Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Parametric Mechanism Design Through Numerical Optimization and Physics Simulation

Design-Build-Test approaches for developing spaceflight hardware are prohibitively time and cost intensive and often lead to suboptimal mechanism designs. Approaches that couple machine learning and high-fidelity physics simulation could eliminate the need for hardware prototyping and dramatically accelerate the engineering design cycle, ultimately reducing cost. This work presents a modular NASA-developed toolchain to optimize hardware mechanisms in a virtual environment using numerical optimization and multi-body physics simulation. The toolchain enables multi-objective optimization, generates parametric CAD files that can be further post-processed by an end user, and can be expanded to optimize full systems and non-mechanical parameters such as feedback control variables. We demonstrate the toolchain through an independently verifiable design problem that optimizes wheel radius to achieve a desired linear velocity in a rigid-body physics environment when the wheel rotates at a constant angular speed, and then post-process the parametric CAD file of the optimal design generated by the tool before ultimately manufacturing it via 3D printing. We end with a discussion of how the toolchain can incorporate other analysis tools, including finite element analysis, computational fluid dynamics, and granular media simulations.

Optimization↗

Evaluating Thermostats’ Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Thermostats play a crucial role in energy consumption, user control, and occupant comfort by serving as the interface between the heating, ventilation, and air conditioning (HVAC) system and the building's occupants. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on or off. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different thermostats, tested with a residential heat pump, aiming to identify variations in their deadband settings and implications for energy usage and management. The experimental study was conducted using a HVAC hardware-in-the-loop (HIL) system that allows thermostats to be connected with physical HVAC equipment, driven by conditions in a simulated residential building. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats cycle differently based on their deadband settings. The findings offer valuable insights into how thermostat deadband affects comfort and energy use, as well as the cycling frequency of a heat pump.

Ramaraj, Sugirdhalakshmi [National Renewable Energ↗

Post Fukushima tsunami simulations for Malaysian coasts

The recent recurrences of mega tsunamis in the Asian region have rekindled concern regarding potential tsunamis that could inflict severe damage to affected coastal facilities and communities. The 11 March 2011 Fukushima tsunami that crippled nuclear power plants in Northern Japan has further raised the level of caution. The recent discovery of petroleum reserves in the coastal water surrounding Malaysia further ignites the concern regarding tsunami hazards to petroleum facilities located along affected coasts. Working in a group, federal government agencies seek to understand the dynamics of tsunami and their impacts under the coordination of the Malaysian National Centre for Tsunami Research, Malaysian Meteorological Department. Knowledge regarding the generation, propagation and runup of tsunami would provide the scientific basis to address safety issues. An in-house tsunami simulation models known as TUNA has been developed by the authors to assess tsunami hazards along affected beaches so that mitigation measures could be put in place. Capacity building on tsunami simulation plays a critical role in the development of tsunami resilience. This paper aims to first provide a simple introduction to tsunami simulation towards the achievement of tsunami simulation capacity building. The paper will also present several scenarios of tsunami dangers along affected Malaysia coastal regions via TUNA simulations to highlight tsunami threats. The choice of tsunami generation parameters reflects the concern following the Fukushima tsunami.

54 ENVIRONMENTAL SCIENCES↗

A SIMULATION BASED APPROACH TO IMPACT ASSESSMENT OF PHYSICAL FAULTS: LARGE COMMERCIAL BUILDING HVAC CASE STUDY

We develop a simulation-based approach to fault impact analysis for a single duct VAV system, and analyze the dynamic and steady-state impact of equipment physical faults on building operation. The simulation model, a virtual testbed, can capture physical faults in the HVAC system of a large commercial building. The model can be utilized for generating data that can then be analyzed to quantify the impact of single or multiple faults. We illustrate the implementation of three physical faults: supply air temperature sensor bias, outdoor air temperature sensor bias, and cooling coil valve stuck. We simulate each fault with several fault intensity levels and at different seasonal operating conditions. Then, we analyze the impact of the above-mentioned faults using the metrics. The results show that the impact of a given physical fault depends on implemented control logic sequence and the seasonal operating conditions.

Chen, Yan↗

Aemulus $\nu$: precise predictions for matter and biased tracer power spectra in the presence of neutrinos

Here we present the Aemulusν simulations: a suite of 150 (1.05 h -1 Gpc) 3 N-body simulations with a mass resolution of 3.51 × 10 10 Ω cb /0.3 h -1 M ⊙ in a wνCDM cosmological parameter space. The simulations have been explicitly designed to span a broad range in σ8 to facilitate investigations of tension between large scale structure and cosmic microwave background cosmological probes. Neutrinos are treated as a second particle species to ensure accuracy to 0.5 eV, the maximum neutrino mass that we have simulated. By employing Zel'dovich control variates, we increase the effective volume of our simulations by factors of 10-10 5 depending on the statistic in question. As a first application of these simulations, we build new hybrid effective field theory and matter power spectrum surrogate models, demonstrating that they achieve ≤ 1% accuracy for k ≤ 1 hMpc -1 and 0 ≤ z ≤ 3, and ≤ 2% accuracy for k ≤ 4 hMpc -1 for the matter power spectrum. We publicly release the trained surrogate models, and estimates of the surrogate model errors in the hope that they will be broadly applicable to a range of cosmological analyses for many years to come.

79 ASTRONOMY AND ASTROPHYSICS↗

Probabilistic reliability assessment and case studies for predicted energy savings in residential buildings

This study aims to (1) investigate the key influential parameters (KIPs) in estimating the uncertainty of energy savings using a residential building energy simulation model and (2) perform uncertainty quantification for energy savings for several different scenarios. The proposed methodology was successfully applied to the calculation of uncertainties associated with residential energy retrofits using two test houses designed for pre- and post-retrofit cases. Uncertainties were determined using basic parameters that might be supplied to an energy model and then reevaluated based on an audit of the KIPs identified, resulting in substantially reduced uncertainty. Of four different scenarios, the most uncertain scenario estimated the annual energy savings from the retrofit would be between 18% and 51% at a 95% confidence level, and the least uncertain scenario estimated the annual savings would be between 26% and 40% at a 95% confidence level. The actual measured annual savings from the two test houses was 28%, which shows an agreement with the uncertainty analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effective moisture penetration depth model for residential buildings: Sensitivity analysis and guidance on model inputs

Moisture buffering of building materials has a significant impact on the building's indoor humidity, and building energy simulations need to model this buffering to accurately predict the humidity. Researchers requiring a simple moisture-buffering approach typically rely on the effective-capacitance model, which has been shown to be a poor predictor of actual indoor humidity. This paper describes an alternative two-layer effective moisture penetration depth (EMPD) model and its inputs. While this model has been used previously, there is a need to understand the sensitivity of this model to uncertain inputs. In this paper, we use the moisture-adsorbent materials exposed to the interior air: drywall, wood, and carpet. We use a global sensitivity analysis to determine which inputs are most influential and how the model's prediction capability degrades due to uncertainty in these inputs. We then compare the model's humidity prediction with measured data from five houses, which shows that this model, and a set of simple inputs, can give reasonable prediction of the indoor humidity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiative Cooling Paints: Application on Warehouses and Integration with Phase Change Materials

Despite extensive research on radiative cooling (RC), researchers are still working to understand its best implementation strategy and potential benefits. Understanding this could be an instrumental part of reducing building energy costs and combating climate change. In this work, we introduce two concepts to achieve this goal and broaden the application of RC paints. While building energy simulations for RC are common, most studies focus on single-layer paints in residential settings. Limited research exists on warehouses, and no literature has conducted multi-climate zone analyses or included RC technologies with >90% reflectance. As RC technology advances in efficiency, versatility, and affordability, large-scale simulations across diverse climates are crucial, particularly for warehouses as a passive indoor temperature control solution. Here, a TRNSYS-modeled single-story warehouse assesses the energy impact of BaSO4-based RC paints. Another under-explored RC application is its integration with phase change materials (PCMs), which provide thermal regulation via latent heat storage. Though RC and PCMs have been combined by placing PCMs atop, beneath, or within RC layers, studies focus on either experiments or modeling, with no validation between the two. Here, we develop a simple RC+PCM experimental and modeling setup, placing RC paint atop an aluminum cell filled with a Rubitherm PCM.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulated effects of sample size and grain neighborhood on the modeling of extreme value fatigue response

Assessing the size of representative volume elements (RVEs) for fatigue-related applications is challenging. A RVE relevant to random microstructure requires a volume of material that is sufficiently large to capture the grain/phase heterogeneity that captures all statistical moments of the distribution of the driving force for fatigue crack formation at “hot spot” grains. Consequently, the large size of a microstructure RVE required to study fatigue phenomena is largely computationally intractable and difficult to explore. A more realistic objective in this work is to systematically study, as a function of the size of a statistical sample of microstructure, trends towards convergence of the simulated distribution of driving force for fatigue crack formation. Our present work accordingly leverages the recently developed open-source PRISMS-Fatigue framework to examine the trends in convergence of extreme value distributions (EVD) of Fatigue Indicator Parameters (FIPs) in progressively larger polycrystalline microstructure realizations of FCC Al alloy 7075-T6 using crystal plasticity finite element method simulations. The results are compared to the traditional method in which ensembles of statistical volume elements (SVEs) are simulated to build up statistics intended to approximate those associated with a larger volume of material. The convergence of EVDs with increase of size of a SVE of microstructure is closely related to the extent of grain nearest neighbor (NN) interactions. Accordingly, the sensitivity of the local micromechanical response at hot spot grains is quantitatively investigated by systematically varying the orientations of NN grains. Results indicate that SVEs with cubic crystallographic texture tend towards convergence of the EVD of FIPs with tens of thousands of grains while the random and rolled textures require larger volumes. Simple relationships based on microstructure parameters (e.g., Schmid Factor, grain size, NN misorientation) do not completely correlate to fatigue hot spot grains. Finally, the sensitivity of the extreme value fatigue response at hot spot grains extends to the 3rd NN when a single neighborhood grain orientation is altered.

36 MATERIALS SCIENCE↗

Parametric study of solid-solid translucent phase change materials in building windows

Thermal energy storage and solar radiation management are crucial to improve the sustainability and energy efficiency of buildings. Compared with the implementation of phase change materials (PCMs) in opaque components, the energy saving potential of incorporating PCMs in transparent glazing windows is much less studied and not well understood. Here we present a comprehensive parametric study of novel PCM windows for building energy saving with a focus on optimizing and quantitatively distinguishing the contributions from the optical and thermal properties of the PCM, which is particularly useful for the design of solid-solid PCM windows. We investigate a reference commercial office building using EnergyPlus by developing an equivalent model of our PCM window that is compatible with EnergyPlus's modeling capabilities. Compared with a clear-clear double-pane window, the integration of 3 mm solid-solid PCMs with optimal properties in warm, mixed, and cold climates can respectively save up to 17.2%, 14.0%, and 5.8% energy for the HVAC (heating, ventilation, and air conditioning) system, and 9.4%, 6.7%, and 3.2% energy for the whole building. We also demonstrate that these energy savings are most sensitive to the solar absorptance of PCMs for all three climates. The optimal transition temperature varies with climate and is related to the climate and solar radiation heat gain. Other issues are also briefly discussed, such as hysteresis, window orientations, and the effect of interior lighting. Finally, although the optimal PCM windows show energy saving performance comparable with low-emissivity windows, the PCM windows provide a unique advantage in terms of shifting HVAC loads which can provide benefits to the electrical grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An ontology to represent synthetic building occupant characteristics and behavior

Since the introduction of the occupant behavior Drivers-Needs-Actions-Systems (DNAS) framework in 2013, researchers have used the framework or further developed it based on their case studies, which include efforts to collect new data on occupant behaviors. The effort is often costly for the relatively few new data points added. Problems emerge when the already collected data do not meet the modelers' interoperability requirements. Previous studies addressed this issue by developing more sophisticated ontologies that enable integration with other datasets and synthetic data methodologies that would meet unique research applications. This paper presents an extension of the DNAS framework for the representation of synthetic occupant data to support various applications and use cases across the building life cycle. An agent-based modeling application is one of our motivations that requires more elaborate characteristics of an occupant-agent or a group-of-agent. The extension, built upon a review of the literature, introduces new elements to the framework that fall into five categories, including socio-economic, geographical location, activities, subjective values, and individual and collective adaptive actions. On-going research includes identifying occupant datasets and developing data fusion methods to generate synthetic occupants, as well as to demonstrate its applications in agent-based modeling coupled with building performance simulation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Data mining of space heating system performance in affordable housing

The space heating in residential buildings accounts for a considerable amount of the primary energy use. Therefore, understanding the operation and performance of space heating systems becomes crucial in improving occupant comfort while reducing energy use. This study investigated the behavior of occupants adjusting their thermostat settings and heating system operations in a 62-unit affordable housing complex in Revere, Massachusetts, USA. The data mining methods, including clustering approach and decision trees, were used to ascertain occupant behavior patterns. Data tabulating ON/OFF space heating states was assessed, to provide a better understanding of the intermittent operation of space heating systems in terms of system cycling frequency and the duration of each operation. The decision tree was used to verify the link between room temperature settings, house and heating system characteristics and the heating energy use. The results suggest that the majority of apartments show fairly constant room temperature profiles with limited variations during a day or between weekday and weekend. Data clustering results revealed six typical patterns of room temperature profiles during the heating season. Space heating systems cycled more frequently than anticipated due to a tight range of room thermostat settings and potentially oversized heating capacities. In conclusion, from this study affirm data mining techniques are an effective method to analyze large datasets and extract hidden patterns to inform design and improve operations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupancy data analytics and prediction: A case study

Occupants are a critical impact factor of building energy consumption. Numerous previous studies emphasized the role of occupants and investigated the interactions between occupants and buildings. However, a fundamental problem, how to learn occupancy patterns and predict occupancy schedule, has not been well addressed due to highly stochastic activities of occupants and insufficient data. This study proposes a data mining based approach for occupancy schedule learning and prediction in office buildings. The proposed approach first recognizes the patterns of occupant presence by cluster analysis, then learns the schedule rules by decision tree, and finally predicts the occupancy schedules based on the inducted rules. A case study was conducted in an office building in Philadelphia, U.S. Based on one-year observed data, the validation results indicate that the proposed approach significantly improves the accuracy of occupancy schedule prediction. The proposed approach only requires simple input data (i.e., the time series data of occupant number entering and exiting a building), which is available in most office buildings. Furthermore, this approach is practical to facilitate occupancy schedule prediction, building energy simulation and facility operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic metrics of natural ventilation cooling effectiveness for interactive modeling

The evaluation of natural ventilation potential for cooling indoor spaces during the early design phases is of great interest to researchers and practitioners. Among various definitions and usages for natural ventilation potential (NVP) in early design evaluation, this paper reviews and identifies the key performance indicators, and proposes two new dynamic metrics—natural ventilation cooling effectiveness (NVCE) and climate potential utilization ratio (CPUR). The metrics are dynamically responsive to various design options, in both steady and transient states, allowing consideration of thermal mass. Assisting in design development processes, the metrics quantify how well indoor spaces make use of natural ventilation’s cooling capacity. Case studies are presented to demonstrate how NVCE and CPUR enable designers to evaluate the predicted performance and how to apply the information to improve building design. Finally, the results of the design iterations showed that the relationship among various design parameters should be dynamically understood in order to evaluate the performance of natural ventilation, confirming that “the more the airflow, the greater the potential,” and “the heavier the thermal mass, the greater the energy saving” were not always true.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying the benefits of a building retrofit using an integrated system approach: A case study

Building retrofits provide a large opportunity to significantly reduce energy consumption in the buildings sector. Traditional building retrofits focus on equipment upgrades, often at the end of equipment life or failure, and result in replacement with marginally improved similar technology and limited energy savings. The Integrated System (IS) retrofit approach enables much greater energy savings by leveraging interactive effects between end use systems, enabling downsized or lower energy technologies. This work presents a case study in Hawaii quantifying the benefits of an IS retrofit approach compared to two traditional retrofit approaches: a Standard Practice of upgrading equipment to meet minimum code requirements, and an Improved Practice of upgrading equipment to a higher efficiency. The IS approach showed an energy savings of 84% over existing building energy use, much higher than the traditional approaches of 13% and 33%. The IS retrofit also demonstrated the greatest energy cost savings potential. While the degree of savings realized from the IS approach will vary by building and climate, these findings indicate that savings on the order of 50% and greater are not possible without an IS approach. It is therefore recommended that the IS approach be universally adopted to achieve deep energy savings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An economic and technical feasibility analysis of a dual-source heat pump using both the air and the ground

The study investigates the economic and technical performance of a novel dual-source heat pump (DSHP) compared with that of air-source heat pumps (ASHPs) and ground-source heat pumps (GSHPs). The DSHP can use both ambient air and the ground as a heat source or heat sink. It uses ambient air when its temperature is favorable for efficient heat pump operation. When the ambient temperature is too hot or cold, the ground source is used to retain high-efficiency heat pump operation. Since the DSHP can alternately use either the ground heat exchanger (GHE) or ambient air to meet the thermal load, the required size of GHE can be smaller than those of GSHPs. This study models the DSHP using a whole building energy simulation tool (EnergyPlus) coupled with a Python plug-in and Heat Pump Design Model (HPDM) to simulate its heating and cooling performance for a typical single-family home in 15 US climate zones. The required GHE size of the DSHP system is determined through simulations and compared with that of GSHPs. DSHP deployment can reduce electricity use compared to ASHPs, especially in cold climates where it shows a reduction of around 50%. When compared to GSHPs, DSHPs use 20%–40% more electricity in warm climates but consume around the same amount in moderate and colder climates. Since the DSHP can use air source when the ambient temperature is mild, the GHE size needed for the DSHP is about 40% less than that needed for GSHPs in hot climates and about 25% less in cold climates. In conclusion, the life cycle cost analysis shows that the DSHP is economically more feasible than ASHPs in colder regions and economically more feasible than GSHPs in hot and cold regions.

Dual-source heat pumps↗