Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contact pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Gage provides audible signal to facilitate checkout of connector pins

Commercial push gage has been modified to enable rapid, accurate testing of paddle pins in distributors, bullet pins and patch boards. The purpose of the gage is to ensure that the pins will not break electrical contact when they are subjected to a minimum, preset pressure.

Northern, B. J.↗

Southwest Research Institute assistance to NASA in biomedical areas of the technology

Significant applications of aerospace technology were achieved. These applications include: a miniaturized, noninvasive system to telemeter electrocardiographic signals of heart transplant patients during their recuperative period as graded situations are introduced; and economical vital signs monitor for use in nursing homes and rehabilitation hospitals to indicate the onset of respiratory arrest; an implantable telemetry system to indicate the onset of the rejection phenomenon in animals undergoing cardiac transplants; an exceptionally accurate current proportional temperature controller for pollution studies; an automatic, atraumatic blood pressure measurement device; materials for protecting burned areas in contact with joint bender splints; a detector to signal the passage of animals by a given point during ecology studies; and special cushioning for use with below-knee amputees to protect the integrity of the skin at the stump/prosthesis interface.

Culclasure, D. F.↗

Laser-Scan Ultrasonic/Thermographic Inspection System

Laser ultrasonic/thermographic inspection system is conceptual instrument used in nondestructive inspection of large areas of structures for subsurface defects. For example, operated in field to examine aircraft and pressure vessels for hidden cracks. System would not require contact with inspected structure or use of ultrasonic-coupling medium. Instrument obtains data in ultrasonic and thermographic C-scans over structural surfaces with contours characterized by surface normal vectors varying by angles as large as 45 degrees.

Bar-Cohen, Yoseph↗

Nd:YAG Laser-Based Dual-Line Detection Rayleigh Scattering and Current Efforts on UV, Filtered Rayleigh Scattering

Ongoing research in Rayleigh scattering diagnostics for variable density low speed flow applications and for supersonic flow measurements are described. During the past several years, the focus has been on the development and use of a Nd:YAG-based Rayleigh scattering system with improved signal-to-noise characteristics and with applicability to complex, confined flows. This activity serves other research projects in the Aerodynamics Laboratory which require the non-contact, accurate, time-frozen measurement of gas density, pressure, and temperature (each separately), in a fairly wide dynamic range of each parameter. Recently, with the acquisition of a new seed-injected Nd:YAG laser, effort also has been directed to the development of a high-speed velocity probe based on a spectrally resolved Rayleigh scattering technique.

Otugen, M. Volkan↗

Balanced Flow Meters without Moving Parts

Balanced flow meters are recent additions to an established class of simple, rugged flow meters that contain no moving parts in contact with flow and are based on measurement of pressure drops across objects placed in flow paths. These flow meters are highly accurate, minimally intrusive, easily manufacturable, and reliable. A balanced flow meter can be easily mounted in a flow path by bolting it between conventional pipe flanges. A balanced flow meter can be used to measure the flow of any of a variety of liquids or gases, provided that it has been properly calibrated. Relative to the standard orifice-plate flow meter, the balanced flow meter introduces less turbulence and two times less permanent pressure loss and is therefore capable of offering 10 times greater accuracy and repeatability with less dissipation of energy. A secondary benefit of the reduction of turbulence is the reduction of vibration and up to 15 times less acoustic noise generation. Both the balanced flow meter and the standard orifice-plate flow meter are basically disks that contain holes and are instrumented with pressure transducers on their upstream and downstream faces. The most obvious difference between them is that the standard orifice plate contains a single, central hole while the balanced flow meter contains multiple holes. The term 'balanced' signifies that in designing the meter, the sizes and locations of the holes are determined in an optimization procedure that involves balancing of numerous factors, including volumetric flow, mass flow, dynamic pressure, kinetic energy, all in an effort to minimize such undesired effects as turbulence, pressure loss, dissipation of kinetic energy, and non-repeatability and nonlinearity of response over the anticipated range of flow conditions. Due to proper balancing of these factors, recent testing demonstrated that the balanced flow-meter performance was similar to a Venturi tube in both accuracy and pressure recovery, but featured reduced cost and pipe-length requirements.

Kelley, Anthony R.↗

Influence of Containment on Defects in GeSi Crystals

Crystals grown without being in contact with a container have superior quality to otherwise similar crystals grown in direct contact with a container, especially with respect to impurity incorporation, formation of dislocations, and residual stress in crystals. "Detached" or "dewetted" Bridgman growth is similar to regular Bridgman growth in that most of the melt is in contact with the crucible wall, but the crystal is separated from the wall by a small gap, typically of the order of 10(exp -5) m. A small meniscus bridges the gap between the top of the crystal and the wall. Key parameters involved in achieving detached growth are the contact angle between the melt and crucible and the pressure differential across the meniscus. Sessile drop measurements were used to determine the wetting angles of Ge(sub 1-x)Si(sub x) melts on a variety of substrates and found that the highest wetting angles were achieved with pyrolitic boron nitride (pBN). GeSi crystals have been repeatedly grown detached in pBN crucibles but only occasionally in crucibles with lower wetting angles. Experiments have been conducted to assess the effect of pressure differential across the meniscus in sealed crucibles. This was done by adjusting the temperature profile after partial melting of the starting material. In a separate set of experiments, the pressure was controlled by connecting the volume below the meniscus to a regulated gas supply. The experiments were in agreement with calculations which predicted that stable detachment will only occur in crucibles with a low wetting angle over a relatively narrow range of pressure differential. Detached-grown crystals exhibited superior structural quality as evidenced by measurements of etch pit density, synchrotron white beam X-ray topography and double axis X-ray diffraction.

Volz, M. P.↗

Non-Contacting Finger Seals Static Performance Test Results at Ambient and High Temperatures

The non-contacting finger seal is an advanced seal concept with potential to reduce specific fuel consumption in gas turbine engines by 2 to 3 percent with little to no wear of the seal or rotor. Static performance tests and bind-up tests of eight different non-contacting finger seal configurations were conducted in air at pressure differentials up to 689.4 kPa and temperatures up to 922 K. Four of the seals tested were designed to have lift pads concentric to a herringbone-grooved rotor which generates hydrodynamic lift when rotating. The remaining seals were tested with a smooth rotor; one seal had a circumferential taper and one had an axial taper on the lift pad inner diameter to create hydrodynamic lift during rotation. The effects of the aft finger axial thickness and of the forward finger inner diameter on leakage performance were investigated as well and compared to analytical predictions.

static tests↗

Non-Contacting Finger Seals Static Performance Test Results at Ambient and High Temperatures

The non-contacting finger seal is an advanced seal concept with potential to reduce specific fuel consumption in gas turbine engines by 2 to 3 with little to no wear of the seal or rotor. Static performance tests and bind-up tests of eight different non-contacting finger seal configurations were conducted in air at pressure differentials up to 689.4 kPa and temperatures up to 922 K. Four of the seals tested were designed to have lift pads concentric to a herringbone-grooved rotor which generates hydrodynamic lift when rotating. The remaining seals were tested with a smooth rotor; one seal had a circumferential taper and one had an axial taper on the lift pad inner diameter to create hydrodynamic lift during rotation. The effects of the aft finger axial thickness and of the forward finger inner diameter on leakage performance were investigated as well and compared to analytical predictions.

rotors↗

Onset of cavitation and vapor bubble development over hydrophilic and hydrophobic surfaces

Cavitation, the formation of vapor bubbles as the liquid pressure is reduced below the saturated vapor pressure, often requires a substantial negative relative pressure in a pure liquid. Classical nucleation theory (CNT) provides an estimate for the rate of cavitation but there is often a disconnect between the predictions at the molecular scale compared to observations at the macroscale. We report on mesoscale simulations of cavitation based on many-body dissipative particle dynamics (mDPD), a coarse-grained molecular dynamics (MD), which bridges the two scales. A liquid layer is confined between smooth planar walls at a constant temperature, while the pressure is reduced slowly by expanding the wall-bounded domain. The wetting properties of the liquid are determined by the parameters of the interaction potentials. With hydrophilic walls, homogeneous nucleation is observed in the liquid bulk. As a bubble forms and grows, it creates a strong pressure pulse and oscillations that cause other bubbles that may have formed slightly later to collapse. For a nearly neutral wall with a contact angle close to 90 ° , heterogeneous nucleation occurs at the walls at a smaller negative pressure and generates weaker pressure oscillations. With hydrophobic walls or seed particles, heterogeneous nucleation readily occurs, where fluctuations and the merger of transient surface bubbles are significant.

Science & Technology - Other Topics↗

Development of new materials for turbopump bearings

The life requirement for the angular contact ball bearings in the Space Shuttle Main Engine (SSME) high pressure oxygen turbopump (HPOTP) is 7.5 hours. In actual operation, significantly shorter service life was experienced. The objective is to identify bearing materials and/or materials processing techniques offering signficant potential for extending HPOTP bearing performance life. Interactive thermomechanical analysis of the HPOTP bearing-shaft system was performed with the SHABERTH computer program. Bearing fatigue life, ball-race contact stress, heat generation rate, bulk ring temperatures and circumferential stress in the inner rings were quantified as functions of radial load, thrust load and ball-race contact friction. Criteria established from the output of this analysis are being used for material candidate selection.

Maurer, R. E.↗

Ultrasonic level sensors for liquids under high pressure

An ultrasonic level sensor of novel design continuously measures the level of a liquid subjected to a high pressure (up to about 40 MPa), as is sometimes required for the effective transfer of the liquid. The sensor operates as a composite resonator fabricated from a standard high-pressure plug. A flat-bottom hole is machined into the plug along its center line. An ultrasonic transducer is bonded rigidly to the interior surface of the bottom wall, while the exterior surface is in contact with the liquid. Although the bottom wall is designed to satisfy the pressure code, it is still sufficiently thin to permit ready excitation of the axisymmetric plate modes of vibration. The liquid level is measured by a conventional pulse-echo technique. A prototype sensor was tested successfully in a 2300-l water vessel at pressures up to about 37 MPa. A spectral analysis of the transmitted pulse reveals that the flexural, extensional, thickness-shear, and radial plate modes are excited into vibration, but none of these appears to be significantly affected by the pressurization of the liquid.

Zuckerwar, A. J.↗

Scuffing Characteristics of High-Load Rolling/Sliding Contacts Operating in Liquid Oxygen: Effects of Materials and Surface Roughness

This research reports on an experimental study of the effects of materials and surface roughness on the scuffing characteristics of rolling/sliding contacts cooled and lubricated with liquid oxygen. Experiments were carried out under heavy loading with a Hertzian pressure in the range of 2.0 GPa to 3.0 GPa and with a high rolling velocity of up to 48 m/s. For contacts between AISI 440 C stainless-steel elements, the results showed that the scuffing behavior of the system was fairly consistent under a wide range of rolling velocity. Scuffing commenced at a small slide-to-roll ratio of around 0.02, and the scuffing behavior of the contact was not sensitive to surface roughness for the test-sample RMS roughness ranging from 0.02 microns to 0.10 microns. For contacts between 440 C and Si3N4 elements, on the other hand, the scuffing behavior of the system was not very consistent and somewhat unpredictable. The results were sensitive to surface roughness particularly that of the Si3N4 test sample. With well polished test samples, consistent results were obtained; the level of traction was lower than that with a 440 C toroid and scuffing did not take place up to a slide-to-roll ratio of near 0.03. The results strongly suggest that significant hydrodynamic effect can be generated by liquid oxygen under heavy loading and high velocity conditions. The results also suggest that the hydrodynamic action is likely generated by the conventional viscous mechanism as it can be largely destroyed by a narrow circumferential surface scratch running through the central region of the contact.

Chang, L.↗

Residual Gas Effects on Detached Solidification in Microgravity

Many microgravity directional solidification experiments yielded ingots with portions that grew without contacting the ampoule wall, leading to greatly improved crystallographic perfection. Our long-term goal is to make such detached solidification reproducible, which requires a full understanding of the mechanisms underlying it. Our Moving Meniscus Model of steady-state detachment predicts that it depends strongly on the surface tension of the melt and the advancing contact angle with the ampoule wall. Detached solidification is more likely when the contact angle for the melt on the ampoule wall is high, i.e. non-wetting. It has been claimed that impurities increase the contact angle. The objective of the current project is to determine the influence of residual gases on the surface tension and contact angle of molten semiconductors on typical ampoule materials. We are focusing on determining the influence of oxygen on the contact angle of molten InSb on clean silica ('quartz'), including the advancing and retreating contact angles in addition to the usual equilibrium contact angle. We have created a gas flow system that allows us to control the oxygen partial pressure over a sessile drop of InSb on a horizontal quartz surface. The cell is slowly tilted while videotaping to reveal the contact angles on the two sides of the drop just prior to it rolling down the surface. Thus far, we have learned the following: (1) Molten InSb readily forms an oxide layer in the presence of the trace amounts of oxygen found in high purity argon; (2) This oxide contains a substantial amount of Ga, which presumably is a trace contaminant that is not detectable in the starting material; (3) The addition of 10% hydrogen to the argon gas is sufficient to reduce the oxide and produce a clean drop; (4) An infrared filter must precede the video camera in order to produce a sharp image of the drop for later image analysis; (5) Tilting the surface on which the drop rests causes the two sides of the drop to display different contact angles, reflecting contact line sticking; (6) Vibration strongly accelerates the approach of the drop to its final shape on a horizontal surface by helping to overcome sticking of the contact line; (7) Oscillation of the drop surface due to vibration appears to increase as the surface is inclined from horizontal. Presumably, the angle at which the drop rolls down the surface is also reduced by vibration. This observation is particularly significant, as the meniscus must move along the ampoule wall during detached solidification.

Regel, Liya L.↗

Transient effect of lubricant on elastohydro-dynamic film thickness

The inlet solution of the elastohydrodynamic lubricated rolling contact problem was obtained by considering lubricants with transient viscosity. The effect of the viscoelastic retardation time of the lubricant on the center film thickness was investigated. The effect of transient viscosity in response to a sudden pressure was found to be insignificant in determining the film thickness in elastohydrodynamic contacts.

Wang, K. L.↗

Reliable operation of Cr 2 O 3 :Mg/ $β$-Ga 2 O 3 p–n heterojunction diodes at 600 °C

Beta gallium oxide (β-Ga 2 O 3 )-based semiconductor heterojunctions have recently demonstrated improved performance at high voltages and elevated temperatures and are, thus, promising for applications in power electronic devices and harsh environment sensors. However, the long-term reliability of these ultra-wideband gap (UWBG) semiconductor devices remains barely addressed and may be strongly influenced by chemical reactions at the p–n heterojunction interface. Here, we experimentally demonstrate operation and evaluate the reliability of Cr 2 O 3 :Mg/β-Ga 2 O 3 p–n heterojunction diodes during extended operation at 600 °C, as well as after 30 repeated cycles between 25 and 550 °C. The calculated pO 2 -temperature phase stability diagram of the Ga-Cr-O material system predicts that Ga 2 O 3 and Cr 2 O 3 should remain thermodynamically stable in contact with each other over a wide range of oxygen pressures and operating temperatures. The fabricated Cr 2 O 3 :Mg/β-Ga 2 O 3 p–n heterojunction diodes show room-temperature on/off ratios >104 at ±5 V and a breakdown voltage (V Br ) of -390 V. The leakage current increases with increasing temperature up to 600 °C, which is attributed to Poole–Frenkel emission with a trap barrier height of 0.19 eV. Over the course of a 140-h thermal soak at 600 °C, both the device turn-on voltage and on-state resistance increase from 1.08 V and 5.34 mΩ cm 2 to 1.59 V and 7.1 mΩ cm 2 , respectively. This increase is attributed to the accumulation of Mg and MgO at the Cr 2 O 3 /Ga 2 O 3 interface as observed from the time-of-flight secondary ion mass spectrometry analysis. These findings inform future design strategies of UWBG semiconductor devices for harsh environment operation and underscore the need for further reliability assessments for β-Ga 2 O 3 -based devices.

36 MATERIALS SCIENCE↗

Piezoviscous effects in nonconformal contacts lubricated hydrodynamically

The analysis is concerned with the piezoviscous-rigid regime of lubrication for the general case of elliptical contacts. In this regime several formulas of the lubricant film thickness have been proposed by Hamrock and Dowson, by Dowson et al., and more recently by Houpert. However, either they do not include the load parameter W, which has a strong effect on film thickness, or they overestimate the film thickness by using the Barus formula for pressure-viscosity characteristics. The Roelands formula was used for the pressure-viscosity relationship. The effects of the dimensionless load, speed, and materials parameters, the radius ratio, and the lubricant entrainment direction were investigated. The dimensionless load parameter was varied over a range of one order of magnitude. The dimensionless speed parameter was varied by 5.6 times the lowest value. Conditions corresponding to the use of solid materials of steel, bronze, and silicon nitride and lubricants of paraffinic and naphthenic mineral oil were considered in obtaining the exponent in the dimensionless materials parameter. The radius ratio was varied from 0.2 to 64 (a configuration approaching a line contact). Forty-one cases were used in obtaining a minimum film thickness formula. Contour plots indicate in detail the pressure developed between the contacting solids.

Jeng, Y. R.↗

Piezoviscous effects in nonconformal contacts lubricated hydrodynamically

The analysis is concerned with the piezoviscous-rigid regime of lubrication for the general case of elliptical contacts. In this regime several formulas of the lubricant film thickness have been proposed by Hamrock and Dowson, by Dowson et al., and more recently by Houpert. However, either they do not include the load parameter W, which has a strong effect on film thickness, or they overestimate the film thickness by using the Barus formula for pressure-viscosity characteristics. The Roelands formula was used for the pressure-viscosity relationship. The effects of the dimensionless load, speed, and materials parameters, the radius ratio, and the lubricant entrainment direction were investigated. The dimensionless load parameter was varied over a range of one order of magnitude. The dimensionless speed parameter was varied by 5.6 times the lowest value. Conditions corresponding to the use of solid materials of steel, bronze, and silicon nitride and lubricants of paraffinic and naphthenic mineral oil were considered in obtaining the exponent in the dimensionless materials parameter. The radius ratio was varied from 0.2 to 64 (a configuration approaching a line contact). Forty-one cases were used in obtaining a minimum film thickness formula. Contour plots indicate in detail the pressure developed between the contacting solids.

Jeng, Yeau-Ren↗

The Influence of Dynamic Contact Angle on Wetting Dynamics

When surface tension forces dominate, and regardless of whether the situation is static or dynamic, the contact angle (the angle the interface between two immiscible fluids makes when it contacts a solid) is the key parameter that determines the shape of a fluid-fluid interface. The static contact angle is easy to measure and implement in models predicting static capillary surface shapes and such associated quantities as pressure drops. By contrast, when the interface moves relative to the solid (as in dynamic wetting processes) the dynamic contact angle is not identified unambiguously because it depends on the geometry of the system Consequently, its determination becomes problematic and measurements in one geometry cannot be applied in another for prediction purposes. However, knowing how to measure and use the dynamic contact angle is crucial to determine such dynamics as a microsystem throughput reliably. In this talk we will present experimental and analytical efforts aimed at resolving modeling issues present in dynamic wetting. We will review experiments that show the inadequacy of the usual hydrodynamic model when a fluid-fluid meniscus moves over a solid surface such as the wall of a small tube or duct. We will then present analytical results that show how to parametrize these problems in a predictive manner. We will illustrate these ideas by showing how to implement the method in numerical fluid mechanical calculations.

Rame, Enrique↗