Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Features of multilayer mirror application for focusing and collimating X-rays from inverse Compton scattering sources

We have analysed the use of X-ray interference multilayer mirrors as the elements of a focusing scheme for a compact source based on inverse Compton scattering. An algorithm is proposed for selecting mirror parameters, which takes into account the properties of the radiation source. The dependence of wavelength on the viewing angle and the energy line broadening for a fixed viewing angle are found to be the main limitations in the use of multilayer mirrors. Efficient radiation collection calls for the application of broadband mirrors. It is shown that the efficiency of multilayer mirrors in a Kirkpatrick – Baez X-ray focusing setup exceeds that of total external reflection mirrors by an order of magnitude, and that stack multilayer mirrors offer a small advantage over the periodic ones. The overall efficiency of source radiation collection in the photon energy range ΔE = 10 – 12 keV amounts to 12 % for the two-mirror Kirkpatrick – Baez setup. For a spectral region with a bandwidth ΔE/E = 3 %, the efficiency ranges up to 69 %. (paper)

07 ISOTOPE AND RADIATION SOURCES↗

Imaging broadband soft X-ray transmission-grating spectrograph for a wavelength range λ > 111 Å

A family of aperiodic Mo/Be multilayer mirrors was designed for maximum uniform reflectivity in the ranges 111 – 138, 111 – 150, 111 – 200 and 111 – 222 Å at normal radiation incidence. The simulations took into account the existence of Mo-on-Be and Be-on-Mo transition layers. It was shown that the reflectivity may be as high as 10% in an octave wavelength range of 111 – 222 Å. We demonstrate the operation of an imaging transmission-grating spectrograph with a broadband Mo/Be multilayer mirror with a uniform reflectivity in the wavelength range 111 – 138 Å synthesised at the Institute for the Physics of Microstructures, RAS. The spectrograph was used to record the line spectra of multiply charged fluorine and magnesium ions from a laser-produced plasma. The role of the grating support structure in the formation of spectral source images is discussed. The spatial resolution of 50 μm is demonstrated. (laser applications and other topics in quantum electronics)

36 MATERIALS SCIENCE↗

Primary radiation damage in bone evolves via collagen destruction by photoelectrons and secondary emission self-absorption

X-rays are invaluable for imaging and sterilization of bones, yet the resulting ionization and primary radiation damage mechanisms are poorly understood. Here we monitor in-situ collagen backbone degradation in dry bones using second-harmonic-generation and X-ray diffraction. Collagen breaks down by cascades of photon-electron excitations, enhanced by the presence of mineral nanoparticles. We observe protein disintegration with increasing exposure, detected as residual strain relaxation in pre-stressed apatite nanocrystals. Damage rapidly grows from the onset of irradiation, suggesting that there is no minimal ‘safe’ dose that bone collagen can sustain. Ionization of calcium and phosphorous in the nanocrystals yields fluorescence and high energy electrons giving rise to structural damage that spreads beyond regions directly illuminated by the incident radiation. Our findings highlight photoelectrons as major agents of damage to bone collagen with implications to all situations where bones are irradiated by hard X-rays and in particular for small-beam mineralized collagen fiber investigations.

36 MATERIALS SCIENCE↗

Active Q-Switched X-Ray Regenerative Amplifier Free-Electron Laser

Despite tremendous progress in x-ray free-electron laser (FEL) science over the last decade, future applications still demand fully coherent, stable x-rays that have not been demonstrated in existing X-ray FEL facilities. Here in this Letter, we describe an active Q-switched x-ray regenerative amplifier FEL scheme to produce fully coherent, high-brightness, hard x rays at a high-repetition rate. By using simple electron-beam phase space manipulation, we show this scheme is flexible in controlling the x-ray cavity quality factor Q and hence the output radiation. We report both theoretical and numerical studies on this scheme with a wide range of accelerator, x-ray cavity, and undulator parameters.

47 OTHER INSTRUMENTATION↗

Multimodal, Multidimensional, and Multiscale X-ray Imaging at the National Synchrotron Light Source II

Over the last couple of decades, the synchrotron radiation research community has witnessed tremendous advancement in the field of x-ray imaging and microscopy. Continuing enhancement of the light sources’ brightness, advances in x-ray focusing optics, incorporation of precision instruments, and development of innovative imaging techniques are some of the leading contributors for the rapid progress. New imaging and microscopy beamlines, such as the ones at the National Synchrotron Light Source II (NSLS-II), a Department of Energy (DOE) Office of Science user facility located at DOE’s Brookhaven National Laboratory, are capable of performing more sophisticated and complicated measurements than ever before, either on their own or used together as a suite of tools. These sophisticated and complex measurements exhibit attributes for multimodal, multidimensional, and multiscale imaging. Recent popularity of these methods is strongly driven by the current trends in materials characterizations, where researchers desire to map out hierarchical materials structure over a large range of length scales, to understand structure-property correlation, to quantify materials structures in 3D, and/or to perform operando or in situ experiments. It is important to emphasize that “materials” under investigation are not only synthesized materials but also the natural materials. In this article, we describe multimodal, multidimensional and multiscale x-ray imaging capabilities of the NSLS-II beamlines and how these methods are used to tackle complex scientific problems.

47 OTHER INSTRUMENTATION↗

Analysis of Polarimetry Data with Angular Uncertainties

For a track based polarimeter, such as the Imaging X-ray Polarimetry Explorer (IXPE), the sensitivity to polarization depends on the modulation factor, which is a strong function of energy. In previous work, a likelihood method was developed that would account for this variation in order to estimate the minimum detectable polarization (MDP). That method essentially required that the position angles of individual events should be known precisely. In a separate work, however, it was shown that using a machine-learning method for measuring event tracks can generate track angle uncertainties, which can be used in the analysis. Here, the maximum likelihood method is used as a basis for revising the estimate of the MDP in a general way that can include uncertainties in event track position angles. The resultant MDP depends solely upon the distribution of track angle uncertainties present in the input data. Due to the physics of the IXPE detectors, it is possible to derive a simple relationship between these angular uncertainties and the energy-dependent modulation function as a step in the process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interior soft x-ray tomography with sparse global sampling

To investigate the feasibility of interior imaging reconstruction in soft X-ray tomography for higher-resolution cellular imaging, including whole-cell imaging, we develop an alignment and reconstruction algorithm that combines a small number of sparse whole-cell images with a high-resolution local interior scan. Based on numerical simulations, we demonstrate that combined reconstructions mitigate the depth-of-field limitation in high-resolution scans, enable radiation dose optimization, and yield quantitative X-ray absorption values with sparse sampling. We further validate our numerical approach using experimental data from two different cell types and show that the combined reconstruction reliably provides high spatial resolution within an interior region of interest of a whole cell. The resulting sparse reconstruction framework offers robust, faithful visualization of cellular organelles in soft X-ray tomography. This mesoscale imaging strategy allows one to ‘scout’ and zoom into selected subcellular volumes of interest, enabling increased spatial resolution without sacrificing larger-volume imaging and providing information on the relative positions of all organelles within a cell.

3D imaging↗

Quantifying the Solar Energy Resource for Puerto Rico

After Hurricane Maria, multiple U.S. Department of Energy laboratories studied the state of the electric grid in Puerto Rico and analyzed grid resilience and grid integration of renewable energy. As part of the work done at the National Renewable Energy Laboratory, researchers created new solar resource data, conducted a technical potential and supply curve analysis, and studied the interannual variability of the solar resource. A new methodology was developed to downscale solar resource data from the National Solar Radiation Data Base (NSRDB) from a 4-km x 4-km spatial and 30-minute temporal resolution to a 2 km x 2 km and 5-minute resolution. This methodology primarily used simple physical principles to develop high-resolution cloud properties which were then used to compute solar radiation. The high-resolution datasets were validated against ground measurements and the error metrics were found to be similar to the original lower resolution dataset. Using 20 years of downscaled data from the NSRDB multi-year capacity factors for photovoltaics (PV) were developed for both single-axis tracking and fixed latitude-tilt configurations. Use of the multi-year data provides the ability to understand variability in capacity factors due to variability in weather over a long period of time. For Puerto Rico the coastal regions were found to have significant higher capacity factors than inland. Using land-use and terrain information a technical potential analysis was conducted for Puerto Rico. This analysis restricted single PV plant development to a maximum of 100 MW nameplate capacity. The nameplate capacity for each municipality were then determined. Based on our assumptions, 56 of the 78 total municipalities of Puerto Rico contain some level of solar capacity. Most of the interior municipalities did not have any capacity because of the geographic exclusions used in this study. The lowest capacity for a PV plant observed in a municipality was 10 MW. The maximum capacity within a county was 2,000 MW. Further a supply curve analysis was conducted by taking the results of the technical potential and quantifying system and transmission costs. The levelized cost of energy (LCOE) was calculated for each theoretical PV plant site, and the levelized cost of transmission was added to the LCOE to produce a total cost estimate for each site. The results of the supply curve analysis allow for a relative comparison of the cost for integrating new PV capacity into the grid. This analysis indicates that cheaper total LCOE sites tend to be larger in capacity. The total capacity in this study was found to be far beyond the maximum peak load for the island. However, this study does not consider the economic and market potential for development. The cumulative capacity presented in this study assumes that the best locations are developed first and ignores the complex decision paths for new power plant development. Therefore, this analysis can only be treated as illustrative. Finally this study investigates the impact of inter-annual variability of resource using a variety of metrices including probability of exceedance and variation in capacity factor and LCOE. This study demonstrates that the capacity factor or LCOE could vary by over 10% year to year. This clearly indicates the risks involved in using any particular year of data and clearly points to the use of multi-year data to reduce some of the risks related to variability in weather.

14 SOLAR ENERGY↗

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.

3D Printing↗

Identification and Quantification of Beta-Emitters in Waste Packages by Segmented Gamma-Scanning - 20114

A commonly applied method for the non-destructive characterization of the radioactive inventory of waste packages (e.g. 200-l drums) is segmented gamma-scanning. The gamma-emitting inventory is identified via their characteristic lines in the measured spectra. The corresponding net peak areas allow for quantification applying appropriate models. The identification and quantification of beta-emitters present in the waste package require further evaluation. While some of them emit gamma-rays, too, which can be used for identification and quantification, pure beta-emitters contribute to the gamma-spectra only by their Bremsstrahlung-spectra. {sup 32}P, {sup 90}Sr and {sup 90}Y are typical representatives of these isotopes. A method is developed for identification and quantification of these pure beta-emitters in radioactive waste packages. Origin of the procedure is the evaluation of the measured gamma-spectrum. After the identification of all lines present in the spectrum (characteristic gamma-lines, single- and double-escape-lines, X-ray-lines, annihilation peak etc.) this information is used together with calibration data of the detection system and further a-priori information like matrix composition, cross-section data from databases etc. to simulate the spectra without the Bremsstrahlung-components by an appropriate method. This may be Monte Carlo simulations or, like in our case, a computer code taking into account mathematical descriptions of the physical effects like photo effect, (multiple) Compton scattering, backscattering etc. and the attenuation effects of the waste matrix. In any case, the resulting spectrum must simulate the real spectrum without its Bremsstrahlung-component as good as possible. Subtracting the simulated from the measured spectrum then results in the Bremsstrahlung-components caused by the beta-emitters. Prior to evaluation, a set of Bremsstrahlung-spectra is calculated and stored for different beta-emitters in different matrices using the Bethe-Heitler equation. This data set can be extended for new conditions, if necessary, and is allocated in a data base for future application. Applying a non-linear optimization using the generalized reduced gradient method for comparing the calculated with the derived Bremsstrahlung-spectra results in the identification of the beta-emitter and a factor, which is proportional to its activity. The proportionality is determined by previous calibration measurements. The application of the method is demonstrated by measurements on a 200-l mock-up drum and a real waste package. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Disorder-induced time effect in the antiferromagnetic domain state of Fe 1+ y Te

Herein we report on temperature-dependent soft X-ray absorption spectroscopy (XAS) measurements utilizing linearly polarized synchrotron radiation to probe magnetic phase transitions in iron-rich Fe 1+y Te (y ≈ 0.12). X-ray magnetic linear dichroism (XMLD) signals, which sense magnetic ordering processes at surfaces, start to increase monotonically below the Néel temperature T N = 57 K. This increase is due to a progressive bicollinear antiferromagnetic (AFM) alignment of Fe spins of the monoclinic Fe 1+y Te parent phase. This AFM alignment was achieved by a [1 0 0]-oriented biasing field favoring a single-domain state during cooling across T N . Our specific heat and magnetization measurements confirm the bulk character of this AFM phase transition. On longer time scales, however, we observe that the field-biased AFM state is highly unstable even at the lowest temperature of T = 3 K. After switching off the biasing field, the XMLD signal decays exponentially with a time constant τ = 1506 s. The initial XMLD signal is restored only upon repeating a cycle consisting of heating and field-cooling through T N . We explain the time effect by a gradual formation of a multi-domain state with 90° rotated AFM domains, promoted by structural disorder, facilitating the motion of twin-domains. Significant disorder in our Fe 1+y Te sample is evident from our X-ray diffraction and specific heat data. The stability of magnetic phases in Fe-chalcogenides is an important material property, since the Fe(Te 1-x Se x ) phase diagram shows magnetism intimately connected with superconductivity.

36 MATERIALS SCIENCE↗

Guest Editorial

The design of X-ray optical systems is very different from that of conventional optical systems, whether it be for the peculiarities of synchrotron radiation or the grazing incidence operation of most X-ray optical components. Further, specific simulation tools are thus required to ensure that designs work as expected, and there is now a vibrant landscape of open-source, freely available software that can be used to that end, and explore new design concepts.

47 OTHER INSTRUMENTATION↗

Sensitive and robust thin film X-ray detector using 2D layered perovskite diodes

A radiation detector includes a p-i-n architecture including a p-type contact layer, an n-type contact layer, and an intrinsic layer between the p-type contact layer and the n-type contact layer. The intrinsic layer includes a thin film comprising a highly crystalline 2D layered perovskite material. The radiation detectors according to embodiments of the present disclosure generate high open circuit voltages, have good detecting photon density limits and high sensitivities, and can be self-powered.

Tsai, Hsinhan↗

First study of Hohlraum x-ray preheat asymmetry inside an ICF capsule

In indirect drive inertial confinement fusion (ICF), laser induced Hohlraum preheat radiation (so-called M-band, >1.8 keV) asymmetry will lead to asymmetric ablation front and ablator–fuel interface hydrodynamic instability growth in an imploding capsule. First experiments to infer the M-band asymmetries at the capsule were performed on the National Ignition Facility for high density carbon (HDC) ICF capsules in low density fill (0.3 mg/cc 4 He) Au Hohlraums by time resolved imaging of 2.3 keV fluorescence emission of a smaller Mo sphere placed inside the capsule. In this study, the measured Mo emission is pole hot (P 2 > 0) since M-band is generated mainly by the outer laser beams as their irradiance at the Hohlraum wall is 5× higher than for the inner beams. P 2 has a greater negative than positive swing vs time [Δ(P 2 /P 0 )/Δt ~ 0.2/ns], giving insight into laser heated Hohlraum dynamics. P 4 asymmetry is small at the sphere due to efficient geometric smoothing of Hohlraum asymmetries at large Hohlraum -to-capsule ratios. The M-band P 2 history is qualitatively reproduced by radiation hydrodynamic HYDRA simulations. The smaller P 2 than that calculated earlier suggests either less outer beam spot motion and/or preheat emission. At late times, the observed P 2 swing is larger and P 4 is more negative than simulated, which could be due to inner beams being stopped more in the outer beams wall plasma bubble than simulated. Asymmetry at the HDC capsule inner surface (“ice–ablator interface”) is also inferred from the Mo emission asymmetry by an analytic viewfactor model, accounting for the Mo/HDC radius difference and HDC capsule opacity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New Dimensions in the Theory of Excited States and X-ray Spectra (Final Report)

This Final Technical Report briefly summarizes the achievements during the lifetime of our DOE BES grant DE-FG02-97ER45623. The long-term goal of this project has been the development of quantitative theories of the interaction between radiation and matter, with a focus on x-ray spectroscopies. X-ray spectra have long been among the most important probes of atomic-scale structure and properties of matter, ranging from atoms and molecular systems to condensed matter and exotic states. These spectroscopies are widely used in investigations at the major DOE synchrotron x-ray facilities and related centers world-wide. In addition to fundamental theory, a major goal of our project has been the development of computational software that implements the theory for calculations of x-ray spectra of various materials throughout the periodic table. Due to the complex nature of x-ray spectra, quantitative theory is essential for its interpretation. The theory is challenging since it involves excited state electronic structure and many-body correlation effects that go beyond independent particle approximations like DFT or Hartree-Fock. Moreover, the experimental investigations typically involve a broad range of energy, time, and temperature scales, from the UV-Vis to hard x-ray energies of order 10 4 eV, and temperatures T from ambient up to the warm-dense-matter regime where the Fermi energy kBTF is of order a few eV, i.e., temperatures of order 105 Kelvin. This broad range of experimental conditions has fostered many novel theoretical approaches and computational techniques, many of which we have developed systematically over the duration of the grant. In contrast to the traditional wave-function approach of quantum theory and electronic structure methods, our theoretical approach is based on modern Green's function techniques. This approach is better suited for aperiodic structures, excited states, and broad spectral ranges, since it avoids the computational bottlenecks of sum-over-states approaches, as in the Fermi golden rule. This theoretical framework has been incorporated into efficient, user-friendly x-ray spectroscopy software which is now used routinely worldwide to simulate and analyze spectra. These theoretical tools provide an essential complement to synchrotron and next-generation light sources, which are used to investigate complex materials with ever increasing precision. Moreover, the synergism between theory, computation and experiment contributed by our research enhances scientific understanding and creates opportunities for innovations in materials and energy science and in many fields. As documented in this Report, this research grant has been remarkably successful in achieving these goals. In particular, this grant has supported the development of the x-ray spectroscopy software suite known as FEFF (named for an effective scattering amplitude f eff in the theory). The FEFF codes have become one of the premier tools for quantitative simulations of x-ray spectra as documented by many thousands of citations in the Web of Science and Google-Scholar.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Supplementing Gamma Sterilization with X-Ray and E-Beam Technologies: An International Industry and Academia Collaboration

Ionizing-technology–based industries are growing rapidly around the world. The expansion is driven mostly by the technology’s myriad applications, including polymer crosslinking, medical device sterilization, food pasteurization, and phytosanitary treatment. Ionization also is used in the manufacture of some healthcare products such as medical devices and biopharmaceuticals. Industrial sterilization methods render single-use products and manufacturing components safe and ready for their intended use. ISO11137-1 describes the validation and routine control of a sterilization process for medical devices and mentions the three types of radiation considered under this scope: gamma, X-ray, and electron beam (e-beam)

gamma sterilization, electron beam sterilization, ↗

Chemical crystallography by serial femtosecond X-ray diffraction

Abstract Inorganic–organic hybrid materials represent a large share of newly reported structures, owing to their simple synthetic routes and customizable properties 1 . This proliferation has led to a characterization bottleneck: many hybrid materials are obligate microcrystals with low symmetry and severe radiation sensitivity, interfering with the standard techniques of single-crystal X-ray diffraction 2,3 and electron microdiffraction 4–11 . Here we demonstrate small-molecule serial femtosecond X-ray crystallography (smSFX) for the determination of material crystal structures from microcrystals. We subjected microcrystalline suspensions to X-ray free-electron laser radiation 12,13 and obtained thousands of randomly oriented diffraction patterns. We determined unit cells by aggregating spot-finding results into high-resolution powder diffractograms. After indexing the sparse serial patterns by a graph theory approach 14 , the resulting datasets can be solved and refined using standard tools for single-crystal diffraction data 15–17 . We describe the ab initio structure solutions of mithrene (AgSePh) 18–20 , thiorene (AgSPh) and tethrene (AgTePh), of which the latter two were previously unknown structures. In thiorene, we identify a geometric change in the silver–silver bonding network that is linked to its divergent optoelectronic properties 20 . We demonstrate that smSFX can be applied as a general technique for structure determination of beam-sensitive microcrystalline materials at near-ambient temperature and pressure.

36 MATERIALS SCIENCE↗