Water electrolysis system refurbishment and testing

The electrolytic oxygen generator for the back-up water electrolysis system in a 90-day manned test was refurbished, improved and subjected to a 182-day bench test. The performance of the system during the test demonstrated the soundness of the basic electrolysis concept, the high development status of the automatic controls which allowed completely hands-off operation, and the capability for orbital operation. Some design improvements are indicated.

Greenough, B. M.↗

Manufacturing Competitiveness Analysis for PEM and Alkaline Water Electrolysis Systems

To examine the factors that drive regional competitiveness in the manufacturing of water electrolysis systems, bottom-up manufacturing cost analysis was developed for PEM and alkaline stacks and systems. Results show that alkaline electrolyzer stack tends to have a lower cost in ($/kW) basis, but this comes with lower power density and lower hydrogen production capacities for alkaline electrolyzers making PEM more economic at the long run.

30 DIRECT ENERGY CONVERSION↗

Model validation using CFD-grade experimental database for NGNP Reactor Cavity Cooling Systems with water and air

This project has been focused on the experimental and numerical investigations of the water-cooled and air-cooled Reactor Cavity Cooling System (RCCS) designs. At this aim, we have leveraged an existing experimental facility at the University of Wisconsin-Madison (UW), and we have designed and built a separate effect test facility at the University of Michigan. The experimental facility at UW has underwent several upgrades, including the installation of advanced instrumentation (i.e. wire-mesh sensors) built at the University of Michigan. These provides highresolution time-resolved measurements of the void-fraction distribution in the risers of the water-cooled RCCS facility. A phenomenological model has been developed to assess the water cooled RCCS system stability and determine the root cause behind the oscillatory behavior that occurs under normal two-phase operation. Testing under various perturbations to the water-cooled RCCS facility have resulted in changes in the stability of the integral system. In particular, the effects on stability of inlet orifices, water tank volume have and system pressure been investigated. MELCOR was used as a predictive tool when performing inlet orificing tests and was able to capture the Density Wave Oscillations (DWOs) that occurred upon reaching saturation in the risers. The experimental and numerical results have then been used to provide RCCS design recommendations. The experimental facility built at the University of Michigan was aimed at the investigation of mixing in the upper plenum of the air-cooled RCCS design. The facility has been equipped with state-of-theart high-resolution instrumentation to achieve so-called CFD grade experiments, that can be used for the validation of Computational Fluid Dynanmics (CFD) models, both RANS (Reynold-Averaged) and LES (Large Eddy Simulations). The effect of risers penetration in the upper plenum has been investigated as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of pressurized water cleaning systems for hardware refurbishment

Historically, refurbishment processes for RSRM motor cases and components have employed environmentally harmful materials. Specifically, vapor degreasing processes consume and emit large amounts of ozone depleting compounds. This program evaluates the use of pressurized water cleaning systems as a replacement for the vapor degreasing process. Tests have been conducted to determine if high pressure water washing, without any form of additive cleaner, is a viable candidate for replacing vapor degreasing processes. This paper discusses the findings thus far of Engineering Test Plan - 1168 (ETP-1168), 'Evaluation of Pressurized Water Cleaning Systems for Hardware Refurbishment.'

Dillard, Terry W.↗

Challenges with Operating a Water Recovery System (WRS) in the Microgravity Environment of the International Space Station (ISS)

The ISS WRS produces potable water from crew urine, crew latent, and Sabatier product water. This system has been operational on ISS since November 2008, producing over 30,000 L of water during that time. The WRS includes a Urine Processor Assembly (UPA) to produce a distillate from the crew urine. This distillate is combined with the crew latent and Sabatier product water and further processed by the Water Processor Assembly (WPA) to the potable water. The UPA and WPA use technologies commonly used on ISS for water purification, including filtration, distillation, adsorption, ion exchange, and catalytic oxidation. The primary challenge with the design and operation of the WRS has been with implementing these technologies in microgravity. The absence of gravity has created unique issues that impact the constituency of the waste streams, alter two-phase fluid dynamics, and increases the impact of particulates on system performance. NASA personnel continue to pursue upgrades to the existing design to improve reliability while also addressing their viability for missions beyond ISS.

Carter, Donald Layne↗

Thermosyphon Cooler Hybrid System for Water Savings in an Energy-Efficient HPC Data Center: Results from 24 Months and the Impact on Water Usage Effectiveness

In August 2016, the National Renewable Energy Laboratory (NREL) installed a thermosyphon hybrid cooling system to reduce water usage in its already extremely energy-efficient High-Performance Computing (HPC) Data Center. In its first year of use, the system saved 4,400 m3 (1.16 million gal) of water, and 7,950 m3 (2.10 million gal) during a 2-year period, cutting the use of water in the data center by about one-half. NREL's 930-m2 (10,000-ft2) HPC Data Center is often called the most energy-efficient data center in the world: it has achieved a trailing 12-month average power usage effectiveness of 1.034, and it features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. NREL considered the amount of water used by the cooling towers to be counter to the laboratory's sustainability mission, so a team of researchers from NREL, Sandia National Laboratories (Sandia), and Johnson Controls integrated the BlueStream thermosyphon cooler (TSC) - an advanced dry cooler that uses refrigerant in a passive cycle to dissipate heat - on the roof of NREL's Energy Systems Integration Facility, the building that houses the HPC Data Center. In combination with the existing cooling towers, the TSC forms an extremely water- and cost-efficient cooling system. In its first year of operation, on-site water usage effectiveness (WUE) was 0.70 L/kWh. In comparison, the WUE would be 1.27 L/kWh if NREL had continued using only heat-recovery and cooling towers. This on-site water savings was accomplished without negatively impacting the energy-efficient operation of the HPC Data Center. The TSC system technology has the potential for application in data centers around the world, and it is currently being implemented by Sandia. center by about one-half. NREL's 930-m2 (10,000-ft2) HPC Data Center is often called the most energy-efficient data center in the world: it has achieved a trailing 12-month average power usage effectiveness of 1.034, and it features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. NREL considered the amount of water used by the cooling towers to be counter to the laboratory's sustainability mission, so a team of researchers from NREL, Sandia National Laboratories (Sandia), and Johnson Controls integrated the BlueStream thermosyphon cooler (TSC) - an advanced dry cooler that uses refrigerant in a passive cycle to dissipate heat - on the roof of NREL's Energy Systems Integration Facility, the building that houses the HPC Data Center. In combination with the existing cooling towers, the TSC forms an extremely water- and cost-efficient cooling system. In its first year of operation, on-site water usage effectiveness (WUE) was 0.70 L/kWh. In comparison, the WUE would be 1.27 L/kWh if NREL had continued using only heat-recovery and cooling towers. This on-site water savings was accomplished without negatively impacting the energy-efficient operation of the HPC Data Center. The TSC system technology has the potential for application in data centers around the world, and it is currently being implemented by Sandia.

97 MATHEMATICS AND COMPUTING↗

Mediated electrosynthesis of silver nanoparticles in a two-phase water—isooctane system

Efficient electrosynthesis of silver nanoparticles (AgNPs) in bulk solution of a two-phase water—isooctane system is carried out by electrolysis in an undivided cell in the presence of methylviologen (MV{sup 2+}) used as a mediator. Silver nanoparticles are formed in the aqueous phase of the system as a result of the electroreduction of Ag{sup +} ions generated in situ by dissolving the Ag anode at potentials of the redox couple MV{sup 2+}/MV{sup ·+}. The obtained AgNPs are stabilized by an anionic surfactant, sodium dioctyl sulfosuccinate, and are distributed throughout both the aqueous and the organic phases. All the nanoparticles would transfer to the organic phase after the obtained solution was kept in the dark for 48 h. In addition to dissolution, the Ag anode undergoes dispersion during electrolysis, therefore the total current yield of the obtained AgNPs is 175%. According to electron microscopy, the formed AgNPs are polydisperse and their size ranges from 5 to 71 nm. A surface plasmon resonance of AgNPs in the solution obtained after electrolysis was observed in the region of 418–463 nm.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

OSU High Temperature Test Facility Design Technical Report, Revision 2

The HTTF is an integral test facility, which has been designed to model the behavior of interest for a MHTGR during the Depressurized Conduction Cooldown (DCC) event. It also has the potential to conduct limited explorations into the progression of the Pressurized Conduction Cooldown (PCC) event and phenomena during normal operations. The facility is scaled 1:4 by height and 1:64 by volume. A scaling report has been developed and provides further detail into the scaling analysis for the HTTF. The maximum core power for the facility is approximately 2.2MW. The core region will be of a modular design to allow for both the prismatic block core and the pebble bed core designs to be tested. However, only the prismatic block design is discussed in this report. The HTTF consists of the following systems: A primary system consisting of the reactor pressure vessel (RPV), the circulator, cross over ducts and primary piping. The core internals sit inside the RPV and provide support for the core and core heaters. The purpose of the primary system is to maintain the pressure boundary, remove heat from the core through convection, conduction and radiation, and provide heat to the core through a series of electrical heaters. A secondary system consisting of a steam generator, feed water system and main steam system. The purpose of the secondary system is to remove heat from the primary system during heat up, cool down and normal operations. A reactor cavity simulation system consisting of a cavity tank, gas conditioning system and a series of break valves. Note that the prototypical MHTGR sits inside of a cavity. In the event of a break the helium will blowdown into this cavity. At the HTTF, the cavity is modeled as a separate tank, the reactor cavity simulation tank (RCST) and is connected to the RPV through break valves—hot-leg, cold-leg, upper break, and lower break. A reactor cavity cooling system (RCCS) consisting of a series of water cooled panels and the water supply system for these panels. The HTTF RCCS is not a scaled prototypical RCCS system for the MHTGR. It is provided in the HTTF in order to set the boundary condition for radiation heat transfer from the RPV. Various auxiliary systems including the city water supply system, the electrical power supply and distribution system, the chilled water system and the instrument air system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or a combination of adsorption and ion exchange processes. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission without resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery Carlson↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or a combination of adsorption and ion exchange processes. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission without resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery L. Carlson↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or adsorption and ion exchange. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission with minimal resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery L. Carlson↗

Modeling Evolvable Water Recovery Systems for Short and Long-Duration Missions in Partial Gravity

Water recovery technologies on the International Space Station (ISS) are designed and optimized for microgravity environments, thus creating a need for innovative systems optimized for mission operations in the presence of gravity. Alternative water recovery technologies under research by the Life Support Systems division were compiled into a series of Partial Gravity Water Recovery System (PGWRS) architectures. Individual unit processes were modeled via fundamental physical-chemical process equations to simulate their method of treatment, including chemical or biological oxidation, flash evaporation, filtration, or adsorption and ion exchange. Dimension and sizing data were then utilized to scale each architecture. Modeling was completed on an assortment of architectures assuming three scenarios in which treatment methods could take advantage of partial gravity: a short-duration mission with a temporary surface habitat, a longer duration mission with a more permanent habitat, and a long duration mission with minimal resupply. Total system mass was estimated to quantitatively compare architectures within scenarios, but qualitative observations were also made regarding system robustness, flexibility, and capacity to meet more stringent demands. Technologies that traded most favorably between the scenarios were those that included a pre-oxidation stage to minimize mass loading to downstream absorption and ion exchange beds, exploited gravity in liquid-vapor separation processes, and reconstituted wastewater components into recyclable material streams.

Avery Carlson↗

Side-by-Side Testing of Water Heating Systems: Results from the 2013-2014 Evaluation

The Florida Solar Energy Center (FSEC) has completed a fourth year-long evaluation on residential hot water heating systems in a laboratory environment (east central Florida, hot-humid climate). This report contains a summary of research activities regarding the evaluation of two residential electric heat pump water heaters (HPWHs), a solar thermal system utilizing a polymer glazed absorber and a high efficiency natural gas system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microbiological methods for the water recovery systems test, revision 1.1

Current microbiological parameters specified to verify microbiological quality of Space Station Freedom water quality include the enumeration of total bacteria, anaerobes, aerobes, yeasts and molds, enteric bacteria, gram positives, gram negatives, and E. coli. In addition, other parameters have been identified as necessary to support the Water Recovery Test activities to be conducted at the NASA/MSFC later this year. These other parameters include aerotolerant eutrophic mesophiles, legionellae, and an additional method for heterotrophic bacteria. If inter-laboratory data are to be compared to evaluate quality, analytical methods must be eliminated as a variable. Therefore, each participating laboratory must utilize the same analytical methods and procedures. Without this standardization, data can be neither compared nor validated between laboratories. Multiple laboratory participation represents a conservative approach to insure quality and completeness of data. Invariably, sample loss will occur in transport and analyses. Natural variance is a reality on any test of this magnitude and is further enhanced because biological entities, capable of growth and death, are specific parameters of interest. The large variation due to the participation of human test subjects has been noted with previous testing. The resultant data might be dismissed as 'out of control' unless intra-laboratory control is included as part of the method or if participating laboratories are not available for verification. The purpose of this document is to provide standardized laboratory procedures for the enumeration of certain microorganisms in water and wastewater specific to the water recovery systems test. The document consists of ten separate cultural methods and one direct count procedure. It is not intended nor is it implied to be a complete microbiological methods manual.

Rhoads, Tim↗

The Implications of Global Change for the Co-Evolution of Argentina's Integrated Energy-Water-Land Systems

This study seeks to understand how Argentina’s energy, water, and land (EWL) systems will co-evolve under a representative array of human and earth system influences, including socioeconomic change, climate change, and climate policy. To capture Argentina’s sub-national EWL dynamics in the context of global change, we couple the Global Change Analysis Model with a suite of consistent, gridded sectoral downscaling models to explore multiple stakeholder-engaged scenarios. Across scenarios, Argentina has the economic opportunity to use its vast land resources to satisfy growing domestic and international demand for crops, such as oil (e.g., soy) and biomass. The human (rather than earth) system produces the most dominant changes in mid-century EWL resource use. A Reference scenario characterized by modest socioeconomic growth projects a 40% increase in Argentina’s agricultural production by 2050 (relative to 2020) by using 50,000 km 2 of additional cropland and 40% more water. A Climate Policy scenario designed to achieve net-zero carbon emissions globally shortly after mid-century projects that Argentina could use 100,000 km 2 of additional land (and 65% more water) to grow biomass and other crops. The burden of navigating these national opportunities and challenges could fall disproportionately on a subset of Argentina’s river basins. The Colorado and Negro basins could experience moderate-to-severe water scarcity as they simultaneously navigate substantial irrigated crop demand growth and climate-induced declines in natural water availability. Argentina serves as a generalizable testbed to demonstrate that multi-scale EWL planning challenges can be identified and managed more effectively via integrated analysis of coupled human-earth systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Conceptual Design of an Integrated Nuclearhydrogen Production Plant Using the Sulfur Cycle Water Decomposition System

A hydrogen production plant was designed based on a hybrid electrolytic-thermochemical process for decomposing water. The sulfur cycle water decomposition system is driven by a very high temperature nuclear reactor that provides 1,283 K helium working gas. The plant is sized to approximately ten million standard cubic meters per day of electrolytically pure hydrogen and has an overall thermal efficiently of 45.2 percent. The economics of the plant were evaluated using ground rules which include a 1974 cost basis without escalation, financing structure and other economic factors. Taking into account capital, operation, maintenance and nuclear fuel cycle costs, the cost of product hydrogen was calculated at $5.96/std cu m for utility financing. These values are significantly lower than hydrogen costs from conventional water electrolysis plants and competitive with hydrogen from coal gasification plants.

Farbman, G. H.↗

Conceptual design of a water treatment system to support a manned Mars colony

The initial tasks addressed by the Prairie View A&M University team were the conceptual design of a breathable-air manufacturing system, a means of drilling for underground water, and a method for storing water for future use. Subsequently, the design objective of the team for the 1987-1988 academic year was the conceptual design of an integrated system for the supply of quality water for biological consumption, farming, residential and industrial use. The source of water for these applications is assumed to be artesian or subsurface. The first step of the project was to establish design criteria and major assumptions. The second step of the effort was to generate a block diagram of the expected treatment system and assign tasks to individual students. The list of processes for water purification and wastewater treatment given above suggests that there will be a need for on-site chemicals manufacturing for ion-exchange regeneration and disinfection. The third step of the project was to establish a basis for the design capacity of the system. A total need of 10,000 gal/day was assumed to be required. It was also assumed that 30,000 gallon raw-water intake volume is needed to produce the desired effluent volume.

Source record↗