Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Accurate prediction of mega-electron-volt electron beam properties from UED using machine learning

To harness the full potential of the ultrafast electron diffraction (UED) and microscopy (UEM), we must know accurately the electron beam properties, such as emittance, energy spread, spatial-pointing jitter, and shot-to-shot energy fluctuation. Owing to the inherent fluctuations in UED/UEM instruments, obtaining such detailed knowledge requires real-time characterization of the beam properties for each electron bunch. While diagnostics of these properties exist, they are often invasive, and many of them cannot operate at a high repetition rate. Here, we present a technique to overcome such limitations. Employing a machine learning (ML) strategy, we can accurately predict electron beam properties for every shot using only parameters that are easily recorded at high repetition rate by the detector while the experiments are ongoing, by training a model on a small set of fully diagnosed bunches. Applying ML as real-time noninvasive diagnostics could enable some new capabilities, e.g., online optimization of the long-term stability and fine single-shot quality of the electron beam, filtering the events and making online corrections of the data for time-resolved UED, otherwise impossible. This opens the possibility of fully realizing the potential of high repetition rate UED and UEM for life science and condensed matter physics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multibeam Electron Diffraction

One of the primary uses for transmission electron microscopy (TEM) is to measure diffraction pattern images in order to determine a crystal structure and orientation. In nanobeam electron diffraction (NBED), we scan a moderately converged electron probe over the sample to acquire thousands or even millions of sequential diffraction images, a technique that is especially appropriate for polycrystalline samples. However, due to the large Ewald sphere of TEM, excitation of Bragg peaks can be extremely sensitive to sample tilt, varying strongly for even a few degrees of sample tilt for crystalline samples. In this paper, we present multibeam electron diffraction (MBED), where multiple probe-forming apertures are used to create multiple scanning transmission electron microscopy (STEM) probes, all of which interact with the sample simultaneously. We detail designs for MBED experiments, and a method for using a focused ion beam to produce MBED apertures. We show the efficacy of the MBED technique for crystalline orientation mapping using both simulations and proof-of-principle experiments. We also show how the angular information in MBED can be used to perform 3D tomographic reconstruction of samples without needing to tilt or scan the sample multiple times. Finally, we also discuss future opportunities for the MBED method.

47 OTHER INSTRUMENTATION↗

A Novel Technique for Pulsed Operation of Magnetrons without Modulation of Cathode Voltage

Modern pulsed superconducting accelerators of megawatt beams require efficient RF sources controllable in phase and power. For each Superconducting RF (SRF) cavity is desirable a separate RF source with power up to hundreds of kW with pulse duration in the millisecond range. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) is lower than that of the magnetrons, while the cost of a unit of RF power is much higher. Therefore the magnetron-based RF sources would significantly reduce the capital and operation costs in comparison with the traditional RF sources. A recently developed an innovative technique makes possible the pulsed generation of magnetrons powered below the self-excitation threshold voltage. This technique does not require pulse modulators to form RF pulses. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in pulsed modes with large duty factor. The developed technique and its experimental verification are considered and discussed.

43 PARTICLE ACCELERATORS↗

A holistic approach to the optimization of neutron beam transport at the LANSCE facility

An advanced neutron beam collimation system has been developed as part of an effort to optimize neutron beam transport at the Weapons Neutron Research (WNR) Facility, located within the Los Alamos Neutron Science Center (LANSCE). The goal of this work was to develop and demonstrate techniques to tailor neutron delivery in order to provide maximum available flux on sample with a specific beam profile, while simultaneously reducing unwanted background. A holistic approach was taken, upgrading the facility spallation target, facility metrology infrastructure, and flight path shutter insert to support the implementation of this advanced collimation system. Here, modern instruments and software were employed to conduct facility surveys, characterization of as-built geometry of critical components, 3D ray tracing and neutron transport calculations. Beam images and flux measurements were acquired after installation to evaluate the performance of the collimation system and to demonstrate consistent agreement with MCNP simulations which showed an 87% increase of flux on sample while providing suppression of background neutron impingement on the sample frame by 10 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utilizing Quantum Cascade Lasers for Ultranarrow Velocity Resolution and Quantum-State Selectivity in Molecular Beam Scattering and Spectroscopy

Here, we demonstrate the capability of a narrow linewidth quantum cascade laser (QCL) to selectively excite a very narrow velocity range of nitric oxide (σ ≤ 7(3) m/s) with a pure ro-vibrational quantum state. By implementing a counter-propagating geometry, the molecules are selectively excited according to the Doppler shift of the ro-vibrational transition frequency such that the velocity width associated with the excited molecules depends only on the QCL linewidth. We demonstrate a velocity distribution limited by the effective linewidth of our free-running QCL (Γ = 3.2 MHz). Our development provides a cost-effective, flexible approach to resolve quantum-state selective chemical dynamics with excellent velocity resolution in a wide variety of molecules with infrared-active transitions. This technique has been formulated to provide ultrahigh collisional energy resolution in molecular beams to delineate final quantum-state product pairs in studies of molecular collisions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multislice forward modeling of coherent surface scattering imaging on surface and interfacial structures

To study nanostructures on substrates, surface-sensitive reflection-geometry scattering techniques such as grazing incident small angle X-ray scattering are commonly used to yield an averaged statistical structural information of the surface sample. Grazing incidence geometry can probe the absolute three-dimensional structural morphology of the sample if a highly coherent beam is used. Coherent surface scattering imaging (CSSI) is a powerful yet non-invasive technique similar to coherent X-ray diffractive imaging (CDI) but performed at small angles and grazing-incidence reflection geometry. A challenge with CSSI is that conventional CDI reconstruction techniques cannot be directly applied to CSSI because the Fourier-transform-based forward models cannot reproduce the dynamical scattering phenomenon near the critical angle of total external reflection of the substrate-supported samples. To overcome this challenge, we have developed a multislice forward model which can successfully simulate the dynamical or multi-beam scattering generated from surface structures and the underlying substrate. The forward model is also demonstrated to be able to reconstruct an elongated 3D pattern from a single shot scattering image in the CSSI geometry through fast-performing CUDA-assisted PyTorch optimization with automatic differentiation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Parametric study of Alfvénic instabilities driven by runaway electrons during the current quench in DIII-D

Abstract To avoid or mitigate runaway electron (RE) beams in ITER, RE-driven instabilities are actively studied as a complimentary technique to massive material injection. In this work we report experimental dependencies of Alfvénic instabilities driven by REs during the current quench in DIII-D on plasma and material injection parameters. These instabilities, observed in the frequency range of 0.1–3 MHz, correlate with increased RE loss and thus may play a role in non-sustained RE beams. It was found that as the toroidal magnetic field ( B T ) decreases, the RE population becomes more energetic, the energy of instabilities increases, and no RE beam is observed when the maximum energy of REs exceeds 15 MeV (or when B T is below 1.8 T). Analysis of disruptions at plasma core temperature ( T e ) of 1 keV and 8 keV shows that the RE population is much less energetic (with the maximum energy of only about 3 MeV) when T e is high, and no instabilities are observed in this case. Besides disruptions above caused by Ar injection, cases with Ne and D 2 injections were also studied. Both Ne and D 2 injections cause no sustained RE beams, however, for different reasons. Measurements of the instability polarization indicate that it is of predominantly compressional nature at the edge, which is consistent with modeling suggesting excitation of compressional Alfvén eigenmodes. However, drive of global Alfvén eigenmodes is also possible at low frequencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ x-ray studies of growth of complex oxides on graphene by molecular beam epitaxy

Future technologies are likely to exploit flexible heterostructures exhibiting multifunctional properties constructed from multiple materials. One technique for the synthesis of such systems relies on remote epitaxy, a method employing graphene as a sacrificial layer between a crystalline substrate and an epitaxial film. The technique can be used to create single crystal heterostructures comprised of stacked epitaxial films, their properties optimized by minimizing incompatibilities between the different materials. Details regarding nucleation and growth via remote epitaxy remain unknown, however, due to the many difficulties in studying synthesis in the growth environment with atomic-scale resolution. Here, we describe an in situ synchrotron x-ray investigation of complex oxide thin film growth on graphene by molecular beam epitaxy. Phase retrieval methods were used to reconstruct the electron density profiles from x-ray crystal truncation rods measured under different growth conditions. Our in situ observations combined with post-growth spectroscopy provide a number of key insights regarding graphene in the synthesis environment and the resulting effects on the complex oxide/graphene heterostructure.

36 MATERIALS SCIENCE↗

Porosity evolution in proton irradiated microfine-grained POCO graphite

This work investigated the porosity evolution of POCO ZXF-5Q graphite that has been irradiated by 340 kW, 120 GeV protons inside NT02 target system in Fermilab's NuMI beamline. This POCO graphite has undergone direct bulk dimensional swelling at low dose irradiation and its local microstructural change is still not well-understood during this process. In this work, the (sub-) micrometre scale porosity from six locations across proton beam fluence and temperature gradients have been studied using focused ion beam-scanning electron microscopy (FIB-SEM) tomography. Here, a deep learning-based tomographic image segmentation technique has been established and implemented for porosity segmentation and quantification. It has been found that there is a decrease in the total volumetric percentage of the porosity at proton beam centre (~ 8 – 8.4 vol.%), by comparing to un-irradiated POCO (~ 12 – 13vol.%) and to beam 2σ and 5σ radii (~ 12vol.%). This decrease in porosity volume percentage was found to be caused by the reduction in pores with volumes > 0.1 μm 3 induced by material bulk dimensional swelling at proton beam centre area. The porosity reduction in relation to dimensional change and irradiation creep was discussed among with other contributing factors, and further investigations through well-controlled irradiation experiment are still needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploring isospin symmetry breaking in exotic nuclei: High-precision mass measurement of 23 Si and shell-model calculations of 𝑇 = 5/2 nuclei

Here, we present a high-precision mass measurement of the proton-rich nucleus 23 Si, performed with the LEBIT Penning trap at the Facility for Rare Isotope Beams (FRIB) utilizing the time-of-flight ion cyclotron resonance (TOF-ICR) technique. We determined a mass excess of 23362.9(5.8) keV, which agrees with a recent storage-ring measurement from the experimental Cooler-Storage Ring (CSRe) in Lanzhou but has a factor of 20 improved precision 23 Si is hence the nucleus with the most precisely known mass among all nuclei with an isospin projection of 𝑇 𝑧 = −5/2. We performed shell-model calculations with the USDC and USDCm Hamiltonians to study binding energy differences and Thomas-Ehrmann shifts in mirror systems with an isospin up to 𝑇 = 5/2. Our experimental result and other recently reported masses of neutron-deficient sd-shell nuclei agree well with the theoretical predictions, demonstrating that isospin symmetry breaking in sd-shell nuclei—even at high isospin values—is well described by modern shell-model calculations.

20 ≤ A ≤ 38↗

Adaptive sampling for accelerating neutron diffraction-based strain mapping *

Abstract Neutron diffraction is a useful technique for mapping residual strains in dense metal objects. The technique works by placing an object in the path of a neutron beam, measuring the diffracted signals and inferring the local lattice strain values from the measurement. In order to map the strains across the entire object, the object is stepped one position at a time in the path of the neutron beam, typically in raster order, and at each position a strain value is estimated. Typical dwell times at neutron diffraction instruments result in an overall measurement that can take several hours to map an object that is several tens of centimeters in each dimension at a resolution of a few millimeters, during which the end users do not have an estimate of the global strain features and are at risk of incomplete information in case of instruments outages. In this paper, we propose an object adaptive sampling strategy to measure the significant points first. We start with a small initial uniform set of measurement points across the object to be mapped, compute the strain in those positions and use a machine learning technique to predict the next position to measure in the object. Specifically, we use a Bayesian optimization based on a Gaussian process regression method to infer the underlying strain field from a sparse set of measurements and predict the next most informative positions to measure based on estimates of the mean and variance in the strain fields estimated from the previously measured points. We demonstrate our real-time measure-infer-predict workflow on additively manufactured steel parts—demonstrating that we can get an accurate strain estimate even with 30%–40% of the typical number of measurements—leading the path to faster strain mapping with useful real-time feedback. We emphasize that the proposed method is general and can be used for fast mapping of other material properties such as phase fractions from time-consuming point-wise neutron measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhanced sensitivity for electron affinity measurements of rare elements

The electron affinity (EA), the energy released when a neutral atom binds an additional electron, is a fundamental property of atoms that is governed by electron-electron correlations and is strongly related to an element’s chemical reactivity. However, conventional techniques for EA determination lack the experimental sensitivity to probe very scarce samples. As a result, the EA for the heaviest elements of the periodic table is entirely uncharted. Here, we present a novel technique to determine EAs through Laser Photodetachment Threshold Spectroscopy, performed in an electrostatic ion beam trap to increase the samples’ exposure to laser photons and, thus, improve the experimental signal sensitivity by three orders of magnitude. Moreover, the additional exposure time allows the use of lower-power continuous-wave narrow-band lasers that reduce uncertainties associated with broadening effects induced by the laser bandwidth. By applying this technique, we measure the EA of 35 Cl to be 3.612720(44) eV, achieving state-of-the-art precision while employing five orders of magnitude fewer anions. The demonstrated sensitivity paves the way for systematic EA measurements across isotopic chains - including isotope shifts and hyperfine splittings - and ultimately for the first direct determination of electron affinities in superheavy elements.

Maier, F. M. [Univ. of Greifswald (Germany); Europ↗

Development of a Beam Halo Monitor

Muons, Inc. proposed improved Residual-Gas luminescent Beam Profile Monitors for Intense Beams by adding novel features including a mirascope, a light collecting device devised in the 16th century by an inventor of the telescope. A modern mirascope consists of 2 paraboloids. Light generated by the beam is collected by the paraboloids and creates a beam image. By placing a lens near the image it is possible to collect almost 100% of the emitted light, up to ten times better than existing fluorescence profilometers. Intense (multi-MW) proton beams pose a challenge for beam profile measurements. Solid-based beam intercepting instrumentation produces unallowable levels of radiation at these high powers. An alternative is to use a zero-or-low mass device such as a residual-gas profile monitor, either through collection of ionization or fluorescence. Fluorescence has an intrinsic advantage over the usual collection of ionized electrons in that it is not affected by the strong and variable electric and magnetic fields created by the beam that can distort profiles and make calibration difficult. For this reason, we proposed the fluorescence technique using the mirascope and other methods to enhance light collection and versatility by modifying the residual gas and its spatial distribution. In Phase I, we designed a mirascope and its electronics for commissioning and beam tests in a proposed Phase II. The design was based on optical simulations done in Phase I, and a physics run plan was developed for optimizing and testing. The Phase II experimental site and program have been planned and our goal is to produce a universal low cost Mirascope Residual-Gas Luminescent Beam Profile Monitor that can replace all other profile monitors currently used in accelerators.

43 PARTICLE ACCELERATORS↗

Impedance Based Fixture Neutralization (FINE) Method to Replicate Field Environments in Laboratory Settings

Test article vibration test responses will vary from one test laboratory to another due to differences in shaker and fixture dynamic characteristics. This is also seen between the field and laboratory due to the differing dynamic characteristics between field assembly loading and boundary conditions compared to the laboratory configuration. This work introduces a technique called Impedance Fixture Neutralization which customizes input forces to cause consistent responses for the Device Under Test across different vibration testing conditions. The customized force neutralizes the dynamic variations between configurations for the Device Under Test. The device responses can be replicated in several situations: when using a different fixture with the same attachment points, when the test article mounting location on the fixture changes, when the force location changes, or any combination of these situations. Impedance Fixture Neutralization uses the uncoupled dynamic characteristics of the test article and excitation fixtures to customize the input thereby causing the same test article responses between two mounting configurations (either field to laboratory or two different laboratory configurations). The application of the technique is shown using an analytical model of a two-beam system and analytically using experimental FRFs from plate and frame component hardware characterization tests. In both cases a device under test is attached to two test fixtures wherein the dynamic differences in the configurations are neutralized.

Laboratory↗

In situ synchrotron X-ray imaging and mechanical properties characterization of additively manufactured high-entropy alloy composites

Laser beam directed energy deposition has become an increasingly popular advanced manufacturing technique for materials discovery as a result of the in situ alloying capability. In this study, we leverage an additive manufacturing enabled high throughput materials discovery approach to explore the composition space of a graded W x (CoCrFeMnNi) 100–x sample spanning 0 ≤ x ≤ 21 at%. In addition to microstructural and mechanical characterization, synchrotron high speed x-ray computer aided tomography was conducted on a W 20 (CoCrFeMnNi) 80 composition to visualize melting dynamics, powder-laser interactions, and remelting effects of previously consolidated material. Results reveal the formation of the Fe 7 W 6 intermetallic phase at W concentrations> 6 at%, despite the high configurational entropy. Unincorporated W particles also occurred at W concentrations> 10 at% accompanied by a dissolution band of Fe 7 W 6 at the W/matrix interface and hardness values greater than 400 HV. In this work, the primary strengthening mechanism is attributed to the reinforcement of the Fe 7 W 6 and W phases as a metal matrix composite. The in situ high speed x-ray imaging during remelting showed that an additional laser pass did not promote further mixing of the Fe 7 W 6 or W phases suggesting that, despite the dissolution of the W into the Fe 7 W 6 phase being thermodynamically favored, it is kinetically limited by the thickness/diffusivity of the intermetallic phase, and the rapid solidification of the laser-based process.

36 MATERIALS SCIENCE↗

Speciation mapping of the oxidation layer on aged uranium dioxide using scanning transmission x-ray spectromicroscopy

In this study, UO 2 was aged in humid air and prepared as a thin section using a focused ion beam (FIB) instrument. The specimen was measured using synchrotron radiation spectromicroscopy techniques at the Beamline 11.0.2 STXM end station of the Advanced Light Source (ALS). Non-negative matrix factorization (NMF) methods were used to identify and map three component x-ray absorption near-edge structure (XANES) spectra in the oxygen K-edge data, revealing a surface layer of U 4 O 9 with a thickness of 206 ± 21 nm, and the bulk of the sample remaining as UO 2 . Uranium N 4,5 -edge XANES spectromicroscopy supports these results. The diffusion-controlled parabolic rate constant for UO 2 oxidation to U 4 O 9 was calculated from the observed layer thickness and compared to literature values. Complementary transmission electron microscopy (TEM) was used to image the sample and identify the phases present in various regions, confirming the STXM results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization and alignment of a resonant cavity beam position monitor for the Compact LInear Collider (CLIC) project at CERN

Beam diagnostic devices are essential tools to sense the properties of the beam in particle accelerators. Beam Position Monitors (BPMs) are used to detect the transverse beam spatial coordinates. A large number of high-resolution resonant cavity BPMs, operating at 14GHz, are proposed to monitor the orbit of the two main beam linacs of the CLIC project. This paper discusses innovative calibration techniques on a dedicated test bench in the frame of the PACMAN project. The particular location of the electromagnetic center of the resonant cavity BPM is detected utilizing a stretched-wire measurement approach. Measurements, RF characterization and final fiducialization of the BPM electrical offset are treated with details. Initial studies through EM simulations of the cavity BPM are covered. The presented experimental results prove the feasibility of the alignment methodology with nanometric resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report from: US Muon Workshop 2021: A Road Map for a Future Muon Facility February 1-2, 2021

The workshop titled “US Muon Workshop 2021: A road map for a future Muon Facility” was held virtually on February 1-2, 2021. The workshop aimed to bring together world experts in muon spectroscopy (µSR) and other techniques along with interested stakeholders to evaluate the scientific need to construct a new µSR facility in the United States (US). The more than 200 participants highlighted several key scientific areas for µSR research, including quantum materials, hydrogen chemistry, and battery materials, and how each area could benefit from a new, high flux pulsed muon source. Experts also discussed aspects of the µSR technique, such as low-energy µSR, novel software developments, and beam and detector technologies that could enable revolutionary advances in µSR at a next-generation facility. The workshop concluded with discussion of a concept being developed for a new µSR facility at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory (ORNL). That novel design concept was first envisioned by many of the same µSR experts at a workshop held previously at ORNL in 2016. The participants expressed that the current design had the potential to be a world-leading µSR facility, and strongly encouraged the principal investigators to continue their work in order to refine the concept and determine instrument parameters that would enable new scientific opportunities

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗