At least 505 records · Page 28

The 9th Aerospace Mechanisms Symposium

Papers are presented dealing with performance and development of various spacecraft components, mechanical devices, and subsystems. Topics discussed include: manipulator arms, the Skylab Parasol, cooling system performance, extendable booms, magnetically suspended reaction wheels, the Skylab Trash Airlock, magnetometers, actuators, life support systems, and technology transfer.

Source record↗

Console test report for shuttle task 501 shuttle carrier aircraft transceiver console (SED 36115353-301)

Performance tests completed on the Space Shuttle Carrier Aircraft (SCA) transceiver console, verifying its design objectives, were described. These tests included: (1) check of power supply voltages for correct output voltage and energization at the proper point in the turn on sequence, (2) check of cooling system (LRU blower, overload sensors and circuitry, and thermocouple probe), (3) check of control circuits logic, including the provisions for remote control and display, (4) check of the LRU connector for presence of correct voltages and absence of incorrect voltages under both energized and deenergized conditions, and (5) check of the AGC and power output monitor circuits.

Lane, J. H.↗

Thermal testing of a high powered communications satellite

Thermal Vacuum and Thermal Balance tests were successfully conducted on the high power Communications Technology Satellite (CTS). The mission required testing for two distinct thermal environments; spin stabilized at 60 rpm with a minimum of 55 watts of dissipated power, and three-axis stabilized with as much as a tenfold increase of dissipation. The test program verified the adequacy of the spacecraft thermal design and demonstrated functional operation over a wide temperature range for all of the components. Special test hardware incorporating water-cooling systems was required to accomodate the heatpipes and high RF output power. Objectives, test facilities, special hardware, spacecraft configurations, and results of the tests are discussed. Preliminary flight results and conclusions drawn from the test experience are reported.

Caswell, R. D.↗

Development and test of two flexible cryogenic heat pipes

Results are presented for a comprehensive test program directed toward determining the physical and thermal performance of two flexible cryogenic heat pipes that can provide a highly efficient thermal link between a detector and a space radiator or other cooling system in spacecraft applications. A 100-200 K high-power heat pipe is tested with methane at 100-140 K while a 15-100 K low-temperature pipe is designed for operation with nitrogen and oxygen and is optimized for oxygen in the range 75-90 K. Parametric performance and design tradeoff studies are carried out to determine the optimum geometry and materials for the container and wicking systems. A spiral multiwrap wick in conjunction with braided bellows appears to be a workable solution to the problem of developing highly flexible heat transport devices for cryogenic applications.

Wright, J. P.↗

Public policy for solar heating and cooling

Recent analyses indicated that solar heating and cooling systems for residential buildings are nearly economically competitive with conventional fossil fuel or electric systems, the former having higher initial cost but a lower operating cost than the latter. The paper examines obstacles to the widespread acceptance and use of solar space conditioning systems and explores some general policies which could help to overcome them. The discussion covers such institutional barriers limiting the adoption of solar technologies as existing building codes, financing constraints, and organizational structure of the building industry. The potential impact of financial incentives is analyzed. It is noted that a tax incentive of 25% could speed the use of solar energy by 7 to 8 years and produce an 8% reduction in fossil fuel use by 1990. A preliminary incentive package which could be helpful in promoting solar energy both at federal and state levels is proposed, and the necessary incentive level is analysed.

Hirshberg, A. S.↗

Cooling vest

Inexpensive vest of heat-sealable urethane material, when strapped to person's body, presents significant uncomplicated cooling system for environments where heavy accumulation of metabolic heat exists. Garment is applicable to occupations where physical exertion is required under heavy protective clothing.

Kosmo, J.↗

Emissions and Total Energy Consumption of a Multicylinder Piston Engine Running on Gasoline and a Hydrogen-gasoline Mixture

A multicylinder reciprocating engine was used to extend the efficient lean operating range of gasoline by adding hydrogen. Both bottled hydrogen and hydrogen produced by a research methanol steam reformer were used. These results were compared with results for all gasoline. A high-compression-ratio, displacement production engine was used. Apparent flame speed was used to describe the differences in emissions and performance. Therefore, engine emissions and performance, including apparent flame speed and energy lost to the cooling system and the exhaust gas, were measured over a range of equivalence ratios for each fuel. All emission levels decreased at the leaner conditions. Adding hydrogen significantly increased flame speed over all equivalence ratios.

Cassidy, J. F.↗

Compact pulsed laser having improved heat conductance

A highly efficient, compact pulsed laser having high energy to weight and volume ratios is provided. The laser utilizes a cavity reflector that operates as a heat sink and is essentially characterized by having a high heat conductivity, by being a good electrical insulator and by being substantially immune to the deleterious effects of ultra-violet radiation. Manual portability is accomplished by eliminating entirely any need for a conventional circulating fluid cooling system.

Yang, L. C.↗

ERDA/NASA-MSFC solar heating and cooling development and demonstration program

The role of the Manned Space Flight Center (MSFC) in the National Solar Heating and Cooling program is evaluated. The responsibilities of the MSFC within this program are (1) to manage the development and testing of solar heating and cooling systems leading to marketable products, (2) to develop data acquisition equipment supporting a national data program, and (3) to manage and collect data from commercial demonstration sites. MSFC test facilities and demonstration sites are described.

Price, J. M.↗

Corrosion inhibitors for solar-heating and cooling

Report describes results of tests conducted to evaluate abilities of 12 candidate corrosion inhibitors to protect aluminum, steel, copper, or stainless steel at typical conditions encountered in solar heating and cooling systems. Inhibitors are based on sodium salts including nitrates, borates, silicates, and phosphates.

Humphries, T. S.↗

Building application of solar energy. Study no. 4: Scenarios for the utilization of solar energy in southern California buildings, change 1

Plausible future market scenarios for solar heating and cooling systems into buildings in the area served by the Southern California Edison Company. A range of plausible estimates for the number of solar systems which might be installed and the electrical energy which might be displaced by energy from these systems are provided. The effect on peak electrical load was not explicitly calculated but preliminary conclusions concerning peak load can be inferred from the estimates presented. Two markets are investigated: the single family market and the large power commercial market.

Davis, E. S.↗

Solar Control design package

Information used in the evaluation of design of Solar Control's solar heating and cooling system controller and the Solarstat is given. Some of the information includes system performance specifications, design data brochures, and detailed design drawings.

Source record↗

Development of nonmetallic solar collector and solar-powered pump

Design and building of two unique components for solar heating (1. flatplate solar collector using no metal components, and 2. solar powered pump for heating and cooling systems are outlined in report. Report also discusses hardware, deliverable end items, problems encountered during fabrication and testing, and performance certification.

Parker, J. C.↗

Water-cooled insulated steam-injection wells

Water is used as insulated coolant and heat-transfer medium for steam-injection oil wells. Approach is somewhat analogous to cooling system in liquid-propellant rocket. In addition to trapping and delivering heat to steam-injection point, water will also keep casing cooler, preventing or reducing casing failures caused by thermal stresses.

Back, L. H.↗

Development of flame resistant treatment for nomex fibrous structures

Technology which renders aramid fibrous structures flame resistant through chemical modification was developed. The project scaled up flame resistant treatment from laboratory fabric swatches of a few inches to efficiently producing ten yards of commercial width (41 inches) aromatic polyamide. The radiation intensity problem of the processor was resolved. Further improvement of the processor cooling system was recommended for two reasons: (1) To advance current technology of flame proofing Nomex fabric to higher oxygen enriched atmospheres; and (2) To adapt the processor for direct applicability to low cost commercial fabrics.

Toy, M. S.↗

Development, testing, and certification of the Northrup, Inc., ML series concentrating solar collector model NSC-01-0732

A summary is presented of the additional development work on the existing ML Series concentrating solar collector for use with solar heating and cooling systems. The report discusses the intended use of the final report, describes the development hardware, lists deliverable end items, deals with problems encountered during fabrication and testing, and includes certification statements of performance. This report shows that the products developed are marketable and suitable for public use.

Parker, J. C.↗

Review and status of liquid-cooling technology for gas turbines

A review was conducted of liquid-cooled turbine technology. Selected liquid-cooled systems and methods are presented along with an assessment of the current technology status and requirements. A comprehensive bibliography is presented.