Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

ON THE EFFECTIVENESS OF LLMS IN UNIT TEST GENERATION FOR STRUCTURED TEXT PROGRAMS

The reliability of industrial automation systems heavily depends on the correctness of Programmable Logic Controller (PLC) programs, which are often written in Structured Text (ST). While Large Language Models (LLMs) have shown promise in automating test generation for mainstream programming languages, their effectiveness for the syntactically strict ST language remains underexplored. This thesis presents a systematic empirical evaluation of three state-of-the-art LLMs—GPT-4o, Gemini 2.5 Pro, and Claude Sonnet 4.5—for generating ST unit tests. We examine three prompting strategies: Natural Language (NL), Code Language (CL), and Chain-of-Thought (CoT), across a curated set of 11 ST function blocks. The quality of the generated tests is assessed using Compilation Success Rate (CSR), Statement Coverage (SC), and Branch Coverage (BC). In the zero-shot setting, Claude Sonnet 4.5 achieves the highest CSR, while Gemini 2.5 Pro consistently delivers the best statement and branch coverage, particularly under CL prompts. By incorporating a one-shot CL prompt, all models exhibit substantial improvements—most notably GPT-4o, whose CSR increases from 45.45% to 90.91%, with substantial gains in both SC and BC. To further contextualize these findings, we compare GPT-4o’s one-shot results with PLCAutoTester, a state-ofthe- art ST unit test generation tool, on an additional benchmark dataset. While LLMgenerated tests approach competitive coverage levels, PLCAutoTester maintains significantly higher and more stable coverage across programs. This study provides the first comprehensive benchmark of modern LLMs for ST unit testing, highlighting their strengths, limitations, and improvements through one-shot prompting, and positioning their performance relative to specialized automated testing tools in industrial automation.

42 ENGINEERING↗

Utah FORGE: RESMAN Well 16A(78)-32 and 16B(78)-32 Stimulation and Circulation Tracer Test Results - 2024

This dataset contains tracer test results from stimulation and circulation experiments conducted on the Utah FORGE wells 16A(78)-32 and 16B(78)-32 during 2024. The data was collected by RESMAN Energy Technology and includes detailed tracer analysis from flowback, short- and extended-duration circulation tests, and reinjection sampling. Sampling included analysis of tracers during different stages of testing in April, August, and September 2024. The dataset is accompanied by an interpretation report and contains time-series tracer concentration data with identification of test phases and sampling conditions. It includes results for flowback from well 16A, commingling effects with water from well 16B, tracer data from short and extended circulation tests, and reinjection tracer corrections for the August/September test. Users should be aware that proprietary tracer methodologies were applied, and they should consult the interpretation report for insights into experimental procedures and data contextualization.

15 GEOTHERMAL ENERGY↗

Support of the Massachusetts — NREL Wind Technology Testing Center (Cooperative Research and Development Final Report)

Under the shared-resources CRADA agreement, NREL will collaborate with the Massachusetts Technology Park Corporation, d/b/a Massachusetts Technology Collaborative (MTC), in its efforts to design, construct, and operate the Massachusetts-NREL Wind Technology Testing Center (WTTC), which is an advanced blade testing facility capable of testing blades up to at least 70 meters in length. The WTTC building will be owned and the facility operated by the MTC. In the CRADA, NREL agrees to provide certain capital equipment and certain NREL employees at the WTTC facility for training, commissioning, and continued technical assistance. In addition, NREL will provide one or more Laboratory staff to serve on any WTTC advisory committee, a no-cost license of the NREL blade-resonance fatigue testing technology (NREL Testing IP) and training to MA staff at the NREL blade test facilities in Colorado. MTC will provide all other resources necessary to design, construct, and operate the WTTC.

17 WIND ENERGY↗

Nonlinear Impact-Echo Test for Quantitative Evaluation of ASR Damage in Concrete

Nonlinear acoustic methods demonstrate high sensitivity for concrete damage evaluation. Among these methods, nonlinear resonance acoustic methods have been widely used in laboratory tests on small scale test samples. In this study, a nonlinear impact-echo (IE) method for concrete damage evaluation was introduced, in which the IE frequency shift was measured at different impact force levels. The nonlinear IE test and the nonlinear impact resonance acoustic spectroscopy (NIRAS) test share similarities in the experimental setup and analysis method. However, the nonlinear IE test excites a local thickness resonance mode of a member instead of the global resonance vibration. Therefore, the analyzed mode is unaffected by member boundary conditions and is applicable to large concrete structural members. To identify the fundamental IE frequencies, multiple impacts were applied along the members. Once the fundamental IE frequencies were determined, the effectiveness of the nonlinear IE method was evaluated by testing seven concrete beam specimens with varying levels of alkali-silica reaction (ASR) damage. In conclusion, the nonlinear IE test demonstrates high sensitivity to concrete damage and allows for quantitative assessment of the damage state of concrete without a baseline measurement.

36 MATERIALS SCIENCE↗

The distinct conditions of atmospheric and underground nuclear tests revealed by Zn isotopic compositions of nuclear debris samples

We analyzed the Zn isotopic compositions of nuclear debris samples from atmospheric and underground nuclear tests. Samples from the site of atmospheric tests exhibit a range of Zn isotopic fractionation (δ 66 Zn JMC-Lyon = 0.23–0.86 ‰) while samples from underground tests exhibit Zn isotopic compositions with minimal variation among samples and from terrestrial igneous rock standards (δ 66 ZnJMC-Lyon = 0.28–0.39 ‰). In conclusion, the larger range of δ 66 Zn JMC-Lyon observed in atmospheric test samples relative to underground test samples is likely the result of the open system characteristics of atmospheric nuclear tests and the closed system characteristics of underground nuclear tests.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Robust foil regenerator flow loss and heat transfer tests under oscillating flow condition

A regenerator works as an energy storage component in a Stirling engine. Thus, it is one of the most critical components that makes the Stirling engine highly efficient. Traditionally, the regenerators are made of wire media such as woven screens and random fibers. These wire regenerators experience considerably high flow losses through the regenerator due to the flow separation and the resulting vortices. The high flow losses associated with the flow separation and vortices result in a lower engine efficiency. This research is to test a new robust foil regenerator to investigate its feasibility for free-piston Stirling engine applications. The robust foil regenerator is configured with parallel flow channels and stiffening ribs. Comparing to complex flows patterns in woven screen and random fiber regenerators, the flows in the parallel plates are simple and the flow losses are considerably small, and the heat transfer coefficient is also relatively small. To test the regenerator experimentally, a regenerator test rig was manufactured. To verify the accuracy of the test rig, a woven screen regenerator was made and tested prior to the robust foil regenerator test. The friction factor correlation of the woven screen regenerator shows a good agreement with the published regenerator correlations. The robust foil regenerator tests were conducted under the oscillating flow condition with different Reynolds numbers. The flow losses were measured with dynamic pressure transducers and the friction coefficient was derived from measured pressure drop. The measured temperature difference over the regenerator was used to calculate the heat transfer coefficient and Nusselt number. The figure of merit with two methods of NPH/NTU ratio and j/f ratio was calculated to evaluate the suitability of the robust foil regenerator. The results show that the robust foil regenerator has considerably higher figure of merit and therefore, better performance than other types of regenerator.

42 ENGINEERING↗

First ITER CS module test results

The ITER Central Solenoid (CS) is under fabrication by the US ITER organization and its subcontractors. US ITER will supply seven modules to ITER IO, six of which will be assembled in a stack that forms the ITER Central Solenoid, with one as a spare. The first module fabrication has been completed by General Atomics (GA) at their facility and has begun testing including high voltage testing, Paschen testing in the vacuum and then testing at 4.5 K and up to 40 kA in order to demonstrate compliance of the coil to ITER requirements. In the paper we present the Test Plan and results of the CS Module performance tests, especially at 40 kA current. Herein, AC losses, joint resistances and hydraulic characteristics of the coil are all measured. Displacements of the coil height and hoop strain of the CS Module are also measured to verify structural and mechanical characteristics of the coil along with cooldown shrinkage of the coil. This information is used for verification of the stack behavior of CS in ITER operation. The test results and preliminary analyses results are presented, compared to expectations, and discussed. All measured parameters suggest that the CS module will perform well in ITER machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fission product distribution in irradiated safety-tested and as-irradiated AGR-2 TRISO particles

In this work, two tristructural isotropic (TRISO)-coated nuclear fuel particles were examined by electron probe microanalysis (EPMA) as part of the Advanced Gas Reactor program. The compacts’ average irradiation temperatures ranged from approximately 1260 to 1290 °C. One particle was examined in the as-irradiated condition, while the other was subject to 1600 °C post-irradiation safety testing. This study was undertaken to test a newly-developed EPMA technique to determine fission product masses in TRISO particles on a layer-by-layer basis, and to compare fission product distributions between an as-irradiated and safety-tested particle. Fission product concentration profiles were collected along two radii in each particle, with measured concentrations used to compute the fission product mass in each TRISO particle layer. These measured masses were then compared to those predicted from ORIGEN modeling calculations. Data collected from these measurements show that for these two particles, masses determined via EPMA were within ± 20% of the calculated masses for the rare-earth elements, Mo, Zr, Cs, I, and Pd. Elements that tend to be less homogeneously distributed include Sr, Te, Eu, Ag, and possibly Ba. Measured Ag masses differed by more than 40% from the calculated mass. Lanthanides other than Eu remain primarily within the fuel kernel in the as-irradiated particle but in the safety-tested particle these element masses were divided approximately equally between the kernel and kernel periphery. In both particles, the majority of Sr and Eu accumulated in the carbon-rich kernel periphery, although in the safety-tested particle, Sr and Eu accumulated farther from the fuel kernel than occurred with irradiation alone. A greater mass fraction of mobile elements, such as Cs and I accumulated in the buffer and IPyC in the safety-tested particle as compared to the as-irradiated particle. When fully developed and tested, this mass balance approach to TRISO particle analysis has the potential to provide insight into fuel behavior.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of automated stability testing in machining through closed-loop control and Bayesian machine learning

Here, this paper describes a system for automated identification of the optimal stable cutting parameters in milling through Bayesian machine learning and closed-loop control. The closed-loop control system consists of a process monitoring architecture, an analysis framework, and a feedback mechanism. The analysis framework consists of a Bayesian machine learning algorithm that learns a stability map given test results. The learned stability map is used to select parameters for stability testing using an expected improvement in the material removal rate criterion. The test parameters are communicated to the machine controller to complete the test cut through a feedback mechanism. The test cuts were monitored using an audio signal; the stability of the test cut was determined by analyzing the frequency content of the audio signal. The test result was fed back to the Bayesian learning algorithm to complete the loop. Experimental results demonstrate that the system can identify the optimal stable parameters without information about the cutting force model or the structural dynamics. The system provides a low-cost method for optimal stable parameter identification in an industrial environment.

Chatter↗

Normative Ranges for, and Interrater Reliability of, Rotational Vestibular and Balance Tests in U.S. Military Service Members and Veterans

Purpose: The objectives of this study were to (a) describe normative ranges—expressed as reference intervals (RIs)—for vestibular and balance function tests in a cohort of Service Members and Veterans (SMVs) and (b) to describe the interrater reliability of these tests. Method: As part of the Defense and Veterans Brain Injury Center (DVBIC)/Traumatic Brain Injury Center of Excellence 15-year Longitudinal Traumatic Brain Injury (TBI) Study, participants completed the following: vestibulo-ocular reflex suppression, visual-vestibular enhancement, subjective visual vertical, subjective visual horizontal, sinusoidal harmonic acceleration, the computerized rotational head impulse test (crHIT), and the sensory organization test. RIs were calculated using nonparametric methods and interrater reliability was assessed using intraclass correlation coefficients between three audiologists who independently reviewed and cleaned the data. Results: Reference populations for each outcome measure comprised 40 to 72 individuals, 19 to 61 years of age, who served either as noninjured controls (NIC) or injured controls (IC) in the 15-year study; none had a history of TBI or blast exposure. A subset of 15 SMVs from the NIC, IC, and TBI groups were included in the interrater reliability calculations. RIs are reported for 27 outcome measures from the seven rotational vestibular and balance tests. Interrater reliability was considered excellent for all tests except the crHIT, which was found to have good interrater reliability. Conclusion: This study provides clinicians and scientists with important information regarding normative ranges and interrater reliability for rotational vestibular and balance tests in SMVs.

Audiology & Speech-Language Pathology↗

Test methodology for validation of multi-frequency models of renewable energy generators using small-signal perturbations

Providing trustworthy and accurate multi-frequency (or harmonic) models for renewable energy generators (REG) is an ongoing challenge for harmonic studies. There have been effective attempts to propose and design a test device to validate the harmonic models, mainly based on shunt current perturbations. However, using additional devices for perturbations is costly for converter-based test sites. This paper provides the test specifications to extend the application of the grid emulators for voltage perturbations and appropriate harmonic model validation. Besides, the effects of the sequence couplings, initial emissions, and power set-points on the test results have been overlooked in the literature. Considering these effects, this paper proposes a generic test methodology to obtain more accurate models in the sequence domain. The experimental verification of the proposed methodology is demonstrated using a 7 MVA grid emulator for testing of a 2 MVA photo-voltaic converter and a 2 MVA Type 3 wind turbine. This way, the test challenges, specifications, and recommendations are presented using the MW-scale experiments on different REGs. Furthermore, the effects of sequence couplings and initial emissions on the calculation results are investigated and compared. The proposed methodology is applicable for harmonic model validation as well as empirical modelling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing Separate Effects Transient Test Experiments Using an Out-of-Pile Flowing Water Loop

In 2017 the Transient Reactor Test Facility was restarted after being placed in a standby state since 1994. This Test Reactor’s restart has since enabled the progressive development of new nuclear technologies within the U.S. that were previously required to outsource to other countries. While the reactor’s restart was a large feat worthy of recognition, the experimental use of its characteristics has required the further development of in-pile experimental infrastructure sufficient to support programmatic needs. This hardware have taken the form of capsule designs (compact and elongated) as well as loop concepts representing the phenomena of interest for a subset of separate effects tests desire for each respective testing campaign. The Transient Testing Program has a large-integrated effort that aligns with the U.S. Department of Energy’s current needs. This study compliments those programmatic elements by developing, fabricating and demonstrating a full-scale flowing water loop in an out-of-pile environment. The goal of this effort is to develop a pragmatic understanding of the engineering capabilities and limitations associated with geometric form-factors, metering technology, and controls logic under representative thermal hydraulic conditions that would be experienced within the TREAT reactor during an in-pile reactivity initiated accident test. The outcomes of this study result in an evaluation of the conceptual design of a comprehensive flowing water loop including objective figures of merit (FoMs) for comparing unique instrumentation and the basis for their selection during operations. These efforts directly contribute to and are required for the further advancement of transient testing capabilities within the U.S.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fermilab Cryogenic Test Facilities

Fermi National Accelerator Laboratory (Fermilab) has multiple cryogenic test facilities, undertaking testing of superconducting magnets, Superconducting Radio Frequency (SRF) cavities, SRF cryomodules and other helium cryogenic components. The test areas within Fermilab include: Meson Cryogenic Test facility (Meson), Industrial Building 1 (IB-1), Heavy Assembly Building/Illinois Accelerator Research Center (HAB/IARC), New Muon Lab, (NML) and the Cryomodule Test Facility (CMTF). Meson and HAB/IARC utilize repurposed Tevatron era reciprocating engine based cryogenic refrigerator systems, whereas CMTF and IB-1 utilize gas bearing turbine based coldboxes. Each of these test areas support the various Fermilab projects and collaborations including the Linear Coherent Light Source II (LCLS-II), Proton Improvement Plan II (PIP-II), High Luminosity Large Hadron Collider (HL-LHC), and Mu2e. This paper outlines the diverse and extensive cryogenic test capabilities within Fermilab.

43 PARTICLE ACCELERATORS↗

Effect of Temperature on Thrombogenicity Testing of Biomaterials in an In Vitro Dynamic Flow Loop System

To develop and standardize a reliable in vitro dynamic thrombogenicity test protocol, the key test parameters that could impact thrombus formation need to be investigated and understood. In this study, we evaluated the effect of temperature on the thrombogenic responses (thrombus surface coverage, thrombus weight, and platelet count reduction) of various materials using an in vitro blood flow loop test system. Whole blood from live sheep and cow donors was used to assess four materials with varying thrombogenic potentials: negative-control polytetrafluoroethylene (PTFE), positive-control latex, silicone, and high-density polyethylene (HDPE). Blood, heparinized to a donor-specific concentration, was recirculated through a polyvinyl chloride tubing loop containing the test material at room temperature (22–24°C) for 1 hour, or at 37°C for 1 or 2 hours. The flow loop system could effectively differentiate a thrombogenic material (latex) from the other materials for both test temperatures and blood species ( p < 0.05). However, compared with 37°C, testing at room temperature appeared to have slightly better sensitivity in differentiating silicone (intermediate thrombogenic potential) from the relatively thromboresistant materials (PTFE and HDPE, p < 0.05). These data suggest that testing at room temperature may be a viable option for dynamic thrombogenicity assessment of biomaterials and medical devices.

Engineering↗

Novel Probes Project: Tests of gravity on astrophysical scales

The Novel Probes Project, an initiative to advance the field of astrophysical tests of the dark sector by creating a forum that connects observers and theorists, is introduced. This review focuses on tests of gravity and is intended to be of use primarily to observers, as well as theorists with an interest in the development of experimental tests. It is twinned with a separate upcoming review on dark matter self-interactions. The review focuses on astrophysical tests of gravity in the weak-field regime, ranging from stars to quasilinear cosmological scales. This regime is complementary to both strong-field tests of gravity and background and linear probes in cosmology. In particular, the nonlinear screening mechanisms that are an integral part of viable modified-gravity models lead to characteristic signatures, specifically on astrophysical scales. The potential of these probes is not limited by cosmic variance but comes with the challenge of building robust theoretical models of the nonlinear dynamics of stars, galaxies, and large-scale structure. The groundwork is laid for a thorough exploration of the weak-field, nonlinear regime, with an eye to using the current and next generation of observations for tests of gravity. The scene is set by showing how gravitational theories beyond general relativity are expected to behave, focusing primarily on screening mechanisms. Analytic and numerical techniques for exploring the relevant astrophysical regime are described, as are the pertinent observational signals. With these in hand a range of astrophysical tests of gravity are presented, and prospects for future measurements and theoretical developments are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Test Results of the First Pre-Series Quadrupole Magnets for the LHC Hi-Lumi Upgrade

The future high luminosity (Hi-Lumi) upgrade of the Large Hadron Collider (LHC) at CERN will include eight (plus two spares) 10.2 m-long Cryo-assemblies which will be components of the triplets for two LHC insertion regions. Each cold mass in the Cryo-assemblies will consist of two 4.2 m-long Nb 3 Sn high gradient quadrupole magnets, designated MQXFA, with aperture 150 mm and operating gradient 132.2 T/m, for a total of twenty magnets. Before assembling and testing the final cold masses at Fermilab, the component quadrupoles are being tested first at the vertical superconducting magnet test facility of the Superconducting Magnet Division (SMD) at Brookhaven National Laboratory (BNL), in superfluid He at 1.9 K and up to 18.0 kA, in accordance with operational requirements of the LHC. The tests of the first two full-length prototype quadrupole magnets MQXFAP1 and MQXFAP2 at BNL have been reported previously. The first two pre-series magnets, the first two that will be used in the LHC, have also now been tested. This paper reports on the quench test and training results of these two magnets. The test results of these magnets will be important for validating the final MQXFA design for operational magnets.

43 PARTICLE ACCELERATORS↗

Challenges and Lessons Learned From Fabrication, Testing, and Analysis of Eight MQXFA Low Beta Quadrupole Magnets for HL-LHC

By the end of October 2022, the US HL-LHC Accelerator Upgrade Project (AUP) had completed fabrication of ten MQXFA magnets and tested eight of them. The MQXFA magnets are the low-beta quadrupole magnets to be used in the Q1 and Q3 Inner Triplet elements of the High Luminosity LHC. This AUP effort is shared by BNL, Fermilab, and LBNL, with strand verification tests at NHMFL. An important step of the AUP QA plan is the testing of MQXFA magnets in a vertical cryostat at BNL. The acceptance criteria that could be tested at BNL were all met by the first four production magnets (MQXFA03-MQXFA06). Subsequently, two magnets (MQXFA07 and MQXFA08) did not meet some of the criteria and were disassembled. Furthermore, lessons learned during the disassembly of MQXFA07 caused a revision to the assembly specifications that were used for MQXFA10 and subsequent magnets. In this article, we present a summary of 1) the fabrication and test data for all the MQXFA magnets; 2) the analysis of MQXFA07/A08 test results with characterization of the limiting mechanism; 3) the outcome of the investigation, including the lessons learned during MQXFA07 disassembly; and 4) the finite element analysis correlating observations with test performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of the Top Plate and Anticryostat for High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (Fermilab) is currently constructing a new High Field Vertical Magnet Test Facility (HFVMTF) designed for testing High Temperature Superconducting (HTS) cables under high magnetic fields. This facility is expected to offer capabilities similar to those of EDIPO at PSI and FRESCA2 at CERN. The background magnetic field of 15 T will be generated by a magnet supplied by Lawrence Berkeley National Laboratory. The primary function of HFVMTF will be to serve as a superconducting cable test facility, facilitating tests under high magnetic fields and a broad spectrum of cryogenic temperatures. Additionally, the facility will be utilized for testing high-field superconducting magnet models and demonstrators, including hybrid magnets, developed by the US Magnet Development Program (MDP). This paper provides a comprehensive description of the current status of two pivotal components of the facility: the Top/Lambda Plates Assembly and the Anticryostat for the Test Sample Holder. The latter will serve as a principal interface component connecting cable test samples with the facility's cryostat.

43 PARTICLE ACCELERATORS↗