theoretical values. These results demonstrate the successful application of established SRF preparation and characterization techniques to a non-standard resonator geometry and provide important experimental input for the development of future SRF-based gravitational-wave detectors.

Dokuyucu, Can [DESY]↗

Programmable Cryogenic Memory in a Ge/GeSi Heterostructure

Programmable memory components that operate optimally at cryogenic temperatures are essential for cryogenic computing architectures that seek to implement computing-in-memory. In this work, we demonstrate highly programmable memory in a Ge/GeSi heterostructure field-effect transistor (HFET). To operate, the HFET is gated to introduce positive carriers within the Ge quantum well, creating a high-conductance state. We show that this device can be set to a low-conductance state by sweeping a negative bias on the device drain, and reset it to its high-conductance state by sweeping a more positive bias on the device gate, thereby creating memory. We then determine that the device can be programmed within a 103 range of conductances using either the SET or the RESET operation. We propose that memory is achieved through charge trapping as carriers tunnel out of the quantum well, and that altering the density and spatial distribution of carriers modulates the device conductance. This mechanism exhibits endurance over 1000 cycles at temperatures ≤ 25 K, suggesting that the carrier traps are located at the oxide-semiconductor interface. As a first demonstration of programmable conductance in a Ge/GeSi HFET, this work highlights the potential of group-IV HFETs to perform as analog cryogenic memory components.

cryogenic memory↗

Polyamide 66 as a Cryogenic Dielectric

Improvements in superconductor and cryogenic technologies enable novel power apparatus, \eg, cables, transformers, fault current limiters, generators, \etc, with better device characteristics than their conventional counterparts. In these applications electrical insulation materials play an important role in system weight, footprint (size), and voltage level. The trend in the electrical insulation material selection has been to adapt or to employ conventional insulation materials to these new systems. However, at low temperatures, thermal contraction and loss of mechanical strength in many materials make them unsuitable for superconducting power applications. In this paper, a widely used commercial material was characterized as a potential cryogenic dielectric. The material is used in ``oven bag'' a heat-resistant polyamide (nylon) used in cooking (produced by Reynolds\textregistered, Richmond, VA, USA). It is first characterized by Fourier transform infrared and x-ray diffraction techniques and determined to be composed of polyamide 66 (PA66) polymer. Secondly the complex dielectric permittivity and dielectric breakdown strength of the PA66 films are investigated. The dielectric data are then compared with data reported in the literature. A comparison of dielectric strength with a widely used high-temperature superconductor electrical insulation material, polypropylene-laminated paper (PPLP\texttrademark\ a product of Sumitomo Electric Industries, Japan), is provided. It is observed that the statistical analysis of the PA66 films yields 1\% failure probability at $127\ \kilo\volt\milli\meter^{-1}$; this value is approximately $46\ \kilo\volt\milli\meter^{-1}$ higher than PPLP\texttrademark. It is concluded that PA66 may be a good candidate for cryogenic applications. Finally, a summary of dielectric properties of some of the commercial tape insulation materials and various polymers is also provided.

36 MATERIALS SCIENCE↗