Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ablator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Overview of the CHarring Ablator Response (CHAR) Code

An overview of the capabilities of the CHarring Ablator Response (CHAR) code is presented. CHAR is a one-, two-, and three-dimensional unstructured continuous Galerkin finite-element heat conduction and ablation solver with both direct and inverse modes. Additionally, CHAR includes a coupled linear thermoelastic solver for determination of internal stresses induced from the temperature field and surface loading. Background on the development process, governing equations, material models, discretization techniques, and numerical methods is provided. Special focus is put on the available boundary conditions including thermochemical ablation and contact interfaces, and example simulations are included. Finally, a discussion of ongoing development efforts is presented.

Amar, Adam J.↗

Laser Surface Preparation of Epoxy Composites for Secondary Bonding: Optimization of Ablation Depth

Surface preparation has been identified as one of the most critical aspects of attaining predictable and reliable adhesive bonds. Energetic processes such as laser ablation or plasma treatment are amenable to automation and are easily monitored and adjusted for controlled surface preparation. A laser ablation process was developed to accurately remove a targeted depth of resin, approximately 0.1 to 20 micrometers, from a carbon fiber reinforced epoxy composite surface while simultaneously changing surface chemistry and creating micro-roughness. This work demonstrates the application of this process to prepare composite surfaces for bonding without exposing or damaging fibers on the surface. Composite panels were prepared in an autoclave and had a resin layer approximately 10 micrometers thick above the fiber reinforcement. These composite panels were laser surface treated using several conditions, fabricated into bonded panels and hygrothermally aged. Bond performance of aged, experimental specimens was compared with grit blast surface treated specimens using a modified double cantilever beam test that enabled accelerated saturation of the specimen with water. Comparison of bonded specimens will be used to determine how ablation depth may affect average fracture energies and failure modes.

Palmieri, Frank L.↗

Picosecond Pulsed Laser Ablation for the Surface Preparation of Epoxy Composites

As part of a technical challenge under the Advanced Composites Program, methods for improving pre-bond process control for aerospace composite surface treatments and inspections, in conjunction with Federal Aviation Administration guidelines, are under investigation. The overall goal is to demonstrate high fidelity, rapid and reproducible surface treatment and surface characterization methods to reduce uncertainty associated with the bonding process. The desired outcomes are reliable bonded airframe structure, and reduced timeline to certification. In this work, laser ablation was conducted using a q-switched Nd:YVO4 laser capable of nominal pulse durations of 8 picoseconds (ps). Aerospace structural carbon fiber reinforced composites with an epoxy resin matrix were laser treated, characterized, processed into bonded assemblies and mechanically tested. The characterization of ablated surfaces were conducted using scanning electron microscopy (SEM), water contact angle (WCA) goniometry, micro laser induced breakdown spectroscopy (uLIBS), and electron spin resonance (ESR). The bond performance was assessed using a double cantilever beam (DCB) test with an epoxy adhesive. The surface characteristics and bond performance obtained from picosecond ablated carbon fiber reinforced plastics (CFRPs) are presented herein.

Palmieri, Frank↗

Specific Impulse of Electric Solid Propellant in an Electrothermal Ablation-Fed Pulsed Plasma Thruster

Electric solid propellants are advanced solid chemical rocket propellants that can be controlled (ignited, throttled, and extinguished) through the application and removal of an electric current. Recent work has focused on application of this propellant in an electrothermal ablation-fed pulsed plasma thruster. In this paper, impulse bit measurements in such devices fed by either the electric solid propellant or a traditional state-of-the-art propellant, polytetrafluoroethylene, are expanded upon. It is demonstrated that a surface layer in the hygroscopic electric solid propellant is rapidly ablated over the first few discharges of the device, which correspondingly decreases specific impulse relative to the traditional polytetrafluoroethylene propellant. Correcting these data by subtracting the early discharge ablation mass loss measurements yields a corrected electric solid propellant specific impulse of approximately 300 s. As the test duration increases to a large number of discharges, and the initial mass loss is a reduced fraction of the total, the effect of absorbed water in the propellant is decreased and the specific impulse without any corrections approaches the corrected 300 s value.

Glascock, Matthew S.↗

Progress Towards Modeling the Ablation Response of NuSil-Coated PICA

The Mars Science Laboratory (MSL) Entry, Descent and Landing Instrumentation (MEDLI) collected in-flight data largely used by the ablation community to verify and validate physics-based models for the response of the Phenolic Impregnated Carbon Ablator (PICA) material [1-4]. MEDLI data were recently used to guide the development of NASA’s high-fidelity material response models for PICA, implemented in the Porous material Analysis Toolbox based on OpenFOAM (PATO) software [5-6]. A follow-up instrumentation suite, MEDLI2, is planned for the upcoming Mars 2020 mission [7] after the large scientific impact of MEDLI. Recent analyses performed as part of MEDLI2 development draw the attention to significant effects of a protective coating to the aerothermal response of PICA. NuSil, a silicone-based overcoat sprayed onto the MSL heatshield as contamination control, is currently neglected in PICA ablation models. To mitigate the spread of phenolic dust from PICA, NuSil was applied to the entire MSL heatshield, including the MEDLI plugs. NuSil is a space grade designation of the siloxane copolymer, primarily used to protect against atomic oxygen erosion in the Low Earth Orbit environment. Ground testing of PICA-NuSil (PICA-N) models all exhibited surface temperature jumps of the order of 200 K due to oxide scale formation and subsequent NuSil burn-off. It is therefore critical to include a model for the aerothermal response of the coating in ongoing code development and validation efforts.

Meurisse, Jeremie B.↗

Segmentation of Lightweight Ablator Micro-Tomography Using Deep Learning

Ablative thermal protection systems (TPS) are essential for high speed entry of planetary atmospheres, such as those of Earth and Mars. Upon entry the kinetic energy of the spacecraft is converted into thermal energy, leading to high heat fluxes at the wall of the craft. Because of this extreme heating, a robust ablative TPS material must be selected. A common material selection today is phenolic-impregnated carbon ablator (PICA), which is a low-density carbon material known for producing dust that is not suitable to a cleanroom environment. To mitigate dust created by a PICA heatshield, a silicone-based spray called NuSil is applied to the surface of the TPS, creating PICA-NuSil (PICA-N). PICA-N has been observed to have a different material response from regular PICA during high enthalpy flow testing, producing surface temperatures up to 200K less than those seen for PICA [1]. To better understand this phenomenon, it is critical that robust methods of PICA-N material characterization are developed. The purpose of this project is to investigate Object Research Systems’ (ORS) Dragonfly deep learning tools as a means of accurately segmenting and characterizing PICA-N. Systematic testing of this software has shown that Dragonfly deep learning tools have strong potential for accurate segmentation/ characterization of PICA-N and other TPS materials.

Micro-tomography↗

Meteorite Ablation at the HYMETS ARC-JET Facility

One of the primary goals of the Asteroid Threat Assessment Program (ATAP) is to understand the ablation phenomena of meteors (e.g., spallation, evaporation, melt flow, etc.). Therefore, a test campaign was executed at the Hypersonic Material Test System (HYMETS) facility on samples of an ordinary chondrite (e.g., Tamdakht) and samples of basalt from the Columbia plateau. High melt viscosities and low ablation rates are predicted for basalt due to higher concentrations of silica and alumina in the matrix phase. However, high-speed video and post-test analysis reveal that basalt experiences greater rates of ablation than Tamdakht. Post-test analysis of emission spectra reveals the presence of volatile species that may explain the discrepancy between model predictions and observed phenomena.

Meteor↗

Critical Ablative TPS Capabilities Sustainment - An Approach to Playing the Long Game

Historically, we have been pound foolish and penny wise for decades, and it is time to reverse this. We present an approach that will maintain critical NASA ablative TPS capabilities through small, sustained, smart and targeted investment. NASA’s ablative TPS history is one of developing new capabilities and letting them atrophy. When needed, there are two options: (1) revive the capability at considerable cost impact or (2) develop an alternate capability with considerable schedule impact. Either of these options have had considerable mission impact. The third alternate is to maintain proven capabilities in a cost effective manner to allow the science community to propose missions with confidence. NASA and DoD have had a working group to periodically assess and make recommendations on at-risk items. This working group typically focuses on raw materials availability. While we agree that at-risk raw materials are an important and necessary part of the overall capability, focus solely on them is not sufficient. Instead, we advocate for a broader focus on the critical “technology capability” that includes not only raw material but also industrial manufacturing and processing capabilities and in-house expertise in design, testing and flight hardware certification. In this proposed presentation, we will highlight a case study related to PICA capability. We will present the rationale for sustaining PICA and HEEET as two minimum essential ablative TPS capabilities for future NASA missions. We will present an approach for how small investment could lead to maintaining mission critical capabilities over a longer period. While HEEET and PICA are NASA unique, the raw material and some of the vendor capabilities involved also support DoD TPS. Hence a partnership between NASA and DoD is recommended for broader benefit.

Ethiraj Venkatapathy↗

MEDLI2: Ablator Models for Flight

During the entry of Mars Science Laboratory (MSL) the heatshield was equipped with the instrumentation suite Mars Entry, Descent, and Landing Instruments (MEDLI). In-depth thermocouple (TC) data was used to reconstruct the surface heating[1,2]. Discrepancies between MEDLI’s flight heating data and predicted thermal response and recession[3] led to a campaign to characterize and test Mars2020 and MEDLI2 (Mars Entry, Descent, and Landing Instrument 2)[4] flight-lot thermal protection materials (TPS) at relevant ground test conditions. This paper covers the development and validation of flight-lot material response models for the heatshield material Phenolic Impregnated Carbon Ablator (PICA) and the backshell material SLA-561V (Super Lightweight Ablator). Virgin and char properties such as thermal conductivity and emissivity were updated as a function of temperature and pressure in the MEDLI2 specific material response models. Other material properties were characterized and determined to be similar to prior TPS material measurements used for the heritage models. MEDLI2 also investigated the impact of the protective coating that was applied to MSL and Mars2020’s PICA heatshield to reduce the particulate matter shedding. Evidence from arc jet experiments on coated PICA showed that although there were no adverse effects on the performance of the TPS, there were differences in the in-depth temperatures and reduced recession compared to material response predictions of uncoated PICA.[5,6]. Fully Implicit Ablation and Thermal response (FIAT)[7] material response simulations were conducted with the heritage and MEDLI2 flight-lot material models. FIAT-predicted in-depth temperature responses and recession predictions were compared to flight-lot certification ground-test arc jet test data and MEDLI2 thermocouple data.

Materials Response↗

Ablative TPS Sustainment to Enable NASA's Future Robotic Missions

Since 1960s NASA’s missions have spanned the entire solar system, from Apollo to Jupiter entry ~50 km/s. Ablative TPS has been critical to the success. NASA’s missions will continue to be innovative, one-of-a kind and at the same time, competed mission selection process requires technology readiness to be high to ensure cost and risks are better understood. If missions require new TPS technology, it takes a decade and significant resources to develop them. Competitive proposal tend to use existing ablative TPS. Sustainability of ablative TPS is then essential. This talk will focus on approaches to address the future challenges.

Ethiraj Venkatapathy↗

Qualification of Domestic Lyocell Based Phenolic Impregnated Carbon Ablator (PICA-D) for NASA Missions

Phenolic Impregnated Carbon Ablator (PICA) is a low-density ablator that has been used as the planetary entry heatshield for several NASA missions since the late 90’s. Its low density and efficient performance characteristics have proven effective for use from Discovery to Flag-ship class missions, from Sample Return missions such as Stardust, OSIRIS-REx to large Mars Lander missions such as Mars Science Lab (MSL) and Mars 2020. The rayon-based carbon precursor raw material used in PICA preform manufacturing has experienced multiple supply chain issues. The challenge involved in finding a replacement fiber source is in processing as well as in the final performance of the ablator. Each replacement necessitates the requalification of the PICA. This has happened at least twice in the past 25 years, and a third substitution is now needed. Due to the obsolescence of the input foreign rayon fiber source, a new variant of PICA has been developed using a domestic rayon-like fiber source, Lyocell. Due to its flight heritage and proven capability, PICA is baselined as the Thermal Protection System (TPS) for Dragonfly and Mars Sample Return Sample Retrieval Lander mission and is being considered for the backshell of the Mars Sample Return Earth Entry System. All three missions are due to be launched between 2026 and 2028. The challenge this time is to ensure the PICA made with domestic material is a suitable replacement to the heritage PICA used in MSL and Mars 2020 so that the design of the heatshield can be matured without much risk. Results are presented from the recent efforts of 22 PICA-D billets that were Lot Acceptance Tested. Thermal, mechanical, and representative environment arc-jet tests have been conducted. Testing of PICA-Domestic (PICA-D) indicates very comparable performance with respect to “heritage” PICA materials and thus PICA-D is expected to be a sustainable and nearly a “drop-in” replacement solution for future NASA missions.

Matt Gasch↗

Simulating Ordinary Chondrite (Tamdakht) Ablation at the Hypersonic Materials Environmental Test System (HyMETS) Facility.

NASA’s Science Mission Directorate (SMD) created the Asteroid Threat Assessment Project (ATAP) to inform decision-makers of risks associated with Potentially Hazardous Objects (PHOs), which may pose an existential threat to human civilization. ATAP assesses risk, in part, by developing analytical physics-based damage models which draw upon data collected during material property characterization efforts, entry simulations, hazard simulations, and ground-based arc-jet testing. Therefore, a pathfinder test campaign was con-ducted at the Hypersonic Materials Environmental Test System (HyMETS) at the NASA Langley Re-search Center to investigate the ablation mechanisms of an ordinary chondrite (Tamdakht H5) and a terrestrial analog (basalt). The HyMETS facility is a 400 kW constricted arc heater used to screen material performance under simulated aerothermal conditions of hypersonic flow.1 Facility conditions were chosen to simulate Earth entry conditions be-tween the upper-mesosphere and the lower thermo-sphere. The ablation mechanisms of Tamdakht and bas-alt are illustrated with still images collected from high-speed video cameras (fig. 1, Tamdakht). Tamdakht produces a relatively stable melt flow, as evidenced by the perpetual growth of a flange at the sidewall and the exiguous detachment of molten material into the flow. Furthermore, an inspection of high-speed video and chemical analysis of the post-test melt layer suggests that the dominant mode of mass loss for Tamdakht, at these test conditions, is expressed through the vaporization of volatiles (e.g., iron, potassium, sodium, phosphorus, and sulfur). The vaporization rates of Tamdakht are greater than basalt under the most extreme test conditions, which leads to an enhanced blowing layer, in-creased thermal shielding, and reduced recession. The ablation mechanisms of basalt are markedly different from Tamdakht and are attributed to the presence of hydrated minerals dispersed at irregular intervals throughout the silicate matrix. Rapid de-composition of secondary minerals and the subsequent formation of water lead to the ejection of the subsurface and overlying melt layer. Furthermore, the presence of water is suspected of lowering the viscosity of the melt layer resulting in increased mass loss near the edge of the test article where drag forces overcome rheological properties (fig. 1, bas-alt). Finally, the results will be discussed in the broader context of meteorite-based material response model development and the potential impact on the Asteroid Threat Assessment Project (ATAP).

Brody K. Bessire↗

Investigating Material Behavior in Atmospheric Entry Conditions: Arc-Jet Testing Insights from Meteorite Ablation to High-Temperature Coatings.

Arc-jet testing is an indispensable tool in elucidating the complex interactions materials undergo when subjected to the extreme thermal and mechanical stresses of atmospheric entry. By replicating these harsh conditions, arc-jets enable researchers to explore critical phenomena such as ablation, melting, and spallation, generating invaluable data that informs the development of sophisticated, physics-based models. These models are pivotal not only in predicting material performance for spacecraft re-entry systems but also in assessing the threat posed by celestial bodies as they encounter Earth’s atmosphere. One of the leading facilities for such investigations is the Hypersonic Materials Environmental Test System (HyMETS) at NASA’s Langley Research Center. A pioneering test campaign conducted at HyMETS focused on unraveling the ablation mechanisms of an ordinary chondrite meteorite (Tamdakht H5) and a terrestrial analog (basalt). These studies unveiled distinct material behaviors: Tamdakht demonstrated a remarkably stable melt flow, with mass loss primarily driven by the volatilization of elements such as iron and sodium, whereas basalt exhibited more aggressive surface degradation due to the rapid decomposition of hydrated minerals, culminating in significant spallation and surface material ejection. Beyond meteorite analysis, HyMETS has also been integral in the exploration of advanced Thermal Protection Systems (TPS) such as Phenolic Impregnated Carbon Ablator (PICA), a material with extensive flight heritage in missions like Stardust, Mars Science Laboratory, Mars 2020, and Osiris-REx. PICA, when coated with NuSil CV-1144-0—a polysiloxane resin designed to prevent particle shedding—undergoes a remarkable transformation upon heating. The resin pyrolyzes to form a thin, oxidation-resistant silicon oxycarbide layer that profoundly influences the material’s thermal response through a sophisticated four-stage process. Initially, the silicon oxycarbide acts as a formidable barrier, impeding reactive interactions with the PICA char and effectively suppressing surface temperature rise and material recession. However, as the heating persists, the protective layer decomposes via carbothermal reduction, exposing the underlying char, which in turn leads to a dramatic spike in surface temperature and accelerated material erosion. In the final stage, equilibrium is reached, with recession rates aligning with those of the virgin material. This intricate understanding of PICA-NuSil behavior under extreme conditions offers valuable insights, enhancing material response models and advancing the development of next-generation TPS for space exploration.

Chemistry↗

Femtosecond filament-laser ablation molecular isotopic spectrometry

A new remote sensing technology for real-time isotopic analysis is introduced: Femtosecond Filament-Induced Laser Ablation Molecular Isotopic Spectrometry (F 2 -LAMIS). The technique combines femtosecond (fs) laser filamentation and ablation-based molecular isotopic spectroscopy, thereby enabling isotopic analysis of samples at a distance, in ambient air and at ambient pressure conditions. Isotopic analysis of zirconium (Zr) samples by F 2 -LAMIS is demonstrated, and the molecular and atomic emission intensity, and properties of the filament-induced plasma generated at different filament propagation distances were investigated. Spectral fitting of F 2 -LAMIS spectra enabled semi-quantitative isotopic analysis without the use of calibration standards, which was independent of the filament propagation distance for the studied range. As a result, this technology provides new capabilities for direct isotopic ratio measurements at remote distances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser ablation of polymers: a review

Laser ablation (LA), which employs a pulsed laser to remove materials from a substrate for generating micro-/nanostructures, has tremendous applications in the fabrication of metals, ceramics, glasses and polymers. It has become a noteworthy approach for achieving various functional structures in engineering, chemistry, biology, medicine and other fields. Polymers are one such class of materials; they can be melted and vaporized at high temperature during the ablation process. A number of polymers have been researched as candidate substrates in LA, and many different structures and patterns have been realized by this method. The current states of research and progress are reviewed from basic concepts to optimal parameters, polymer types and applications. Additionally, the significance of this paper is to provide a basis for follow-up research that leads to the development of superior materials and high-quality production through LA. In this review, we first introduce the basic concept of LA, including mechanism, laser types (millisecond, microsecond, nanosecond, picosecond and femtosecond) and influential parameters (wavelength, repetition rate, fluence and pulse duration). Then, we focus on several commonly used polymer materials and compare them in detail, including the effects of polymer properties, laser parameters and feature designs. Finally, we summarize the applications of various structures fabricated by LA in a variety of areas along with a perspective of the challenges in this research area. Overall, a thorough review of LA of several polymers is presented, which could pave the way for characterization of future novel materials.

36 MATERIALS SCIENCE↗

The effect of tumor size and location on efficacy and safety of US- and CT- guided percutaneous microwave ablation in renal cell carcinomas

Purpose: To evaluate the effect of size and central location of the tumor on safety and efficacy of percutaneous CEUS- and CT-guided MWA in biopsy-proven renal cell carcinomas (RCCs). Materials and methods: In this IRB-approved retrospective study, 69 biopsy-proven renal tumors in 56 patients, who underwent MWA in our institution from January 2013 to March 2017, were evaluated. Data collection included demographics, tumor characteristics, procedural protocols, and follow-up visits within 6 months post procedure. Primary outcomes were assessed by technical success (TS), local tumor progression (LTP), and complications. The Kaplan–Meier analysis was used for survival rate. Results: Overall technical success was achieved for all 69 lesions (92.8% primary TS, 100% overall). Median nephrometry score was 8 (4–11) and median tumor size was 2.5 cm (0.8–7). Five lesions which required second ablation had significantly higher median tumor size 4 cm (P = 0.039) with the same nephrometry score. Renal function remained stable with no significant change in eGFR before or after ablation. The LTP rate was 5.8%. The most recurrent tumors were clear cell (50%) followed by papillary tumors (25%). The complication rate was 5.8% with minor complications (hematoma and pain) and no major issues. There was no significant association between nephrometry score and technical success, recurrence, or complication rates. Overall and tumor-specific survival rates were 96.7% and 100% at 11.9 months. Conclusions: Image-guided MWA appears to be a safe and effective treatment regardless of nephrometry score and tumor location with high technical success, low recurrence, and complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcome after Radiofrequency Ablation of Sarcoma Lung Metastases

Purpose: Resection is the mainstay of management in patients with sarcoma lung metastases, but there is a limit to how many resections can be performed. Some patients with inoperable disease have small-volume lung metastases that are amenable to thermal ablation. We report our results after radiofrequency ablation (RFA). Methods: This is a retrospective study of patients treated from 2007 to 2012 in whom the intention was to treat all sites of disease and who had a minimum CT follow-up of 4 months. Treatment was performed under general anesthesia/conscious sedation using cool-tip RFA. Follow-up CT scans were analyzed for local control. Primary tumor type, location, grade, disease-free interval, prior resection/chemotherapy, number and size of lung tumors, uni- or bilateral disease, complications, and overall and progression-free survival were recorded. Results: Twenty-two patients [15 women; median age 48 (range 10–78) years] with 55 lung metastases were treated in 30 sessions. Mean and median tumor size and initial number were 0.9 cm and 0.7 (range 0.5–2) cm, and 2.5 and 1 (1–7) respectively. Median CT and clinical follow-up were 12 (4–54) and 20 (8–63) months, respectively. Primary local control rate was 52 of 55 (95 %). There were 2 of 30 (6.6 %) Common Terminology Criteria grade 3 complications with no long-term sequelae. Mean (median not reached) and 2- and 3-year overall survival were 51 months, and 94 and 85 %. Median and 1- and 2-year progression-free survival were 12 months, and 53 and 23 %. Prior disease-free interval was the only significant factor to affect overall survival. Conclusion: RFA is a safe and effective treatment for patients with small-volume sarcoma metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗