At least 505 records · Page 28

Laser wire beam profile monitor in the Spallation Neutron Source (SNS) superconducting linac

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is an accelerator based neutron scattering facility. The SNS uses the large scale high energy superconducting linac (SCL) to provide high beam power utilizing hydrogen ion (H-) beams. For the diagnostics of high-brightness H- beam in the SCL, nonintrusive methods have to be developed. This paper describes design, implementation, theoretical analysis and experimental demonstration of a nonintrusive profile monitor system based on photodetachment, also known as laser wire, installed in the SNS-SCL. The SNS laser wire system is the largest of its kind with a capability of measuring both horizontal and vertical profiles of an operational H- beam at each of the 23 cryomodule stations along the SCL beam line by employing a single light source. Presently 9 laser wire stations have been commissioned which measures H- beam profiles at 9 different locations corresponding to energy levels of 200 MeV to 1 GeV. The laser wire diagnostics has no moving parts inside the beam pipe, causes no contamination on the superconducting surface, and can be run parasitically on an operational neutron production H- beam.

43 PARTICLE ACCELERATORS↗

Focal-Plane Imaging of Crossed Beams in Nonlinear Optics Experiments

An application of focal-plane imaging that can be used as a real time diagnostic of beam crossing in various optical techniques is reported. We discuss two specific versions and demonstrate the capability of maximizing system performance with an example in a combined dual-pump coherent anti-Stokes Raman scattering interferometric Rayleigh scattering experiment (CARS-IRS). We find that this imaging diagnostic significantly reduces beam alignment time and loss of CARS-IRS signals due to inadvertent misalignments.

Bivolaru, Daniel↗

Nonlinear integrable optics beam dynamics experiment and diagnostics

All present circular particle accelerators are built around linear focusing optics. Un-avoidable nonlinear elements appear in accelerators, such as magnetic aberrations and space-charge effects, which are typically corrected using nonlinear magnets. However, these added nonlinearities degrade particle beam stability, and in most cases, the system becomes non-integrable. The Integrable Optics Test Accelerator (IOTA), at Fermi National Accelerator Laboratory (Fermilab), is a test bed to study beam dynamics in integrable lattices for both electron and proton beams, independently. This work presents experimental results of the nonlinear electron beam dynamics behavior in IOTA using an elliptical nonlinear magnet. The elliptical nonlinear magnet allows for a large betatron tune spread, allowing for a stable high-intensity beam. In a future experimental run, minimally invasive beam instrumentation is needed to study time-dependent collective instabilities, and halo formation in space-chargedominated proton beams. Traditional profile monitors are too destructive to the beam or just measure one dimension of the beam. A gas sheet can be injected perpendicular to theproton beam at an angle. By doing so, a two-dimensional, turn-by-turn, transverse profile measurement can be made, which will preserve the integrity of the beam. The developmentand progress of a gas sheet beam profile monitor will also be presented.

43 PARTICLE ACCELERATORS↗

Challenges in Accelerator Beam Instrumentation

The challenges in beam instrumentation and diagnostics for present and future particle accelerator projects are presented. A few examples for advanced hadron and lepton beam diagnostics are given.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diamagnetic Loop Testing on DARHT-I

Diamagnetic loops (DML) can be used as a noninvasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. The loop fundamentally measures the magnetic flux excluded by a diamagnetic object. A comprehensive theory relates the rms beam radius to the excluded flux measured by the DML. We have built, and calibrated a DML apparatus. Recently, this DML has been used to measure the size of the electron beam near the final focus of the DARHT-I flash-radiography accelerator. Results are in agreement with beam transport code predictions. In this article, we review and summarize the construction, calibration, and electron-beam testing of this DML.

43 PARTICLE ACCELERATORS↗

SU-F-207-05: Excess Heat Corrections in a Prototype Calorimeter for Direct Realization of CT Absorbed Dose to Phantom

Purpose: To reconcile air kerma and calorimetry measurements in a prototype calorimeter for obtaining absorbed dose in diagnostic CT beams. While corrections for thermal artifacts are routine and generally small in calorimetry of radiotherapy beams, large differences in relative stopping powers of calorimeter materials at the lower energies typical of CT beams greatly magnify their effects. Work-to-date on the problem attempts to reconcile laboratory measurements with modeling output from Monte Carlo and finite-element analysis of heat transfer. Methods: Small thermistor beads were embedded in a polystyrene (PS) core element of 1 cm diameter, which was inserted into a cylindrical HDPE phantom of 30 cm diameter and subjected to radiation in a diagnostic CT x-ray imaging system. Resistance changes in the thermistors due to radiation heating were monitored via lock-in amplifier. Multiple 3-second exposures were recorded at 8 different dose-rates from the CT system, and least-squares fits to experimental data were compared to an expected thermal response obtained by finite-element analysis incorporating source terms based on semi-empirical modeling and Monte Carlo simulation. Results: Experimental waveforms exhibited large thermal artifacts with fast time constants, associated with excess heat in wires and glass, and smaller steps attributable to radiation heating of the core material. Preliminary finite-element analysis follows the transient component of the signal qualitatively, but predicts a slower decay of temperature spikes. This was supplemented by non-linear least-squares fits incorporating semi-empirical formulae for heat transfer, which were used to obtain dose-to-PS in reasonable agreement with the output of Monte Carlo calculations that converts air kerma to absorbed dose. Conclusion: Discrepancies between the finite-element analysis and our experimental data testify to the very significant heat transfer correction required for absorbed dose calorimetry of diagnostic CT beams. The results obtained here are being used to refine both simulations and design of calorimeter core components.

60 APPLIED LIFE SCIENCES↗

2D Simulations of Diamagnetic Loop Calibrations

Diamagnetic loops can be used as a non-invasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. A comprehensive theory for interpreting data from a diamagnetic loop relates the rms beam radius to the excluded flux measured by the loop and the beam current. Thus, primary calibration of the loop must relate the loop signal directly to the exclude d flux. We have simulated these calibrations with a 2D field solver in order to identify possible sources of uncertainty in our calibration technique.

43 PARTICLE ACCELERATORS↗

Overview of ion source characterization diagnostics in INTF

INdian Test Facility (INTF) is envisaged to characterize ITER diagnostic neutral beam system and to establish the functionality of its eight inductively coupled RF plasma driver based negative hydrogen ion source and its beamline components. The beam quality mainly depends on the ion source performance and therefore, its diagnostics plays an important role for its safe and optimized operation. A number of diagnostics are planned in INTF to characterize the ion source performance. Negative ions and its cesium contents in the source will be monitored by optical emission spectroscopy (OES) and cavity ring down spectroscopy. Plasma near the extraction region will be studied using standard electrostatic probes. The beam divergence and negative ion stripping losses are planned to be measured using Doppler shift spectroscopy. During initial phase of ion beam characterization, carbon fiber composite based infrared imaging diagnostics will be used. Safe operation of the beam will be ensured by using standard thermocouples and electrical voltage-current measurement sensors. A novel concept, based on plasma density dependent plasma impedance measurement using RF electrical impedance matching parameters to characterize the RF driver plasma, will be tested in INTF and will be validated with OES data. The paper will discuss about the overview of the complete INTF diagnostics including its present status of procurement, experimentation, interface with mechanical systems in INTF, and integration with INTF data acquisition and control systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active spectroscopic measurements using the ITER diagnostic system

Active (beam-based) spectroscopic measurements are intended to provide a number of crucial parameters for the ITER device being built in Cadarache, France. These measurements include the determination of impurity ion temperatures, absolute densities, and velocity profiles, as well as the determination of the plasma current density profile. Because ITER will be the first experiment to study long timescale ({approx}1 h) fusion burn plasmas, of particular interest is the ability to study the profile of the thermalized helium ash resulting from the slowing down and confinement of the fusion alphas. These measurements will utilize both the 1 MeV heating neutral beams and a dedicated 100 keV hydrogen diagnostic neutral beam. A number of separate instruments are being designed and built by several of the ITER partners to meet the different spectroscopic measurement needs and to provide the maximum physics information. In this paper, we describe the planned measurements, the intended diagnostic ensemble, and we will discuss specific physics and engineering challenges for these measurements in ITER.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostic performance of the beam emission spectroscopy system on the National Spherical Torus Experiment

The beam emission spectroscopy system on the National Spherical Torus Experiment measures localized density fluctuations on the ion gyroscale. Optical sightlines provide core to edge radial coverage, and the sightlines are aligned to typical pitch angles to maximize cross-field spatial resolution. Sightline images are 2-3 cm, and point spread function calculations indicate image distortion from pitch angle misalignment and atomic state finite lifetimes is minor with a 15% increase in the image size. New generation photodetectors achieve photon noise limited measurements at frequencies up to 400 kHz with refrigerant cooling at -20 Degree-Sign C. Measurements near the pedestal show broadband turbulence up to 100 kHz, and poloidal correlation lengths are about 10 cm. Plasma turbulence signals can be 2-3 orders of magnitude above photon noise and amplifier thermal noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Potential Method for Diagnostics of Subfemtosecond Electron Beams Using Coherent Optical Transition Radiation

Coherent transition radiation (CTR) is widely used in determining the longitudinal e-beam dimensions in the accelerator technology applications. In this study, the CTR process is investigated in a real Au-target for the sake of measuring the size characteristics of the electron bunches with lengths from 100 to 300 nm, and possible applications of such targets is demonstrated.

43 PARTICLE ACCELERATORS↗

EXTREME-ULTRAVIOLET SPECTROSCOPY OF Fe VI-Fe XV AND ITS DIAGNOSTIC APPLICATION FOR ELECTRON BEAM ION TRAP PLASMAS

Extreme-ultraviolet spectra of intermediately ionized iron ions (Fe VI-Fe XIV) in the wavelength range of 125.0-265.0 A have been measured at the Heidelberg electron beam ion trap. Emission spectra were recorded sequentially while varying the electron energy over the range of 75-544 eV in steps of 5 eV. The observed spectra clearly show the evolution of each ionic stage as a function of the electron energy, allowing to distinguish the emission lines from neighboring ion charge species and helping to disentangle possible line blends. The collisional-radiative modeling satisfactorily reproduces the measurement. A comparison with previous astrophysical observations (Sun) reveals that some weak emissions may originate from Fe VI and Fe VII, resulting in incorrect assignment of transition lines. The calculated polarization effects due to nonthermal (monoenergetic) electrons are found to be negligible for most of the emission lines at low-energy electron impact, except for a few lines whose polarization can be over 20%. By line ratio technique, the effective electron density in the trap was estimated to be 7.1{sup +2.4} {sub -3.0} x 10{sup 9}-3.4{sup +0.5} {sub -0.5} x 10{sup 10} cm{sup -3}, slightly depending on the ion charge state.

79 ASTRONOMY AND ASTROPHYSICS↗

An adaptive masking method for beam halo measurement by a digital micro mirror device

We report that in high intensity particle beams, irregularities in cathode emission, scattering effects, dark current and space charge forces can lead to a common phenomenon termed beam halo with associated emittance growth, beam loss and overall beam quality degradation. It is of fundamental interest and practical importance to precisely monitor such beam halo, which could offer valuable insights into the experimental strategy for the suppression of this undesired feature. A Digital Micro mirror Device (DMD) is a computer-controlled micro-electrical-mechanical system that contains a compact array of physically independent reflective mirrors. Using a standard DMD, we come up with an adaptive masking method for halo measurement, which demonstrates superior robustness and efficiency comparing to the conventional approaches as confirmed by simulation and experimental results. Our development includes an integrated package of hardware, software and a graphic user interface (GUI) that is robust and portable and can be applied as a beam halo diagnostic for electron guns or radiating charged particle beams in general.

43 PARTICLE ACCELERATORS↗

Diagnostic studies of ion beam formation in inductively coupled plasma

This dissertation describes a variety of studies focused on the plasma and the ion beam in inductively coupled plasma mass spectrometry (ICP-MS). The ability to use ICP-MS for measurements of trace elements in samples requires the analytes to be efficiently ionized. Updated ionization efficiency tables are discussed for ionization temperatures of 6500 K and 7000 K with an electron density of 1 x 10 15 cm -3 . These values are reflective of the current operating parameters of ICP-MS instruments. Calculations are also discussed for doubly charged (M 2+ ) ion formation, neutral metal oxide (MO) ionization, and metal oxide (MO + ) ion dissociation for similar plasma temperature values. Ionization efficiency results for neutral MO molecules in the ICP have not been reported previously.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗