Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “central receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Off-Nominal Event Analysis in Autonomous Flights Based on Explainable Artificial Intelligence

A key objective in the Urban Air Mobility program at NASA is to intelligently perform an autonomous flight in a complex urban environment under all weather conditions with guaranteed levels of safety. To accomplish this, the mission manager (central decision-making module) of the vehicle needs to make informed decisions between various Courses of Action (CoA) based on its' interpretation of the inputs it receives. If an off-nominal event is detected either based on the amalgamation of sensor data or the use of machine learning models, the mission manager may greatly benefit from identification of the input features that most likely contributed to that specific event. Such an understanding is usually not possible to obtain from the classical machine learning models (deep learning) due to the inherent black box like structure. However, this understanding is achieved using eXplainable Artificial Intelligence (XAI) models that provide a human interpretable rationale for the predictions made. This work presents a game theory inspired XAI model for the off-nominal assessment of autonomous flights. The proposed approach based on Shapley values is model agnostic, provides local as well as global explanation and satisfies the four axioms (efficiency, symmetry, dummy, additivity) to achieve fair contribution. The versatility of the approach is first demonstrated on a simulated dataset in which the significance of each input to flight phase prediction is clearly identified. Subsequently, data from simulated flight trajectories are fed into the model which reveal the input features that most likely contributed to a rotor failure event thereby empowering the mission manager to take the appropriate CoA.

autonomy↗

Innovation Concepts in Healthcare

Demographic change and advances in medical science pose increased challenges to healthcare systems globally: The economic basis is aging and thus health is becoming more and more a productivity factor. At the same time, with today’s new communication possibilities the demand and expectations of effective medical treatment have been increased. This presentation will illustrate the need for the “industrialization” of healthcare in order to achieve highest results at limited budgets. Thereby, industrialization is not meaning the medical treatment based on the assembly line approach. Rather it is to recognize the cost of medical care as an investment with respective expectations on the return of the investment. Innovations in imaging and pharmaceutical products as well as in processes - that lead to similar medical results, but with lower efforts - are keys in such scenarios. Biography Prof. Dr. Hermann Requardt, 54, is a member of the Managing Board of Siemens AG and Chief Executive Officer of the Healthcare Sector. In addition he is the CTO of Siemens AG and Head of Corporate Technology, the central research department at Siemens. After completing his studies in physics and philosophy at the Darmstadt University of Technology and Johann Wolfgang Goethe University in Frankfurt and receiving a doctorate in biophysics, he worked at the Institute of Aerospace Medicine at the German Aerospace Center.In 1984 he joined the Medical Technology Group of Siemens AG, where he was responsible for projects in the Magnetic Resonance (MR) division. He was appointed head of the division in 1995. From 2001 to 2006, as a member of the Executive Management of the Medical Solutions Group, he was responsible for several areas, including technological development.In 2006 he became a Member of the Siemens’ Managing Board and head of Corporate Technology. He was additionally appointed as the Sector Healthcare CEO in 2008.Since 2006 he is an honorary professor in physics of the Johann Wolfgang Goethe University in Frankfurt.

HEALTHCARE↗

Improving Outcomes for Esophageal Cancer using Proton Beam Therapy

Radiation therapy (RT) plays an essential role in the management of esophageal cancer. Because the esophagus is a centrally located thoracic structure there is a need to balance the delivery of appropriately high dose to the target while minimizing dose to nearby critical structures. Radiation dose received by these critical structures, especially the heart and lungs, may lead to clinically significant toxicities, including pneumonitis, pericarditis, and myocardial infarction. Although technological advancements in photon RT delivery like intensity modulated RT have decreased the risk of such toxicities, a growing body of evidence indicates that further risk reductions are achieved with proton beam therapy (PBT). Herein we review the published dosimetric and clinical PBT literature for esophageal cancer, including motion management considerations, the potential for reirradiation, radiation dose escalation, and ongoing esophageal PBT clinical trials. We also consider the potential cost-effectiveness of PBT relative to photon RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling of Dust Levels Associated with Potential Utility-Scale Solar Development in the San Luis Valley-Taos Plateau Study Area

The San Luis Valley (SLV)–Taos Plateau study area in south-central Colorado and north-central New Mexico is a large alpine valley surrounded by mountains with an area of approximately 6,263,000 acres (25,345 km 2 ) (Figure ES.1-1). This area receives ample sunshine throughout the year, making it an ideal location for solar energy generation, and there are currently five photovoltaic facilities operating on private lands in the SLV, ranging in capacity from 1 to 30 megawatt (MW). In 2012 the Bureau of Land Management (BLM) launched its Solar Energy Program, which included the identification of four solar energy zones (SEZs) in the SLV totaling 16,308 acres (66 km 2 ), as well as over 50,000 (202 km 2 ) acres of other BLM-administered lands potentially available for application for solar development. The SEZ areas, named Antonito Southeast, De Tilla Gulch, Fourmile East, and Los Mogotes East, were defined by the BLM as areas well-suited for utility-scale (i.e., larger than 20 MW) production of solar energy where solar energy development would be prioritized (BLM 2012). Nonetheless, it was recognized that solar development in the SEZs would result in some unavoidable adverse impacts, and so the BLM initiated a solar regional mitigation strategy (SRMS) study for three of the SEZs (BLM and Argonne 2016). The SRMS is designed to identify residual impacts of solar development in the SEZs (that is, those that cannot be avoided or minimized onsite), identify those residual impacts that warrant compensatory mitigation when considering the regional status and trends of the resources, identify appropriate regional compensatory mitigation locations and actions to address those residual impacts, and recommend appropriate fees to implement those compensatory mitigation measures.

14 SOLAR ENERGY↗

A radiological assessment of nuclear power and propulsion operations near Space Station Freedom

Scenarios were identified which involve the use of nuclear power systems in the vicinity of Space Station Freedom (SSF) and their radiological impact on the SSF crew was quantified. Several of the developed scenarios relate to the use of SSF as an evolutionary transportation node for lunar and Mars missions. In particular, radiation doses delivered to SSF crew were calculated for both the launch and subsequent return of a Nuclear Electric Propulsion (NEP) cargo vehicle and a Nuclear Thermal Rocket (NTR) personnel vehicle to low earth orbit. The use of nuclear power on co-orbiting platforms and the storage and handling issues associated with radioisotope power systems were also explored as they relate to SSF. A central philosophy in these analyses was the utilization of a radiation dose budget, defined as the difference between recommended dose limits from all radiation sources and estimated doses received by crew members from natural space radiations. Consequently, for each scenario examined, the dose budget concept was used to identify and quantify constraints on operational parameters such as launch separation distances, returned vehicle parking distances, and reactor shutdown times prior to vehicle approach. The results indicate that realistic scenarios do not exist which would preclude the use of nuclear power sources in the vicinity of SSF. The radiation dose to the SSF crew can be maintained at safe levels solely by implementing proper and reasonable operating procedures.

Bolch, Wesley E.↗

Recovery of a geocentric reference frame using the present-day GPS system

A geocentric reference frame adopts the center of mass of the earth as the origin of the coordinate axes. The center of mass of the earth is the natural and unambiguous origin of a geocentric satellite dynamical system. But in practice a kinematically obtained terrestrial reference frame may assume an origin other than the geocenter. The establishment of a geocentric reference frame, to which all relevant observations and results can be referred and in which geodynamic theories or models for the dynamic behavior of earth can be formulated, requires the ability to accurately recover a given coordinate frame origin offset from the geocenter. GPS measurements, because of their abundance and broad distribution, provide a powerful tool to obtain this origin offset in a short period of time. Two effective strategies have been devised. Data from the First Central And South America (Casa Uno) geodynamics experiment has been studied, in order to demonstrate the ability of recovering the geocenter location with present day GPS satellites and receivers.

Malla, Rajendra P.↗

NASA Tech Briefs, February 2005

Topics discussed include: Instrumentation for Sensitive Gas Measurements; Apparatus for Testing Flat Specimens of Thermal Insulation; Quadrupole Ion Mass Spectrometer for Masses of 2 to 50 Da; Miniature Laser Doppler Velocimeter for Measuring Wall Shear; Coherent Laser Instrument Would Measure Range and Velocity; Printed Microinductors for Flexible Substrates; Digital Receiver for Microwave Radiometry; Printed Antennas Made Reconfigurable by Use of MEMS Switches; Traffic-Light-Preemption Vehicle-Transponder Software Module; Intersection-Controller Software Module; Central-Monitor Software Module; Estimating Effects of Multipath Propagation on GPS Signals; Parallel Adaptive Mesh Refinement Library; Predicting Noise From Aircraft Turbine-Engine Combustors; Generating Animated Displays of Spacecraft Orbits; Diagnosis and Prognosis of Weapon Systems; Training Software in Artificial-Intelligence Computing Techniques; APGEN Version 5.0; Single-Command Approach and Instrument Placement by a Robot on a Target; Three-Dimensional Audio Client Library; Isogrid Membranes for Precise, Singly Curved Reflectors; Nickel-Tin Electrode Materials for Nonaqueous Li-Ion Cells; Photocatalytic Coats in Glass Drinking-Water Bottles; Fast Laser Shutters With Low Vibratory Disturbances; Series-Connected Buck Boost Regulators; Space Physics Data Facility Web Services; Split-Resonator, Integrated-Post Vibratory Microgyroscope; Blended Buffet-Load-Alleviation System for Fighter Airplane; Gifford-McMahon/Joule-Thomson Refrigerator Cools to 2.5 K; High-Temperature, High-Load-Capacity Radial Magnetic Bearing; Fabrication of Spherical Reflectors in Outer Space; Automated Rapid Prototyping of 3D Ceramic Parts; Tissue Engineering Using Transfected Growth-Factor Genes; Automation of Vapor-Diffusion Growth of Protein Crystals; Atom Skimmers and Atom Lasers Utilizing Them; Gears Based on Carbon Nanotubes; Patched Off-Axis Bending/Twisting Actuators for Thin Mirrors; and Improving Control in a Joule-Thomson Refrigerator.

Source record↗

Large doppler shift in radar detection of ultra-high energy cosmic rays.

Radar detection of cosmic ray air showers has been discussed for 60 years, but never clearly observed. The topic was reexamined by Gorham in 2001 and some serious simulations were done by Takai, who also initiated the Mariachi project utilizing commercial television transmissions as a signal source. The air showers from ultra-high energy cosmic rays are expected to generate a plasma with plasma frequency in the high VHF region. One factor limiting the received signal strength is the short ion recombination time in air at low altitude. However, a major factor which has not been the center of attention so far is the possible large Doppler shifts for non-specular reflection, and the soft transition between specular and diffuse for small objects and short time scales. We discuss recent work on receivers, and simulations of the Doppler shift. These simulations assume a very short ion recombination time in the lower atmosphere, and use an extremely simple mathematical model. A central feature of our simulations is large Doppler shift from non-moving material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RF Device for Acquiring Images of the Human Body

A safe, non-invasive method for forming images through clothing of large groups of people, in order to search for concealed weapons either made of metal or not, has been developed. A millimeter wavelength scanner designed in a unique, ring-shaped configuration can obtain a full 360 image of the body with a resolution of less than a millimeter in only a few seconds. Millimeter waves readily penetrate normal clothing, but are highly reflected by the human body and concealed objects. Millimeter wave signals are nonionizing and are harmless to human tissues when used at low power levels. The imager (see figure) consists of a thin base that supports a small-diameter vertical post about 7 ft (=2.13 m) tall. Attached to the post is a square-shaped ring 2 in. (=5 cm) wide and 3 ft (=91 cm) on a side. The ring is oriented horizontally, and is supported halfway along one side by a connection to a linear bearing on the vertical post. A planar RF circuit board is mounted to the inside of each side of the ring. Each circuit board contains an array of 30 receivers, one transmitter, and digitization electronics. Each array element has a printed-circuit patch antenna coupled to a pair of mixers by a 90 coupler. The mixers receive a reference local oscillator signal to a subharmonic of the transmitter frequency. A single local oscillator line feeds all 30 receivers on the board. The resulting MHz IF signals are amplified and carried to the edge of the board where they are demodulated and digitized. The transmitted signal is derived from the local oscillator at a frequency offset determined by a crystal oscillator. One antenna centrally located on each side of the square ring provides the source illumination power. The total transmitted power is less than 100 mW, resulting in an exposure level that is completely safe to humans. The output signals from all four circuit boards are fed via serial connection to a data processing computer. The computer processes the approximately 1-MB data set into a three-dimensional image in a matter of seconds. The innovation is to configure the receiver array in a ring topology surrounding the scanned object. The ring is then scanned vertically to cover the necessary two-dimensional surface. This fabrication of the ring is made possible by using planar antenna and circuit technology. A planar circuit board serves as a medium for both antennas and signal processing components. Using this technique, parts counts are kept low, and the cost per element is a small fraction of a waveguide-based system.

Gaier, Todd C.↗

Can We Predict Plan Quality for External Beam Partial Breast Irradiation: Results of a Multicenter Feasibility Study (Trans Tasman Radiation Oncology Group Study 06.02)

Purpose: Partial breast irradiation (PBI) after lumpectomy may be an option for selected patients with early breast cancer. A feasibility study of accelerated PBI delivered using external beam 3-dimensional conformal radiation therapy (RT) was undertaken at 8 Australasian centers. The present study evaluated the impact of patient, tumor, and RT technique-related factors on the quality of RT plans as determined by the dose–volume parameters of organs at risk. Methods and Materials: Forty-eight patients were enrolled in the study. All RT plans were centrally reviewed using predefined dosimetric criteria before commencement and after completion of protocol therapy. The RT plans of 47 patients met the dose–volume constraints, and all 47 patients received PBI to a prescribed dose of 38.5 Gy in 10 fractions. The RT plan quality was determined by volumes of the ipsilateral whole breast, lung, and heart that received 50% and 95%; 30%; and 5% of the prescribed dose, respectively. Patient, tumor, and RT technique-related factors were investigated for association with the parameters of RT plan quality. Results: The ratio of the planning target volume to the ipsilateral whole-breast volume was significantly associated with the ipsilateral breast doses on multiple variable analyses. The distance of the postlumpectomy surgical cavity from the heart and lung were predictive for heart and lung doses, respectively. A distance between surgical cavity and heart of >4 cm typically resulted in <1% of the heart volume receiving 5 Gy or less. It was more difficult to meet the heart dose constraint for left-sided and medially located tumors. Conclusions: Partial breast irradiation using 3-dimensional conformal RT was feasible within the study constraints. The ratio of planning target volume to ipsilateral whole-breast volume and the distance of surgical cavity from the heart were significant predictors of the quality of treatment plan for external beam PBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Personal Beacon

The MicroPLB (personal locator beacon) is a search and rescue satellite-aided tracking (SARSAT) transmitter. When activated it emits a distress signal to a constellation of internationally operated satellites. The endangered person's identity and location anywhere on Earth is automatically forwarded to central monitoring stations around the world. It is accurate to within just a few meters. The user uses the device to download navigation data from a global positioning satellite receiver. After the download is complete, the MicroPLB functions as a self-locating beacon. Also, it is the only PLB to use a safe battery. In the past, other PLB devices have used batteries that have enough volatility to explode with extreme force. It was developed by Microwave Monolithic, Inc. through SBIR funding from Glenn Research Center and Goddard Space Flight Center.

Source record↗

Ground and Airborne Methane Measurements using Optical Parametric Amplifiers

We report on an initial airborne demonstration of atmospheric methane column measurements at 1.65 micrometers using a widely tunable, seeded optical parametric amplifier (OPA) lidar and a photon counting detector. Methane is an important greenhouse gas and accurate knowledge of its sources and sinks is needed for climate modeling. Our lidar system uses 20 pulses at increasing wavelengths and integrated path differential absorption (IPDA) to map a methane line at 1650.9 nanometers. The wavelengths are generated by using a Nd:YAG pump laser at 1064.5 nanometers and distributed feedback diode laser at 1650.9 nanometers and a periodically-poled lithium niobate (PPLN) crystal. The pulse width was 3 nanoseconds and the pulse repetition rate was 6.28 KHz. The outgoing energy was approximately 13 microJoules/pulse. A commercial 20 nanometer diameter fiber-coupled telescope with a photon counting detector operated in analog mode with a 0.8 nanometer bandpass filter was used as the lidar receiver. The lidar system was integrated on NASA's DC-8 flying laboratory, based at Dryden Airborne operations Facility (DAOF) in Palmdale CA. Three flights were performed in the central valley of California. Each flight lasted about 2.5 hours and it consisted of several flight segments at constant altitudes at approximately 3, 4.5, 6, 7.6, 9.1, 10.6 km (l0, 15, 20, 25, 30, 35 kft). An in-situ cavity ring down spectrometer made by Picarro Inc. was flown along with the lidar instrument provided us with the "truth" i.e. the local CH4, CO2 and H2O concentrations at the constant flight altitude segments. Using the aircraft's altitude, GPS, and meteorological data we calculated the theoretical differential optical depth of the methane absorption at increasing altitudes. Our results showed good agreement between the experimentally derived optical depth measurements from the lidar instrument and theoretical calculations as the flight altitude was increased from 3 to 10.6 kilometers, assuming a constant methane mixing ratio of 1.8 parts per million. The in-situ spectrometer did not show any significant deviations from the ambient concentrations. Further analysis using meteorological data from the Global Modeling and Assimilation Office (http://gmao.gsfc.nasa.gov/) to derive the theoretical optical depth also showed good agreement with the experimentally derived values. The OPA lidar system with slight modifications has also been used to measure CO2, water vapor, and CO in the near and mid-infrared spectral regions on the ground.

Riris, Haris↗

The NASA Biological Institutional Scientific Collection (NBISC): Tissue and Microbe Biospecimens to Advance Space Research

The NASA Biological Institutional Scientific Collection (NBISC) is a biorepository of non-human biospecimens from NASA-funded spaceflight investigations and correlative ground studies. The collection has its roots in the 1960s through collaborations by NASA Ames Research Center with other NASA centers, universities, and international space agencies by sharing non-human biospecimens from spaceflight and space-relevant ground experiments. These collaborations have advanced the field of space exploration by helping to maximize the data gained from spaceflight and other NASA-funded experiments. NBISC coordinates closely with the Biospecimen Sharing Program (BSP) which is responsible for organized sample collection from spaceflight and ground rodent experiments. In 2022 NBISC partnered with HRP’s Biospecimen and Tissue Sharing Collection (BTSC) Program to also archive samples from HRP’s Space Radiation Element-funded studies which primarily involve rodents exposed to various radiation protocols at the NASA Space Radiation Laboratory (NSRL) and other analog facilities. To date, more than fifty thousand biospecimens from BTSC have been transferred to NBISC for distribution to the community. In 2023, NBISC embarked on a new Space Biology funded endeavor to create the Space Microbial Culture Collection (SMCC) which will serve as a central repository for microbial isolates associated with space flight, gravitational, and space radiation research. This presentation will highlight several success stories of analyses carried out using archived NBISC samples received by researchers in recent years and will detail the process for proposing and receiving samples from NBISC, BTSC and SMCC. Making available these 150,000+ unique biospecimens to the scientific research community, NBISC not only serves as a repository for storing and distributing non-human biospecimens, but also acts as a resource to enable new discoveries that will benefit NASA and humankind.

NBISC↗

The NASA Biological Institutional Scientific Collection (NBISC): Tissue and Microbe Biospecimens to Advance Space Research

The NASA Biological Institutional Scientific Collection (NBISC) is a biorepository of non-human biospecimens from NASA-funded spaceflight investigations and correlative ground studies. The collection has its roots in the 1960s through collaborations by NASA Ames Research Center with other NASA centers, universities, and international space agencies by sharing non-human biospecimens from spaceflight and space-relevant ground experiments. These collaborations have advanced the field of space exploration by helping to maximize the data gained from spaceflight and other NASA-funded experiments. NBISC coordinates closely with the Biospecimen Sharing Program (BSP) which is responsible for organized sample collection from spaceflight and ground rodent experiments. In 2022 NBISC partnered with HRP’s Biospecimen and Tissue Sharing Collection (BTSC) Program to also archive samples from HRP’s Space Radiation Element-funded studies which primarily involve rodents exposed to various radiation protocols at the NASA Space Radiation Laboratory (NSRL) and other analog facilities. To date, more than fifty thousand biospecimens from BTSC have been transferred to NBISC for distribution to the community. In 2023, NBISC embarked on a new Space Biology funded endeavor to create the Space Microbial Culture Collection (SMCC) which will serve as a central repository for microbial isolates associated with space flight, gravitational, and space radiation research. This presentation will highlight several success stories of analyses carried out using archived NBISC samples received by researchers in recent years and will detail the process for proposing and receiving samples from NBISC, BTSC and SMCC. Making available these 150,000+ unique biospecimens to the scientific research community, NBISC not only serves as a repository for storing and distributing non-human biospecimens, but also acts as a resource to enable new discoveries that will benefit NASA and humankind.

Biospecimen↗

Modular fuel-cell stack assembly

A modular multi-stack fuel-cell assembly in which the fuel-cell stacks are situated within a containment structure and in which a gas distributor is provided in the structure and distributes received fuel and oxidant gases to the stacks and receives exhausted fuel and oxidant gas from the stacks so as to realize a desired gas flow distribution and gas pressure differential through the stacks. The gas distributor is centrally and symmetrically arranged relative to the stacks so that it itself promotes realization of the desired gas flow distribution and pressure differential.

30 DIRECT ENERGY CONVERSION↗

Spiking Neurons for Analysis of Patterns

Artificial neural networks comprising spiking neurons of a novel type have been conceived as improved pattern-analysis and pattern-recognition computational systems. These neurons are represented by a mathematical model denoted the state-variable model (SVM), which among other things, exploits a computational parallelism inherent in spiking-neuron geometry. Networks of SVM neurons offer advantages of speed and computational efficiency, relative to traditional artificial neural networks. The SVM also overcomes some of the limitations of prior spiking-neuron models. There are numerous potential pattern-recognition, tracking, and data-reduction (data preprocessing) applications for these SVM neural networks on Earth and in exploration of remote planets. Spiking neurons imitate biological neurons more closely than do the neurons of traditional artificial neural networks. A spiking neuron includes a central cell body (soma) surrounded by a tree-like interconnection network (dendrites). Spiking neurons are so named because they generate trains of output pulses (spikes) in response to inputs received from sensors or from other neurons. They gain their speed advantage over traditional neural networks by using the timing of individual spikes for computation, whereas traditional artificial neurons use averages of activity levels over time. Moreover, spiking neurons use the delays inherent in dendritic processing in order to efficiently encode the information content of incoming signals. Because traditional artificial neurons fail to capture this encoding, they have less processing capability, and so it is necessary to use more gates when implementing traditional artificial neurons in electronic circuitry. Such higher-order functions as dynamic tasking are effected by use of pools (collections) of spiking neurons interconnected by spike-transmitting fibers. The SVM includes adaptive thresholds and submodels of transport of ions (in imitation of such transport in biological neurons). These features enable the neurons to adapt their responses to high-rate inputs from sensors, and to adapt their firing thresholds to mitigate noise or effects of potential sensor failure. The mathematical derivation of the SVM starts from a prior model, known in the art as the point soma model, which captures all of the salient properties of neuronal response while keeping the computational cost low. The point-soma latency time is modified to be an exponentially decaying function of the strength of the applied potential. Choosing computational efficiency over biological fidelity, the dendrites surrounding a neuron are represented by simplified compartmental submodels and there are no dendritic spines. Updates to the dendritic potential, calcium-ion concentrations and conductances, and potassium-ion conductances are done by use of equations similar to those of the point soma. Diffusion processes in dendrites are modeled by averaging among nearest-neighbor compartments. Inputs to each of the dendritic compartments come from sensors. Alternatively or in addition, when an affected neuron is part of a pool, inputs can come from other spiking neurons. At present, SVM neural networks are implemented by computational simulation, using algorithms that encode the SVM and its submodels. However, it should be possible to implement these neural networks in hardware: The differential equations for the dendritic and cellular processes in the SVM model of spiking neurons map to equivalent circuits that can be implemented directly in analog very-large-scale integrated (VLSI) circuits.

Huntsberger, Terrance↗

Preemptive cache management policies for processing units

A processing system includes at least one central processing unit (CPU) core, at least one graphics processing unit (GPU) core, a main memory, and a coherence directory for maintaining cache coherence. The at least one CPU core receives a CPU cache flush command to flush cache lines stored in cache memory of the at least one CPU core prior to launching a GPU kernel. The coherence directory transfers data associated with a memory access request by the at least one GPU core from the main memory without issuing coherence probes to caches of the at least one CPU core.

Kayiran, Onur↗

Feasibility of Helical Tomotherapy in Stereotactic Body Radiation Therapy for Centrally Located Early Stage Non-Small-Cell Lung Cancer or Lung Metastases

Purpose: To investigate the ability of helical tomotherapy (HT) to spare critical organs immediately adjacent to the tumor target in stereotactic body radiation therapy (SBRT) for centrally located lung lesions. Methods and Materials: HT SBRT plans for 10 patients with centrally located lesions or lesions immediately adjacent to a critical structure were generated. A total of 70 Gy in 10 fractions was prescribed to the planning target volume (PTV) to satisfy a target volume coverage of {>=}95% PTV receiving 70 Gy and an established set of dose constraints for the organs at risk (OARs). Quality assurance (QA) of the HT plans was performed with both ion chamber and film measurements. Results: The PTV coverage criteria was met with 95% of the PTV receiving 70.68 {+-} 0.33 Gy for all cases even though the OARs immediately adjacent to the PTV ranged from 0.38 to 0.85 cm away. The mean lung dose (MLD), and V{sub 20} were 7.15 {+-} 1.44 Gy, and 11.93 {+-} 3.24 % for the total lung, respectively. The dose parameters of MLD, V{sub 5}, V{sub 10}, and V{sub 20} for the contralateral lung were significantly lower than those for the ipsilateral lung (p < 0.05). An average dose fall off from the PTV periphery to the edge of the immediately adjacent OAR was 47.6% over an average distance of 4.87 mm. Comparison of calculated and measured doses with the ion chamber showed an average of 1.85% point dose error, whereas an average mean gamma and the area with a gamma larger than 1 of 0.20 and 0.94% were observed, respectively. Conclusion: HT allows the sparing of critical structures immediately adjacent to the tumor target, thus making SBRT for these centrally located lesions feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗