Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

ProvLight: Efficient Workflow Provenance Capture on the Edge-to-Cloud Continuum

Modern scientific workflows require hybrid infrastructures combining numerous decentralized resources on the IoT/Edge interconnected to Cloud/HPC systems (aka the Computing Continuum) to enable their optimized execution. Understanding and optimizing the performance of such complex Edge-to-Cloud workflows is challenging. Capturing the provenance of key performance indicators, with their related data and processes, may assist in understanding and optimizing workflow executions. However, the capture overhead can be prohibitive, particularly in resource-constrained devices, such as the ones on the IoT/Edge.To address this challenge, based on a performance analysis of existing systems, we propose ProvLight, a tool to enable efficient provenance capture on the IoT/Edge. We leverage simplified data models, data compression and grouping, and lightweight transmission protocols to reduce overheads. We further integrate ProvLight into the E2Clab framework to enable workflow provenance capture across the Edge-to-Cloud Continuum. This integration makes E2Clab a promising platform for the performance optimization of applications through reproducible experiments.We validate ProvLight at a large scale with synthetic workloads on 64 real-life IoT/Edge devices in the FIT IoT LAB testbed. Evaluations show that ProvLight outperforms state-of-the-art systems like ProvLake and DfAnalyzer in resource-constrained devices. ProvLight is 26—37x faster to capture and transmit provenance data; uses 5—7x less CPU; 2x less memory; transmits 2x less data; and consumes 2—2.5x less energy. ProvLight [1] and E2Clab [2] are available as open-source tools.

Rosendo, Daniel↗

Capture-gated Spectroscopic Measurements of Monoenergetic Neutrons with a Composite Scintillation Detector

Abstract—We report on the measurements of Monoenergetic neutrons from DD and DT fusion reactions by use of the capture gating method in a heterogeneous plastic-glass composite scintillation detector. The cylindrical detector is 5.08 cm in diameter and 5.05 cm in height and was fabricated using 1-mm diameter Li-doped glass rods(GS20) and scintillating polyvinyl toluene (EJ-290). Different scintillation decay constants are used to identify energy depositions in two materials constituting the composite scintillator. Geant4 simulations of the neutron thermalization and capture process were conducted, finding a mean capture time of approximately 2.6 ms for both DD and DT neutrons. A capture gating time acceptance window based on simulation results was used to identify the neutron thermalization pulses. The total scintillation light yield produced in neutron thermalization was measured and found to show consistency on event-by-event basis despite the variety of neutron thermalization histories prior to capture. The ratio of light yields from thermalization of 14.1 MeV and 2.45 MeV neutrons in the EJ-290 scintillator was determined to be 14.6, and the light output from 2.45 MeV neutrons was also correlated to its electron equivalent, obtaining a value of 0.58*0.05 MeVee.

47 OTHER INSTRUMENTATION↗

The Effects of Synthesis Conditions on the Carbon Capture Capacity of Polyethylenimine Impregnated Protonated Titanate Nanotubes

Capture and storage of carbon dioxide emitted from power plants, which burn fossil fuels, is one of the best ways to mitigate climate change. Polyethylenimine (PEI) impregnated protonated titanate nanotubes (PEI-PTNTs) are efficient amine-modified solid adsorbents for post combustion carbon capture. This study is to investigate the effects of synthesis conditions of titanate nanotubes on the carbon capture capacity of PEI-PTNTs. PTNTs are synthesized using hydrothermal treatment of TiO 2 anatase powder at different temperatures and in different days, followed by washing with dilute HCl solution and deionized water. PEI-PTNTs are prepared by loading PEI (M.W. = 10,000) onto PTNTs at a weight ratio of 1:1 using a wet impregnation process. PTNTs and PEI-PTNTs are characterized using transmission electron microscopy, porosity and surface area analysis, powder X-ray diffraction, and Fourier transform infrared spectroscopy. CO 2 adsorption is conducted at 75 °C using simulated flue gas, and CO 2 desorption is performed at 110 °C by purging the adsorbent with dry nitrogen gas. CO 2 adsorption experiments demonstrate that the PEI-PTNTs synthesized at 130 °C within 3 or 5 days, have the highest CO 2 capture capacity. These optimized PEI-PTNTs have a significant potential to capture CO 2 from power plants.

Materials Science↗

Bench-Scale Development of a Hot Carbonate Absorption Process with Crystallization-Enabled High-Pressure Stripping for Post-Combustion CO 2 Capture (Final Scientific/Technical Report)

A novel Hot Carbonate Absorption Process with Crystallization-Enabled High-Pressure Stripping (Hot-CAP) has been developed by the University of Illinois at Urbana-Champaign and Carbon Capture Scientific, LLC in this three-year, bench-scale project. The Hot-CAP features a concentrated carbonate solution (e.g., K 2 CO 3 ) for CO 2 absorption and a bicarbonate slurry (e.g., KHCO 3 ) for high-pressure CO 2 stripping to overcome the energy use and other disadvantages associated with the benchmark monoethanolamine (MEA) process. The project was aimed at performing laboratory- and bench-scale experiments to prove its technical feasibility and generate process engineering and scale-up data, and conducting a techno-economic analysis (TEA) to demonstrate its energy use and cost competitiveness over MEA. To meet project goals and objectives, a combination of experimental, modeling, process simulation, and economic analysis studies were applied. Carefully designed and intensive experiments were conducted to measure thermodynamic and reaction engineering data relevant to four major unit operations in the Hot-CAP (i.e., CO 2 absorption, CO 2 stripping, bicarbonate crystallization, and sulfate reclamation). The rate promoters that could accelerate the CO 2 absorption rate into the potassium carbonate/bicarbonate (PCB) solution to a level greater than that into the 5 M MEA solution were identified, and the superior performance of CO 2 absorption into PCB was demonstrated in a bench-scale packed-bed column. Kinetic data on bicarbonate crystallization were developed and applied for crystallizer design and sizing. Parametric testing of high-pressure CO 2 stripping with concentrated bicarbonate-dominant slurries at high temperatures (≥140°C) in a bench-scale stripping column demonstrated lower heat use than with MEA. The feasibility of a modified process for combining SO 2 removal with CO 2 capture was preliminarily demonstrated. In addition to the experimental studies, the technical challenges pertinent to fouling of slurry-handling equipment and the design of the crystallizer and stripper were addressed through consultation with vendors and engineering analyses. A process flow diagram of the Hot-CAP was then developed and a TEA was performed to compare the energy use and cost performance of a nominal 550-MWe subcritical pulverized coal (PC)-fired power plant without CO 2 capture (DOE/NETL Case 9) with the benchmark MEA-based post-combustion CO 2 capture (PCC; DOE/NETL Case 10) and the Hot-CAP-based PCC. The results revealed that the net power produced in the PC + Hot-CAP is 609 MWe, greater than the PC + MEA (550 MWe). The 20-year levelized cost of electricity (LCOE) for the PC + Hot-CAP, including CO 2 transportation and storage, is 120.3 mills/kWh, a 60% increase over the base PC plant without CO 2 capture. The LCOE increase for the Hot-CAP is 29% lower than that for MEA. TEA results demonstrated that the Hot-CAP is energy-efficient and cost-effective compared with the benchmark MEA process.

54 ENVIRONMENTAL SCIENCES↗

Pilot-Scale Silicone Process for Low-Cost Carbon Dioxide Capture Preliminary Techno-Economic Analysis

This report presents system and economic analysis for a carbon-capture unit which uses an aminosilicone-based solvent for CO{sub 2} capture in a pulverized coal (PC) boiler. The aminosilicone solvent is a 60/40 wt/wt mixture of 3-aminopropyl end-capped polydimethylsiloxane (GAP-1m) with tri-ethylene glycol (TEG) as a co-solvent. For comparison purposes, the report also shows results for a carbon-capture unit based on a conventional approach using mono-ethanol amine (MEA). The first year removal cost of CO{sub 2} for the aminosilicone-based carbon-capture process is $46.04/ton of CO2 as compared to $60.25/ton of CO{sub 2} when MEA is used. The aminosilicone-based process has <77% of the CAPEX of a system using MEA solvent. The lower CAPEX is due to several factors, including the higher working capacity of the aminosilicone solvent compared the MEA, which reduces the solvent flow rate required, reducing equipment sizes. If it is determined that carbon steel can be used in the rich-lean heat exchanger in the carbon capture unit, the first year removal cost of CO{sub 2} decreases to $44.12/ton. The aminosilicone-based solvent has a higher thermal stability than MEA, allowing desorption to be conducted at higher temperatures and pressures, decreasing the number of compressor stages needed. The aminosilicone-based solvent also has a lower vapor pressure, allowing the desorption to be conducted in a continuous-stirred tank reactor versus a more expensive packed column. The aminosilicone-based solvent has a lower heat capacity, which decreases the heat load on the desorber. In summary, the amino-silicone solvent has significant advantages over conventional systems using MEA.

54 ENVIRONMENTAL SCIENCES↗

Pilot-Scale Silicone Process for Low-Cost Carbon Dioxide Capture

This report presents system and economicanalysis for a carbon-capture unit which uses an aminosilicone-based solvent for CO₂ capture in a pulverized coal (PC) boiler. The aminosilicone solvent is a 60/40 wt/wt mixture of 3-aminopropyl end-capped polydimethylsiloxane (GAP-1m) with tri-ethylene glycol (TEG) as a co-solvent. Forcomparison purposes, the report also shows results for a carbon-capture unit based on a conventional approach using mono-ethanol amine (MEA). The first year removal cost of CO₂ for the aminosilicone-based carbon-capture process is $46.04/ton of CO₂ as compared to $60.25/ton of CO₂ when MEA is used. The aminosilicone- based process has <77% of the CAPEX of a system using MEA solvent. The lower CAPEX is due to several factors, including the higher working capacity of the aminosilicone solvent compared the MEA, which reduces the solvent flow rate required, reducing equipment sizes. If it is determined that carbon steel can be used in the rich-lean heat exchanger in the carbon capture unit, the first year removal cost of CO₂ decreases to $44.12/ton. The aminosilicone-based solvent has a higherthermal stability than MEA, allowing desorption to be conducted at higher temperatures and pressures, decreasing the number of compressor stages needed. The aminosilicone-based solvent also has a lowervapor pressure, allowing the desorption to be conducted in a continuous-stirred tank reactor versus a more expensive packed column. The aminosilicone-based solvent has a lowerheat capacity, which decreases the heat load on the desorber. In summary, the amino-silicone solvent has significant advantages overconventional systems using MEA.

Singh, Surinder↗

Development of a Novel Gas Pressurized Stripping Process-Based Technology for CO₂ Capture from Post-Combustion Flue Gases

A novel Gas Pressurized Stripping (GPS) post-combustion carbon capture (PCC) process has been developed by Carbon Capture Scientific, LLC, CONSOL Energy Inc., Nexant Inc., and Western Kentucky University in this bench-scale project. The GPS-based process presents a unique approach that uses a gas pressurized technology for CO₂ stripping at an elevated pressure to overcome the energy use and other disadvantages associated with the benchmark monoethanolamine (MEA) process. The project was aimed at performing laboratory- and bench-scale experiments to prove its technical feasibility and generate process engineering and scale-up data, and conducting a techno-economic analysis (TEA) to demonstrate its energy use and cost competitiveness over the MEA process. To meet project goals and objectives, a combination of experimental work, process simulation, and technical and economic analysis studies were applied. The project conducted individual unit lab-scale tests for major process components, including a first absorption column, a GPS column, a second absorption column, and a flasher. Computer simulations were carried out to study the GPS column behavior under different operating conditions, to optimize the column design and operation, and to optimize the GPS process for an existing and a new power plant. The vapor-liquid equilibrium data under high loading and high temperature for the selected amines were also measured. The thermal and oxidative stability of the selected solvents were also tested experimentally and presented. A bench-scale column-based unit capable of achieving at least 90% CO₂ capture from a nominal 500 SLPM coal-derived flue gas slipstream was designed and built. This integrated, continuous, skid-mounted GPS system was tested using real flue gas from a coal-fired boiler at the National Carbon Capture Center (NCCC). The technical challenges of the GPS technology in stability, corrosion, and foaming of selected solvents, and environmental, health and safety risks have been addressed through experimental tests, consultation with vendors and engineering analysis. Multiple rounds of TEA were performed to improve the GPS-based PCC process design and operation, and to compare the energy use and cost performance of a nominal 550-MWe supercritical pulverized coal (PC) plant among the DOE/NETL report Case 11 (the PC plant without CO₂ capture), the DOE/NETL report Case 12 (the PC plant with benchmark MEA-based PCC), and the PC plant using GPS-based PCC. The results reveal that the net power produced in the PC plant with GPS-based PCC is 647 MWe, greater than that of the Case 12 (550 MWe). The 20-year LCOE for the PC plant with GPS-based PCC is 97.4 mills/kWh, or 152% of that of the Case 11, which is also 23% less than that of the Case 12. These results demonstrate that the GPS-based PCC process is energy-efficient and cost-effective compared with the benchmark MEA process.

Chen, Shiaoguo↗

The National Carbon Capture Center at the Power Systems Development Facility

The National Carbon Capture Center (NCCC) at the Power Systems Development Facility supports the Department of Energy (DOE) goal of promoting the United States’ energy security through reliable, clean, and affordable energy produced from coal. Work at the NCCC supports the development of new power technologies and the continued operation of conventional power plants under CO 2 emission constraints. The NCCC includes adaptable slipstreams that allow technology development of CO 2 capture concepts using coal-derived syngas and flue gas in industrial settings. Because of the ability to operate under a wide range of flow rates and process conditions, research at the NCCC can effectively evaluate technologies at various levels of maturity and accelerate their development path to commercialization. During its first contract period, from October 1, 2008, through December 30, 2014, the NCCC designed, constructed, and began operation of the Post-Combustion Carbon Capture Center (PC4). Testing of CO 2 capture technologies commenced in 2011, and through the end of the contract period, more than 25,000 hours of testing had been achieved, supporting a variety of technology developers. Technologies tested included advanced solvents, enzymes, membranes, sorbents, and associated systems. The NCCC continued operation of the existing gasification facilities, which have been in operation since 1996, to support the advancement of technologies for next-generation gasification processes and pre-combustion CO 2 capture. The gasification process operated for 13 test runs, supporting over 30,000 hours combined of both gasification and pre-combustion technology developer testing. Throughout the contract period, the NCCC incorporated numerous modifications to the facilities to accommodate technology developers and increase test capabilities. Preparations for further testing were ongoing to continue advancement of the most promising technologies for future power generation processes.

01 COAL, LIGNITE, AND PEAT↗

Novel Inorganic/Polymer Composite Membranes for CO 2 Capture

The objective of this project is to develop a cost-effective design and manufacturing process for new membrane modules that capture CO 2 from flue gas in coal-fired power plants. The membrane consisted of a thin selective layer including inorganic (zeolite) embedded in a polymer structure so that it can be made in a continuous manufacturing process. The membrane was incorporated in spiral-wound modules for the field test with actual flue gas at the National Carbon Capture Center (NCCC) in Wilsonville, AL and bench scale tests with simulated flue gas at the Ohio State University (OSU). Using the modules for post-combustion CO 2 capture is expected to achieve the DOE target of $40/tonne CO 2 captured (in 2007 dollar) for 2025. Membranes with the amine-containing polymer cover layer on zeolite-Y (ZY) nanoparticles deposited on the polyethersulfone (PES) substrate were successfully synthesized. The membranes showed a high CO 2 permeance of about 1100 GPU (gas permeation unit, 1 GPU = 10 -6 cm 3 (STP)/(cm 2 • s • cm Hg), 3000 GPU = 10-6 mol/(m 2 • s • Pa)) with a high CO 2 /N 2 selectivity of > 200 at the typical flue gas conditions at 57°C (about 17% water vapor in feed gas) and > 1400 GPU CO 2 permeance with > 500 CO 2 /N 2 selectivity at 102°C (~ 80% water vapor). The synthesis of ZY nanoparticles was successfully scaled up, and the pilot-scale membranes were also successfully fabricated using the continuous membrane machine at OSU. The transport performance of the pilot-scale membranes agreed reasonably well with the lab-scale membranes. The results from both the lab-scale and scale-up membranes were used for the techno-economic analysis. The scale-up membranes were fabricated into prototype spiral-wound membrane modules for continuous testing with simulated or real flue gas. For real flue gas testing, we worked with NCCC, in consultation with TriSep Corporation, Gradient Technology and American Electric Power (AEP). The membrane module demonstrated > 800 GPU of CO 2 permeance and > 150 CO 2 /N 2 selectivity when tested with real flue gas at NCCC. The results obtained were used to update the techno-economic analysis. In addition, the EH&S assessment of the membranes for post-combustion CO 2 capture was conducted.

20 FOSSIL-FUELED POWER PLANTS↗

Pilot-Scale Evaluation of an Advanced Carbon Sorbent-Based Process for Post-Combustion Carbon Capture

The overall objective of this project is to achieve the DOE’s goal to develop advanced CO 2 capture and separation technologies that can realize at least 90% CO 2 removal from flue gas steams produced at a pulverized coal (PC) power plant at a cost of less than $40/tonne of CO 2 captured. The principal objective is to test a CO 2 capture process that will reduce the parasitic plant load by using a CO 2 capture sorbent that will require a reduced amount of steam. The process is based on advanced carbon sorbents having a low heat of adsorption, high CO 2 adsorption capacity, and excellent selectivity. While the intent of this project was to produce design and performance data by testing the sorbent using a slipstream of coal-derived flue gas at the National Carbon Capture Center (NCCC) under realistic conditions and continuous long-term operation, the project was terminated following completion of the detailing pilot plant design/engineering work on June 30, 2016.

54 ENVIRONMENTAL SCIENCES↗

An Initial Investigation of the Design Challenges Associated with Reliable 100GigE Packet Capture

Network security researchers often rely on Emulytics TM to provide a way to evaluate the safety and security of real world systems. This work involves running a large number of virtual machines on a distributed platform to observe how software and hardware will respond to different types of attacks. While Emulytics TM software such as minimega provide a scalable system for conducting experiments, the sheer volume of network traffic produced in an experiment can easily exceed the rate at which data can be recorded for offline analysis. As such, researchers must perform live analytics, narrow their monitoring scope or accept that they must run an experiment multiple times to capture all the information they require. In support of Sandia's commitment to Emulytics TM , we are developing new storage components for the Carlin cluster that will enable researchers to capture significantly more network traffic from their experiments. This report provides a summary of Haoda Wang's initial investigation of how new AMD Epyc storage nodes can be adapted to perform packet capture at 100Gbps speeds with minimal loss. This work found that the NVMe storage capabilities of the Epyc architecture are suitable for capturing 100Gbps Ethernet traffic. While capturing traffic with existing libraries was surprisingly challenging, we were able to develop a DPDK-based software tool that recorded network traffic to disk with minimal packet loss.

97 MATHEMATICS AND COMPUTING↗

Simulations of short-term exposure to NO 2 and PM 2.5 to inform capture efficiency standards

The California building code requires all new or renovated residential dwelling units to have kitchen exhaust ventilation to manage air pollutants and moisture generated during cooking. Current performance requirements are specified as a minimum airflow and maximum sound level. This report presents an analysis to support consideration of adding a capture efficiency requirement to the code. The analysis uses a physics-based simulation model to calculate air pollutant concentrations in homes that result from cooking and the inflow of outdoor air, mediated by loss and removal process including deposition, dwelling unit ventilation, and the use of a range hood with varying levels of capture efficiency. Calculated pollutant concentrations are compared to relevant, health-based guidelines. The analysis considers the highest 1-hour concentration of nitrogen dioxide (NO 2 ), which is a product of natural gas combustion and the highest 24-hour concentrations of fine particulate matter (PM 2.5 ) which is emitted in substantial quantities from frying, broiling and grilling among other cooking activities. For NO 2 , the analysis considers cooking of a dinner for 3-4 persons consisting of pasta, meat sauce, a par-boiled vegetable, and baked garlic bread. For PM 2.5 , the analysis considers a day in which breakfast emitted particles at the 80th percentile and lunch and dinner entailed particle emissions at the 50th percentile of cooking emission events reported in the literature. Model simulations were performed to determine the level of range hood capture efficiency that will allow these cooking scenarios to occur in the vast majority (>99%) of new homes being built in California while maintaining pollutant concentrations below the health-based guidelines, if the range hood is used throughout cooking. All homes were assumed to have dwelling unit ventilation at the rate required in the building code. Simulation model input parameters were specified using a Monte Carlo approach to represent a range of housing characteristics, outdoor conditions, and indoor pollutant dynamics. Simulation results suggest that requiring a minimum capture efficiency of at least 70% is needed to avoid unacceptably high NO 2 (1-h average concentration of 100 ppb or higher) and at least 60% to avoid unacceptably high PM 2.5 (24-h average of 25 μg/m³ or higher). These results were driven by multi-family homes, which have a smaller volume of air to dilute any pollutants not captured and removed at the cooking area, resulting in higher concentrations.

54 ENVIRONMENTAL SCIENCES↗

Zeolite Membrane Reactor for Pre-Combustion Carbon Dioxide Capture

Water-gas shift (WGS) reaction followed by carbon dioxide (CO 2 ) separation is a critical step in the integrated gasification combined cycle (IGCC) process for fossil-fuel-fired electrical power generation with CO 2 capture. To intensify the IGCC process hydrogen-permselective zeolite membrane reactor offers promise to replace the conventional energy-intensive fixed-bed reactors and solvent-based CO 2 capture units. The objectives of this project were to develop a bench-scale zeolite membrane reactor (total membrane area: 932 cm 2 for a 21-tube membrane bundle) for the water-gas-shift reaction of raw syngas from an oxygen-blown coal-gasifier for H 2 production with simultaneous CO 2 separation at the capability of about 2 kilograms H 2 per day (equivalent to 2 kW IGCC power plant) and to demonstrate significant progress toward achieving overall performance goal of 90% CO 2 capture rate with 95% CO 2 purity at the cost of electricity 30% less than the baseline carbon capture approaches. This report summarizes results obtained in this project on scaling up the zeolite membrane reactor by a factor of 200 in membrane area, tests of the bench-scale zeolite membrane reactor for the water-gas-shift reaction at high temperature and high-pressure, and techno-economic analysis of the integration of the zeolite membrane reactor in IGCC power plant for the electrical generation with CO 2 capture.

20 FOSSIL-FUELED POWER PLANTS↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Demonstration and Validation of Additively Manufactured Intensified Device for Enhanced Carbon Capture

In FY 2018 and 2019, ORNL personnel designed, prototyped, characterized, and tested the enhancement of amine-based carbon capture using additively manufactured intensified devices, i.e., devices combining multiple thermodynamic and kinetic processes into one unit operation. State of the art scrubbing technology often employs inter-stage cooling which requires multiple stages of single-purpose unit operations, leading to larger equipment size, higher capital cost, and sometimes less than optimal operating conditions for each piece of equipment. It was proposed that integrating multiple thermodynamic and kinetic operations into one unit could mitigate or negate these drawbacks. Heat and mass transfer studies demonstrated that an additively manufactured intensified device could significantly improve capture efficiency at bench scale. This project is a continuation of FEAA130 and aims at (1) demonstration and validation of enhanced CO 2 capture with 3D printed intensified devices (i.e., mass exchanger packing with internal cooling channels), for low-aqueous-solvent (LAS) based capture at the ORNL-constructed laboratory-scale (4.5-feet tall) column, namely Column A, with built-in cooling and (2) computational scoping on the conceptual design of a flexible and modular larger column, namely Column B, at ORNL for further demonstration of enhanced capture for aqueous solvent. To execute this multi-faceted project scope, an integrated project team from ORNL’s Manufacturing Science Division is tasked with applying capabilities in computational fluid dynamics (CFD), additive manufacturing, and absorber-scale demonstration/validation experiments.

42 ENGINEERING↗

Performance Criteria for Capture and/or Immobilization Technologies (Revision 1)

The capture and subsequent immobilization of regulated volatile radionuclides from the off-gas streams of a used nuclear fuel (UNF) reprocessing facility has been a topic of substantial research interest for the US Department of Energy and its international counterparts. Removal of specific radionuclides from the plant effluent streams before discharge to the environment is required to meet regulations set forth by the US Environmental Protection Agency. Upon removal, the radionuclides, as well as associated sorbents that cannot be regenerated in a cost-effective manner, are destined for conversion to a waste form. Research in separation and capture methodologies has included a wide range of technology types, and studies of waste forms are correspondingly diverse. In considering the future development and implementation of both sorbents and waste forms, it is necessary to identify benchmark measures of performance to objectively evaluate each sorbent system or waste form. Sets of performance criteria and associated metrics have been developed for sorbent and waste form evaluation. These criteria address physical, radiological, and chemical characteristics, technical practicality, technical maturity, cost, and, for sorbents, system performance. The criteria and metrics appear to be robust and should be applicable despite the eventual waste classification (as either high- or low-level waste). They are flexible enough to address both aqueous reprocessing and electrochemical reprocessing of UNF. These criteria sets can serve as tools to evaluate performance at multiple stages within the development process, and in this revision (Revision 1) they have been used to assess technologies relating to krypton/xenon separations and iodine capture from off-gas streams arising from UNF reprocessing. Assessment of krypton/xenon separations using engineered forms of two zeolite minerals (silver mordenite and hydrogen mordenite in a polyacrylonitrile-based binder [AgZ-PAN/HZ-PAN]) found that the zeolite-based separation is relatively advanced in its development, but several key issues require resolution. First, desorption processes for both krypton and xenon require refinement to provide an understanding of the product purity that can be achieved. Second, adsorption rate data is needed in order to calculate the bed depth required for effective separation. Finally, it is strongly recommended that a technical review of krypton/xenon separation by AgZ-PAN/HZ-PAN be performed to synergize available data and assess the cost savings and operational benefits that may be realized from implementation of this technology. Assessment of metal organic frameworks (MOFs) for their use in the separation of krypton/xenon found that the ideal separation would be performed using a single-column system with a MOF selective for krypton over xenon. A robust research effort should work to identify a krypton-selective MOF designed to operate at temperatures of approximately 0°C or higher, which could be preferred over cryogenic krypton/xenon capture for used fuel reprocessing off-gas streams. In the case of the CaSDB-MOF (the most well-understood xenon sorbent to date), two issues are judged of high importance. First, xenon breakthrough capacity for the CaSDB-MOF in prototypical conditions should be determined. Preliminary research indicates that breakthrough may be near immediate, presenting a substantial obstacle in separative system design. Second, development of desorption methodology should be performed to determine regeneration time, energy requirements, and the product stream composition. Silver-based sorbents (AgZ and AgAero) for use in iodine capture from the dissolver off-gas were evaluated against the established criteria. These sorbents are significantly better understood for this application as a result of research efforts over the past decade. The potential implementation of AgAero at a large scale is hindered by its physical degradation by components of the dissolver off-gas stream. Less is known about the adsorption of iodine by these sorbents from other off-gas streams in the plant. Initial experimental efforts have been closely coordinated in an effort to understand organic iodine (such as would be found in the vessel off-gas) adsorption by AgZ and AgAero. Future work should expand this experimental program, and analysis of other reprocessing facility off-gas streams such as the vitrification off-gas stream should be conducted to better understand other potential applications for iodine sorbents. A review of iodine waste form development shows that this area is diverse and that multiple promising waste forms have been identified for the immobilization of radioactive iodine. Efforts related to the direct conversion of iodine sorbents (including AgZ and AgAero) should be continued because of the advantages of direct conversion in a waste management strategy and other sorbents should continue to be advanced as merited.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bituminous Coal and Natural Gas to Electricity: >90% Capture Cases Technical Note

This technical note provides cost and performance estimates for post combustion carbon capture (PCCC) systems designed for greater than 90 percent capture on conventional PC- and NG-fueled power plants. The cost and performance estimates provided here were developed using the National Energy Technology Laboratory’s (NETL’s) well-documented methodology for conducting technoeconomic analysis of fossil energy conversion systems and leveraging published performance and cost projections for higher capture rate systems. Included in this technical note is a brief description of the method used to adjust select 90 percent capture cases from NETL’s Cost and Performance Baselines for Fossil Energy Systems Volume 1: Bituminous Coal and Natural Gas to Electricity, hereafter referred to as the Baseline Study. This technical note is intended to serve as an interim update to NETL’s Baseline Study cases by providing cost and performance estimates for high capture PCCC technology that can be deployed in the near-term at fossil-fueled electricity generating units.

20 FOSSIL-FUELED POWER PLANTS↗

Front End Engineering Design of Linde-BASF Advanced Post-Combustion CO 2 Capture Technology at a Southern Company Natural Gas-Fired Power Plant (Final Scientific/Technical Report)

This document details the execution of Cooperative Agreement DE-FE0031847, “Front End Engineering Design of Linde-BASF Advanced Post-Combustion Carbon Dioxide (CO 2 ) Capture Technology at a Southern Company Natural Gas-Fired Power Plant” during the period of 10/1/2019 to 6/30/2022. The project was funded by the U.S. Department of Energy’s Office of Fossil Energy and Carbon Management (FECM) and managed by the National Energy Technology Laboratory (NETL). Southern Company Services, Inc. (SCS) was the prime recipient and led the project team. Other members of the project team included Linde, Inc. (Linde), Linde Engineering – Dresden (LED), and BASF. The overall goal of the project was to complete a front-end engineering design (FEED) study for installing the Linde-BASF post-combustion capture (PCC) technology at an existing domestic natural gas-fired combined cycle (NGCC) power plant within Southern Company’s portfolio of assets. The CO 2 capture plant was to be of commercial scale (at least 375 MWe) and include process units for pre-conditioning of the flue gas system, the CO 2 capture plant island, storage vessels, the CO 2 compression train, and any necessary components for integration into the NGCC plant. Mississippi Power’s Plant Daniel Unit #4 was chosen as the host site for the FEED with the target of capturing 90% of CO 2 emissions from the existing combustion turbines. The information produced by the FEED was used to develop a cost estimate of +/- 15% accuracy. Capital costs, excluding financing, are estimated at approximately $\$752$ million dollars (2021). The execution of a project based on this FEED study has an estimated duration of almost five years.

03 NATURAL GAS↗