Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arrival time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Search for bursts in air shower data

There have been reports in recent years of the possible observation of bursts in air shower data. If such events are truly of an astrophysical nature then, they represent an important new class of phemonenon since no other bursts have been observed above the MeV level. The spectra of conventional gamma ray bursts are unknown at higher energies but their observed spectra at MeV energies appear generally to exhibit a steepening in the higher MeV range and are thus unlikely to extrapolate to measurable fluxes at air shower energies. An attempt has been made to look for deviations from randomness in the arrival times of air showers above approx. 10 to the 14th power eV with a number of systems and results so far are presented here. This work will be continued for a substantial period of ime with a system capable of recording bursts with multiple events down to a spacing of 4 microns. Earlier data have also been searched for the possible association of air shower events with a glitch of the Vela pulsar.

Bruce, T. E. G.↗

Mini and super mini arrays for the study of highest energy cosmic rays

The chief difficulty in studying the highest energy cosmic rays is the extremely low intensity, only approximately 5 particles per sq km sr century above 10 to the 20th power eV. Instead of attacking the problem by assembling all of the available resources in one place, as has been done in the past, a way that the task can be performed at much less cost per unit sensitive area is suggested, by using numerous inexpensive mini arrays operating independently of each other. In addition to the quantities usually observed, each mini array will record shower particle arrival time distributions. At 10 to the 20th power eV the saving in cost per primary particle is estimated to be a factor of 10 or better, compared to methods now in use, even for mini arrays newly built from scratch for just this purpose.

Linsley, J.↗

Shower disc sampling and the angular resolution of gamma-ray shower detectors

As part of the design study for the new UHE gamma ray detector being constsructed at Haverah Park, a series of experiments using scintillators operated side-by-side in 10 to the 15th power eV air showers are undertaken. Investigation of the rms sampling fluctuations in the shower disc arrival time yields an upper limit to the intrinsic sampling uncertainty, sigma sub rms = (1.1 + or - 0.1)ns, implying an angular resolution capability 1 deg for an inter-detector spacing of approximately 25 m.

Lambert, A.↗

A new approach to evaluate gamma-ray measurements

Misunderstandings about the term random samples its implications may easily arise. Conditions under which the phases, obtained from arrival times, do not form a random sample and the dangers involved are discussed. Watson's U sup 2 test for uniformity is recommended for light curves with duty cycles larger than 10%. Under certain conditions, non-parametric density estimation may be used to determine estimates of the true light curve and its parameters.

Dejager, O. C.↗

Muon fluctuation studies of EAS 10(17) eV

Fluctuation studies need to compare a parameter which is sensitive to longitudinal fluctuations against a parameter which is insensitive. Cascade calculations indicate that the shower size parameter at Haverah Park, rho (500), and the muon density are insensitive while parameters that significantly reflect the longitudinal development of a particular extensive air shower (EAS) include the muon/water Cerenkov response ratio and the muon arrival time dispersion. This paper presents conclusions based on muon fluctuation studies of EAS measured between 1976 and 1981 at Haverah Park.

Blake, P. R.↗

The structure of the shower disk observed at Mt. Norikura

The structure of the EAS shower disk, the arrival time distribution of charged particles at the core of the small or middle size shower, is measured at Mt. Norikura in Japan. Four fast scintillation counters with an area of 0.25 sq m and a fast trigger system are added to the Mt. Norikura EAS array for the study.

Sasaki, H.↗

Structure of air shower disc near the core

The longitudinal structure of the air shower disk is studied by measuring the arrival time distributions of air shower particles for showers with electron size in the range 3.2 x 10 to the 5.5. power to 3.2 x 10 to the 7.5 power in the Akeno air-shower array (930 gcm squared atmospheric depth). The average FWHM as a parameter of thickness of air shower disk increases with core distances at less than 50m. AT the present stage, dependence on electron size, zenith angle and air shower age is not apparent. The average thickness of the air shower disk within a core distance of 50m could be determined by an electromagnetic cascade starting from the lower altitude.

Inoue, N.↗

Properties of 10 (18)-10 (19)eV EAS at far core distance

The properties of 10 to the 18th power - 10 to the 19th power eV EAS showers such as the electron lateral distribution, the muon lateral distribution ( 1Gev), the ratio of muon density to a electron density, the shower front structure and the transition effects in scintillator of 5cm thickness are investigated with the Akeno 4 sq km/20sq km array at far core distances between 500m and 3000m. The fluctuation of densities and arrival time increase rapidly at core distances greater than 2km.

Teshima, M.↗

Methods for roof-top mini-arrays

To test the idea of the Linsley effect mini array for the study of giant air showers, it is desirable to have a trigger that exploits the effect itself. In addition to the trigger, it is necessary to have a method for measuring the relative arrival times of the particle swarm selected by the trigger. Since the idea of mini arrays is likely to appeal to small research groups, it is desirable to try to design relatively simple and inexpensive methods, and methods that utilize existing detectors. Clusters of small detectors have been designed for operation in the local particle density realm where the probability of or = 2 particles per detector is small. Consequently, this method can discriminate pulses from each detector and thenceforth deal mainly with logic pulses.

Hazen, W. E.↗

Thickness of the particle swarm in cosmic ray air showers

The average dispersion in arrival time of air shower particles detected with a scintillator at an impact parameter r is described with accuracy 5-10% by the empirical formula sigma = Sigma sub to (1+r/r sub t) sup b, where Sigma sub to = 2.6 ns, r sub t = 30m and b = (1.94 + or - .08) (0.39 + or - .06) sec Theta, for r 2 km, 10 to the 8th power E 10 to the 11th power GeV, and Theta 60 deg. (E is the primary energy and theta is the zenith angle). The amount of fluctuation in sigma sub t due to fluctuations in the level of origin and shower development is less than 20%. These results provide a basis for estimating the impact parameters of very larger showers with data from very small detector arrays (mini-arrays). The energy of such showers can then be estimated from the local particle density. The formula also provides a basis for estimating the angular resolution of air shower array-telescopes.

Linsley, J.↗

Type III radio bursts in the interplanetary medium - The role of propagation

Interplanetary type III radio burst observations are analyzed in order to ascertain the role played by propagation effects between the true source and the observer. Large source altitudes are noted, together with an increasing angular size of sources with increasing angular distance from the sun's center. These and other observations furnish strong evidence for the theory that propagation effects, group delays, ducting and/or scattering significantly affect the observed heights, sizes, and brightness temperatures of interplanetary type III bursts. This would be true irrespective of whether the bursts are due to plasma radiation at the fundamental or at the harmonic, and the effects would extend to the arrival times of the radiation to a greater or lesser extent, depending on the path from the source to the observer.

Steinberg, J. L.↗

Gamma rays of 1-30 MeV from the Galactic Center Region

Preliminary results are reported for gamma rays from the Galactic Center Region at 1-30 MeV made with a balloon-borne double Compton scatter gamma ray telescope. The Compton scatter angle, energy, and arrival time of the incident gamma ray and direction of the Compton scattered secondary for downward-moving gamma rays were measured. The handling of the data is described, and the results of Monte Carlo simulation angular resolutions and absolute efficiencies for different zenith angles of incident gamma rays are given. A contour sky map of the weighted fluxes for a southern sky region is shown whose primary feature is a significant enhancement in the Galactic Center Region. It is concluded that several discrete sources contribute to broaden the maximum in the horizontal or RA direction. Less broadening is indicated along the galactic plane.

Oneill, T.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Detector systems based on the high gain microchannel plate (MCP) electron multiplier were used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse counting electronic readout systems provide zero readout noise, spatial resolutions (FWHM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can be developed to produce detectors with active areas of 100 nm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies at wavelengths between about 100 and 1A (approximately 0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described and the prospects for future developments are discussed.

Timothy, J. G.↗

Orbital elements of the binary X-ray pulsar GX 301-2

X-ray outbursts from GX 301-2 were observed with Hakucho on two occasions during April and May 1982 and with Tenma in April 1984. Pulse arrival times measured with Hakucho were combined with those previously measured with Ariel 5 and SAS 3. The joint timing analysis of these data sets yields an orbital period of 41.5 days as the only acceptable solution; this is consistent with the period derived from the X-ray flaring events of the source. The orbital elements of the binary system, established from the joint timing analysis, are presented. The orbital solution suggests that all the peaks of X-ray flares observed during the past 10 yr occur at the orbital period, but consistently appear about 1.4 days before the time of periastron passage of the X-ray star.

Sato, N.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.↗

A low-cost optical data acquisition system for vibration measurement

A low cost optical data acquisition system was designed to measure deflection of vibrating rotor blade tips. The basic principle of the new design is to record raw data, which is a set of blade arrival times, in memory and to perform all processing by software following a run. This approach yields a simple and inexpensive system with the least possible hardware. Functional elements of the system were breadboarded and operated satisfactorily during rotor simulations on the bench, and during a data collection run with a two-bladed rotor in the Lewis Research Center Spin Rig. Software was written to demonstrate the sorting and processing of data stored in the system control computer, after retrieval from the data acquisition system. The demonstration produced an accurate graphical display of deflection versus time.

Posta, S. J.↗

Microchannel plates and image detection at soft X-ray wavelengths

Detector systems based on the high-gain microchannel plate (MCP) electron multiplier have been used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse-counting electronic readout systems provide zero readout-noise, spatial resolutions (FWM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can br developed to produce detectors with active areas of 100 mm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies to wavelengths between about 100 and 1A (0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described, and the prospects for future developments are discussed.

Timothy, J. G.↗

Three-dimensional P and S wave velocity structures of southern Peru and their tectonic implications

Arrival times of compressional and shear (S) waves from microearthquakes recorded in 1981 by an 18-station regional array are used to study the three-dimensional velocity structure of the crust and upper mantle of the central Andes. The data suggest a crustal thickness of about 40 km beneath the coast, increasing to about 70 km beneath the Cordillera Occidental. The inverse correlation between the dip in the Moho and the dip of the slab may indicate a broad-scale causal relation between the two. S wave velocities in the mantle between 70 and 130 km depth above the 30-degree dipping slab are low, possibly indicating the presence of a partially melted asthenosphere that may be responsible for the magmatic activity recorded in southern Peru.

Cunningham, Paul S.↗