Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Dynamics of magnetic evaporative beamline cooling for the preparation of cold atomic beams

The most sensitive direct neutrino mass searches today are based on measurement of the end point of the 𝛽 spectrum of tritium to infer limits on the mass of the unobserved neutrino. To avoid the smearing associated with the distribution of molecular final states in the T-He molecule, the next generation of these experiments will need to employ atomic (T) rather than molecular (T 2 ) tritium sources, at currents of at least 10 15 atoms per second. Following production, atomic T can be trapped in gravitational and/or magnetic bottles for 𝛽 spectrum experiments, if and only if it can first be cooled to millikelvin temperatures. Accomplishing this cooling presents substantial technological challenges. The Project 8 collaboration is developing a technique based on magnetic evaporative cooling along a beamline (MECB) for the purpose of cooling T to feed a magnetogravitational trap that also serves as a cyclotron radiation emission spectroscope. Initial tests of the approach are planned in a pathfinder apparatus using atomic Li. Here, this paper presents a method for analyzing the dynamics of the MECB technique and applies these calculations to the design of systems for cooling and slowing of atomic Li and T. A scheme is outlined that could provide a current of T at the millikelvin temperatures required for the Project 8 neutrino mass search.

atom optics↗

Improvements to Passive Heat Removal Systems in SAS4A/SASSYS-1

Safe operation of a sodium cooled fast reactor (SFR) can be significantly aided by heat removal systems that do not rely on active power, but function using passive means. Passive heat removal from such reactors can employ systems that extract heat directly from sodium coolant by utilizing heat exchangers submerged in the coolant and natural circulation of a metal fluid sodium (or sodium potassium eutectic) to heat exchangers (generally air cooled) externally located. These types of systems are generally called Direct Reactor Auxiliary Cooling Systems (DRACS). Another type of passive heat removal system particularly suitable for pool-type SFRs relies on indirect extraction of heat by utilizing air flow in an annular region surrounding the reactor guard vessel which discharges the heat via the chimney effects to the atmosphere. These systems are generally called Reactor Vessel Auxiliary Cooling Systems (RVACS).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advancing Sustainability in Data Centers: Evaluation of Hybrid Air/Liquid Cooling Schemes for IT Payload Using Sea Water

Abstract-The growth in cloud computing, Big Data, AI and high-performance computing (HPC) necessitate the deployment of additional data centers (DC's) with high energy demands. The unprecedented increase in the Thermal Design Power (TDP) of the computing chips will require innovative cooling techniques. Furthermore, DC's are increasingly limited in their ability to add powerful GPU servers by power capacity constraints. As cooling energy use accounts for up to 40% of DC energy consumption, creative cooling solutions are urgently needed to allow deployment of additional servers, enhance sustainability and increase energy efficiency of DC's. The information in this study is provided from Start Campus' Sines facility supported by Alfa Laval for the heat exchanger and CO 2 emission calculations. The study evaluates the performance and sustainability impact of various data center cooling strategies including an air-only deployment and a subsequent hybrid air/water cooling solution all utilizing sea water as the cooling source. Here we evaluate scenarios from 3 MW to 15+1 MW of IT load in 3 MW increments which correspond to the size of heat exchangers used in the Start Campus' modular system design. This study also evaluates the CO 2 emissions compared to a conventional chiller system for all the presented scenarios. Results indicate that the effective use of the sea water cooled system combined with liquid cooled systems improve the efficiency of the DC, plays a role in decreasing the CO 2 emissions and supports in achieving sustainability goals.

97 MATHEMATICS AND COMPUTING↗

Integral and Separate Effects Test Facilities To Support Water Cooled Small Modular Reactors: A Review

This study reviews previous experimental facilities and test programs relevant to water-cooled reactor system design and analysis to meet regulatory compliances. This study aims to find the best solution for designing the required experiments, obtaining necessary test data, and verifying the developed computer code/models to support the new reactor design and development while minimizing cost and time while leveraging experiences from previous facilities to minimize. Nuclear reactor licensing requires supportive design, analysis, and experimental results to ensure the safety of the full-scale prototype reactor in regular operation, as well as during postulated accident scenarios. These reactor design analyses are generally performed using system codes and other associated simulation tools that require assessment, verification and validation using an appropriate experimental dataset. Experimental facilities used for reactor system safety analysis and system code assessments are categorized into integral effects test (IET) and separate effects test (SET) facilities. Further, these IET and SET experiments and studies use geometrically scaled systems to reproduce the prototype system behavior at a reasonable cost, albeit with some scaling-related distortions. The design challenge of these model facilities is to identify and minimize scaling distortions while reproducing the most important operational phenomena in steady-state operation and in postulated accident scenarios. Lessons learned from previous experimental facilities, models, and correlations can support the development of new multipurpose, scaled, hybrid, integrated, and modular experimental facilities for advanced light water-cooled small modular reactors (SMRs). Successful operation of these facilities can significantly reduce upfront reactor development and demonstration costs and time to deployment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Melting point of group IV and V transition metal diborides

The environmental conical nozzle levitator system enables cooling trace experiments above 4000 K. These cooling trace experiments were used to determine the melting points through observation of thermal arrest of group IV and V transition metal diborides (TiB 2 , T m = 3313 ± 33 K; ZrB 2 , T m = 3404 ± 38 K; HfB 2 , T m = 3529 ± 33 K; and TaB 2 , T m = 3284 ± 10 K; note: mean ± 2 standard error). Temperature measurements were conducted utilizing dual single-color pyrometers at wavelengths of 0.9 and 0.65 µm. This system utilizes aerodynamic levitation and dual laser heating to achieve temperatures approaching 4000 K. The samples were synthesized from commercial powders using ceramic gel-casting to produce high-density spherical components. The measurements obtained were compared to previously reported melting temperature values and were generally found to be in agreement with most of the published values.

Materials science↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗

Large Kohn Anomaly and Phonon Collapse Induced by Charge Density Wave in UPt 2⁢ Si 2

Using high-energy-resolution inelastic x-ray scattering, we observe anomalous softening and damping of the transverse acoustic phonon in UPt 2 ⁢Si 2 as the system is cooled toward the charge density wave (CDW) transition temperature 𝑇 CDW . The phonon exhibits a marked Kohn-type anomaly around the CDW wave vector 𝑄 CDW and becomes overdamped within a finite momentum range already well above 𝑇 CDW . The dispersion anomaly is consistent with potential Fermi surface nesting, which together with the extended phonon collapse indicates strong electron-phonon coupling. The transition temperature estimated from the phonon softening is markedly lower than 𝑇 CDW , consistent with a primarily electronic instability rather than a phonon-driven transition. In conclusion, our results establish UPt 2⁢ Si 2 as a prime example of a strongly correlated electron CDW system with exceptionally strong electron-phonon coupling driving phonon softening and collapse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Clean Water Production in Cooling Towers

This project developed and demonstrated a novel technology that produces clean water from cooling tower recirculating water by using the natural evaporation and condensation cycle inside cooling towers. The system captures the escaping plume and converts blowdown quality water into high purity water suitable for on-site reuse such as boiler feed. The technology uses electric fields to ionize exhaust plumes, charge the entrained droplets, and direct them toward collection electrodes where they coalesce and flow downward. This allows water recovery at a low energy cost while reducing visible plume emissions. In addition, we developed a complementary software platform that improves overall cooling tower performance. The system uses wireless sensors and physics-based machine learning algorithms to optimize key parameters of the cooling process. For power generation facilities, this increases the thermal efficiency of the cooling loop and condenser, resulting in measurable cycle efficiency gains. Improvements of one percent or more can deliver significant increases in electricity production for the same fuel input.

01 COAL, LIGNITE, AND PEAT↗

Towards Energy-Positive Buildings through a Quality-Matched Energy Flow Strategy

Current strategies for net-zero buildings favor envelopes with minimized aperture ratios and limiting of solar gains through reduced glazing transmittance and emissivity. This load-reduction approach precludes strategies that maximize on-site collection of solar energy, which could increase opportunities for net-zero electricity projects. To better leverage solar resources, a whole-building strategy is proposed, referred to as “Quality-Matched Energy Flows” (or Q-MEF): capturing, transforming, buffering, and transferring irradiance on a building’s envelope—and energy derived from it—into distributed end-uses. A mid-scale commercial building was modeled in three climates with a novel Building-Integrated, Transparent, Concentrating Photovoltaic and Thermal fenestration technology (BITCoPT), thermal storage and circulation at three temperature ranges, adsorption chillers, and auxiliary heat pumps. BITCoPT generated electricity and collected thermal energy at high efficiencies while transmitting diffuse light and mitigating excess gains and illuminance. The balance of systems satisfied cooling and heating demands. Relative to baselines with similar glazing ratios, net electricity use decreased 71% in a continental climate and 100% or more in hot-arid and subtropical-moderate climates. Total EUI decreased 35%, 83%, and 52%, and peak purchased electrical demands decreased up to 6%, 32%, and 20%, respectively (with no provisions for on-site electrical storage). Decreases in utility services costs were also noted. These results suggest that with further development of electrification the Q-MEF strategy could contribute to energy-positive behavior for projects with similar typology and climate profiles.

54 ENVIRONMENTAL SCIENCES↗

Numerical analysis of air dehumidification through electrospray-enhanced vortical flow cyclone separator

The dehumidification of air is a highly energy-intensive process, typically requiring vapor compression systems to cool the air significantly below its dew point temperature. Here, this study numerically investigates air dehumidification achieved by electrostatic and dielectrophoresis forces in a converging duct and centrifugal principles in cyclone separators. An electrospray was employed to energize water droplets, which then captured water vapor via dielectrophoresis. A novelty of the present study is the inclusion of a cyclone separator positioned downstream of the electrospray. This combination increased the dehumidification efficiency and controlled the flow of the condensate. By integrating electrospray technology and applying an electric field, this study examines the impact of particle separation efficiency, pressure drops, and cyclone performance on air dehumidification. The control parameters for air dehumidification were investigated. Three cyclones were modelled for airflow rates of 5 cubic feet per minute [cfm] (0.0024 m 3 /s), 38 cfm (0.0179 m 3 /s), and 200 cfm (0.094 m 3 /s). The results indicated air dehumidification was up to 5.7 % under environmental conditions, similar to those used to validate the CFD model. The degree of air dehumidification was primarily influenced by the electric charge acquired by the water droplets, their flight trajectory, and the vorticity intensity within the cyclone. Air dehumidification could increase by up to 13 % by increasing the number of droplets injected into the air stream, the flight time, and the electrical charge. The breakdown electric field strength threshold near the electrospray was a limiting factor for further enhancing dehumidification performance. This study examines the optimization of an electro-assisted dehumidification system that includes cyclone-based droplet separation through numerical analysis. The results provide insights into the design of energy-efficient air treatment technologies.

42 ENGINEERING↗

Thermal Performance of Triply Periodic Minimal Surface Lattice Structures in Single-Phase Dielectric Fluid Cooling of Power Electronics

Additive manufacturing has transformed thermal management by enabling the production of complex, optimized geometries that conventional manufacturing methods cannot achieve. This study investigates the single-phase convective heat transfer performance of gyroid triply periodic minimal surface (TPMS) lattice structures with functional porosity. TPMS structures provide high surface area to volume ratios and are amenable to 3D printing. A gyroid numerical model was created and validated against an existing experimental study with a similar feature size to the investigated geometries. The TPMS structure has a periodic width of 1.6 mm, a length of 10 mm, and a height of 4 mm, with a functional porosity ranging from 0.5 to 0.8, decreasing with distance from the heated surface. Three different flow configurations were examined for an inlet fluid temperature of 70 °C. The inlet velocities range from 0.01 to 1.2 m/s, corresponding to a Reynolds number range of 10–900 with a heat flux of 50 W/cm 2 applied at the base. AmpCool ® AC-110 dielectric fluid (Prandtl number 59.5) was used as the coolant. Thermal performance and friction characteristics were studied for the three flow orientations. The parallel flow configuration was identified as the most efficient for heat removal. A detailed analysis of the numerical results highlights the underlying physics behind the thermal performance differences among the flow configurations.

33 ADVANCED PROPULSION SYSTEMS↗

Ambient energy for buildings: Beyond energy efficiency

The following Key Messages comprise the salient findings of this study: 1. Ambient energy (from sun, air, ground, and sky) can heat and cool buildings; provide hot water, ventilation and daylighting; dry clothes; and cook food. These services account for about three-quarters of building energy consumption and a third of total US demand. Biophilic design (direct and indirect connections with nature) is an intrinsic adjunct to ambient energy systems, and improves wellness and human performance. 2. The current strategy of electrification and energy efficiency for buildings will not meet our climate goals, because the transition to an all-renewable electric grid is too slow. Widespread adoption of ambient energy is needed. Solar-heated buildings also flatten the seasonal demand for electricity compared to all-electric buildings, reducing required production capacity and long-term energy storage. In addition, ambient-conditioned buildings improve resilience by remaining livable during power outages. 3. National policies, incentives, and marketing should be enacted to promote ambient energy use. Federal administrative priorities should reflect the importance of ambient energy for buildings. Use of ambient energy should be encouraged through existing and new building codes and standards. 4. Ambient energy system design tools are needed for architects, engineers, builders, building scientists, realtors, appraisers, and consumers. PVWatts is used over 100 million times per year for photovoltaic system design. A similar, simple, and accessible tool for ambient design is crucial. 5. Training on ambient energy is needed throughout secondary, post-secondary, and continuing education for workforce development. Currently, only about 10% of colleges teach courses on passive heating and cooling systems. 6. Ambient-conditioned buildings should be demonstrated in all US climate zones. Performance should be monitored and reported, with quantitative case studies made widely available. 7. While current technology is sufficient to build high-performance ambient buildings now, research is needed to develop new technologies to harness ambient energy more effectively and more economically. Such advancements will facilitate adoption of ambient energy technologies in a wider range of buildings, including retrofits. Examples include windows with much lower thermal losses, use of the building shell as thermal storage, alternative light-weight thermal storage systems, sky radiation cooling systems, automated controls for solar gains and passive cooling, and ground coupling.

14 SOLAR ENERGY↗

Safety-Related Instrumentation and Control Pilot Upgrade: Conceptual - Detailed Design Phase Report and Lessons Learned

Historically, regulatory barriers have precluded nuclear plant safety-related (SR) Instrumentation and Control (I&C) system modernizations. These barriers have been largely addressed by industry and United States Nuclear Regulatory Commission (NRC) efforts, including development of the License Amendment Request (LAR) Alternate Review (AR) process for digital I&C upgrades. The U.S. Department of Energy (DOE) and the Idaho National Laboratory (INL) are supporting a SR I&C pilot upgrade at the Limerick Generating Station (LGS) to demonstrate this process and capturing associated lessons learned for the benefit of industry. In 2021, a paper summarizing lessons learned as captured in INL/EXT-20-59809, Safety Related Instrumentation & Control Pilot Upgrade Initial Scoping Phase Implementation Report and Lessons Learned was presented at the 12th NPIC & HMIT conference. It is recommended that readers of this paper review reference 1 or the associated Nuclear Journal paper for context. This paper summarizes activities performed and lessons learned for the conceptual design phase and portions of the detailed design phase as captured in INL/RPT-23-XXXX, “Safety-Related Instrumentation and Control Pilot Upgrade: Conceptual - Detailed Design Phase Report and Lessons Learned.” The portions of the effort covered by reference 2 include conceptual design phase activities from December 2020, through completion in November 2021, and detailed design activities through September 2022. These efforts and associated detailed documentation in reference 3 are intended to support similar industry upgrades as a foundation stone for a Digital Transformation that will improve plant safety, reliability, and operational performance while lowering plant total cost of ownership.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Two-zone stratified wetwell model development and implementation for RELAP-7

The Reactor Core Isolation Cooling (RCIC) system consists of a turbine, pump and wetwell and is used in many US Boiling Water Reactors (BWRs) as an important heat removal system. The wetwell is a major heat sink within containment. Experimental investigations have shown that thermal stratification may occur in the wetwell during RCIC operation. Current systems-level analysis codes lack stratified wetwell models. Here, this paper describes the development of a stratified wetwell model for the RELAP-7 code. This paper uses a simple two-zone model for the wetwell water that can capture thermal stratification. This model assumes that a buoyant plume transports heat and mass from the steam injection site to the upper water zone. The buoyant plume assumption requires that steam is injected at a low enough rate so it adds negligible momentum. Model validation against experimental data shows similar trends of temperature field development in the suppression pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermoelectric heating and cooling–integrated dishwasher with thermal energy storage

Household dishwashers must address several performance goals: maximize washing and drying performance, while minimizing cycle duration, energy consumption, and water consumption. This study develops and examines a novel thermoelectric heating and cooling (TEHC) system with thermal energy storage applied to a household dishwasher (DW), aiming to improve the energy and drying performance of a commercially-available dishwasher while maintaining its washing performance, water consumption, and cycle duration. Experimental testing conducted on the novel TEHC-DW system demonstrates an 8.7% reduction in total energy consumption, lowering the per-cycle usage to 0.952 kWh, and a 40% reduction in energy consumption for internal water heating. The novel TEHC-DW system also demonstrates better drying performance, shortening the drying time by 42% to reach the same remaining moisture content as a commercially-available system. In addition, a resistance-capacitance network model is developed that predicts total drying time, total energy consumption, and the highest temperature reached in the tub (53.4 °C). The model accuracy is validated with experimental data (within ±1 K), and the model functions as a design tool via a parametric study to evaluate the next-generation design and the effect of the number of thermoelectric modules and thermoelectric driving force (i.e., current). Overall, this study demonstrates the potential for TEHC technology to improve energy efficiency and drying performance in household dishwashers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Underwater thermomagnetic generator for remote marine thermal energy harvesting and sensing

Thermomagnetic generators offer a promising approach for sustainable power generation in remote marine environments. Here, this study presents the design, thermal modeling, and experimental validation of a passively driven underwater thermomagnetic generator developed for powering ocean observation and monitoring sensors. The generator was evaluated under varying working fluids, thermal boundary conditions, and extended operation to assess real-world applicability. Two fluids, deionized water and silicone-based Thermal C5, were tested under simulated shallow- and deep-ocean conditions. Deionized water outperformed Thermal C5, especially in colder environments (~5°C), achieving a peak output of 2.7 mW due to larger temperature gradients and enhanced convective-evaporative heat transfer. Long-duration tests revealed a transient evaporation-condensation cycle that temporarily reduced rotor immersion and performance before stabilizing. The generator powered commercial marine sensors for over 6 h without external batteries, demonstrating the viability of compact, passively cooled thermomagnetic systems for autonomous, off-grid marine sensing.

13 HYDRO ENERGY↗

Multiscale Crystalline Structure of Confined Polypeptoid Films: The Effect of Alkyl Side Chain Branching

Here we report the effect of alkyl side chain branching on melt-recrystallization of nanoconfined polypeptoid films using poly(N-octyl glycine) (PNOG) and poly(N-2-ethyl-1-hexyl glycine) (PNEHG) as model systems. Upon cooling from the isotropic melt, confined PNOG molecules recrystallize into a near-perfect orthorhombic crystal structure with the board-like molecules stacked face-to-face in the substrate-parallel direction, resulting in long-range ordered wormlike lamellae that occupy the entire film. By contrast, rod-like PNEHG molecules bearing branched N-2-ethyl-1-hexyl side chains stack into a columnar hexagonal mesophase with their backbones oriented parallel to the substrates, forming micron-sized sheaf-like superstructures under confinement, exposing large areas of empty spaces in the film. These findings highlight the effect of alkyl side chain branching on the packing motif and multiscale crystalline structure of polypeptoids under a nanoconfined geometry.

36 MATERIALS SCIENCE↗