Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

How to constrain your M dwarf: Measuring effective temperature, bolometric luminosity, mass, and radius

Precise and accurate parameters for late-type (late K and M) dwarf stars are important for characterization of any orbiting planets, but such determinations have been hampered by these stars’ complex spectra and dissimilarity to the Sun. We exploit an empirically calibrated method to estimate spectroscopic effective temperature (T{sub eff}) and the Stefan–Boltzmann law to determine radii of 183 nearby K7–M7 single stars with a precision of 2%–5%. Our improved stellar parameters enable us to develop model-independent relations between T{sub eff} or absolute magnitude and radius, as well as between color and T{sub eff}. The derived T{sub eff}–radius relation depends strongly on [Fe/H], as predicted by theory. The relation between absolute K{sub S} magnitude and radius can predict radii accurate to ≃3%. We derive bolometric corrections to the VR{sub C}I{sub C}grizJHK{sub S} and Gaia passbands as a function of color, accurate to 1%–3%. We confront the reliability of predictions from Dartmouth stellar evolution models using a Markov chain Monte Carlo to find the values of unobservable model parameters (mass, age) that best reproduce the observed effective temperature and bolometric flux while satisfying constraints on distance and metallicity as Bayesian priors. With the inferred masses we derive a semi-empirical mass–absolute magnitude relation with a scatter of 2% in mass. The best-agreement models overpredict stellar T{sub eff} values by an average of 2.2% and underpredict stellar radii by 4.6%, similar to differences with values from low-mass eclipsing binaries. These differences are not correlated with metallicity, mass, or indicators of activity, suggesting issues with the underlying model assumptions, e.g., opacities or convective mixing length.

79 ASTRONOMY AND ASTROPHYSICS↗

IMPROVED Ti II log(gf) VALUES AND ABUNDANCE DETERMINATIONS IN THE PHOTOSPHERES OF THE SUN AND METAL-POOR STAR HD 84937

Atomic transition probability measurements for 364 lines of Ti II in the UV through near-IR are reported. Branching fractions from data recorded using a Fourier transform spectrometer (FTS) and a new echelle spectrometer are combined with published radiative lifetimes to determine these transition probabilities. The new results are in generally good agreement with previously reported FTS measurements. Use of the new echelle spectrometer, independent radiometric calibration methods, and independent data analysis routines enables a reduction of systematic errors and overall improvement in transition probability accuracy over previous measurements. The new Ti II data are applied to high-resolution visible and UV spectra of the Sun and metal-poor star HD 84937 to derive new, more accurate Ti abundances. Lines covering a range of wavelength and excitation potential are used to search for non-LTE effects. The Ti abundances derived using Ti II for these two stars match those derived using Ti I and support the relative Ti/Fe abundance ratio versus metallicity seen in previous studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Hierarchical top-down bottom-up calibration with consideration for uncertainty and inter-scale discrepancy of Peierls stress of bcc Fe

A hierarchical multiscale model of plasticity in single crystal bcc Fe, framed at the mesoscale pertaining to a statistically representative set of dislocations for each slip system, relies on specification of a set of parameters which are informed using both bottom-up (BU) (atomistic) and top-down (TD) (experimental) information. We term this specification process a 'connection' between BU and TD pathways to inform the mesoscale model. The connection is considered in the presence of error, uncertainty, and discrepancy between the models. Furthermore, we expand upon a previously developed reconciled TD and BU calibration method to account for anticipated discrepancy between information from different length scales. The results of a previously formulated likelihood-based connection test of the multiscale model suggest a 'missing link' may be responsible for part of the inter-scale discrepancy. In this case, this link is assumed to be a relation between the unit-process (single dislocation line) of coordinated kink-pair nucleation on a screw dislocation segment and the many-body dislocation process which manifests in the onset of experimentally observed plastic deformation in a single crystal. A physics-informed discrepancy layer is formulated to improve the connection in the presence of additional persistent uncertainties. This physics-informed hypothesis testing is demonstrated as an alternative to fully data-driven search methods, particularly applicable to datasets of limited size that are often encountered in such multiscale material modeling applications. Discrete dislocation dynamics simulations are used to investigate the effect of the Peierls stress on straight screw dislocations and in the operation of Frank–Read sources. Discussion concerns the critical role of uncertainty quantification in providing a basis for this form of incremental hypothesis testing.

42 ENGINEERING↗

Coherent microwave scattering from resonance enhanced multi-photon ionization (Radar REMPI): A review

Coherent microwave scattering from laser-induced plasmas, including weakly ionized plasma, laser sparks, Multiphoton Ionization (MPI), and Resonance Enhanced Multi-Photon Ionizations (Radar REMPI) has achieved much successes in plasma, reactive and nonreactive flow diagnostics. Under illumination of microwaves (Radar), electrons inside the laser-induced plasma oscillate with the electric field of the microwave and re-radiate from the electrons forming coherent scattering. In the far-field approximation, the microwave scattering from the small volume plasma reflects the generation and evolution of unbounded electrons inside the plasma, when the microwave wavelength is much greater than the size of the plasma and the skin layer depth at the microwave frequency is larger than the size of the plasma. Laser excitation schemes, microwave detection methods, calibration of microwave scattering, and the novel applications of the technique have been significantly expanded and improved. Furthermore, this review paper summarizes physical principles, various REMPI excitation schemes for atomic and molecular species, and temperature measurements in plasma and reactive flows. Discussions on new research directions and applications are given at the end.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗

The DEHVILS survey overview and initial data release: high-quality near-infrared Type Ia supernova light curves at low redshift

ABSTRACT While the sample of optical Type Ia supernova (SN Ia) light curves (LCs) usable for cosmological parameter measurements surpasses 2000, the sample of published, cosmologically viable near-infrared (NIR) SN Ia LCs, which have been shown to be good ‘standard candles,’ is still ≲ 200. Here, we present high-quality NIR LCs for 83 SNe Ia ranging from 0.002 < z < 0.09 as a part of the Dark Energy, H0, and peculiar Velocities using Infrared Light from Supernovae (DEHVILS) survey. Observations are taken using UKIRT’s WFCAM, where the median depth of the images is 20.7, 20.1, and 19.3 mag (Vega) for Y, J, and H-bands, respectively. The median number of epochs per SN Ia is 18 for all three bands (Y,J, and H) combined and 6 for each band individually. We fit 47 SN Ia LCs that pass strict quality cuts using three LC models, SALT3, snoopy, and B ayeSN and find scatter on the Hubble diagram to be comparable to or better than scatter from optical-only fits in the literature. Fitting NIR-only LCs, we obtain standard deviations ranging from 0.128 to 0.135 mag. Additionally, we present a refined calibration method for transforming 2MASS magnitudes to WFCAM magnitudes using HST CALSPEC stars that results in a 0.03 mag shift in the WFCAM Y-band magnitudes.

Astronomy & Astrophysics↗

Opacities of singly and doubly ionized neodymium and uranium for kilonova emission modeling

ABSTRACT Even though the electromagnetic counterpart AT2017gfo to the binary neutron star merger GW170817 is powered by the radioactive decay of r-process nuclei, only few tentative identifications of light r-process elements have been made so far. One of the major limitations for the identification of heavy nuclei is incomplete or missing atomic data. While substantial progress has been made on lanthanide atomic data over the last few years, for actinides there has been less emphasis, with the first complete set of opacity data only recently published. We perform atomic structure calculations of neodymium (Z = 60) as well as the corresponding actinide uranium (Z = 92). Using two different codes [flexible atomic code (fac) and hartree–fock-relativistic (hfr)] for the calculation of the atomic data, we investigate the accuracy of the calculated data (energy levels and electric dipole transitions) and their effect on kilonova opacities. For the fac calculations, we optimize the local central potential and the number of included configurations and use a dedicated calibration technique to improve the agreement between theoretical and available experimental atomic energy levels (AELs). For ions with vast amounts of experimental data available, the presented opacities agree quite well with previous estimations. On the other hand, the optimization and calibration method cannot be used for ions with only few available AELs. For these cases, where no experimental nor benchmarked calculations are available, a large spread in the opacities estimated from the atomic data obtained with the various atomic structure codes is observed. We find that the opacity of uranium is almost double the neodymium opacity.

Flörs, A. (ORCID:0000000320242819)↗

Study of the normalized transverse momentum distribution of W bosons produced in $p\bar{p}$ collisions at $\sqrt{s}$ = 1.96 TeV

We present a study of the normalized transverse momentum distribution of W bosons produced in $p\bar{p}$ collisions, using data corresponding to an integrated luminosity of 4.35 fb -1 collected with the D0 detector at the Fermilab Tevatron collider at $\sqrt{s}$ = 1.96 TeV. The measurement focuses on the transverse momentum region below 15 GeV, which is of special interest for electroweak precision measurements; it relies on the same detector calibration methods which were used for the precision measurement of the W boson mass. The measured distribution is compared to different QCD predictions and a procedure is given to allow the comparison of any further theoretical models to the D0 data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark Energy Survey Year 1 Results: Cosmological Constraints from Cosmic Shear

Here, we use 26 million galaxies from the Dark Energy Survey (DES) Year 1 shape catalogs over 1321 deg 2 of the sky to produce the most significant measurement of cosmic shear in a galaxy survey to date. We constrain cosmological parameters in both the flat CDM and wCDM models, while also varying the neutrino mass density. These results are shown to be robust using two independent shape catalogs, two independent photo- z calibration methods, and two independent analysis pipelines in a blind analysis. We find a 3% fractional uncertainty on σ 8 ( Ω m =0.3)0.5 = 0.789$+0.024\atop{0.026}$ at 68% CL, which is a factor of three improvement over the fractional constraining power of our DES Science Verification results and a factor 1.5 tighter than the previous state-of-the-art cosmic shear results. In wCDM, we find a 5% fractional uncertainty on 8( m=0:3)0:5 = 0.789$+0.036\atop{0.038}$ and a dark energy equation-of-state w = -0.82$+0.26\atop{-0.48}$. Though we find results that are consistent with previous cosmic shear constraints in 8 – m, we nevertheless see no evidence for disagreement of our weak lensing data with data from the CMB. Finally, we find no evidence preferring a wCDM model allowing w≠ -1. Finally, we expect further significant improvements with subsequent years of DES data, which will more than triple the sky coverage of our shape catalogs and double the effective integrated exposure time per galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Behavioral and Population Data-Driven Distribution System Load Modeling

Distribution system residential load modeling and analysis for different geographic areas within a utility or an independent system operator territory are critical for enabling small-scale, aggregated distributed energy resources to participate in grid services under Federal Energy Regulatory Commission Order No. 2222 [1]. In this study, we develop a methodology of modeling residential load profiles in different geographic areas with a focus on human behavior impact. First, we construct a behavior-based load profile model leveraging state-of-the-art appliance models. We simulate human activity and occupancy using Markov chain Monte Carlo methods calibrated with the American Time Use Survey data set. Second, we link our model with cleaned Current Population Survey data from the U.S. Census Bureau. Finally, we populate two sets of 500 households using California and Texas census data, respectively, to perform an initial analysis of the load in different geographic areas with various group features (e.g., different income levels). To distinguish the effect of population behavior differences on aggregated load, we simulate load profiles for both sets assuming fixed physical household parameters and weather data. Analysis shows that average daily load profiles vary significantly by income and income dependency varies by locality.

American Time Use Survey↗

Comparison of Thin Film Heat Flux Gauge Technologies Emphasizing Continuous-Duration Operation

Abstract Thin-film heat flux gauges (HFGs) have been used for decades to measure surface temperatures and heat flux in test turbines with the majority being used in facilities that are short-duration. These gauges are typically composed of two resistive temperature devices deposited on opposing sides of a dielectric. However, because these sensors have been traditionally applied for measurements in transient-type facilities, the challenges facing adaptation of this technology for a steady facility warrant investigation. These challenges are highlighted, and the solutions are presented throughout the paper. This paper describes the nanofabrication process for heat flux gauges and a new calibration method to address the potential deterioration of gauges over long runtimes in continuous-duration facilities. Because the primary uncertainty of these sensors arises from the ambiguity of the thermal properties, the emphasis is placed on the property determination. Also, this paper presents a discussion on the use of impulse response theory to process the data showing the feasibility of the method for steady-duration facilities after an initial settling time. The latter portion of the paper focuses on comparing well-established heat flux gauges developed for short-duration turbine test facilities to recently developed gauges fabricated using modern nanofabrication techniques for a continuous turbine test facility. The gauges were compared using the test case of an impinging jet over a range of Reynolds numbers. The comparison between the PSU gauge and the reference device indicated agreement within 14%, and similar results were achieved through comparison with established sensors from partner institutions.

Engineering↗

Comparison of Thin Film Heat Flux Gauge Technologies Emphasizing Continuous-Duration Operation

Thin film heat flux gauges (HFGs) have been used for several decades to measure surface temperatures and heat flux in test turbines with the majority being used in facilities that are short-duration. These gauges are typically composed of two resistive temperature devices deposited on opposing sides of a dielectric. However, because these sensors have been traditionally applied for measurements in short-duration, transient-type facilities, the challenges facing adaptation of this technology for a continuous-duration steady facility warrant investigation. Those challenges are highlighted, and solutions are presented throughout the paper. This paper describes the nanofabrication process for heat flux gauges and a new calibration method to address potential deterioration of gauges over long runtimes in continuous-duration facilities. Because a primary uncertainty of these sensors arises from the ambiguity of the thermal properties, special emphasis is placed on the property determination and potential errors due to improper thermal properties. Also, this paper presents a discussion on the use of impulse response theory to process the data showing the feasibility of the method for steady-duration facilities after an initial settling time. The latter portion of the paper focuses on comparing well-established heat flux gauges developed for short-duration turbine test facilities to recently developed gauges fabricated using modern nanofabrication techniques for a continuous turbine test facility. Using a commercially available heat flux gauge, capable of measuring a steady heat flux as a reference, the gauges were compared using the test case of an impinging jet over a range of Reynolds numbers. The comparison between the PSU gauge and the reference device indicated agreement within 14%, and similar results were achieved through comparison with established sensors from partner institutions.

20 FOSSIL-FUELED POWER PLANTS↗

Sci—Thur PM: Imaging — 05: Calibration of a SPECT/CT camera for quantitative SPECT with {sup 99m}Tc

While quantitation is the norm in PET, it is not widely available yet in SPECT. This work's aim was to calibrate a commercially available SPECT/CT system to perform quantitative SPECT. Counting sensitivity, dead-time (DT) constant and partial volume effect (PVE) of the system were assessed. A dual-head Siemens SymbiaT6 SPECT/CT camera equipped with low energy high-resolution collimators was studied. {sup 99m}Tc was the radioisotope of interest because of its wide usage in nuclear medicine. First, point source acquisitions were performed (activity: 30–990MBq). Further acquisitions were then performed with a uniform Jaszczak phantom filled with water at high activity (25–5000MBq). PVE was studied using 6 hot spheres (diameters: 9.9–31.2 mm) filled with {sup 99m}Tc (2.8MBq/cc) in the Jaszczak phantom, which was: (1) empty, (2) water-filled and (3) water-filled with low activity (0.1MBq/cc). The data was reconstructed with the Siemens's Flash3D iterative algorithm with 4 subsets and 8 iterations, attenuation-correction (AC) and scatter-correction (SC). DT modelling was based on the total spectrum counting rate. Sensitivity was assessed using AC-SC reconstructed SPECT data. Sensitivity and DT for the sources were 99.51±1.46cps/MBq and 0.60±0.04µs. For the phantom, sensitivity and DT were 109.9±2.3cps/MBq and 0.62±0.13µs. The recovery-coefficient varied from 5% for the 9.9mm, to 80% for the 31.2mm spheres. With our calibration methods, both sensitivity and DT constant of the SPECT camera had little dependence on the object geometry and attenuation. For small objects of known size, recovery-coefficient can be applied to correct PVE. Clinical quantitative SPECT appears to be possible and has many potential applications.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-665: Radiochromic Film Quenching Effect Reduction for Proton Beam Dosimetry

Purpose: Depending on the useful dose range in which radiochromic films operate, number of different radiochromic film models have been designed. The impact of different film models on quenching effect for percent depth dose (PDD) measurements in proton beams has been investigated. Methods: Calibrated PTW Markus ionization chamber was used to measure PDD and beam output for 26.5 MeV protons produced by CS30 cyclotron. An aluminum cylinder was added in front of the beam exit serving as a radiation shutter. The measured signal was normalized to a monitor chamber reading and subsequently scaled by ratio of water-to-air stopping powers at given depth, while the effective depth of measurements was scaled by ratios of material-to-water physical densities and CSDA ranges. Output was measured in water at 2.1 mm reference-depth in the plateau upstream from the Bragg peak. Following the TRS-398 reference dosimetry protocol for proton beams, the output was calibrated in water. Three radiochromic film models (EBT, EBT3 and HD-V2) were calibrated within Lexan phantom positioned at the same water-equivalent depth. Thicknesses of films sensitive layers were 34 µm, 30 µm and 8 µm, respectively. Small film pieces (1 x 2 cm{sup 2}) were positioned within polyethylene phantom along the beam central axis with an angulation of 5° for PDD measurements. Results: While the output of the proton beam was found to be around 7 Gy/sec, the actual value of the output per monitor chamber reading (2.32 Gy/nC) was used for reference-dose irradiations during film calibration. Dose ratios at the Bragg peak relative to the reference-depth were 3.88, 2.52, 2.19, and 2.02 for the Markus chamber, HD-V2, EBT3, and EBT film models, respectively. Conclusion: Results at hand suggest that quenching effect is reduced when a radiochromic film model with smaller sensitive layer thickness is used for PDD measurements in proton beams. David Lewis is the owner of RCF Consulting, LLC.

07 ISOTOPE AND RADIATION SOURCES↗

Bone-marrow densitometry: Assessment of marrow space of human vertebrae by single energy high resolution-quantitative computed tomography

Purpose: Accurate noninvasive assessment of vertebral bone marrow fat fraction is important for diagnostic assessment of a variety of disorders and therapies known to affect marrow composition. Moreover, it provides a means to correct fat-induced bias of single energy quantitative computed tomography (QCT) based bone mineral density (BMD) measurements. The authors developed new segmentation and calibration methods to obtain quantitative surrogate measures of marrow-fat density in the axial skeleton. Methods: The authors developed and tested two high resolution-QCT (HR-QCT) based methods which permit segmentation of bone voids in between trabeculae hypothesizing that they are representative of bone marrow space. The methods permit calculation of marrow content in units of mineral equivalent marrow density (MeMD). The first method is based on global thresholding and peeling (GTP) to define a volume of interest away from the transition between trabecular bone and marrow. The second method, morphological filtering (MF), uses spherical elements of different radii (0.1–1.2 mm) and automatically places them in between trabeculae to identify regions with large trabecular interspace, the bone-void space. To determine their performance, data were compared ex vivo to high-resolution peripheral CT (HR-pQCT) images as the gold-standard. The performance of the methods was tested on a set of excised human vertebrae with intact bone marrow tissue representative of an elderly population with low BMD. Results: 86% (GTP) and 87% (MF) of the voxels identified as true marrow space on HR-pQCT images were correctly identified on HR-QCT images and thus these volumes of interest can be considered to be representative of true marrow space. Within this volume, MeMD was estimated with residual errors of 4.8 mg/cm{sup 3} corresponding to accuracy errors in fat fraction on the order of 5% both for GTP and MF methods. Conclusions: The GTP and MF methods on HR-QCT images permit noninvasive localization and densitometric assessment of marrow fat with residual accuracy errors sufficient to study disorders and therapies known to affect bone marrow composition. Additionally, the methods can be used to correct BMD for fat induced bias. Application and testing in vivo and in longitudinal studies are warranted to determine the clinical performance and value of these methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-174: Patient-Specific Point Dose Measurement Using Fiber Optic Radiation Sensor Using Cerenkov Radiation for Proton Therapeutic Beam

Purpose: A fiber-optic radiation sensor using Cerenkov radiation (FOCR) has been widely studied for use as a dosimeter for proton therapeutic beam. We developed the FOCR, and it applied to patient-specific point dose measurement in order to evaluate the effectiveness of the FOCR system for proton therapy QA. Methods: Calibration of FOCR was performed with an ionization chamber whose absolute doses were determined according to the IAEA TRS-398 protocol. To determine the calibration curve, the FOCR was irradiated perpendicularly to the proton beam at the 13 dose levels steps. We selected five actual patient treatment plans performed at proton therapy center and compared the resulting FOCR measurements with the ionization chamber measurements. Results: The Cerenkov light yield of the FOCR increases linearly with as the dose measured using the ionization chamber increases from 0 cGy to 500 cGy. The results indicate that the fitting curve is linear, suggesting that dose measurement based on the light yield of the FOCR is possible. The results of proton radiation dose QA performed using the FOCR for 10 proton fields and five patients are good agreement with an ionization chamber. Conclusion: We carried out the patient QA using the FOCR for proton therapeutic beam and evaluated the effectiveness of the FOCR as a proton therapy QA tool. Our results indicate that the FOCR is suitable for use in patient QA of clinical proton beams.

60 APPLIED LIFE SCIENCES↗

Operation and performance of the ATLAS tile calorimeter in LHC Run 2

The ATLAS tile calorimeter (TileCal) is the hadronic sampling calorimeter covering the central region of the ATLAS detector at the Large Hadron Collider (LHC). This paper gives an overview of the calorimeter’s operation and performance during the years 2015–2018 (Run 2). In this period, ATLAS collected proton–proton collision data at a centre-of-mass energy of 13 TeV and the TileCal was 99.65% efficient for data-taking. The signal reconstruction, the calibration procedures, and the detector operational status are presented. The performance of two ATLAS trigger systems making use of TileCal information, the minimum-bias trigger scintillators and the tile muon trigger, is discussed. Studies of radiation effects allow the degradation of the output signals at the end of the LHC and HL-LHC operations to be estimated. Finally, the TileCal response to isolated muons, hadrons and jets from proton–proton collisions is presented. The energy and time calibration methods performed excellently, resulting in good stability and uniformity of the calorimeter response during Run 2. The setting of the energy scale was performed with an uncertainty of 2%. The results demonstrate that the performance is in accordance with specifications defined in the Technical Design Report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of IR imaging for free-surface velocity measurement in liquid-metal systems

Measuring free-surface, liquid-metal flow velocity is challenging to do in a reliable and accurate manner. This paper presents a non-invasive, easily-calibrated method of measuring the surface velocities of open-channel liquid-metal flows using an IR camera. Unlike other spatially-limited methods, this IR camera particle tracking technique provides full field-of-view data that can be used to better understand open-channel flows and determine surface boundary conditions. This method could be implemented and automated for a wide range of liquid-metal experiments, even if they operate at high-temperatures or within strong magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗