Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

building-physics/refrigeration-system

The existing refrigeration system for OpenStudio was originally designed for a prototype supermarket model. To support the development of new modular space types, it is crucial to refactor the system. This process includes refining the design by utilizing the manufacturer's existing data, along with incorporating the latest data from manufacturers, to enhance the system’s adaptability and functionality. This repository currently contains the refrigeration system database and Python-based automation for generating OpenStudio-compatible refrigeration JSON files.

Bae, Yeonjin [Oak Ridge National Laboratory (ORNL)↗

Low Carbon Technology Strategies: Large Office

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon large office buildings within their existing building portfolios. Large offices are typically over 50,000 square feet and often include complex heating and cooling systems.

analytics↗

Low Carbon Technology Strategies: Small Office

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon small office buildings within their existing building portfolios. Small offices are typically less than 50,000 square feet and often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Midrise Apartment

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon midrise apartment buildings within their existing building portfolios. Midrise apartments may use packaged rooftop units for heating, cooling, and ventilation or central plant systems for larger buildings.

analytics↗

Low Carbon Technology Strategies: Secondary School

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon secondary schools within their existing building portfolios. Secondary schools often include complex heating and cooling systems or packaged rooftop units and can include specialty equipment for gymnasiums, pools, and buses.

analytics↗

Low Carbon Technology Strategies: Primary School

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon primary schools within their existing building portfolios. Primary schools often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Outpatient Healthcare

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon outpatient healthcare buildings within their existing building portfolios. Outpatient healthcare includes diagnostic and treatment facilities for outpatient care, and these buildings often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Low Carbon Technology Strategies: Small Hotel

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon small hotels within their existing building portfolios. Small hotels are typically four floors or less and less than 50,000 square feet and often use packaged rooftop units for heating, cooling, and ventilation.

analytics↗

Design and Implementation of Smart Buildings: A Review of Current Research Trend

The building sector is one of the largest contributors to the world’s total energy use and greenhouse gas emissions. Advancements in building energy technologies have played a critical role in enhancing the energy sustainability of the built environment. Extensive research and new techniques in energy and environmental systems for buildings have recently emerged to address the global challenges. This study reviews existing articles in the literature, mostly since 2000, to explore technological advancement in building energy and environmental systems that can be applied to smart homes and buildings. This review study focuses on an overview of the design and implementation of energy-related smart building technologies, including energy management systems, renewable energy applications, and current advanced smart technologies for optimal function and energy-efficient performance. To review the advancement in building energy-related technologies, a systematic review process is adopted based on available published reviews and research types of articles. Review-type articles are first assessed to explore the current literature on the relevant keywords and to capture major research scopes. Research-type papers are then examined to investigate associated keywords and work scopes, including objectives, focuses, limitations, and future needs. Throughout the comprehensive literature review, this study identifies various techniques of smart home/building applications that have provided detailed solutions or guidelines in different applications to enhance the quality of people’s daily activities and the sustainability of the built environmental system. This paper shows trends in human activities and technology advancements in digital solutions with energy management systems and practical designs. Understanding the overall energy flow between a building and its environmentally connected systems is also important for future buildings and community levels. This paper assists in understanding the pathway toward future smart homes/buildings and their technologies for researchers in related research fields.

renewable system integration↗

Towards a Semantically-Enabled Control Strategy for Building Simulations: Integration of Semantic Technologies and Model Predictive Control

State-of-the-art building simulation control methods incorporate physical constraints into their mathematical models, but omit implicit constraints associated with policies of operation and dependency relationships among rules representing those constraints. To overcome these shortcomings, there is a recent trend in enabling the control strategies with inference-based rule checking capabilities. One solution is to exploit semantic web technologies in building simulation control. Such approaches provide the tools for semantic modeling of domains, and the ability to deduce new information based on the models through use of Description Logic (DL). In a step toward enabling this capability, this paper presents a cross-disciplinary data-driven control strategy for building energy management simulation that integrates semantic modeling and formal rule checking mechanisms into a Model Predictive Control (MPC) formulation. The results show that MPC provides superior levels of performance when initial conditions and inputs are derived from inference-based rules.

Delgoshaei, Parastoo↗

A Comprehensive Review of Working Fluids for High-Temperature Heat Pumps: History, Selection, and Evaluation

High-temperature heat pumps (HTHPs) are essential for enhancing energy efficiency across various industrial applications, especially in terms of integrating with renewable energy sources and recovering waste heat. This article thoroughly investigates suitable working fluids for HTHPs, highlighting the evolution from traditional refrigerants to contemporary alternatives with low global warming potential (GWP). It proposes comprehensive selection criteria for these working fluids, pre-selects low-GWP working fluids, and outlines a screening methodology. The pre-selected low-GWP working fluids are evaluated for applications in three typical industrial scenarios involving HTHPs. Furthermore, this study demonstrates that regulatory compliance and environmental impacts significantly influence the development of next-generation refrigerants. The choice of working fluids is closely linked to the types of vapor compression cycles, tailored to the specific industrial applications for HTHPs. This study emphasizes areas for future research, including the development of innovative working fluids; integrated strategies that account for performance, safety, and regulatory standards; alignment of HTHP components; exploration of natural working fluids; and broadening the applications of existing working fluids.

Compression↗

A Toolbox Necessity: Finding Best Practices in High-Performance Homes with the Building America Solution Center

The U.S. Department of Energy’s Building America Solution Center is a free, easy-to-access web tool containing the latest building science research from the Building America program. This paper describes how the Solution Center is bringing best practices for high-performance homes to members of the building industry to help their businesses to gain an edge to help expand their markets. It includes a tour of the Solution Center’s newest features and updates. The Building America Solution Center provides full and simple access to a wealth of best practices based on building science and energy efficiency research generated by the Building America program, along with other resources to help builders specify features, train crews, complete quality installations, and sell houses. This paper supports the visual presentation with the same title. The paper will be submitted for inclusion in the ACEEE Summer Study 2018 proceedings. The poster will be presented at the ACEEE 2018 Summer Study conference.

.S. Department of Energy Building Technologies Pro↗

Transforming Buildings Around the World

Buildings are where we live, work, go to school, gather as a community, and so much more. Globally, buildings are responsible for 30% of energy consumption and 26% of energy-related emissions. The National Renewable Energy Laboratory (NREL) is committed to adapting tools and capabilities to support emerging economies and improve the energy efficiency and flexibility of their buildings.

building technology innovation↗

Oak Ridge D and D Plan 3515 Project - Technology Review (2007) and GammaCam Technology Demonstration for Characterizing Building 3515 at Oak Ridge (2007)

This paper presents the results from the Characterization, Decontamination and Decommissioning (CD and D) Study performed by MSE Technology Application, Inc. (MSE) to assist the U.S. Department of Energy (DOE) and Oak Ridge National Laboratory (ORNL) in the preparation of a Project Execution Plan and Remediation Plan for Building 3515 at ORNL. Primary objectives of this study were to identify innovative CD and D technologies and methodologies and recommend alternatives applicable to the CD and D of Building 3515. Building 3515 is a small heavily shielded concrete and cement block structure centrally located in the Bethel Valley portion of the ORNL. The building's interior is extensively contaminated with Cesium 137 (Cs-137), the primary contaminant of concern. A previous attempt to characterize the building was limited to general interior area radiation exposure level measurements and a few surface smears gathered by inserting monitoring equipment into the building on long poles. Consequently, the spatial distribution of the gamma radiation source inside the building was not determined. A subsequent plan for D and D of the building presented a high risk of worker radiation dose in excess of as low as reasonably achievable (ALARA) because the source of the interior gamma radiation field is not completely understood and conventional practices required workers to be in close proximity of the building. As part of an initial literature search, MSE reviewed new generation gamma source characterization technologies and identified the GammaCam{sup TM} portable gamma ray imaging system as an innovative technology applicable to locating the dominant gamma ray sources within the building. The GammaCam{sup TM} gamma-ray imaging system is a commercially available technology marketed by the EDO Corporation. This system consists of a sensor head with a co-aligned camera and a portable computer. The system is designed to provide two-dimensional spatial mappings of gamma ray emitting nuclides in real time. The gamma radiation sensor and camera can be set up within or outside of the radiation field while the system operator and PC can be located 30 to 60 m (100 to 200 ft) from the sensor head. The system has been used successfully at numerous DOE and commercial nuclear facilities to precisely locate gamma radiation sources. However, literature attesting to the ability of this technology to detect radiation sources within heavily shielded structures was not available. Consequently, MSE was not certain if this technology would be capable of locating gamma ray sources within the heavily shielded Building 3515. To overcome this uncertainty, MSE sent two individuals to the EDO Corporation for training. At completion of the training, MSE leased the GammaCam{sup TM} portable system and brought it to ORNL to evaluate the capability of the system. An overview from this evaluation is summarized in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Findings from an Analysis of Building Energy Information System Technologies

Energy information systems comprise software, data acquisition hardware, and communication systems that are intended to provide energy information to building energy and facilities managers, financial managers, and utilities. This technology has been commercially available for over a decade, however recent advances in Internet and other information technology, and analytical features have expanded the number of product options that are available. For example, features such as green house gas tracking, configurable energy analyses and enhanced interoperability are becoming increasingly common. Energy information systems are used in a variety of commercial buildings operations and environments, and can be characterized in a number of ways. Basic elements of these systems include web-based energy monitoring, web-based energy management linked to controls, demand response, and enterprise energy management applications. However the sheer number and variety of available systems complicate the selection of products to match the needs of a given user. In response, a framework was developed to define the capabilities of different types of energy information systems, and was applied to characterize approximately 30 technologies. Measurement is a critical component in managing energy consumption and energy information must be shared at all organizational levels to maintain persistent, efficient operations. Energy information systems are important to understand because they offer the analytical support to process measured data into information, and they provide the informational link between the primary actors who impact building energy efficiency - operators, facilities and energy managers, owners and corporate decision makers. In this paper, preliminary findings are presented, with a focus on overall trends and the general state of the technology. Key conclusions include the need to further pursue standardization and usability, x-y plotting as an under-supported feature, and a general convergence of visualization and display capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Broad Overview of Energy Efficiency and Renewable Energy Opportunities for Department of Defense Installations

The Strategic Environmental Research and Developmental Program (SERDP)/Environmental Security Technology Certification Program (ESTCP) is the Department of Defense?s (DOD) environmental science and technology program focusing on issues related to environment and energy for the military services. The SERDP/ESTCP Office requested that the National Renewable Energy Laboratory (NREL) providetechnical assistance with strategic planning by evaluating the potential for several types of renewable energy technologies at DOD installations. NREL was tasked to provide technical expertise and strategic advice for the feasibility of geothermal resources, waste-to-energy technology, photovoltaics (PV), wind, microgrids, and building system technologies on military installations. Thistechnical report is the deliverable for these tasks.

14 SOLAR ENERGY↗

Energy Demands and Efficiency Strategies in Data Center Buildings

Information technology (IT) is becoming increasingly pervasive throughout society as more data is digitally processed, stored, and transferred. The infrastructure that supports IT activity is growing accordingly, and data center energy demands haveincreased by nearly a factor of four over the past decade. Data centers house IT equipment and require significantly more energy to operate per unit floor area thanconventional buildings. The economic and environmental ramifications of continued data center growth motivate the need to explore energy-efficient methods to operate these buildings. A substantial portion of data center energy use is dedicated to removing the heat that is generated by the IT equipment. Using economizers to introduce large airflow rates of outside air during favorable weather could substantially reduce the energy consumption of data center cooling. Cooling buildings with economizers is an established energy saving measure, but in data centers this strategy is not widely used, partly owing to concerns that the large airflow rates would lead to increased indoor levels of airborne particles, which could damage IT equipment. The environmental conditions typical of data centers and the associated potential for equipment failure, however, are not well characterized. This barrier to economizer implementation illustrates the general relationship between energy use and indoor air quality in building design and operation. This dissertation investigates how building design and operation influence energy use and indoor air quality in data centers and provides strategies to improve both design goals simultaneously.As an initial step toward understanding data center air quality, measurements of particle concentrations were made at multiple operating northern California data centers. Ratios of measured particle concentrations in conventional data centers to the corresponding outside concentrations were significantly lower than those reported in the literature for office or residential buildings. Estimates using a material-balance model match well with empirical results, indicating that the dominant particle sources and losses -- ventilation and filtration -- have been characterized. Measurements taken at a data center using economizers show nearly an order of magnitude increase in particle concentration during economizer activity. However, even with the increase, themeasured particle concentrations are still below concentration limits recommended in most industry standards. The research proceeds by exploring the feasibility of using economizers in data centers while simultaneously controlling particle concentrations with high-quality air filtration. Physical and chemical properties of indoor and outdoor particles were analyzed at a data center using economizers and varying levels of air filtration efficiency. Results show that when improved filtration is used in combination with an economizer, the indoor/outdoor concentration ratios for most measured particle types were similar to the measurements when using conventional filtration without economizers. An energy analysis of the data center reveals that, even during the summer months, chiller savings from economizer use greatly outweigh the increase in fan power associated with improved filtration. These findings indicate that economizer use combined with improved filtration couldsignificantly reduce data center energy demand while providing a level of protection from particles of outdoor origin similar to that observed with conventional design. The emphasis of the dissertation then shifts to evaluate the energy benefits of economizer use in data centers under different design strategies. Economizer use with high ventilation rates is compared against an alternative, water-side economizer design that does not affect indoor particle concentrations. Building energy models are employed to estimate energy savings of both economizer designs for data centers in

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗