Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Window”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Pushing the limits of the electrochemical window with pulse radiolysis in chloroform

Pulse radiolysis (PR) enables the full redox window of a solvent to be accessed, as it does not require electrodes or electrolyte which limit the potentials accessible in voltammetry measurements. PR in chloroform has the additional possibility to enable reaching highly positive potentials because of its large ionization potential (IP). We report PR experiments demonstrated the formation of the (deuterated) chloroform radical cation CDCl 3 + ˙, identifying it as the source of the broad absorption in the visible part of the spectrum. Results indicated that solutes with a redox potential up to +3.7 V vs. Fc/Fc + can be oxidized by CDCl 3 + ˙, which is far beyond what is possible with electrochemical techniques. Oxidation is not efficient because of rapid geminate recombination with chloride counterions, but also due to rapid decomposition of CDCl 3 + ˙ which limits the yield of otherwise longer-lived free ions. The rapid, 6 ± 3 ns, decomposition, confirmed by two independent experiments, means that a solute must be present at a concentration >100 mM to capture >90% of the free holes formed. Addition of ethene removes the broad, overlapping absorptions from ubiquitous (chlorine atom, solute) complexes created by PR in halogenated solvents enabling clear observation of solute cations. The results also unravel the complex radiation chemistry of chloroform including the large reported value G (–CHCl 3 ) = 12 molecules/100 eV for the decomposition of chloroform molecules.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved model for window breakdown at low pressure

An improved global model is proposed to analyze high power microwave dielectric window breakdown at low pressure. The effect of ionization on the average momentum and energy of electrons is taken into account and a Maxwellian electron energy distribution function is adopted. The plasma energy flow and density loss to dielectric, and partially secondary electrons returning plasma to compensate the density loss, have been analytically considered. Space charge potential drop and the generalized Bohm criterion are deduced analytically. After considering the energy and density loss as well as the secondary electron compensation, the breakdown time by using numerical calculation under low pressure gets shorter compared with that under no wall loss condition. In other words, the dielectric surface breakdown time is lower than plasma volume breakdown time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-brightness water-window electron-impact liquid-jet microfocus source

We demonstrate stable high-brightness operation of an electron-impact water-jet-anode soft x-ray source. A 30 kV, 7.8 W electron beam is focused onto a 20 mum diameter jet resulting in water-window oxygen line emission at 525 eV/2.36 nm with a brightness of 3.0x10{sup 9} ph/(sxmum{sup 2}xsrxline). Monte Carlo-based modeling shows good quantitative agreement with the experiments. The source has potential to increase the x-ray power and brightness by another 1-2 orders of magnitude and fluid-dynamical jet instabilities is determined to be the most important limiting factor. The source properties make it an attractive alternative for table-top x-ray microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of recent theories and experiments for improving high-power microwave window breakdown thresholds

Dielectric window breakdown is a serious challenge in high-power microwave (HPM) transmission and radiation. Breakdown at the vacuum/dielectric interface is triggered by multipactor and finally realized by plasma avalanche in the ambient desorbed or evaporated gas layer above the dielectric. Methods of improving breakdown thresholds are key challenges in HPM systems. First, the main theoretical and experimental progress is reviewed. Next, the mechanisms of multipactor suppression for periodic rectangular and triangular surface profiles by dynamic analysis and particle-in-cell simulations are surveyed. Improved HPM breakdown thresholds are demonstrated by proof-of-principle and multigigawatt experiments. The current theories and experiments of using dc magnetic field to resonantly accelerate electrons to suppress multipactor are also synthesized. These methods of periodic profiles and magnetic field may solve the key issues of HPM vacuum dielectric breakdown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of surface produced secondary electrons on the sheath structure induced by high-power microwave window breakdown

Dielectric window breakdown, whose mechanism is not thoroughly understood, is a major factor of limiting the transmission and radiation of high-power microwave on the order of 1 GW. In this paper, a one-dimensional fluid-like sheath model is developed to investigate the sheath structures formed at different gas pressures. The dominant processes during the surface flashover are isolated by this model. In vacuum, electron multipactor is self-sustained by secondary electron emission, a positive space-charge potential is formed on the dielectric surface. With increasing gas pressure, electron-neutral ionization prevails against secondary electron emission. The multipactor effect is suppressed by the shielding of plasma electrons. This leads to the sheath potential changing gradually from a positive space-charge potential to a negative space-charge potential. For argon gas pressure lower than 14 Torr, the sheath is space charge limited. A potential minimum could be formed in front of the dielectric which traps secondary electrons emitted from the wall. With the higher argon gas pressure, the number density of ions becomes comparable to that of electrons, all surface produced electrons are accelerated toward the presheath region. Therefore, the normal sheath is formed and the resulting surface flashover on the dielectric surface becomes rf-driven volumetric breakdown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dosimetric comparison of volumetric modulated Arc therapy, step-and-shoot, and sliding window IMRT for prostate cancer

This study aims to evaluate treatment plans generated by Step-and-Shoot (SS), Sliding Window (SW) and Volumetric Modulated Arc Therapy (VMAT) in order to assess the differences in dose volume histograms of planning target volume (PTV) and organs at risk (OAR), conformity indices, radiobiological evaluations, and plan quality for prostate cancer cases. Six prostate cancer patients treated in our center were selected for this retrospective study. Treatment plans were generated with Eclipse version 8.9 using 10 MV photon beams. For VMAT, Varian Rapid Arc with 1 or 2 arcs, and for SS and SW IMRT, 7-9 fields were used. Each plan had three PTVs with prescription doses of 81, 59.4, and 45 Gy to prostate, to prostate and lymph nodes, and to pelvis, respectively. Doses to PTV and OAR and the conformal indices (COIN) were compared among three techniques. The equivalent uniform dose (EUD), tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated and compared. The mean doses to the PTV prostate on average were 83 Gy and the percent differences of mean dose among all techniques were below 0.28. For bladder and rectum, the percent differences of mean dose among all techniques were below 2.2. The COIN did not favour any particular delivery method over the other. The TCP was higher with SS and SW for four patients and higher with VMAT for two patients. The NTCP for the rectum was the lowest with VMAT in five out of the six patients. The results show similar target coverage in general.

61 RADIATION PROTECTION AND DOSIMETRY↗

Infrared characteristics of VO{sub 2} thin films for smart window and laser protection applications

Vanadium dioxide (VO{sub 2}) films with a low semiconductor-to-metal transition temperature of 45 Degree-Sign C were fabricated through direct current magnetron sputtering followed by a post-annealing. Atomic force microscopy measurements show that the VO{sub 2} grain size is about one hundred of nanometers. Infrared (IR) characteristic is well investigated by applying a He-Ne laser power intensity measurement, and the result reveals that the VO{sub 2} film exhibits excellent IR switching property. Furthermore, solar smart window and laser protection experiments demonstrate that the obtained VO{sub 2} thin film is a promising material for the application in related fields.

36 MATERIALS SCIENCE↗

Core and Valence Excitations in Resonant X-ray Spectroscopy using Restricted Excitation Window Time-dependent Density Functional Theory

We report simulations of X-ray absorption near edge structure (XANES), resonant inelastic X-ray scattering (RIXS) and 1D stimulated X-ray Raman spectroscopy (SXRS) signals of cysteine at the oxygen, nitrogen and sulfur K and L2,3 edges. The simulated XANES signals from the restricted window time-dependent density functional theory (REW-TDDFT) and the static exchange (STEX) method are compared with experiments, showing that REW-TDDFT is more accurate and computationally less expensive than STEX. Simulated RIXS and 1D SXRS signals from REW-TDDFT give some insights on the correlation of different excitations in the molecule.

Environmental Molecular Sciences Laboratory↗

'Water window' sources: Selection based on the interplay of spectral properties and multilayer reflection bandwidth

Development of laser-produced plasma 'water window' sources poses a major challenge in x-ray research and most effort has focused on line sources for use with zone plate optics. Here, a comparison of carbon and nitrogen line emission with that from both 3d - 4f and 4d - 4f unresolved transition arrays shows that, at power densities available from 'table-top' solid-state lasers, 3d - 4f emission from zirconium plasmas is most intense, and calculations show that in an imaging system based on multilayer mirrors, for reflectance bandwidths >1% has superior performance than either line or broader-band sources. For bandwidths <1%, line sources are preferable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rarefaction windows in a high-power impulse magnetron sputtering plasma

The velocity distribution function of the sputtered particles in the direction parallel to the planar magnetron cathode is studied by spatially- and time-resolved laser-induced fluorescence spectroscopy in a short-duration (20 μs) high-power impulse magnetron sputtering discharge. The experimental evidence for the neutral and ionized sputtered particles to have a constant (saturated) velocity at the end of the plasma on-time is demonstrated. The velocity component parallel to the target surface reaches the values of about 5 km/s for Ti atoms and ions, which is higher that the values typically measured in the direct current sputtering discharges before. The results point out on the presence of a strong gas rarefaction significantly reducing the sputtered particles energy dissipation during a certain time interval at the end of the plasma pulse, referred to as “rarefaction window” in this work. The obtained results agree with and essentially clarify the dynamics of HiPIMS discharge studied during the plasma off-time previously in the work: N. Britun, Appl. Phys. Lett. 99, 131504 (2011)

36 MATERIALS SCIENCE↗

Numerical study of the effect of normalised window size, sampling frequency, and noise level on short time Fourier transform analysis

Photonic Doppler velocimetry, also known as heterodyne velocimetry, is a widely used optical technique that requires the analysis of frequency modulated signals. This paper describes an investigation into the errors of short time Fourier transform analysis. The number of variables requiring investigation was reduced by means of an equivalence principle. Error predictions, as the number of cycles, samples per cycle, noise level, and window type were varied, are presented. The results were found to be in good agreement with analytical models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An ultra-thin diamond membrane as a transmission particle detector and vacuum window for external microbeams

Several applications of external microbeam techniques demand a very accurate and controlled dose delivery. To satisfy these requirements when post-sample ion detection is not feasible, we constructed a transmission single-ion detector based on an ultra-thin diamond membrane. The negligible intrinsic noise provides an excellent signal-to-noise ratio and enables a hit-detection efficiency of close to 100%, even for energetic protons, while the small thickness of the membrane limits beam spreading. Moreover, because of the superb mechanical stiffness of diamond, this membrane can simultaneously serve as a vacuum window and allow the extraction of an ion microbeam into the atmosphere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stability enhancement of an electrically tunable colloidal photonic crystal using modified electrodes with a large electrochemical potential window

The color tuning behavior and switching stability of an electrically tunable colloidal photonic crystal system were studied with particular focus on the electrochemical aspects. Photonic color tuning of the colloidal arrays composed of monodisperse particles dispersed in water was achieved using external electric field through lattice constant manipulation. However, the number of effective color tuning cycle was limited due to generation of unwanted ions by electrolysis of the water medium during electrical switching. By introducing larger electrochemical potential window electrodes, such as conductive diamond-like carbon or boron-doped diamond, the switching stability was appreciably enhanced through reducing the number of ions generated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Symmetrical windowing for quantum states in quasi-classical trajectory simulations: Application to electron transfer

It has recently been shown [S. J. Cotton and W. H. Miller, J. Chem. Phys. 139, 234112 (2013)] that a symmetrical windowing quasi-classical (SQC) approach [S. J. Cotton and W. H. Miller, J. Phys. Chem. A 117, 7190 (2013)] applied to the Meyer-Miller model [H.-D. Meyer and W. H. Miller, J. Chem. Phys. 70, 3214 (1979)] for the electronic degrees of freedom in electronically non-adiabatic dynamics is capable of quantitatively reproducing quantum mechanical results for a variety of test applications, including cases where “quantum” coherence effects are significant. Here we apply this same SQC methodology, within a flux-side correlation function framework, to calculate thermal rate constants corresponding to several proposed models of electron transfer processes [P. Huo, T. F. Miller III, and D. F. Coker, J. Chem. Phys. 139, 151103 (2013); A. R. Menzeleev, N. Ananth, and T. F. Miller III, J. Chem. Phys. 135, 074106 (2011)]. Good quantitative agreement with Marcus Theory is obtained over several orders of magnitude variation in non-adiabatic coupling. Moreover, the “inverted regime” in thermal rate constants (with increasing bias) known from Marcus Theory is also reproduced with good accuracy by this very simple classical approach. The SQC treatment is also applied to a recent model of photoinduced proton coupled electron transfer [C. Venkataraman, A. V. Soudackov, and S. Hammes-Schiffer, J. Chem. Phys. 131, 154502 (2009)] and population decay of the photoexcited donor state is found to be in reasonable agreement with results calculated via reduced density matrix theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory-size three-dimensional x-ray microscope with Wolter type I mirror optics and an electron-impact water window x-ray source

We constructed a laboratory-size three-dimensional water window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques, and observed bio-medical samples to evaluate its applicability to life science research fields. It consists of a condenser and an objective grazing incidence Wolter type I mirror, an electron-impact type oxygen Kα x-ray source, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit of around 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-μm scale three-dimensional fine structures were resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digitized detection of gamma-ray signals concentrated in narrow time windows for transient positron annihilation lifetime spectroscopy

A pulsed slow-positron beam generated by an electron linear accelerator was directly used for positron annihilation lifetime spectroscopy without any positron storage devices. A waveform digitizer was introduced to simultaneously capture multiple gamma-ray signals originating from positron annihilation events during a single accelerator pulse. The positron pulse was chopped and bunched with the chopper signals also sent to the waveform digitizer. Time differences between the annihilation gamma-ray and chopper peaks were calculated and accumulated as lifetime spectra in a computer. The developed technique indicated that positron annihilation lifetime spectroscopy can be performed in a 20 μs time window at a pulse repetition rate synchronous with the linear accelerator. Lifetime spectra of a Kapton sheet and a thermally grown SiO{sub 2} layer on Si were successfully measured. Synchronization of positron lifetime measurements with pulsed ion irradiation was demonstrated by this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of periodic wavy profile on suppressing window multipactor under arbitrary electromagnetic mode

The three-dimensional periodic ripple profile with each unit of rotational symmetric surface is proposed to suppress multipactor for arbitrary electromagnetic mode with any polarization. The field distribution and multipactor electron dynamics on the wavy surface are studied to illustrate the multipactor inhibition mechanism. High power microwave experiment was conducted to demonstrate the effect of wavy surface on significantly improving the window power capacity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Graphene/semiconductor silicon modified BiFeO{sub 3}/indium tin oxide ferroelectric photovoltaic device for transparent self-powered windows

We report photovoltaic response of highly transparent graphene/BiFe{sub 0.95}Si{sub 0.05}O{sub 3} (BFSiO)/ITO/glass derived from bottom-up spin coating technique. The device exhibits short-circuit-current (I{sub SC} 0.75 mA) with 1000 fold upsurge and open-circuit-voltage (V{sub OC} ∼ 0.45 V) under standard AM 1.5 illumination through graphene. In combination, I{sub SC} of 0.63 mA and V{sub OC} of 0.35 V for same illumination through ITO, reveals the prospects of harvesting indoor light. Also, crystallographic structure, red shift in band gap, leakage behavior, and ferroelectric characteristics of BFSiO thin films are reported. Reproducible transient response of I{sub SC} and V{sub OC} with quick switching (<100 ms) for 20 consecutive cycles and stability (95%) over test period of 16 weeks signifies high endurance and retentivity, promising for building integrated self-powered windows.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗