Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Einstein observations of the soft X-ray background close to the Galactic plane

A map of the soft X-ray emission along a Galactic meridian within + or - 3 deg of the Galactic plane is presented. An excess of diffuse M-band emission is found at low latitudes which exhibits a resolved, double-peaked profile that is roughly symmetric about b = 0 deg with a half-width about 1-2 deg. The integrated intensity derived for that band for this component is roughly 3-4 times the dip in intensity expected due to absorption of the extragalactic background in the plane at these energies. Assuming that this excess is characteristic of the whole Galactic plane, model fits are performed so as to derive constraints on the scale height and volume emissivity of the X-ray emitting material. The present results are compared with those inferred from observations of the harder 2-10 keV background.

Kahn, S. M.↗

Lava flow-field morphological classification and interpretation: Examples from Venus

Recent analyses suggest that thermal constraints will act to limit the maximum length of an advancing lava flow being fed at a given volume or mass effusion rate from a vent. These constraints can be characterized through the Gratz number, which has a large value at the vent and decreases down flow; under a wide range of conditions, motion apparently ceases when the Gratz number has decreased to a value close to 300. In cooling-limited flows, effusion from the vent should be steady; the flow front thickens, eventually stops due to this cooling, and the central channel does not drain. If the vent remains active, a break-out flow will form from some point on the margin of the initial flow unit. If flows on planetary surfaces can be shown to be cooling limited, eruption rates can be estimated. In this analysis, we illustrate the morphological characteristics of various flow configurations, and we describe the application of these concepts to a flow length histogram for a hypothetical flow field and then apply this to an example on Venus.

Head, J. W.↗

A PC program to optimize system configuration for desired reliability at minimum cost

High reliability is desired in all engineered systems. One way to improve system reliability is to use redundant components. When redundant components are used, the problem becomes one of allocating them to achieve the best reliability without exceeding other design constraints such as cost, weight, or volume. Systems with few components can be optimized by simply examining every possible combination but the number of combinations for most systems is prohibitive. A computerized iteration of the process is possible but anything short of a super computer requires too much time to be practical. Many researchers have derived mathematical formulations for calculating the optimum configuration directly. However, most of the derivations are based on continuous functions whereas the real system is composed of discrete entities. Therefore, these techniques are approximations of the true optimum solution. This paper describes a computer program that will determine the optimum configuration of a system of multiple redundancy of both standard and optional components. The algorithm is a pair-wise comparative progression technique which can derive the true optimum by calculating only a small fraction of the total number of combinations. A designer can quickly analyze a system with this program on a personal computer.

Hills, Steven W.↗

Fan Beam Emission Tomography Demonstrated Successfully in the Reduced-Gravity Environment of Drop Towers

Fires onboard manned spacecraft and launch vehicles are a particularly feared hazard because one cannot jump ship while in orbit 240 nmi above the Earth at 17 000 mph! Understanding the physical properties of fires in free fall and on orbit is, therefore, a very important endeavor for NASA s Human Exploration and Development of Space (HEDS) enterprise. However, detailed information concerning the structure of microgravity fires remained elusive until recently since robustness, limited power, limited volume, and limited mass place severe constraints on diagnostic equipment for use in space and in NASA Glenn Research Center s reduced-gravity facilities. Under NASA Research Associate funding since 2001, En'Urga, Inc. (Dr. Sivathanu, principal investigator, and Dr. Lim, co-investigator) in collaboration with Glenn (Dr. Feikema, coinvestigator) have successfully demonstrated a new technology for use in microgravity combustion. A midinfrared scanning spectrometer has been developed by En'Urga and tested at Glenn to measure 30 spectra per second at different spatial locations in a flame from 1.8 to 4.8 microns.

Feikema, Douglas A.↗

SmallSat Precision Navigation with Low-Cost MEMS IMU Swarms

The continued advancement of small satellite-based science missions requires the solution to a number of important technical challenges. Of particular note is that small satellite missions are characterized by tight constraints on cost, mass, power, and volume that make them unable to fly the high-quality Inertial Measurement Units (IMUs) required for orbital missions demanding precise orientation and positioning. Instead, small satellite missions typically fly low-cost Micro-Electro-Mechanical System (MEMS) IMUs. Unfortunately, the performance characteristics of these MEMS IMUs make them ineffectual in many spaceflight applications when employed in a single IMU system configuration.

Precision navigation↗

ATLAS Flight Science Receiver Algorithms

This is the basis document for the ATLAS Receiver Algorithms. ATLAS is the single instrument on the ICESat-2 mission. The Receiver (Rx) Algorithms select the signal location in real-time and instruct the hardware to telemeter a vertical band of received time-tags about this signal location. The algorithms are implemented in the Flight Software (FSW) and in the hardware of the Photon Counting Electronics (PCE) cards. The sole purpose of the algorithms is to reduce the telemetry data volume to fit within the downlink constraint while maximizing the probability of downlinking surface signal. All versions of the Receiver Algorithms from version 2.8 onward incorporate our best knowledge of the ATLAS hardware at this time. It presents algorithms that, based on current Simulator testing, satisfy all of the requirements for the Rx Algorithms. Testing during ATLAS Instrument Integration and Testing with the hardware and software implementation of the Rx Algorithms revealed characteristics and responses that required changes to the Rx Algorithms and this document, which are captured in the change record below.All relevant documentation for the Receiver Algorithms can be found on the ICESat-2 Technical Data Management System (TDMS) under the ATLAS Algorithms subsystem.The launch version of the FSW (version 3.1.0) is based upon version 3.7c of this document.

Mcgarry, Jan L.↗

CLINICAL DECISION SUPPORT: PATH TO FUNCTIONAL REQUIREMENTS

Long-duration, deep-space exploration missions present significant challenges to crew health and performance. These challenges include the individual and combined effects of microgravity, radiation exposure, isolation, limited resources (mass, volume, power, data and crew time), limited options for evacuation and those associated with delayed or constrained communications, all of which demand greater crew autonomy. Specifically, as the communication delays intensify the further we explore space, the unqualified need for Earth-independent medical operations focused on autonomous diagnosis, treatment and prevention will be key to mission continuation and success. To augment the requisite knowledge, skills and abilities (KSAs) of a time-constrained crew operating under stressful conditions, combatting fatigue, and facing a potential medical crisis, a robust clinical decision support system (CDSS) is a probable solution that would facilitate, guide and inform Earth-independent medical operations, while assisting crewmembers through various clinical presentations. The Exploration Medical Capability (ExMC) Element of the Human Research Program (HRP) is expanding the boundaries of space medical systems to advance the care of astronauts on future exploration missions beyond low Earth orbit. ExMC is actively identifying and testing next-generation medical care and crew health maintenance technologies. The Clinical Decision Support (CDS) project addresses gap Medical-701 within the Inflight Medical Conditions risk: “Enhance medical capabilities within an exploration medical system.” Though mass, volume, and power will face increasing constraints, the projected computational capabilities of spacecraft systems will increase exponentially as information technology continues to advance this decade and beyond. Hence, data, software and computational resources will play an essential and synergistic role in maintaining crew health, wellness and performance in deep space missions. The focus of the CDS project is to develop recommended requirements for an in-vehicle CDSS that acts as a ‘virtual assistant’ for delivering optimal health, performance and medical care during exploration missions. The CDSS is envisioned as an integrated, software-based tool deployed on a laptop computer or handheld device. The CDSS will assist the crew and ground support when interacting with knowledge/databases (e.g. records, pharmacy, schedule), instrumentation (e.g. imaging, physiological monitoring devices), and habitat (e.g. wellness system, task performance system) and vehicle systems (e.g. environmental system, communication system). In addition, the human interface will employ a context-based approach that accounts for the crew’s situation. Thus, extraneous and clinically/operationally non-relevant information are reduced to avoid an increase in cognitive load. The framework of an ideal spaceflight CDSS is to include core and advanced analytical features that incorporate work from collaborators yet maintain a flexible platform for integrating new technology in the future. In fiscal year 2021 (FY21), the CDS project identified requirements through two primary mechanisms: (i) the development of software implementation prototypes and (ii) the application of systems engineering processes. The CDS project developed and tested a series of increasingly complex system prototypes that were based on use cases derived from the CDSS concept of operations (ConOps). These software implementations yielded insights on CDSS functionality as well as lessons learned that provided the initial requirements for CDSS capability. By applying a systems engineering (SE) approach, medical scenarios provided in the ConOps and the use cases for software implementation underwent functional decomposition to identify CDSS functionality. Also, systems-based modeling language (SysML) tools such as activity diagrams were developed from the same ConOps and use cases to identify CDSS functionality. The lessons learned from software implementation defined both specific requirements and broad areas of requirements. Within these defined broad requirement areas, further analysis of the SE products identified specific capability that resulted in the final functional requirements. In summary, the software prototypes, functional decomposition of the ConOps and use cases, and SysML diagrams provided the basis for the CDSS requirements developed in FY21. In the upcoming year, these requirements will be refined for their final ExMC baseline review in latter FY22.

clinical decision support↗

Clinical Decision Support: Path to Functional Requirements

Long-duration, deep-space exploration missions present significant challenges to crew health and performance. These challenges include the individual and combined effects of microgravity, radiation exposure, isolation, limited resources (mass, volume, power, data and crew time), limited options for evacuation and those associated with delayed or constrained communications, all of which demand greater crew autonomy. Specifically, as the communication delays intensify the further we explore space, the unqualified need for Earth-independent medical operations focused on autonomous diagnosis, treatment and prevention will be key to mission continuation and success. To augment the requisite knowledge, skills and abilities (KSAs) of a time-constrained crew operating under stressful conditions, combatting fatigue, and facing a potential medical crisis, a robust clinical decision support system (CDSS) is a probable solution that would facilitate, guide and inform Earth-independent medical operations, while assisting crewmembers through various clinical presentations. The Exploration Medical Capability (ExMC) Element of the Human Research Program (HRP) is expanding the boundaries of space medical systems to advance the care of astronauts on future exploration missions beyond low Earth orbit. ExMC is actively identifying and testing next-generation medical care and crew health maintenance technologies. The Clinical Decision Support (CDS) project addresses gap Medical-701 within the Inflight Medical Conditions risk: “Enhance medical capabilities within an exploration medical system.” Though mass, volume, and power will face increasing constraints, the projected computational capabilities of spacecraft systems will increase exponentially as information technology continues to advance this decade and beyond. Hence, data, software and computational resources will play an essential and synergistic role in maintaining crew health, wellness and performance in deep space missions. The focus of the CDS project is to develop recommended requirements for an in-vehicle CDSS that acts as a ‘virtual assistant’ for delivering optimal health, performance and medical care during exploration missions. The CDSS is envisioned as an integrated, software-based tool deployed on a laptop computer or handheld device. The CDSS will assist the crew and ground support when interacting with knowledge/databases (e.g. records, pharmacy, schedule), instrumentation (e.g. imaging, physiological monitoring devices), and habitat (e.g. wellness system, task performance system) and vehicle systems (e.g. environmental system, communication system). In addition, the human interface will employ a context-based approach that accounts for the crew’s situation. Thus, extraneous and clinically/operationally non-relevant information are reduced to avoid an increase in cognitive load. The framework of an ideal spaceflight CDSS is to include core and advanced analytical features that incorporate work from collaborators yet maintain a flexible platform for integrating new technology in the future. In fiscal year 2021 (FY21), the CDS project identified requirements through two primary mechanisms: (i) the development of software implementation prototypes and (ii) the application of systems engineering processes. The CDS project developed and tested a series of increasingly complex system prototypes that were based on use cases derived from the CDSS concept of operations (ConOps). These software implementations yielded insights on CDSS functionality as well as lessons learned that provided the initial requirements for CDSS capability. By applying a systems engineering (SE) approach, medical scenarios provided in the ConOps and the use cases for software implementation underwent functional decomposition to identify CDSS functionality. Also, systems-based modeling language (SysML) tools such as activity diagrams were developed from the same ConOps and use cases to identify CDSS functionality. The lessons learned from software implementation defined both specific requirements and broad areas of requirements. Within these defined broad requirement areas, further analysis of the SE products identified specific capability that resulted in the final functional requirements. In summary, the software prototypes, functional decomposition of the ConOps and use cases, and SysML diagrams provided the basis for the CDSS requirements developed in FY21. In the upcoming year, these requirements will be refined for their final ExMC baseline review in latter FY22.

Clinical decision support↗

Loop quantization of vacuum Bianchi I cosmology

We analyze the loop quantization of the family of vacuum Bianchi I spacetimes, a gravitational system of which classical solutions describe homogeneous anisotropic cosmologies. We rigorously construct the operator that represents the Hamiltonian constraint, showing that the states of zero volume completely decouple from the rest of quantum states. This fact ensures that the classical cosmological singularity is resolved in the quantum theory. In addition, this allows us to adopt an equivalent quantum description in terms of a well-defined densitized Hamiltonian constraint. This latter constraint can be regarded in a certain sense as a difference evolution equation in an internal time provided by one of the triad components, which is polymerically quantized. Generically, this evolution equation is a relation between the projection of the quantum states in three different sections of constant internal time. Nevertheless, around the initial singularity the equation involves only the two closest sections with the same orientation of the triad. This has a double effect: on the one hand, physical states are determined just by the data on one section, on the other hand, the evolution defined in this way never crosses the singularity, without the need of any special boundary condition. Finally, we determine the inner product and the physical Hilbert space employing group averaging techniques, and we specify a complete algebra of Dirac observables. This completes the quantization program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design Considerations for Phase Change Material-Incorporated Heat Exchangers in Water Heating

In recent years, the buildings sector has seen major pushes towards decarbonization through innovations that promote deep electrification. 20% of an average household's energy use comes from water heating, and in the US, over half of all households still use gas water heaters. Of those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. However, HPWHs tend to have larger dimensions, preventing current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). This study outlines the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. To ensure optimal PCM utilization and tank storage capacity, this works seeks to co-maximize surface area and PCM volume; therefore, this research targets triply periodic minimal surface (TPMS) lattices, which boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives. Our current results indicate that tuning lattice properties can effectively produce geometries that provide enough energy storage to achieve a 50-gallon capacity out of a 40-gallon HPWH, even when placing the PCM heat exchanger inside the tank. Additionally, we demonstrate successful fabrication of lattices with these tuned properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cosmological constraints from a joint DESI DR1 Full-Shape and DR2 BAO

We present a cosmological analysis combining full-shape (FS) clustering measurements from the Dark Energy Spectroscopic Instrument (DESI) DR1 with baryon acoustic oscillation (BAO) measurements from DESI DR2. To achieve a robust combination that accounts for the correlation between the two data releases, we employ the ShapeFit compression method and estimate the joint covariance using EZmocks. This compressed approach inherently mitigates the prior volume effects that have previously dominated Bayesian constraints from DESI data with minimal external priors. Consequently, we obtain — for the first time within a Bayesian framework — reliable DESI-only constraints on extensions to ΛCDM using only a Big Bang Nucleosynthesis prior on the baryon density and a wide prior on the spectral index. In flat ΛCDM, we find Ω m = 0.3035 ± 0.0085, h = 0.6876 ± 0.0059, and σ 8 = 0.822 ± 0.034. For the w 0 w a CDM dynamical dark energy model, we measure w 0 = -0.49 ± 0.25 and w a = -1.52 ± 0.77, improving constraints by ∼ 30% relative to the analogous DR1 measurement and reducing the discrepancy with ΛCDM to 1.4σ when compared to BAO only analyses. We also report competitive limits on the sum of neutrino masses and spatial curvature. This work demonstrates that the ShapeFit compression provides a prior-robust and computationally efficient pathway to constrain beyond-ΛCDM physics with large-scale structure.

baryon acoustic oscillations↗

Cosmic Voids in the SDSS DR12 BOSS Galaxy Sample: the Alcock–Paczyński test

We apply the Alcock–Paczyński (AP) test to stacked voids identified using the final data release (DR12) of the Baryon Oscillation Spectroscopic Survey (BOSS). We also use 1000 mock galaxy catalogs that match the geometry, density, and clustering properties of the BOSS sample in order to characterize the statistical uncertainties of our measurements and take into account systematic errors such as redshift space distortions. For both BOSS data and mock catalogs, we use the ZOBOV algorithm to identify voids, we stack together all voids with effective radii of 30--100 h{sup −1} Mpc in the redshift range of 0.43–0.7, and we accurately measure the shape of the stacked voids. Our tests with the mock catalogs show that we measure the stacked void ellipticity with a statistical precision of 2.6%. The stacked voids in redshift space are slightly squashed along the line of sight, consistent with previous studies. We repeat this measurement of stacked void shape in the BOSS data, assuming several values of Ω{sub m} within the flat ΛCDM model, and we compare this to the mock catalogs in redshift space to perform the AP test. We obtain a constraint of Ω{sub m}=0.38{sub −0.15}{sup +0.18} at the 68% confidence level from the AP test. We discuss the sources of statistical and systematic noise that affect the constraining power of this method. In particular, we find that the measured ellipticity of stacked voids changes more weakly with cosmology than the standard AP prediction, leading to significantly weaker constraints. We discuss how constraints will improve in future surveys with larger volumes and densities.

79 ASTRONOMY AND ASTROPHYSICS↗

Making Small-Volume Heat Pump Water Heaters Larger: A Design Framework for Integrated Phase Change Material Heat Exchangers

Those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. One major barrier to wider HPWH adoption is the added equipment required, which prevents current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). PCMs have been studied extensively in building envelope and HVAC systems, but remain a nascent technology in residential water heating. While water itself has a uniquely high energy storage capacity, PCMs have an even higher energy storage density, thus providing the potential to elevate the performance of 40-gallon HPWHs to that of 50-gallon or larger tanks. This research is part of a larger project that seeks to utilize thermal energy storage to enable decarbonized water heating in low-income communities. In this study, we outline the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. In order to ensure optimal PCM utilization and tank storage capacity, we focus here on co-maximizing surface area and PCM volume in the heat exchangers; therefore, this research targets triply periodic minimal surface (TPMS) lattices. TPMS lattices boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries and offer highly tailorable designs; thus, they pair well with the growing field of additive manufacturing, or 3D printing. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives.

25 ENERGY STORAGE↗

Luna 24 origins - Some trace element constraints

Luna 24 basaltic material originated in the particular volume of the lunar crust that produced Apollo 11 and Luna 16 basaltic material; it has the same Clr/P2O5 (r = residual) signature. Ru-Os contents (Barsukov et al., 1977) and a number of radiogenic age measurements place Luna 24 basalt origins stratigraphically in a layer between those from which Apollo 15 and Apollo 11 and 17 basalts were derived.

Jovanovic, S.↗

Renal Toxicity of Adjuvant Chemoradiotherapy With Cisplatin in Gastric Cancer

Purpose: Adjuvant, 5-fluorouracil (5-FU)-based chemoradiotherapy for completely resected high-risk gastric adenocarcinoma has been shown to improve survival in a randomized Intergroup trial. However, the results still showed an unsatisfactory outcome. On the basis of previously reported results of a Phase II trial using a more aggressive, cisplatin-containing chemoradiotherapy schedule, we investigated the effects of this approach on long-term renal function. Patients and Methods: Between December 2000 and September 2003, 27 patients were treated at Tuebingen University in a Phase II multicenter trial investigating adjuvant chemoradiotherapy. The adjuvant chemoradiotherapy consisted of two cycles of adjuvant 5-FU, folinic acid, cisplatin (200 mg/m{sup 2}), and paclitaxel before and after radiotherapy (45 Gy in 1.8-Gy fractions) with daily concomitant 5-FU (225 mg/m{sup 2}/24 h). A dose constraint of {<=}12 Gy for 37.5% of the functional volume of both kidneys was used. Renal function was assessed by the changes in creatinine and creatinine clearance during follow-up. Results: The prescribed 45 Gy was administered to 100% of the patients, and the cumulative cisplatin dose was 200 mg/m{sup 2} in 74% of all patients. In 89%, the constraints concerning the renal absorbed doses were met. The median follow-up for the creatinine and clearance values was 30 and 26 months, respectively. The creatinine values tended to worsen over time without reaching critical levels. We were unable to demonstrate a significant dose-response relationship for renal damage in the tested dose range. Conclusions: Using a dose constraint of {<=}12 Gy for 37.5% of the functional volume of both kidneys appears to be safe at a median follow-up of 2 years for a cumulative cisplatin dose of 200 mg/m{sup 2} administered before and after simultaneous 5-FU and radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric quality, accuracy, and deliverability of modulated radiotherapy treatments for spinal metastases

Cancer often metastasizes to the vertebra, and such metastases can be treated successfully using simple, static posterior or opposed-pair radiation fields. However, in some cases, including when re-irradiation is required, spinal cord avoidance becomes necessary and more complex treatment plans must be used. This study evaluated 16 sample intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans designed to treat 6 typical vertebral and paraspinal volumes using a standard prescription, with the aim of investigating the advantages and limitations of these treatment techniques and providing recommendations for their optimal use in vertebral treatments. Treatment plan quality and beam complexity metrics were evaluated using the Treatment And Dose Assessor (TADA) code. A portal-imaging–based quality assurance (QA) system was used to evaluate treatment delivery accuracy, and radiochromic film measurements were used to provide high-resolution verification of treatment plan dose accuracy, especially in the steep dose gradient regions between each vertebral target and spinal cord. All treatment modalities delivered approximately the same doses and the same levels of dose heterogeneity to each planning target volume (PTV), although the minimum PTV doses in the vertebral plans were substantially lower than the prescription, because of the requirement that the plans meet a strict constraint on the dose to the spinal cord and cord planning risk volume (PRV). All plans met required dose constraints on all organs at risk, and all measured PTV-cord dose gradients were steeper than planned. Beam complexity analysis suggested that the IMRT treatment plans were more deliverable (less complex, leading to greater QA success) than the VMAT treatment plans, although the IMRT plans also took more time to deliver. The accuracy and deliverability of VMAT treatment plans were found to be substantially increased by limiting the number of monitor units (MU) per beam at the optimization stage, and thereby limiting beam modulation complexity. The VMAT arcs that were optimized with MU limitation had higher QA pass rates as well as higher modulation complexity scores (less complexity), lower modulation indices (less modulation), lower MU per beam, larger beam segments, and fewer small apertures than the VMAT arcs that were optimized without MU limitation. It is recommended that VMAT treatments for vertebral volumes, where the PTV abuts or surrounds the spinal cord, should be optimized with MU limitation. IMRT treatments may be preferable to the VMAT treatments, for dosimetry and deliverability reasons, but may be inappropriate for some patients because of their increased treatment delivery time.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Novel Method for Predicting Late Genitourinary Toxicity After Prostate Radiation Therapy and the Need for Age-Based Risk-Adapted Dose Constraints

Background: There are no well-established normal tissue sparing dose–volume histogram (DVH) criteria that limit the risk of urinary toxicity from prostate radiation therapy (RT). The aim of this study was to determine which criteria predict late toxicity among various DVH parameters when contouring the entire solid bladder and its contents versus the bladder wall. The area under the histogram curve (AUHC) was also analyzed. Methods and Materials: From 1993 to 2000, 503 men with prostate cancer received 3-dimensional conformal RT (median follow-up time, 71 months). The whole bladder and the bladder wall were contoured in all patients. The primary endpoint was grade ≥2 genitourinary (GU) toxicity occurring ≥3 months after completion of RT. Cox regressions of time to grade ≥2 toxicity were estimated separately for the entire bladder and bladder wall. Concordance probability estimates (CPE) assessed model discriminative ability. Before training the models, an external random test group of 100 men was set aside for testing. Separate analyses were performed based on the mean age (≤ 68 vs >68 years). Results: Age, pretreatment urinary symptoms, mean dose (entire bladder and bladder wall), and AUHC (entire bladder and bladder wall) were significant (P<.05) in multivariable analysis. Overall, bladder wall CPE values were higher than solid bladder values. The AUHC for bladder wall provided the greatest discrimination for late bladder toxicity when compared with alternative DVH points, with CPE values of 0.68 for age ≤68 years and 0.81 for age >68 years. Conclusion: The AUHC method based on bladder wall volumes was superior for predicting late GU toxicity. Age >68 years was associated with late grade ≥2 GU toxicity, which suggests that risk-adapted dose constraints based on age should be explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗