Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLATILE MATTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

497 records · Page 28

Purely electronic insulator-metal transition in rutile VO 2

Volatile resistive switching in neuromorphic computing can be tuned by external stimuli such as temperature or electric-field. However, this type of switching is generally coupled to structural changes, resulting in slower reaction speed and higher energy consumption when incorporated into an electronic device. The vanadium dioxide (VO 2 ), which has near room temperature metal-insulator transition (MIT), is an archetypical volatile resistive switching system. Here, we demonstrate an isostructural MIT in an ultrathin VO 2 film capped with a photoconductive cadmium sulfide (CdS) layer. Transmission electron microscopy, resistivity experiments, and first-principles calculations show that the hole carriers induced by CdS photovoltaic effect are driving the MIT in rutile VO 2 . The insulating-rutile VO 2 phase has been proved and can remain stable for hours. Our finding provides a new approach to produce purely electronically driven MIT in VO 2 , and widens its applications in fast-response, low-energy neuromorphic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development and Rigorous Validation of Modules for Predicting Organic Aerosol CCN Activity from Molecular Properties

The indirect interaction of anthropogenic aerosols with clouds (aerosol indirect forcing) represents one of the main uncertainties in climate projections, and reducing this uncertainty requires improved understanding of the aerosol life cycle, including atmospheric aging and the ability to nucleate cloud droplets or crystals. A key parameter that links the chemical properties of aerosol to its nucleating properties, and ultimately to aerosol indirect forcing, is its hygroscopicity (ability to uptake water). One way to compare and systematize the ability of various chemical compounds or particle types to nucleate cloud drops is via the hygroscopicity parameter κ, which can be used directly in global models to simulate aerosol indirect forcing. In this project we further investigated the relationships between the chemical composition of organic aerosol particles, which are known to be important components of atmospheric particulate matter, and their ability to serve as cloud condensation nuclei (CCN). In particular, we isolated the role of viscosity on κ by applying methods similar to those we used previously in our DOE/ASR research. Our motivation for the focus on viscosity was through its link to particle phase state. Particle phase affects water uptake on timescales relevant to the laboratory and also likely relevant to atmospheric processes, with reduced apparent hygroscopicities for semisolid and solid particles, compared with liquid particles. Water uptake itself affects viscosity, an important feedback that we explored in this project. The objectives of the project were as follows: (1) measure the effects of molecular structure, temperature, and relative humidity on the viscosity of organic aerosol formed via controlled laboratory experiments, (2) measure the effects of organic aerosol viscosity on water uptake and CCN activity above and below water saturation, (3) further develop the κ parameterization of organic aerosol hygroscopicity to include viscosity/phase, and (4) experimentally validate the κ parameterization for organic aerosol with chemical composition ranging from relatively simple to complex. It was proposed that particle viscosity exerts a kinetic control on equilibrium water uptake. High viscosity was expected to delay water uptake based on diffusional limitations. This would manifest itself in reduced observed CCN activity or κ. Understanding the interplay between water content and viscosity (composition control on particle viscosity) and between viscosity and equilibrium water content (diffusional control on water uptake) were the overall science objectives of this grant. Targeted experiments were carried out to test the kinetic control hypothesis. These experiments included studies that explicitly measured the equilibration time scale of water uptake, and experiments that tested the role of viscous particle coatings on the observed CCN activity. From the combined work, it is concluded that mass transfer limitations by glassy organic particles are unlikely to affect cloud droplet activation near laboratory temperatures. This implies that viscosity does not need to be included in parameterizations that link particle chemical composition and κ. A parameterization to predict κ through the UNIFAC group contribution method was developed with previous ASR funding. As planned, this computational module was further developed and validated here through targeted laboratory studies. The computational module has been made available as free software under the GNU public license. A database of κ-values to aid model development has been compiled and is available online via an open access model. In conducting this work, significant effort was made to understand how aerosol composition, including the associated aerosol water content, affects viscosity. This included a study detailing the influence of functional group composition on organic aerosol viscosity. We identified a strong link between volatility and viscosity. Functional groups responsible for low vapor pressure also promote high viscosity. Specifically, carboxylic acid and hydroxyl groups were identified as major contributors to high viscosity. Several studies were carried out to characterize the link between composition and the glass-to-liquid phase transition. Compositions tested include models of organic/inorganic particles and models of complex organic aerosol formed through secondary processes. A simple computational model to predict the amorphous phase diagram was developed and tested. Excellent agreement between model and measurements was obtained for organic/inorganic mixtures. The computational model is simple enough to be included in global model simulations. However, constraints of input parameters such as the Gordon-Taylor constant for binary mixtures for a wide range of complex mixtures have not yet been fully evaluated. Combined, the performed work provides new constraints on the amorphous phase state of organic aerosols.

54 ENVIRONMENTAL SCIENCES↗

Topical Report – Findings on Subtask 2.7 – Wet ESP and Aerosol Testing at Coal Creek Station

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion carbon capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery. The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the unique components present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants by contributing to aerosol formation. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and flue gas particulate provides nucleation sites where amine vapors can condense as aerosols. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, particulate components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to fully characterize aerosol behavior with various control technologies installed to better optimize aerosol mitigation technology for CO 2 capture. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on mitigating formation of problematic aerosols at Great River Energy’s Coal Creek Station, upstream of the PCCC system. Determine the effectiveness of the Mitsubishi Heavy Industries (MHI) proprietary amine emission reduction unit (AERU) as a postcapture solvent recovery system for reducing aerosol emissions and extending solvent life downstream of the PCCC system. Determine the impact of aerosols on the efficiency and degradation products of both commercial and advanced solvents within the PCCC system. Work was conducted at Coal Creek Station Unit 1 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then optionally routed through a WESP before passing to the CO 2 absorber columns. The MHI solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . Flue gas exiting the absorber column was routed to MHI’s proprietary AERU to recover entrained solvent. The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Particulate was measured, collected, and analyzed from multiple locations throughout the pilot-scale system. Unlike the performance observed in prior work, the inlet FGD and DCC did not remove significant particulate matter from the flue gas. This appears to be due to a difference in the nature of the particulate. The DCC seemed to increase particulate size and count, most likely owing to water condensing onto the surfaces of fly ash particles. When the WESP was operated, it achieved >95% particulate capture. Very little particulate matter or indications of solvent were detected at the AERU outlet. When operating with advanced KS 21 solvent, the particulate material at the AERU outlet was even further decreased. Solvent analysis showed that some species derived from flue gas and ash were slowly concentrating in the solvent over the duration of the test. The levels observed were reported to be within expected ranges and were not of concern to MHI. A high-level techno-economic assessment of installing CO 2 capture at Coal Creek Station suggested that, when using a standard monoethanolamine (MEA)-based solution with simple heat integration, the energy penalty to net generation would be 34%. The bulk of this was due to steam losses for regenerating solvent, followed by parasitic electrical demand for CO 2 compression and then by increased parasitic load for pushing flue gas through the absorber column. These demands could be decreased with a more advanced solvent that exhibits lower heat of regeneration and lower pressure drop than does a simple MEA solution. Further energy could be saved with more thorough heat integration to recover useful energy from the steam used for solvent regeneration. Installing a WESP was predicted to increase the cost of electricity by nearly $5/MWh. This would become cost-effective if solvent losses were roughly 10 times the baseline estimate when not using a WESP but could be returned to baseline by installing the WESP. Piping CO 2 for storage in more favorable geology could help with carbon capture and storage economics. Although storing off-site would necessitate construction of a CO 2 transport pipeline, the cost of this pipeline might be more than offset by reducing the number of wells required, the depths of the wells required, and the electrical demand for the CO 2 compressor. Additional factors that favor off-site storage costs include smaller expected CO 2 plume sizes, which translates to less monitoring and fewer landowner agreements. More detailed assessment of the specific geology in the region under and around Coal Creek Station would be needed to accurately assess the costs and benefits of different storage site options. This subtask was cofunded through the Energy & Environmental Research Center–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission.

Strege, Joshua↗

Coupling field and laboratory measurements to estimate the emission factors of identified and unidentified trace gases for prescribed fires

Vegetative fuels commonly consumed in prescribed fires were collected from five locations in the southeastern and southwestern U.S. and burned in a series of 77 fires at the U.S. Forest Service Fire Sciences Laboratory in Missoula, Montana. The particulate matter (PM2.5) emissions were measured by gravimetric filter sampling with subsequent analysis for elemental carbon (EC), organic carbon (OC), and 38 elements. The trace gas emissions were measured with a large suite of state-of-the-art instrumentation including an open-path Fourier transform infrared (OP FTIR) spectrometer, proton-transfer-reaction mass spectrometry (PTR-MS), proton-transfer ion-trap mass spectrometry (PIT-MS), negative-ion proton-transfer chemical-ionization mass spectrometry (NI-PT-CIMS), and gas chromatography with MS detection (GC-MS). 204 trace gas species (mostly non-methane organic compounds (NMOC)) were identified and quantified with the above instruments. An additional 152 significant peaks in the unit mass resolution mass spectra were quantified, but either could not be identified or most of the signal at that molecular mass was unaccounted for by identifiable species. As phase II of this study, we conducted airborne and ground-based sampling of the emissions from real prescribed fires mostly in the same land management units where the fuels for the lab fires were collected. A broad variety, but smaller number of species (21 trace gas species and PM2.5) was measured on 14 fires in chaparral and oak savanna in the southwestern US, as well as pine forest understory in the southeastern US and Sierra Nevada mountains of California. These extensive field measurements of emission factors (EF) for temperate biomass burning are useful both for modeling and to examine the representativeness of our lab fire EF. The lab/field EF ratio for the pine understory fuels was not statistically different from one, on average. However, our lab EF for “smoldering compounds” emitted by burning the semi-arid SW fuels should likely be increased by about a factor of 2.7 to better represent field fires. Based on the lab/field comparison, we present a table with emission factors for 365 pyrogenic species (including unidentified species) for 4 broad fuel types: pine understory, semi-arid shrublands, evergreen canopy, and duff. To our knowledge this is the most complete measurement of biomass burning emissions to date and it should enable improved representation of smoke in atmospheric models. The results provide important insights into the nature of smoke. For example, ~35% (range from 16-71%) of the mass of gas-phase NMOC species was attributed to the species that we could not identify. These unidentified species are likely not represented in most models, but some provision should be made for the fact that they will react in the atmosphere. In addition, the total mass of gas-phase NMOC divided by the mass of co-emitted PM2.5 averaged ~2.6 for the main fire types with a range from ~1.8-8.8. About 36-63% of the NMOC were likely semivolatile or of intermediate volatility. Thus, the gas-phase NMOC represent a large reservoir of potential precursors for secondary formation of organic aerosol. For the one fire in organic soil (Alaskan duff) about 28% of the emitted carbon was present as gas-phase NMOC in contrast to the other fuels for which NMOC accounted for only ~1-3% of emitted carbon. 71% of the mass of NMOC emitted by the smoldering duff was un-identified. The duff results highlight the need to learn more about the emissions from smoldering organic soils. The NMOC/“NOx-as-NO” ratio was consistently about ten for the main fire types when accounting for all NMOC, indicating strongly NOx-limited O3 production conditions. Finally, the fuel consumption per unit area was measured on 6 of the 14 prescribed fires and averaged 7.08 ± 2.09 (1) Mg ha-1.

Yokelson, R. J.↗

Modeling the Impact of the Organic Aerosol Phase State on Multiphase OH Reactive Uptake Kinetics and the Resultant Heterogeneous Oxidation Timescale of Organic Aerosol in the Amazon Rainforest

Accurate predictions of chemical lifetime, i.e., oxidation timescale and change in the mass of organic aerosols (OAs) in atmospheric models, are critical to quantify the impacts of OA on aerosol–cloud interactions, radiative forcing, and air quality. The heterogeneous oxidation of OA by hydroxyl (OH) radicals is a key process governing OA mass changes during their oxidation. Recently, laboratory observations of the OH uptake coefficient (γ OH ) and heterogeneous reaction rate (k het,OH ) for different OA systems with varying phase states have been combined to develop a new parameterization of γ OH and k het,OH as a function of the OA phase state, i.e., viscosity (η OA ). Here, in this work, we use a recently published viscosity prediction framework to analyze the new γ OH and k het,OH parameterization with a box model. Subsequently, we implement this box model to predict γ OH and k het,OH over the Amazon rainforest in the dry-to-wet transition season with both significant biomass burning and biogenic influences. Relevant parameters within our box model are specified based on detailed regional model simulations over the Amazon using the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem). η OA is predicted as a function of species volatility, OA composition (including water uptake) along with ambient relative humidity (RH), and temperature. Based on ambient conditions simulated by WRF-Chem over the entire atmospheric column, we use the box model to predict the upper bounds of the heterogeneous oxidation timescale of OA. Based on previous laboratory measurements, we assume that this heterogeneous OH oxidation causes fragmentation (carbon loss) of OA, followed by the evaporation of the fragmented molecules that results in the exponential decay of OA. We predict that the oxidation timescale of OA is ~1 month near the Earth’s surface in the pristine Amazonian background because of low OH concentrations. But OA is oxidized more rapidly within urban and wildfire plumes near the Earth’s surface with an order of magnitude higher OH concentrations compared to the pristine background, causing the simulated oxidation timescale of OA to be much shorter, ~3–4 days. At 3–5 km altitudes where biomass burning OA is predicted to be semisolid, the heterogeneous oxidation timescale is estimated as ~6 days to 3 weeks and decreases with increasing OH concentrations within plumes. We show that the simulated mass loss of OA is strongly size-dependent, where smaller particles oxidize more rapidly compared to larger particles due to their greater per-particle surface area-to-volume ratio. Increasing urbanization and deforestation in the Amazon in the future might increase OH concentrations in the background Amazon, causing faster oxidation of OA. At higher altitudes above liquid clouds, especially in the upper troposphere where temperatures approach ~250 K, future measurements are needed to reduce the uncertainties related to the mass loss of OA at colder temperatures and low relative humidity conditions due to its heterogeneous OH oxidation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase Synergy Enables Low‐Power Ferroelectric Switching in HfO 2 Epitaxial Films

HfO 2 -based ferroelectric materials have emerged as leading candidates for next-generation non-volatile memory technologies, owing to their nanoscale robust ferroelectricity and complementary metal–oxide–semiconductor (CMOS) compatibility. However, challenges and debates persist in advancing and comprehensively understanding their ferroelectric behavior. In particular, conventional approaches typically regard non-ferroelectric phases as detrimental and primarily focus on suppressing their formation, yet overlooking their potentially synergistic contributions—particularly those of the tetragonal (T) phase. Here, we unambiguously clarify the beneficial role of the T-phase and introduce a phase-boundary engineering strategy that deliberately harnesses it to enhance ferroelectricity in HfO 2 films. By stabilizing optimal coherent boundaries between ferroelectric orthorhombic (O) and T phases in epitaxial La-doped HfO 2 films, we achieve significant improvements in ferroelectric properties—doubling the remanent polarization (P r ∼ 30 µC/cm 2 ) and substantially reducing the coercive field (E c ∼ 3 MV/cm) by 30% compared to low-La doped samples without such boundaries. Atomic-scale electron microscopy reveals the structural nature of the atomically sharp, coherent O–T boundaries. Combined with deep-learning enhanced molecular dynamics simulations, our results unravel that these boundaries facilitate intermediate polarization states that lower the switching energy barrier. Consequently, phase coexistence shifts from an inherent drawback to a tunable design element, offering a broadly applicable route to ultra-low-power HfO 2 -based nanoelectronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL Radiological Response Training Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at the Idaho National Laboratory (INL) Radiological Response Training Range (RRTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K2O, LaBr3, KBr, Cu, Zr, F, Ga, Ga2O3, NaNO2, Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated assuming 12 tests are conducted annually using all 11 material types for a period of 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradioactive chemical

54 ENVIRONMENTAL SCIENCES↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL National Security Test Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at two locations at the Idaho National Laboratory (INL) National Security Test Range (NSTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K 2 O, LaBr 3 , KBr, Cu, Zr, F, Ga, Ga 2 O 3 , NaNO 2 , Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated based on the assumption that 12 tests are conducted annually using all 11 material types for 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files, are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradradioactive chemicals modeled. And finally, the calculations assume all 12 tests will be performed at the same place at both locations, and all 11 radioactive material types will be used for each test. This is conservative because it is anticipated that no more than two material types will be used per test.

99 GENERAL AND MISCELLANEOUS↗

A spectroscopic study of ethylene destruction and by-product generation using a three-stage atmospheric packed-bed plasma reactor

Using a three-stage dielectric packed-bed plasma reactor at atmospheric pressure, the destruction of ethylene, a typical volatile organic compound, and the generation of major by-products have been studied by means of Fourier Transform Infrared Spectroscopy. A test gas mixture air at a gas flow of 1 slm containing 0.12% humidity with 0.1% ethylene has been used. In addition to the fragmentation of the precursor gas, the evolution of the concentration of ten stable reaction products, CO, CO{sub 2}, O{sub 3}, NO{sub 2}, N{sub 2}O, HCN, H{sub 2}O, HNO{sub 3}, CH{sub 2}O, and CH{sub 2}O{sub 2} has been monitored. The concentrations of the by-products range between 5 ppm, in the case of NO{sub 2}, and 1200 ppm, for H{sub 2}O. By the application of three sequentially working discharge cells at a frequency of f = 4 kHz and voltage values between 9 and 12 kV, a nearly complete decomposition of C{sub 2}H{sub 4} could be achieved. Furthermore, the influence of the specific energy deposition (SED) on the destruction process has been studied and the maximum value of SED was about 900 J l{sup -1}. The value of the characteristic energy {beta}, characterizing the energy efficiency of the ethylene destruction in the reactor, was found to be 330 J l{sup -1}. It was proven that the application of three reactor stages suppresses essentially the production of harmful by-products as formaldehyde, formic acid, and NO{sub 2} compared to the use of only one or two stages. Based on the multi-component detection, the carbon balance of the plasma chemical conversion of ethylene has been analyzed. The dependence of the fragmentation efficiencies of ethylene (R{sub F}(C{sub 2}H{sub 4}) = 5.5 Multiplication-Sign 10{sup 19} molecules J{sup -1}) and conversion efficiencies to the produced molecular species (R{sub C} = (0.1-3) Multiplication-Sign 10{sup 16} molecules J{sup -1}) on the discharge conditions could be estimated in the multistage plasma reactor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Precision Oxygen Isotope Measurements of Two C-Rich Hydrated Interplanetary Dust Particles

Introduction: Chondritic-smooth IDPs (Interplanetary Dust Particles) are low porosity objects whose mineralogy is dominated by aqueous alteration products such as Mg-rich phyllosilicates (smectite and serpentine group) and Mg-Fe carbonate minerals. Their hydrated mineralogy combined with low atmospheric entry velocities have been used to infer an origin largely from asteroidal sources. Spectroscopic studies show that the types and abundance of organic matter in CS IDPs is similar to that in CP IDPs. Although CS IDPs show broad similarities to primitive carbonaceous chondrites, only a few particles have been directly linked to specific meteorite groups such as CM and CI chondrites based on the presence of diagnostic minerals. Many CS IDPs however, have carbon contents that greatly exceed that of known meteorite groups suggesting that they either may derive from comets or represent samples of more primitive parent bodies than do meteorites. It is now recognized that many large, dark primitive asteroids in the outer main belt, as well as some trans-Neptunian objects, show spectroscopic evidence for aqueous alteration products on their surfaces. Some CS IDPs exhibit large bulk D enrichments similar to those observed in the cometary CP IDPs. While hydrated minerals in comets have not been unambiguously identified to date, the presence of the smectite group mineral nontronite has been inferred from infrared spectra obtained from the ejecta from comet 9P/Tempel 1 during the Deep Impact mission. Recent observations of low temperature sulfide minerals in Stardust mission samples suggest that limited aqueous activity occurred on comet Wild-2. All of these observations, taken together, suggest that the high-carbon hydrated IDPs are abundant and important samples of primitive solar system objects not represented in meteorite collections. Oxygen isotopic compositions of chondrites reflect mixing between a 16O-rich reservoir and a 17O,18O-rich reservoir produced via mass-independent fractionation. The composition of the 16O-rich reservoir is well constrained but material representing the 17O,18O-rich end-member is rare. Self-shielding models predict that cometary water, presumed to represent this reservoir, should be enriched in 17O and 18O by greater than 200 per mille. The high-carbon hydrated IDPs may be among the best materials available to search for preserved "cometary" H2O signatures. In order to better understand the origin and evolution of these particles, we have obtained 10 hydrated interplanetary dust particles for coordinated mineralogical, isotopic and organic analyses. We have previously reported the results of mineralogical and O isotopic measurements of two hydrated IDPs; here we present results of O isotopic measurements of three additional IDPs. Samples and Methods: Three interplanetary dust particles (L2079C35, L2083D46 and L2083E46) were embedded in S and partially ultramicrotomed into approximately 70 nanometer sections for analysis via transmission electron microscopy (TEM). The remainders of the unsliced particles were removed from S and pressed into high purity Au foil that was cleaned with HF acid and annealed at 800 degrees Centigrade. The pressed IDPs were analyzed via electron microprobe analysis (EPMA) for quantitative bulk chemical analysis. After EPMA analysis, the IDPs were subjected to precision O isotope analysis with the UCLA Cameca IMS-1270 ion probe. A 20 kiloelectronvolt, 0.5 nanoangstrom Cs+ primary beam of approximately 15 micrometers diameter was used for each measurement. Small particles of San Carlos olivine and Burma spinel were pressed into the Au foil for use as standards to correct for instrumental mass fractionation. The detection system was configured for multicollection, with 16O measured on a Faraday cup, and 17O and 18O measured on electron multipliers (EMs). Individual analyses consisted of 15 cycles of 10 seconds per cycle. Additionally, two microtome thin sections were measured for H isotopic compositions with the JSC NanoSIMS 50L ion probe. An 8 picoangstrom, 16 kiloelectronvolt Cs plus primary beam was used. Measurements consisted of H, C, 12C, 16O, and 18O collected with EMs in multicollection. Terrestrial biotite and kerogen were used for isotopic standards. A significant challenge in O isotope measurement of hydrated minerals is the interference from 16OH at mass 17O. We ensured that the 17O and 16OH peaks were fully resolved by using a mass resolution of greater than 7000 and by careful analyses of San Carlos olivine, Burma spinel and chlorite hydrated mineral standards. The hydride was further suppressed with a cold finger attached to an LN2 dewar to trap volatiles in the sample chamber. All sputtered ions were counted (i.e. presputtering was not used); after applying background, yield and deadtime corrections, we performed a change-point analysis on our data via R in order to determine when the sample reached sputtering equilibrium; data points collected prior to the change point were excluded. Change-point analysis was also used to determine whether the IDP had completely sputtered. Results: Mineralogy. IDPs C35 and E46 exhibited hydrated mineralogies, Fe-Ni sulfide grains, nanoglobules and occasional enstatite grains distributed throughout a fine-grained Mg-Fe saponite matrix. C35 also contained breunnerite (Mg,Fe)CO3; solar flare tracks were observed in enstatite, indicating minimal atmospheric entry heating. The mineralogy of D46 is dominated by a large FeS grain with a minor component of adhering silicate material. D46 was strongly heated during atmorpheric entry as evidenced by a well-developed magnetite rim. EPMA analyses show that both C35 and E46 have high carbon contents of 20 weight percentage (approximately 6X CI). D46 contains approximately 6 wt.weight percentage C. A significant amount of the carbon is present as carbon nanoglobules. Results: Hydrogen isotopes: Although the bulk delta D values of both sections of L2079C35 were within error of SMOW (minus 33 plus or minus 19 per mille, 1 plus or minus 14 per mille 1 sigma), several delta D-rich hotspots were also identified, reaching 2000 per mille. As shown in Fig. 1, these hotspots are clearly associated with discrete carbonaceous inclusions that are akin to nanoglobules found in many meteorites and other IDPs. Oxygen Isotopes. Results of the oxygen isotope measurements are shown in Figure 1. The oxygen isotope composition for L2079C35 was delta 18O equals plus11.6 plus or minus 1.9per mille, delta 17O equals plus 7.9 plus or minus 1.9per mille (2 standard errors). The oxygen isotope composition for L2083D46 was delta 18O equals minus 8.1 plus or minus 1.9 per mille, delta 17O equals minus 6.4 plus or minus 3.1 per mille (2 standard errors). The oxygen isotope composition for L2083E46 was delta 18O equals plus 12.0 plus or minus 1.9 per mille, delta 17O equals plus 9.2 plus or minus 2.0 per mille (2 standard errors). Discussion: Despite mineralogical similarities to highly aqueously altered carbonaceous chondrites, the hydrated IDPs we analyzed have oxygen isotopic compositions that are distinct from matrix materials in the CI, CM, and CR chondrites. The IDPs plot along the Young-Russell line, with delta 17O values for C35 and E46 suggestive of interaction with a 16O-poor reservoir. However, we have thus far not observed evidence of extreme 16O-poor reservoirs expected from self-shielding models and observed in Acfer 094 simplectite. The high carbon contents of the IDPs also set them apart from known meteoritic samples. The lack of atmospheric entry heating effects are consistent with low encounter velocities and suggest either an asteroidal source, or a low inclination, low eccentricity cometary origin. Conclusions: The unusual oxygen isotopic compositions, high carbon contents, and the abundance of Drich nanoglobules, together, suggest that the high-carbon, hydrated IDPs are derived from a primitive source that is not yet represented in meteorite collections.

Snead, C. J.↗