Simulations of coherent beam-beam effects with head-on compensation

Electron lenses are under construction for installation in RHIC in order to mitigate the head-on beam-beam effects. This would allow operation with higher bunch intensity and result in a significant increase in luminosity. We report on recent strong-strong simulations and experiments that were carried out using the RHIC upgrade parameters to assess the impact of coherent beam-beam effects in the presence of head-on compensation.

43 PARTICLE ACCELERATORS↗

Coherent beam-beam effects observation and mitigation at the RHIC collider

In polarized proton operation in RHIC coherent beam-beam modes are routinely observed with beam transfer function measurements in the vertical plane. With the existence of coherent modes a larger space is required in the tune diagram than without them and stable conditions can be compromised for operation with high intensity beams as foreseen for future luminosity upgrades. We report on experiments and simulations carried out to understand the existence of coherent modes in the vertical plane and their absence in the horizontal plane, and investigate possible mitigation strategies.

43 PARTICLE ACCELERATORS↗

Precision Absolute Beam Current Measurement of Low Power Electron Beam

Precise measurements of low power CW electron beam current for the Jefferson Lab Nuclear Physics program have been performed using a Tungsten calorimeter. This paper describes the rationale for the choice of the calorimeter technique, as well as the design and calibration of the device. The calorimeter is in use presently to provide a 1% absolute current measurement of CW electron beam with 50 to 500 nA of average beam current and 1-3 GeV beam energy. Results from these recent measurements will also be presented.

43 PARTICLE ACCELERATORS↗

Beam position monitor for energy recovered linac beams

A method of determining the beam position in an energy recovered linac (ERL). The method makes use of in phase and quadrature (I/Q) demodulation techniques to separate the pickup signal generated by the electromagnetic fields generated by the first and second pass beam in the energy recovered linac. The method includes using analog or digital based I/Q demodulation techniques in order to measure the relative amplitude of the signals from a position sensitive beam pickup such as a button, strip line or microstripline beam position monitor.

47 OTHER INSTRUMENTATION↗

Investigation of Beam Emittance and Beam Transport Line Optics on Polarization

Effects of beam emittance, energy spread, optical parameters and magnet misalignment on beam polarization through particle transport systems are investigated. Particular emphasis will be placed on the beam lines being used at Fermilab for the development of the muon beam for the Muon g-2 experiment, including comparisons with the natural polarization resulting from pion decay, and comments on the development of systematic correlations among phase space variables.

43 PARTICLE ACCELERATORS↗

High collection efficiency X-ray spectrometer system with integrated electron beam stop, electron detector and X-ray detector for use on electron-optical beam lines and microscopes

An X-ray spectrometer systems and methods are provided for implementing signal detection for use on electron-optical beam lines and microscopes. The X-ray Spectrometer System (XSS) includes an X-ray detector (XD) measuring the X-ray signal and positioned proximate to a specimen. An environmental isolation window together with an electron beam stop is disposed between XD and the specimen. The environmental isolation window and the electron beam stop protect XD from electrons directly transmitted through the specimen. An electron detector is located between the electron beam stop and the specimen allowing the measurement of scattered electrons. The XD measures an X-ray signal in the X-ray spectrometer system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WEAK-STRONG SIMULATION OF BEAM-BEAM EFFECTS IN SUPER PROTON-PROTON COLLIDER

A Super Proton-Proton Collider (SPPC) that aims to explore new physics beyond the standard model will be built in China. Here we focus on the impact of beam-beam interactions in the SPPC. Simulations show that with the current optics and nominal tunes, the dynamic aperture (DA) with all the beam-beam interactions is less than 6σ, the dominant cause being the long-range interactions. First, we show the results of a tune scan done to maximize the DA. Next, we discuss the compensation of the long-range interactions by increasing the crossing angle and also by using current carrying wires.

43 PARTICLE ACCELERATORS↗

Calibration of the analog beam-signal hardware for the credited engineered beam power limit system at the Proton Power Upgrade Project at the Spallation Neutron Source

A programmable signal processor-based credited safety control that calculates pulsed beam power based on beam kinetic energy and charge was designed as part of the Proton Power Upgrade (PPU) project at the Spallation Neutron Source (SNS). The system must reliably shut off the beam if the average power exceeds 2.145 MW averaging over 60 seconds. System calibration requires pedigree in measurements, calibration setup, and calculations. This paper discusses the calibration of the analog beam signal components up to and including the Analog Digital Convertors (ADCs) for implementation into the Safety Programmable Logic Controllers (PLCs) and Field Programmable Gate Arrays (FPGAs).

Bobrek, Miljko↗

External beam planning module of Eclipse for external beam radiation therapy

Eclipse is a 3-dimensional (3D) treatment planning system for radiation therapy offered by Varian Medical Systems, Inc. The system has the network connectivity for the electronic transfer of image datasets and digital data communication among different equipment. The scope of this project for this special issue of Medical Dosimetry on 3D treatment planning systems is the assessment of planning tools in the external beam planning module of Eclipse to generate optimized treatment plans for patients undergoing external beam radiation therapy. This treatment planning system is relatively mature to be able to generate (1) simple treatment plans, (2) conformal radiation therapy plans, (3) static intensity-modulated radiation therapy (IMRT) plans, (4) volumetric-modulated arc therapy (VMAT) plans, and (5) treatment plans for electron beam therapy. The treatment planning tools are relatively plentiful to assist in the radiation therapy treatment planning. Some new features have been incorporated in the latest version and are helpful for making high-quality treatment plans. However, the location of the tools is not intuitive, and hence, familiarity with the user interface is essential to the efficient use of the treatment planning system. In addition, there are a number of dose algorithms available for the computation of dose distributions. The understanding of each dose computation algorithm is essential for the optimal use of this treatment planning system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emittance of positron beams produced in intense laser plasma interaction

The first measurement of the emittance of intense laser-produced positron beams has been made. The emittance values were derived through measurements of positron beam divergence and source size for different peak positron energies under various laser conditions. For one of these laser conditions, we used a one dimensional pepper-pot technique to refine the emittance value. The laser-produced positrons have a geometric emittance between 100 and 500 mm{center_dot}mrad, comparable to the positron sources used at existing accelerators. With 10{sup 10}-10{sup 12} positrons per bunch, this low emittance beam, which is quasi-monoenergetic in the energy range of 5-20 MeV, may be useful as an alternative positron source for future accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cold atomic beam ion source for focused ion beam applications

We report measurements and modeling of an ion source that is based on ionization of a laser-cooled atomic beam. We show a high brightness and a low energy spread, suitable for use in next-generation, high-resolution focused ion beam systems. Our measurements of total ion current as a function of ionization conditions support an analytical model that also predicts the cross-sectional current density and spatial distribution of ions created in the source. The model predicts a peak brightness of 2 × 10{sup 7} A m{sup −2} sr{sup −1} eV{sup −1} and an energy spread less than 0.34 eV. The model is also combined with Monte-Carlo simulations of the inter-ion Coulomb forces to show that the source can be operated at several picoamperes with a brightness above 1 × 10{sup 7} A m{sup −2} sr{sup −1} eV{sup −1}. We estimate that when combined with a conventional ion focusing column, an ion source with these properties could focus a 1 pA beam into a spot smaller than 1 nm. A total current greater than 5 nA was measured in a lower-brightness configuration of the ion source, demonstrating the possibility of a high current mode of operation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of lateral photovoltage towards contactless light beam induced current measurements and its dependence on the finite beam size

The nature of the signal due to light beam induced current (LBIC) at the remote contacts is verified as a lateral photovoltage for non-uniformly illuminated planar p-n junction devices; simulation and experimental results are presented. The limitations imposed by the ohmic contacts are successfully overcome by the introduction of capacitively coupled remote contacts, which yield similar results without any significant loss in the estimated material and device parameters. It is observed that the LBIC measurements introduce artefacts such as shift in peak position with increasing laser power. Simulation of LBIC signal as a function of characteristic length L{sub c} of photo-generated carriers and for different beam diameters has resulted in the observed peak shifts, thus attributed to the finite size of the beam. Further, the idea of capacitively coupled contacts has been extended to contactless measurements using pressure contacts with an oxidized aluminium electrodes. This technique avoids the contagious sample processing steps, which may introduce unintentional defects and contaminants into the material and devices under observation. Thus, we present here, the remote contact LBIC as a practically non-destructive tool in the evaluation of device parameters and welcome its use during fabrication steps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress of beam diagnosis system for EAST neutral beam injector

Neutral beam injection has been recognized as one of the most effective means for plasma heating. According to the research plan of the EAST physics experiment, two sets of neutral beam injector (NBI) were built and operational in 2014. The paper presents the development of beam diagnosis system for EAST NBI and the latest experiment results obtained on the test-stand and EAST-NBI-1 and 2. The results show that the optimal divergence angle is (0.62°, 1.57°) and the full energy particle is up to 77%. They indicate that EAST NBI work properly and all targets reach or almost reach the design targets. All these lay a solid foundation for the achievement of high quality plasma heating for EAST.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam profile and coherence properties of synchrotron beams after reflection on modified multilayer mirrors

Multilayer mirrors present an attractive alternative for reflective hard X-ray monochromators due to their increased bandwidth compared with crystal-based systems. An issue remains the strong modulations in the reflected beam profile, i.e. an irregular stripe pattern. This is a major problem for micro-imaging applications, where multilayer-based monochromators are frequently employed to deliver higher photon flux density. A subject of particular interest is how to overcome beam profile modifications, namely the stripe patterns, induced by the reflection on a multilayer. For multilayer coatings in general it is known that the substrate and its surface quality significantly influence the performance of such kind of mirrors as the coating reproduces to a certain degree roughness and shape of the substrate. Our studies have shown that modified coatings can significantly change the impact of the multilayer reflection on the beam profile. We will present recent results as well as a critical review.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-T-05: Design of An Innovative Beam Monitor for Particle Therapy for the Simultaneous Measurement of Beam Fluence and Energy

Purpose: Monitoring the prescribed dose in particle therapy is typically carried out by using parallel plate ionization chambers working in transmission mode. The use of gas detectors has several drawbacks: they need to be calibrated daily against standard dosimeters and their dependence on beam quality factors need to be fully characterized and controlled with high accuracy. A detector capable of single particle counting is proposed which would overcome all these limitations. Combined with a gas ionization chamber, it will allow determining the average particle stopping power, thus providing an effective method for the online verification of the selected particle energy and range. Methods: Low-Gain Avalanche Detectors (LGADs) are innovative n-in-p silicon sensors with moderate internal charge multiplication occurring in the strong field generated by an additional p+ doping layer implanted at a depth of a few µm in the bulk of the sensor. The increased signal-to-noise ratio allows designing very thin, few tens of microns, segmented LGADs, called Ultra Fast Silicon Detectors (UFSD), optimized for very fast signal, which would be suitable for charged particle counting at high rates. A prototype UFSD is being designed for this purpose. Results: Different LGAD diodes have been characterized both in laboratory and beam tests, and the results compared both with those obtained with similar diodes without the gain layer and with a program simulating the signal in the sensors. The signal is found to be enhanced in LGADs, while the leakage current and the noise is not affected by the gain. Possible alternative designs and implementations are also presented and discussed. Conclusion: Thanks to their excellent counting capabilities, UFSD detectors are a promising technology for future beam monitor devices in hadron-therapy applications. Studies are ongoing to better understand their properties and optimize the design in view of this application.

61 RADIATION PROTECTION AND DOSIMETRY↗

Methods of optical diagnostics of electron-positron beams and interaction between plasma and high-current electron beam

Optical diagnostics is widely used, both in plasma-physics experiments and in measuring parameters of electron and positron beams in accelerators. In doing so, the approaches with the same methodological base are often applied, which is explained by similarity of certain properties of objects under study despite the fact that these fields of physics are absolutely specific and require using the specialized techniques. The possibility of close contacts and cooperation among scientists concerned with similar problems in different fields of physics contributes to the fruitful exchange of ideas and helps to overcome these problems. It is especially characteristic of the Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, which is famous for pioneering works in the field of electron-positron colliders and controlled thermonuclear fusion. The first part of this paper presents a review of optical diagnostics of the stationary beam parameters in cyclic accelerators of electrons and positrons. The only techniques considered are those that became the recognized tools at colliders and storage rings of the latest generation, without which the routine operation of the facility is difficult to imagine. The second part of the paper describes optical diagnostics used in experiments of heating the plasma by a high-current electron beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Image mapping for multiple charge state beams using a beam induced fluorescence profile monitors

Work continues on a minimally invasive, nitrogen fluorescence gas sheet at the Facility for Rare Isotope Beams (FRIB). A low density gas sheet may be used to observe the 2D transverse beam profile of high intensity, multiple charge state beams with minimal interference. Spatially and temporally correlated profiles are of particular interest in locations where there is significant charge state spread, such as the FRIB linac folding segments. A low-density gas sheet measurement system offers advantages for gas handling in nitrogen sensitive areas, however signal intensity is significantly lower than techniques using higher density gas sheets and jets. This work discusses measurement considerations for photon distributions generated by several spatially separated interaction points and design considerations for a high-sensitivity optics system for handling the expected low signal intensity.

Accelerator Physics↗