Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “code portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Feasibility study for measurement of insulation compaction in the cryogenic rocket fuel storage tanks at Kennedy Space Center by fast/thermal neutron techniques

The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Some of the perlite may have compacted over time, compromising the thermal performance and also the structural integrity of the tanks. Neutrons can readily penetrate through the 1.75 cm outer steel shell and through the entire 120 cm thick perlite zone. Neutrons interactions with materials produce characteristic gamma rays which are then detected. In compacted perlite the count rates in the individual peaks in the gamma ray spectrum will increase. Portable neutron generators can produce neutron simultaneous fluxes in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scattering which is sensitive to Si, Al, Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA), which is sensitive to Si, Al, Na, K and H among others. The results of computer simulations using the software MCNP and measurements on a test article suggest that the most promising approach would be to operate the system in time-of-flight mode by pulsing the neutron generator and observing the subsequent die away curve in the PGNA signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computational Modeling, Simulation and Analysis of the RPI Walthousen Reactor Critical Facility (RCF)

The Walthousen Reactor Critical Facility (RCF), located in Schenectady, New York, is currently owned and operated by Rensselaer Polytechnic Institute (RPI). The facility was originally constructed by the American Locomotive Company (ALCO) for the research and development of small, portable reactors. Originally designed for highly-enriched uranium fuel, the prototype reactor first came online in August 26, 1956, and was transferred to RPI ownership in 1963. Several changes to the reactor's design and operation have been made, the most notable of which was the conversion from high-enriched uranium to low-enriched uranium fuel. The RCF is an open-pool critical assembly that operates at a low power with a license limit of less than 100 watts. This low operating power permits a much greater flexibility in configuration and operation as compared to other research reactors. Because of this, experiments may be designed that would be unfeasible for research reactors that operate at much higher powers. The RCF's functional capabilities provide opportunities to perform several reactor experiments and measurements, such as: core criticality experiments, differential and integral rod worth measurements, moderator temperature coefficient of reactivity calculations, critical rod height and critical water height measurements, etc.. These experiments are regularly performed in conjunction with RPI course-work education and Senior Reactor Operator (SRO) training. The unique capabilities and experiments that may be performed in the RCF are particularly useful for validating certain aspects of computational analysis codes. A computational model of the RCF reactor has been previously generated and validated using the Monte Carlo N-Particle (MCNP) code. For the purpose of future experiments, this model is also being adapted for use with the SHARP Toolset, which includes the PROTEUS neutronics code, the Nek5000 fluid dynamics code, and the Diablo structural mechanics code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

WORM (Write One, Read Many)

WORM (Write One, Run Many) is an easy to use, cross platform, embedded and extensible, functional programming language designed to facilitate the creation of input-decks for computer codes that use standard ASCII text files for input. WORM makes it easy to create generic (yet, complex and powerful) reusable models. Additionally its nature allows for complex calculations and routines to be coded once and easily reused, further simplifying the creation of input decks. WORM (Write One, Run Many) is a powerful and versatile tool designed to improve the efficiency of today’s criticality safety analyst by allowing: + input decks for parametric studies to be created quickly and easily, + calculations and variables to be imbedded into any input deck, thus allowing for meaningful parameter specifications, + problems to be specified using any combination of units, and + complex mathematically defined models to be created. A very simple syntax is employed, and therefore the WORM is easy to learn. A WORM model is essentially a standard input deck with some of its numerical values replaced by WORM code. WORM code may include and evaluate the following mathematical operators and functions: addition, subtraction, multiplication, division, exponentiation, modulus, sine, cosine, tangent, arcsine, arccosine, arctangent, the natural logarithm, logarithm base 10, integer truncation, absolute value, and random number. Several common constants, e.g., pi, e, and Avogadros’s Number (both as 6.022e23 and 0.6022), are predefined in WORM. Additionally, many unit conversion factors are also predefined: millimeters, meters, inches, feet, yards, and mils to centimeters; kilograms, pounds, and ounces to grams; liters, milliliters, gallons, and fluid ounces to cubic centimeters; and angular degrees to radians. For parametric studies, WORM supports various shorthand list specifications: the explicit step size, linear interpolation, and logarithmic interpolation. The list notation sequentially assigns multiple values to a name. WORM creates an input deck for each value of the name. If multiple lists are used, WORM steps through each list individually, i.e., WORM creates input decks corresponding to each and every permutation of the list values. Additionally, a library of standard material definitions and Perl subroutines are included. Any one of these files can be incorporated into the subject model with a simple WORM read command. WORM is completely written in Perl, the Practical Extraction and Reporting Language. Perl is one of the most portable programming languages available today. As such, the WORM works on practically any computer platform.

Sartor, Raymond↗

Experiences with SYCL on AMD GPUs with Kokkos

With the recent diversification of the hardware landscape in the high-performance computing (HPC) community, performance-portability solutions are becoming more and more important. One of the most popular choices is Kokkos, which recently became a Linux Foundation project. Most of its development is supported by the US Department of Energy and the French Alternative Energies and Atomic Energy Commission. Kokkos is implemented as a C++ library with multiple backends to support CPUs as well as various GPU architectures. These backends include OpenMP, CUDA, HIP, and also SCYL. This approach enables users to leverage the preferred vendor toolchain for the respective platform (e.g. CUDA, ROCm, OneAPI). The SYCL backend is used to target Intel GPUs, in particular to support the Aurora exascale supercomputer. However, SYCL itself also offers a large degree of portability, and in fact Kokkos’ CI for SYCL has been running on NVIDIA hardware due to a lack of access to Intel GPUs. In this report, we describe our experience with using Kokkos SYCL backend on AMD GPUs targeting the Frontier supercomputer at Oak Ridge National Laboratory. The two major SYCL implementations are DPC++ and AdaptiveCpp. While the Kokkos SYCL backend has been implemented using the former, the latter was the first implementation to target AMD GPUs. We will discuss the experience with both of these SYCL implementations in terms of functionality and performance. Using Kokkos to evaluate SYCL toolchains has a number of benefits. Kokkos’ use of SYCL is fairly complex, exercising features such as graphs, relocatable device functions, atomics – including for non-arithmetic types, as well as pinned and page migratable memory allocations. Kokkos also needs to implement capabilities such as Kokkos’ hierarchical parallelism that are not a straight-forward mapping to SYCL capabilities. Furthermore, a large number of libraries and applications that represent diverse use cases are implemented in Kokkos, providing readily available test cases for a toolchain evaluation. Preliminary results show that support for AMD GPUs in DPC++ is much less mature than for NVIDIA GPUs or Intel GPUs. While the situation has improved significantly over the last year, we still encounter many runtime failures, dispatching problems, and code generation issues. With AdaptiveCpp the challenges arise even earlier in the evaluation process. Since Kokkos’ SYCL implementation is largely focused on supporting Intel GPUs, we opted to leverage SYCL extensions which are available in DPC++ but not in AdaptiveCpp. Furthermore, AdaptiveCpp appears to be less conformant with the SYCL2020 standard which Kokkos relies on. In some cases, we are able to work around the lack of feature support, in other cases we have to disable certain Kokkos capabilities to evaluate the toolchain. Our evaluation will leverage Kokkos’ unit tests to establish basic functionality and feature completeness. We then use simple benchmarks for components of a CG implementation as a measure of usability and performance of the SYCL toolchains.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-27: A Tool for Routine Quality Assurance of Radiotherapy Dose Calculation Software

Purpose: Dose calculation software is thoroughly evaluated when it is commissioned; however, evaluation of periodic software updates is typically limited in scope due to staffing constraints and the need to quickly return the treatment planning system to clinical service. We developed a tool for quickly and comprehensively testing and documenting dose calculation software against measured data. Methods: A tool was developed using MatLab (The MathWorks, Natick, MA) for evaluation of dose calculation algorithms against measured data. Inputs to the tool are measured data, reference DICOM RT PLAN files describing the measurements, and dose calculations in DICOM format. The tool consists of a collection of extensible modules that can perform analysis of point dose, depth dose curves, and profiles using dose difference, distance-to-agreement, and the gamma-index. Each module generates a report subsection that is incorporated into a master template, which is converted to final form in portable document format (PDF). Results: After each change to the treatment planning system, a report can be generated in approximately 90 minutes. The tool has been in use for more than 5 years, spanning 5 versions of the eMC and 4 versions of the AAA. We have detected changes to the algorithms that affected clinical practice once during this period. Conclusion: Our tool provides an efficient method for quality assurance of dose calculation software, providing a complete set of tests for an update. Future work includes the addition of plan level tests, allowing incorporation of, for example, the TG-119 test suite for IMRT, and integration with the treatment planning system via an application programming interface. Integration with the planning system will permit fully-automated testing and reporting at scheduled intervals.

07 ISOTOPE AND RADIATION SOURCES↗

DECOMMISSIONING AND ENVRIONMENTAL CLEANUP OF SMALL ARMS TRAINING FACILITY

USDOE performed a (CERCLA) non-time critical removal (NTCR) action at the Small Arms Training Area (SATA) Site Evaluation Area (SEA) located at the Savannah River Site (SRS), in Aiken, South Carolina. From 1951 to May 2010, the SATA was used as a small weapons practice and qualifying firing range. The SATA consisted of 870.1 ha (2,150 ac) of woodlands and open field, of which approximately 2.9 ha (7.3 ac) were used as a firing range. The SATA facility was comprised of three small arms ranges (one static and two interactive), storage buildings for supplies, a weapons cleaning building, and a control building. Additionally, a 113- m (370-ft) long earthen berm was used as a target backstop during live-fire exercises. The berm soils accumulated a large amount of spent lead bullets in the berm face during the facilities 59- years of operation. The accumulation of lead was such that soil concentrations exceeded the U.S. Environmental Protection Agency (USEPA) residential and industrial worker regional screening levels (RSLs). The RSL threshold values are based on standardized exposure scenarios that estimate contaminant concentrations in soil that the USEPA considers protective of humans over a lifetime. For the SATA facility, lead was present in soil at concentrations that exceed both the current residential (400 mg/kg) and industrial (800 mg/kg) RSLs. In addition, the concentration of lead in the soil exceeded the Toxicity Characteristic Leaching Procedure (TCLP) (40 Code of Federal Regulations [CFR] 261.24) regulatory limit. The TCLP analysis simulates landfill conditions and is designed to determine the mobility of contaminants in waste. In addition, a principal threat source material (PTSM) evaluation, human health risk assessment (HHRA), and contaminant migration (CM) analysis were conducted to evaluate soil contamination at the SATA SEA. This evaluation determined that there were no contaminants present that constitute PTSM and the CM analysis revealed that no constituents posed a migration risk to groundwater. The NTCR action involved removal of approximately 12,092 m3 (15,816 yd3) of spent bullets and lead-impacted soil and off-site disposal. The removal action included soils from the berm area, a fill area that received scraped soils from the berm, and soil from a drainage ditch located on the edge of the berm area. Also included in the removal action was a mixture of soil, concrete, and asphalt from the other three range areas. Under this action, 11,796 m3 (15,429 yd3) of hazardous waste and impacted soil were removed from the SATA and transported to a permitted hazardous waste disposal facility (Lone Mountain Facility in Oklahoma) and 296 m3 (387 yd3) of nonhazardous waste (primarily concrete debris) were removed and transported to a local solid waste landfill for disposal. During the excavation process, the extent was continuously assessed through the use of a hand-held, field-portable X-ray fluorescence unit with results verified using confirmation sampling with certified laboratory analysis. Following the completion of the excavation and confirmation sampling, final contouring, grading, and establishment of vegetative cover was performed to stabilize the affected areas. The NTCR action began on August 17, 2010, and mechanical completion was achieved on April 27, 2011. The selected removal action met the removal action objectives (RAOs), is protective of human health and the environment both in the short- and long-term, was successful in removing potential ecological risks, and is protective of surface water and groundwater. Furthermore, the selected NTCR action met residential cleanup goals and resulted in the release of the SEA from restricted use contributing to the overall footprint reduction at SRS.

54 ENVIRONMENTAL SCIENCES↗

Decommissioning and Environmental Cleanup of a Small Arms Training Facility - 13225

US DOE performed a (CERCLA) non-time critical removal (NTCR) action at the Small Arms Training Area (SATA) Site Evaluation Area (SEA) located at the Savannah River Site (SRS), in Aiken, South Carolina. From 1951 to May 2010, the SATA was used as a small weapons practice and qualifying firing range. The SATA consisted of 870.1 ha (2,150 ac) of woodlands and open field, of which approximately 2.9 ha (7.3 ac) were used as a firing range. The SATA facility was comprised of three small arms ranges (one static and two interactive), storage buildings for supplies, a weapons cleaning building, and a control building. Additionally, a 113- m (370-ft) long earthen berm was used as a target backstop during live-fire exercises. The berm soils accumulated a large amount of spent lead bullets in the berm face during the facilities 59- years of operation. The accumulation of lead was such that soil concentrations exceeded the U.S. Environmental Protection Agency (USEPA) residential and industrial worker regional screening levels (RSLs). The RSL threshold values are based on standardized exposure scenarios that estimate contaminant concentrations in soil that the USEPA considers protective of humans over a lifetime. For the SATA facility, lead was present in soil at concentrations that exceed both the current residential (400 mg/kg) and industrial (800 mg/kg) RSLs. In addition, the concentration of lead in the soil exceeded the Toxicity Characteristic Leaching Procedure (TCLP) (40 Code of Federal Regulations [CFR] 261.24) regulatory limit. The TCLP analysis simulates landfill conditions and is designed to determine the mobility of contaminants in waste. In addition, a principal threat source material (PTSM) evaluation, human health risk assessment (HHRA), and contaminant migration (CM) analysis were conducted to evaluate soil contamination at the SATA SEA. This evaluation determined that there were no contaminants present that constitute PTSM and the CM analysis revealed that no constituents posed a migration risk to groundwater. The NTCR action involved removal of approximately 12,092 m{sup 3} (15,816 yd{sup 3}) of spent bullets and lead-impacted soil and off-site disposal. The removal action included soils from the berm area, a fill area that received scraped soils from the berm, and soil from a drainage ditch located on the edge of the berm area. Also included in the removal action was a mixture of soil, concrete, and asphalt from the other three range areas. Under this action, 11,796 m{sup 3} (15,429 yd{sup 3}) of hazardous waste and impacted soil were removed from the SATA and transported to a permitted hazardous waste disposal facility (Lone Mountain Facility in Oklahoma) and 296 m{sup 3} (387 yd{sup 3}) of nonhazardous waste (primarily concrete debris) were removed and transported to a local solid waste landfill for disposal. During the excavation process, the extent was continuously assessed through the use of a hand-held, field-portable X-ray fluorescence unit with results verified using confirmation sampling with certified laboratory analysis. Following the completion of the excavation and confirmation sampling, final contouring, grading, and establishment of vegetative cover was performed to stabilize the affected areas. The NTCR action began on August 17, 2010, and mechanical completion was achieved on April 27, 2011. The selected removal action met the removal action objectives (RAOs), is protective of human health and the environment both in the short- and long-term, was successful in removing potential ecological risks, and is protective of surface water and groundwater. Furthermore, the selected NTCR action met residential cleanup goals and resulted in the release of the SEA from restricted use contributing to the overall footprint reduction at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LDRD final report on confinement of cluster fusion plasmas with magnetic fields.

Two versions of a current driver for single-turn, single-use 1-cm diameter magnetic field coils have been built and tested at the Sandia National Laboratories for use with cluster fusion experiments at the University of Texas in Austin. These coils are used to provide axial magnetic fields to slow radial loss of electrons from laser-produced deuterium plasmas. Typical peak field strength achievable for the two-capacitor system is 50 T, and 200 T for the ten-capacitor system. Current rise time for both systems is about 1.7 {mu}s, with peak current of 500 kA and 2 MA, respectively. Because the coil must be brought to the laser, the driver needs to be portable and drive currents in vacuum. The drivers are complete but laser-plasma experiments are still in progress. Therefore, in this report, we focus on system design, initial tests, and performance characteristics of the two-capacitor and ten-capacitors systems. The questions of whether a 200 T magnetic field can retard the breakup of a cluster-fusion plasma, and whether this field can enhance neutron production have not yet been answered. However, tools have been developed that will enable producing the magnetic fields needed to answer these questions. These are a two-capacitor, 400-kA system that was delivered to the University of Texas in 2010, and a 2-MA ten-capacitor system delivered this year. The first system allowed initial testing, and the second system will be able to produce the 200 T magnetic fields needed for cluster fusion experiments with a petawatt laser. The prototype 400-kA magnetic field driver system was designed and built to test the design concept for the system, and to verify that a portable driver system could be built that delivers current to a magnetic field coil in vacuum. This system was built copying a design from a fixed-facility, high-field machine at LANL, but made to be portable and to use a Z-machine-like vacuum insulator and vacuum transmission line. This system was sent to the University of Texas in Austin where magnetic fields up to 50 T have been produced in vacuum. Peak charge voltage and current for this system have been 100 kV and 490 kA. It was used this last year to verify injection of deuterium and surrogate clusters into these small, single-turn coils without shorting the coil. Initial test confirmed the need to insulate the inner surface of the coil, which requires that the clusters must be injected through small holes in an insulator. Tests with a low power laser confirmed that it is possible to inject clusters into the magnetic field coils through these holes without destroying the clusters. The university team also learned the necessity of maintaining good vacuum to avoid insulator, transmission line, and coil shorting. A 200-T, 2 MA system was also constructed using the experience from the first design to make the pulsed-power system more robust. This machine is a copy of the prototype design, but with ten 100-kV capacitors versus the two used in the prototype. It has additional inductance in the switch/capacitor unit to avoid breakdown seen in the prototype design. It also has slightly more inductance at the cable connection to the vacuum chamber. With this design we have been able to demonstrate 1 MA current into a 1 cm diameter coil with the vacuum chamber at air pressure. Circuit code simulations, including the additional inductance with the new design, agree well with the measured current at a charge voltage of 40 kV with a short circuit load, and at 50 kV with a coil. The code also predicts that with a charge voltage of 97 kV we will be able to get 2 MA into a 1 cm diameter coil, which will be sufficient for 200 T fields. Smaller diameter or multiple-turn coils will be able to achieve even higher fields, or be able to achieve 200-T fields with lower charge voltage. Work is now proceeding at the university under separate funding to verify operation at the 2-MA level, and to address issues of debris mitigation, measurement of the magnetic field, and operation in vacuum. We anticipate operation at full current with single-turn, magnetic field coils this fall, with 200 T experiments on the Texas Petawatt laser in the spring of 2012.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modal survey test and model correlation of the CASSIOPE spacecraft

A comprehensive modal survey test based on multi-input multi-output experimental modal analysis techniques was conducted on the flight model of the CASSIOPE spacecraft in the final stages of integration, which included all of the payload and bus instruments and electronics boxes. The multiple-input excitation for the spacecraft was generated using two portable electrodynamic modal shakers installed on the top and bottom of the spacecraft to distribute the excitation energy and the response was measured using 81 miniature accelerometers. Advanced modal analysis software was used to extract modal parameters from the measured data and critical modes were compared with predictions from the finite element model. Most modes identified through the experimental data compared favorably with the predictions. Nevertheless, some differences were large enough to require iterative update of the finite element model. The structural dynamics information from the updated finite element model was used to plan the mechanical vibration qualification test and predict the response of the spacecraft to the launch vehicle environmental loads through coupled loads analysis to provide confidence in the structural integrity of the spacecraft design. This paper describes the details of the methodology used to perform the successful experimental modal test to efficiently extract the critical modes of the spacecraft to correlate with the model.

42 ENGINEERING↗

SU-E-T-267: Development of the Compact Graphite Calorimetry System for the High Energy Photon Beam

Purpose: Graphite calorimeter systems are used for the absolute photon dosimetry. But many electronics are demanded in order to measure the tiny temperature changes. Minimizing the control system is needed to make a portable graphite calorimeter. Methods: A Domen-type graphite calorimetry system is constructing to measure the absorbed dose of the high energy photon beam. The graphite calorimeter divided into three parts, Core, Jacket, and Shield. In order to measure the temperature rising of the core due to the radiation accurately, the temperatures of the jacket and the shield should be controlled properly. A commercial temperature controller (Model 350, Lake Shore Cryogenics) was used to minimize the size of control system for making a portable graphite calorimetry system at the cost of the measurement uncertainty. The PID control of the jacket is conducted by the software (LabView) and Model 350 maintain the temperature of shield. Results: Our design value of the heat deposition power in the core is 0.04 mW for the dose rate of 3 Gy/min where the temperature sensitivity of the graphite is 1.4 mK/Gy. While the residuals of the Steinhart-hart equation fitting for the core thermistor were less than 0.1 mK, the temperature resolution of Model 350 is 1 mK. The temperature of the shield was kept within the 5 mK when the room temperature variation was about 0.5 K. Conclusion: The resolution of Model 350 for the temperature measurement and control is not good enough as the control system for the compact graphite calorimetry system. But The performance of Model 350 is good enough to maintain the temperature of the shield constantly. The Model 350 will be replaced by the AC resistance bridge (Model 372, Lake Shore Cryogenics) for the core temperature measurement and the jacket control.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-490: Independent Three-Dimensional (3D) Dose Verification of VMAT/SBRT Using EPID and Cloud Computing

Purpose: Dosimetric verification of VMAT/SBRT is currently performed on one or two planes in a phantom with either film or array detectors. A robust and easy-to-use 3D dosimetric tool has been sought since the advent of conformal radiation therapy. Here we present such a strategy for independent 3D VMAT/SBRT plan verification system by a combined use of EPID and cloud-based Monte Carlo (MC) dose calculation. Methods: The 3D dosimetric verification proceeds in two steps. First, the plan was delivered with a high resolution portable EPID mounted on the gantry, and the EPID-captured gantry-angle-resolved VMAT/SBRT field images were converted into fluence by using the EPID pixel response function derived from MC simulations. The fluence was resampled and used as the input for an in-house developed Amazon cloud-based MC software to reconstruct the 3D dose distribution. The accuracy of the developed 3D dosimetric tool was assessed using a Delta4 phantom with various field sizes (square, circular, rectangular, and irregular MLC fields) and different patient cases. The method was applied to validate VMAT/SBRT plans using WFF and FFF photon beams (Varian TrueBeam STX). Results: It was found that the proposed method yielded results consistent with the Delta4 measurements. For points on the two detector planes, a good agreement within 1.5% were found for all the testing fields. Patient VMAT/SBRT plan studies revealed similar level of accuracy: an average γ-index passing rate of 99.2± 0.6% (3mm/3%), 97.4± 2.4% (2mm/2%), and 72.6± 8.4 % ( 1mm/1%). Conclusion: A valuable 3D dosimetric verification strategy has been developed for VMAT/SBRT plan validation. The technique provides a viable solution for a number of intractable dosimetry problems, such as small fields and plans with high dose gradient.

60 APPLIED LIFE SCIENCES↗

Simulation-based Design of a Shadow Shield for the MIND Backpack System

Modeling and simulation is a cost- and time-saving method to study conceptual designs of radiation detection systems. MCNP radiation transport code has been an indispensable tool in development of radiation detection systems, and the PINS systems have also utilized MCNP modeling and simulation in the system development. MCNP models of the PINS systems have been used to understand detector responses and to fill the gap in experimental data. Recently, the MIND backpack system was announced to be developed, and its prototype design was required to conduct laboratory tests and demonstrations. A shadow shield is the component to be designed by Idaho National Laboratory in order to maximize the performance of a backpack system while meeting the sponsor’s requirements. MCNP modeling and simulation was utilized to find the best specification of a shadow shield. This study was performed to down-select a shadow shield design for the MIND system. A total of 24 designs for a shadow shield were identified to build MCNP models, and their simulation results were used to prioritize each design. As a quantitative performance metric, an equation of Figure-of-Merit was introduced in the decision making analysis. In addition, the Analytic Hierarchy Process was adopted to prioritize and recommend best performing shadow shield designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FPGA-based prototype of portable environmental radiation monitor

This new portable radiological environmental monitor consists of 2 main components, Gamma ionization chamber and a FPGA-based electronic enclosure linked to convivial software for treatment and analyzing. The HPIC ion chamber is the heart of this radiation measurement system and is running in range from 0 to 100 mR/h, so that the sensitivity at the output is 20 mV/μR/h, with a nearly flat energy response from 0,07 to 10 MEV. This paper presents a contribution for developing a new nuclear measurement data acquisition system based on Cyclone III FPGA Starter Kit ALTERA, and a user-friendly software to run real-time control and data processing. It was developed to substitute the older radiation monitor RSS-112 PIC installed in CNESTEN's Laboratory in order to improve some of its functionalities related to acquisition time and data memory capacity. As for the associated acquisition software, it was conceived under the virtual LabView platform from National Instrument, and offers a variety of system setup for radiation environmental monitoring. It gives choice to display both the statistical data and the dose rate. Statistical data shows a summary of current data, current time/date and dose integrator values, and the dose rate displays the current dose rate in large numbers for viewing from a distance as well as the date and time. The prototype version of this new instrument and its data processing software has been successfully tested and validated for viewing and monitoring the environmental radiation of Moroccan nuclear center. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-G-204-09: Medical Physics 2.0 in Practice: Automated QC Assessment of Clinical Chest Images

Purpose: To determine whether a proposed suite of objective image quality metrics for digital chest radiographs is useful for monitoring image quality in our clinical operation. Methods: Seventeen gridless AP Chest radiographs from a GE Optima portable digital radiography (DR) unit (Group 1), seventeen (routine) PA Chest radiographs from a GE Discovery DR unit (Group 2), and sixteen gridless (non-routine) PA Chest radiographs from the same Discovery DR unit (Group 3) were chosen for analysis. Groups were selected to represent “sub-standard” (Group 1), “standard-of-care” (Group 2), and images with a gross technical error (Group 3). Group 1 images were acquired with lower kVp (90 vs. 125), shorter source-to-image distance (127cm vs 183cm) and were expected to have lower quality than images in Group 2. Group 3 was expected to have degraded contrast versus Group 2.This evaluation was approved by the institutional Quality Improvement Assurance Board (QIAB). Images were anonymized and securely transferred to the Duke University Clinical Imaging Physics Group for analysis using software previously described{sup 1} and validated{sup 2}. Image quality for individual images was reported in terms of lung grey level(Lgl); lung noise(Ln); rib-lung contrast(RLc); rib sharpness(Rs); mediastinum detail(Md), noise(Mn), and alignment(Ma); subdiaphragm-lung contrast(SLc); and subdiaphragm area(Sa). Metrics were compared across groups. Results: Metrics agreed with published Quality Consistency Ranges with three exceptions: higher Lgl, lower RLc, and SDc. Higher bit depth (16 vs 12) accounted for higher Lgl values in our images. Values were most internally consistent for Group 2. The most sensitive metric for distinguishing between groups was Mn followed closely by Ln. The least sensitive metrics were Md and RLc. Conclusion: The software appears promising for objectively and automatically identifying substandard images in our operation. The results can be used to establish local quality consistency ranges and action limits per facility preferences.

60 APPLIED LIFE SCIENCES↗

Automated size-specific CT dose monitoring program: Assessing variability in CT dose

Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose estimates that were not adjusted by patient size. Additionally, considerable differences were noted in ED{sub adj} distributions between scanners, with scanners employing iterative reconstruction exhibiting significantly lower ED{sub adj} (range: 9%-64%). Finally, a significant difference (up to 59%) in ED{sub adj} distributions was observed between institutions, indicating the potential for dose reduction. Conclusions: The authors developed a robust automated size-specific radiation dose monitoring program for CT. Using this program, significant differences in ED{sub adj} were observed between scanner models and across institutions. This new dose monitoring program offers a unique tool for improving quality assurance and standardization both within and across institutions.

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-09: Towards Absolute Dose Measurement in MRI-Linac and Gamma-Knife: Design and Construction of An MR-Compatible Water Calorimeter

Purpose: The purpose of this work is to design and optimize a portable Water Calorimeter (WC) for use in a commercial MRI-linac and Gamma-knife in addition to conventional radiotherapy linacs. Water calorimeters determine absorbed dose to water at a point by measuring radiation-induced temperature rise of the volume (the two are related by the medium specific heat capacity). In this formalism, one important correction factor is heat transfer correction k-ht. It compensates for heat gain/loss due to conductive and convective effects, and is numerically calculated as ratio of temperature rise in the absence of heat loss to that in the presence of heat loss. Operating at 4°C ensures convection is minimal. Methods: A commercial finite element software was used to evaluate several WC designs with different insulation materials and thicknesses; channels allowing coolant to travel around WC (to sustain WC at 4°C) were modeled, and worst-case scenario variation in the temperature of the coolant was simulated for optimization purposes (2.6 mK/s). Additionally, several calorimeter vessel design parameters (front/back glass thickness/separation, diameter) were also simulated and optimized. Optimization is based on minimizing long term calorimeter drift (24h) as well as variation and magnitude of k-ht. Results: The final selected WC design reached a modest drift of 11µK/s after 15h for the worst-case coolant temperature variation. This design consists of coolant channels being encompassed on both sides by cryogel insulation. For the MRI-linac beam, glass thickness plays the largest effect on k-ht with variation of upto 0.6% in the first run for thicknesses ranging between 0.5–1.7mm. Subsequent runs vary only within 0.1% with glass thickness. Other factors such as vessel radius and top/bottom glass separation have sub 0.1% effects on k-ht. Conclusion: An MR-safe 4°C stagnant WC appropriate for dosimetry in MRI-linac and Gamma-Knife was designed, optimized, and construction is nearly completed. NSERC Discovery Grant RGPIN-435608.

07 ISOTOPE AND RADIATION SOURCES↗

Towards Vendor and Operating System Independence of USB-based portable multi-channel analyzers

The nuclear measurements group is called on to develop portable, user friendly systems that performs at, or near, laboratory standards. These systems typically consist of a detector and a USB-based multi-channel analyzer. An ORTEC digi-Base is an example of a USB-based portable multi-channel analyzer with 14-pin photomultiplier tube base for gamma-ray spectroscopy applications with NaI(Tl) and other scintillation detectors. Operating system independence - we want to be able to develop applications that are 'future-proof' and can run on the best hardware for the job: desktop, laptop, tablet, phone, or embedded device. To do that we need our software to be operating system independent. Hardware vendor independence - to use the most appropriate equipment for the job, while still maintaining our rapid method development, we would like our software that uses this equipment to be independent of the specific vendor or model of the hardware. To do that we need a common interface to each vendor's equipment (high voltage, gain, start, stop, clear, etc.) In prior work, we were able to use an existing library to communicate with an ORTEC digi-base via Linux and Android. However the application developed did not have a user friendly front-end. Part of this work was to develop a simple user interface to control the settings of the hardware from Android. While OS independence is the final goal, another goal is standardized software for user-application development. For current purposes those standard systems are Windows 7, Windows 10, and Python 3. Our next step was to develop a common software interface between a front-end user interface and back-end hardware communication software. This was done using Python's Ctypes library. Ctypes is a foreign function library for Python. It provides C compatible data types, and allows calling functions in DLLs or shared libraries. It can be used to wrap these libraries in pure Python. Ctypes exports the cdll, and Windows windll and oledll objects, for loading dynamic link libraries. You load libraries by accessing them as attributes of these objects. cdll loads libraries which export functions using the standard cdecl calling convention. The first steps of developing the common software interface have been done. Once the software interface has been developed the next goal will be to develop hardware specific back-end software that way rapid user facing software can be developed using equipment that is 'on-hand' and once finished prototyping, the 'best' hardware can be chosen for the specific implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Portable Quantitative High-Resolution Gamma System for In-Situ Waste, D and D, and Emergency Measurements - 18573

The Canberra ISOCS system has been a highly successful and technologically innovative product since its introduction about 22 years ago. The combination of field-portable HPGe detectors, flexible shield/collimator set, and accurate mathematical efficiency calibration software made in-situ gamma spectroscopy measurements very practical. Good quality in-situ measurements are economically beneficial for items that are either large or complex, in comparison to the cost, time and impracticality of extracting a sample for laboratory measurements or producing representative calibration standards. And where the item is not homogeneous [most of the time for in-situ measurement situations] an assay of a large part of the item has been shown to be more accurate than a few widely dispersed extracted samples [the normal case]. However the size, weight, cost and complexity of the full-size ISOCS system limit its usefulness in some situations. A companion device was recently introduced, and is the subject of this document. The gamma sensor is a 1 cm{sup 3} CZT detector. It is surrounded by an optional tungsten shield/collimator set with a tripod for support. The detector is powered solely by a USB connection from a laptop PC. The full power of the ISOCS efficiency calibration software can be used with this detector. This entire package is less than 15 kg, needs no cooling, and is quite rugged, in comparison to the 120 kg for ISOCS with sensitive HPGe detectors which need Liquid Nitrogen or electro-mechanical cooling. Furthermore this CZT package is about 1/3 the cost. This is a very complementary device for the many current ISOCS users, especially for quick initial evaluations or simple situations where the full energy resolution and sensitivity of the HPGe ISOCS are not needed. Operating nuclear power plants or those in the initial phases of decommissioning are prime examples. Their complex layout often precludes the deployment of the full-sized ISOCS system, whereas the CZT system can be hand-carried there and very quickly setup for a measurement. The small detector size, and therefore low efficiency, is not a disadvantage, and in many cases is an advantage due to the elevated radioactivity of the items. This can be used to assay items in tanks, spills on floors, activity on filters, waste or items in small containers, and waste in drums. In the event of an emergency, it can be quickly deployed to measure gas or liquid effluent streams, air particulate and iodine filters in the field, or even in-vivo thyroid activity. Examples of measurements at nuclear facilities are shown and discussed in further detail, along with estimated detection limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗