Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Cosolvent-tuned interactions in ionic liquids: A vibrational and quantum-chemical study of ethylene glycol ratio effects

Ionic liquids (ILs) are attractive media for CO 2 capture but remain limited by viscosity and cost. Blending ILs with ethylene glycol (EG) is a practical route to mitigate these constraints, yet the molecular origins of cosolvent effects and their dependence on composition are not well resolved. We combine Fourier-transform infrared (FT-IR) spectroscopy with quantum-chemical (DFT) analysis to elucidate how the IL:EG molar ratio modulates intermolecular interactions and electronic structure. Computed vibrational frequencies enable mode assignment and deconvolution of overlapping bands, revealing systematic, ratio-dependent shifts and broadenings in (i) EG O–H stretching, (ii) cation and EG C–H stretchings (imidazolium C2–H, C4–H, C5–H, methyl and ethyl groups, -CH2 of EG), (iii) anion signature modes (e.g., CN motifs), and (iv) EG C–O and C–C stretchings, consistent with the redistribution of hydrogen-bonding networks. Molecular electrostatic potential (MESP) maps quantify attenuation of extreme potential regions with increasing EG, indicating progressive screening of cation–anion electrostatic interactions. Quantum Theory of Atoms in Molecules (QTAIM) identifies emergent bond critical points between EG and the IL ions, while Reduced Density Gradient–Noncovalent Interaction (RDG–NCI) analysis differentiates strong directional hydrogen bonds from dispersive contacts across compositions. Together, these results show that EG fraction controls a switch from predominantly ion–ion to mixed ion–EG coordination, altering local polarity and polarizability that underlie the observed FT-IR trends. The framework provides composition–structure–spectrum relationships that can guide rational selection of IL:EG ratios to balance favorable molecular interactions with practical performance targets in scalable CO 2 capture systems.

DAC↗

In situ monitoring of microstructure evolution during thermal processing of uranium-zirconium alloys using laser-generated ultrasound

In this study, laser-generated ultrasound was used to monitor microstructure evolution during thermal processing of as-cast, polycrystalline binary uranium-zirconium metallic fuel alloys with compositions of U-20wt.%Zr (U-20Zr), U-50wt.%Zr (U-50Zr) and U-80wt.%Zr (U-80Zr). Ultrasonic waveforms were recorded during heating and cooling the samples from room temperature to >973 K and back. A phase transition temperature for all three compositions was estimated from the temperature at which an abrupt and rapid reduction in ultrasonic velocities was observed. Microstructural features on the length scale of tens of micrometers were inferred from the observation of scattering of ultrasonic waves by elastic heterogeneities above ~823 K in U-20Zr, while a hysteresis in the ultrasonic velocities of U-80Zr upon cooling was attributed to a partial retention of the high temperature phase following thermal annealing. The U-50Zr alloy exhibited a reversible viscoelastic response above 933 K, as evidenced by the observation of high frequency attenuation of the shear component of the waveforms at high temperature. Ultrasonic measurements were supplemented by in situ transmission electron microscopy (TEM). The TEM images revealed that the δ-U-Zr matrix in the three compositions underwent a spinodal decomposition above ~823 K into nanoscale regions. The ultrasonic measurements revealed larger, micron-scale structure evolution in the U-20Zr alloy at the same temperature. This large-scale structure is associated with heterogeneous regions having different Zr content. Our findings show the potential heating rate dependence of microstructural evolution in U-Zr alloys and highlight differences in the thermomechanical response and associated length scales during thermal annealing between single- and dual-phase compositions. These results demonstrate the utility of laser ultrasonics to rapidly and efficiently scan phase boundaries and monitor micrometer-scale structure evolution in metallic fuel alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optical vibrational spectra of β -U 3 O 8

Technogenic uranium oxides are ubiquitous in the nuclear fuel cycle. Identifying the chemical composition of these oxides is frequently done with optical vibrational spectroscopy (infrared and Raman spectroscopy). The α phase of U 3 O 8 is the most stable and common uranium oxide, but a β phase of U 3 O 8 can be produced via very slow cooling of the α phase from elevated temperatures or the application of small shear forces. However, optical spectra of this compound have not been reported. In this work, we use high-resolution attenuated total reflection infrared spectroscopy and Raman spectroscopy to collect the optical vibrational spectra. Despite similarities in the crystal structure of α and β – U 3 O 8 , the optical spectra of these compounds differ substantially, with additional Raman active modes in β – U 3 O 8 that are likely originating from differences in the U–O coordination units. Measurements presented here provide spectral characterization that can be used for chemical identification in future studies of uranium oxides.

36 MATERIALS SCIENCE↗

Correlative acoustic time-of-flight spectroscopy and X-ray imaging to investigate gas-induced delamination in lithium-ion pouch cells during thermal runaway

It remains difficult to detect internal mechanical deformation and gas-induced degradation in lithium-ion batteries, especially outside specialized diagnostics laboratories. In this work, we demonstrate that electrochemical acoustic time-of-flight (EA-ToF) spectroscopy can be used as an insightful and field-deployable diagnostic/prognostic technique to sense the onset of failure. A 210 mAh commercial lithium-ion cell undergoing thermal abuse testing is probed with in situ and operando EA-ToF spectroscopy, together with simultaneous fractional thermal runaway calorimetry (FTRC) and synchrotron X-ray imaging. The combination of X-ray imaging and EA-ToF analysis provides new understanding into the through-plane mechanical deformation in lithium-ion batteries through direct visualisation and the acoustic ToF response. Internal structural changes, such as gas-induced delamination, are identified using EA-ToF spectroscopy due to variations in the attenuation and signal peak shifts. This is corroborated using X-ray imaging, demonstrating EA-ToF spectroscopy as a promising technique for detecting onset of battery failure.

25 ENERGY STORAGE↗

A variance deconvolution estimator for efficient uncertainty quantification in Monte Carlo radiation transport applications

Monte Carlo simulations are at the heart of many high-fidelity simulations and analyses for radiation transport systems. As is the case with any complex computational model, it is important to propagate sources of input uncertainty and characterize how they affect model output. Unfortunately, uncertainty quantification (UQ) is made difficult by the stochastic variability that Monte Carlo transport solvers introduce. The standard method to avoid corrupting the UQ statistics with the transport solver noise is to increase the number of particle histories, resulting in very high computational costs. In this contribution, we propose and analyze a sampling estimator based on the law of total variance to compute UQ variance even in the presence of residual noise from Monte Carlo transport calculations. Here, we rigorously derive the statistical properties of the new variance estimator, compare its performance to that of the standard method, and demonstrate its use on neutral particle transport model problems involving both attenuation and scattering physics. We illustrate, both analytically and numerically, the estimator’s statistical performance as a function of available computational budget and the distribution of that budget between UQ samples and particle histories. We show analytically and corroborate numerically that the new estimator is unbiased, unlike the standard approach, and is more accurate and precise than the standard estimator for the same computational budget.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modular multi-interface nanocrystals for enhanced ethanol oxidation electrocatalysis

Electrochemical processes that utilize biomass-derived ethanol as a source of electrons and protons offer a sustainable energy strategy, yet their practical implementation is limited by sluggish ethanol oxidation reaction (EOR) kinetics and catalyst poisoning. Here, in this study, we report a modular multi-interface nanocrystal catalyst comprising core/shell Co 2 P/Pd and Pd-Au heterostructured interfaces that exhibit complementary functions for the enhanced EOR catalysis. The Co 2 P/Pd interface boosts Pd atom utilization and lowers the kinetic barriers for ethanol-to-acetate conversion, while the Pd-Au interface effectively alleviates CO poisoning caused by C–C bond cleavage of ethanol. In-depth analyses using in situ attenuated total reflectance-surface-enhanced infrared absorption spectroscopy, differential electrochemical mass spectrometry, and density functional theory calculations elucidate the mechanistic roles of these interfaces. The optimized Co 2 P/Pd-Au 0.08 nanorods achieve an excellent mass activity, underscoring the potential of modular, multi-interface nanocrystals for advancing EOR catalysis and offering a generalizable strategy for broader catalytic innovations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oxygen-deficient ammonium vanadate for flexible aqueous zinc batteries with high energy density and rate capability at -30 °C

Aqueous zinc batteries (AZBs) have received significant attention owing to environmental friendliness, high energy density and inherent safety. However, lack of high-performance cathodes has become the main bottleneck of AZBs development. Here, oxygen-deficient NH 4 V 4 O 10–x ·nH 2 O (NVOH) microspheres are synthesized and used as cathodes for AZBs. The experimental test and theoretical calculations demonstrate that the oxygen vacancies in the lattice lower the Zn 2+ diffusion energy barrier, which enables fast Zn 2+ diffusion and good electrochemical performance in a wide temperature range. The suppressed side reactions also can help to improve the low temperature performance. NVOH shows a high energy density of 372.4 Wh kg –1 and 296 Wh kg –1 at room temperature and –30 °C, respectively. Moreover, NVOH maintains a 100% capacity retention after 100 cycles at 0.1 A g –1 and ~94% capacity retention after 2600 cycles at 2 A g –1 and –30 °C. Investigation into the mechanism of the process reveals that the capacity contribution of surface capacitive behaviors is dominant and capacity attenuation is mainly caused by the decay of diffusion-controlled capacity. As a result, flexible AZBs can steadily power portable electronics under different bending states, demonstrating its great potential in wide-temperature wearable device.

25 ENERGY STORAGE↗

Itaconic acid production is regulated by LaeA in Aspergillus pseudoterreus

The global regulator LaeA controls secondary metabolism in diverse Aspergillus species. Here we explored its role in regulation of itaconic acid production in Aspergillus pseudoterreus. To understand its role in regulating metabolism, we deleted and overexpressed laeA, and assessed the transcriptome, proteome, and secreted metabolome prior to and during initiation of phosphate limitation induced itaconic acid production. We found that secondary metabolite clusters, including the itaconic acid biosynthetic gene cluster, are regulated by laeA and that laeA is required for high yield production of itaconic acid. Overexpression of laeA improves itaconic acid yield at the expense of biomass by increasing the expression of key biosynthetic pathway enzymes and attenuating the expression of genes involved in phosphate acquisition and scavenging. Increased yield was observed in optimized conditions as well as conditions containing excess nutrients that may be present in inexpensive sugar containing feedstocks such as excess phosphate or complex nutrient sources. This suggests that global regulators of metabolism may be useful targets for engineering metabolic flux that is robust to environmental heterogeneity.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of Histophilus somni sialic acid uptake mutant (Δ nanP -Δ nanU ) using a mouse septicemia and mortality model

Histophilus somni is an important pathogen of the bovine respiratory disease complex, yet the mechanisms underlying its virulence remain poorly understood. It is known that H. somni can incorporate sialic acid into lipooligosaccharide (LOS), and sialylated H. somni is more resistant to phagocytosis and complement-mediated killing by serum compared to non-sialylated bacteria in vitro. However, the virulence of non-sialylated H. somni has not been evaluated in vivo using an animal model. In this study, we investigated the contribution of sialic acid to virulence by constructing an H. somni sialic acid uptake mutant (ΔnanP-ΔnanU) and comparing the parent and mutant strains in a mouse septicemia and mortality model. Intraperitoneal challenge of mice with wildtype H. somni (1 × 10 8 colony forming units/mouse, CFU) was lethal to all animals. Mice challenged with three different doses (1, 2, or 5 × 108 CFU/mouse) of an H. somni ΔnanP-ΔnanU sialic acid uptake mutant exhibited survival rates of 90 %, 60 %, and 0 % respectively. High-performance anion exchange chromatography analyses revealed that LOS prepared from both parent and the ΔnanP-ΔnanU mutant strains of H. somni were sialylated. These findings suggest the presence of de novo sialic acid synthesis pathway, although the genes associated with de novo sialic acid synthesis (neuB and neuC) were not identified by genomic analysis. The lower attenuation in mice is most likely attributed to the sialylated LOS of H. somni nanPU mutant.

59 BASIC BIOLOGICAL SCIENCES↗

Mechanistic insights into the colloidal assembly of mesoporous silica using in-operando cross-scale X-ray scattering and spectroscopic measurements

Advancing a mechanistic understanding of the colloidal to solid-phase transformations of silica allows us to tune these meso-scale structures. In this study, we probe the structural transformations associated with the formation of mesoporous silica particles, SBA-15 using in-operando Small Angle X-ray Scattering (SAXS) and Grazing Incidence-Small Angle X-ray Scattering (GI-SAXS). The chemical transformations associated with the hydrolysis and condensation of silica particles is investigated using Attenuated Total Reflection – Fourier Transform Infrared Spectroscopy (ATR-FTIR) measurements. Fast polymerization of Si-O-Si species to form mesoporous silica is noted when SBA-15 is synthesized in the presence of nitrate salts, due to the “salting-in” effect or enhanced solubility of polymers. However, aging the silica particles resulted in plate-like morphologies in the absence of the nitrate salt and spherical morphologies in the presence of nitrate salt. Early onset of nucleation of silica particles in the presence of nitrate salts was captured using GI-SAXS measurements. These studies show that the rational basis for developing new synthesis routes for accelerated kinetics or specific meso-scale structures can be informed by detailed characterization of the evolution in chemistry and meso-scale structure of these materials.

36 MATERIALS SCIENCE↗

Comprehensive defect evaluation of advanced nuclear fuels using high-resolution acoustic signals and optimized sensor separation

Graphite pebble composite structures based on TRistructural-ISOtropic (TRISO) particles are being developed as core nuclear fuels in advanced power reactors, promising safe operation at increased temperatures. Ensuring the structural integrity of these nuclear fuels requires comprehensive and accurate non-destructive evaluation (NDE) techniques to characterize defects and damage in the pebbles. However, traditional acoustic evaluation methods face limitations in defect characterization due to the highly attenuative, and geometrically and compositionally complex nature of these structures. This study proposes an improved acoustic NDE technique for accurate detection and classification of anticipated relevant defects and damage in graphite pebbles using high-resolution acoustic signals and optimized transmit-receive sensor networks. The proposed approach utilizes a triangular three-sensor network as the base unit, comprising three transmit-receive sensors. The sensor separation distance, as well as acoustic excitation center frequency, pulse-width, and bandwidth are optimized to enhance spatial resolution and improve signal-to-noise ratio, enabling effective characterization of the smallest size and widest range of defects in pebbles. Furthermore, the use of the triangular sensor configuration instead of a more conventional transmit-receive sensor pair expands the inspection region from a one-dimensional linear path to a two-dimensional area, increasing spatial coverage. To mitigate challenges associated with processing of complex acoustic signals arising from high-frequency, high-bandwidth excitation in these structures, a machine-learning-based signal processing algorithm is integrated with the sensor network. In the machine-learning-based algorithm, multi-domain features are extracted from the acoustic signals to capture intricate signal characteristics, significantly improving defect identification and classification compared to traditional approaches. The proposed acoustic NDE technique offers considerable promise for practical and reliable defect/damage diagnostics of advanced nuclear pebble fuels.

42 ENGINEERING↗

Applications of HPGe-detected high energy gamma rays toward quantifying neutron emission rates and 234 U enrichment in UF 6 cylinders

This study presents a 234 U enrichment meter that uses high energy gamma and neutron count rate as measured by a portable, high-purity germanium gamma ray detector. Twenty-one 30B cylinders containing UF 6 of varying origin were analyzed with an HPGe detector for high-energy gamma ray and neutron counts. Excellent correlations (R 2 0.95) between various regions of 3.0 MeV gamma rays, neutron count rate, and uranium enrichment were found. These neutron and high-energy gamma data are used to create calibration-dependent enrichment meters for 234 U. The 234 U enrichment calculated from the neutron count rate and 4 – 6 MeV gamma count rate is more accurate than methods that rely on the 120.9 keV peak which is strongly attenuated inside commercial sized UF 6 cylinders. These neutron and high-energy gamma enrichment calculators can also be used to determine a 235 U enrichment, assuming mass-based enrichment from natural uranium, but the results are not as accurate as the traditional 185.7 keV peak enrichment meter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon detector response function methodology using MCNP and shift hybrid radiation transport code for wide-area contamination assay applications

Here, radiation transport modeling using the Monte Carlo N-Particle (MCNP) radiation transport code and Monte Carlo code, Shift, were employed to model detector responses for a variety of wide-area photon contamination scenarios. In this study, 2" × 2" and 3" × 3" cylindrical NaI(Tl) scintillation detector configurations at source detector-distances of 0.5 cm, 1 cm, 2.54 cm, 10 cm, and 30 cm were modeled. Media of soil, concrete, and steel were evaluated for contamination depths ranging from surface to a depth of an infinite thickness in each medium for photon energies ranging from 20 keV to 3 MeV, which correspond to the energies that current detectors can discern. Monoenergetic photon surface contamination detector responses for each of the media, source–detector distances, and detectors were estimated using MCNP v6.2. Shift was harnessed for improved variance reduction of particle transport in highly attenuating media to obtain average cell fluxes in the two MCNP NaI(Tl) scintillation detector configurations. Average cell flux values in Shift were coupled with detector responses from MCNP to convert average cell flux in a void to energy distribution of pulses in the NaI(Tl) scintillation detector crystal of interest. An optimized detector response function methodology was developed by coupling the MCNP radiation transport method with the Consistent Adjoint Driven Importance Sampling (CADIS) hybrid radiation transport method built into Shift to significantly decrease the runtime of thousands of MCNP pulse height simulations. The methodology may be utilized to quickly and accurately facilitate the assessment of a broad range of wide-area environmental contamination assay and decommissioning cleanup applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CLARION2-TRINITY: A Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminum Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7–54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $\gamma$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors (efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Lastly, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from 16 O + 18 O fusion-evaporation, and PID and Doppler-corrected -ray spectra from 48 Ti + 12 C Coulomb excitation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact light shield for the Psyche gamma-ray spectrometer

A compact, low-mass light shield has been designed for the Psyche space mission high-purity germanium gamma-ray spectrometer. The spectrometer will be vented to space, which can allow solar photons to enter the cryostat and cause charge-induced noise. The light shield was designed to block more than 99.9% of solar photons while maintaining high molecular conductance to space vacuum. COMSOL simulations and experiments were performed to characterize light shield photon attenuation and molecular conductance. Finally, the light shield was integrated onto the gamma-ray spectrometer and photon suppression and vacuum performance were demonstrated.

(16) Psyche↗

Fast-neutron/gamma-ray radiography using a broad-energy neutron source

Transmission radiography is a well-established nondestructive examination technique with widespread application to fields ranging from medicine to security. Traditionally, inspection is performed using a single particle type (such as x-rays). However, the information available using a single probe for traditional radiography is limited. The present work evaluates material discrimination via transmission radiography using the attenuation ratio of monoenergetic gamma rays to a broad spectrum of fast neutrons. Here, the method was assessed using an 241 Am/Be radioisotope source that provides both 4.4 MeV gamma rays and a spectrum of fast neutrons up to 12 MeV. A total of 14 object configurations were measured: seven different materials each with two thicknesses (2.5 cm and 5 cm). The ability to distinguish materials was evaluated and shows more significant variation among atomic numbers than for high-energy x-rays alone, making it easier to distinguish between classes such as low-, mid-, and high-Z materials. These results suggest that superior material discrimination is also possible using a combination of monoenergetic gamma rays and broad-spectrum fast neutrons from a variety of nuclear reactions, such as 11 B(d,nγ) 12 C, that could be implemented in future inspection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation for correlated prompt n – γ emission studies in coincidence with fission fragments

Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and n – γ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty trans-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and γ-ray multiplicities and spectra. Here, the details of both detector assemblies are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗