Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Iodine Removal in the DFLAW Flow-Sheet

In support of the WTP project, off-gas system and regulatory testing has been conducted previously on the DM1200 pilot melter equipped with a prototypical off-gas system installed at The Catholic University of America’s Vitreous State Laboratory (VSL). During the regulatory tests, an AC-S test bed filled with Kombisorb BAT 37 was included in the prototypical off-gas system and evaluated for response to HLW and LAW exhaust streams. Offline testing and small-scale testing of that media were also conducted. Testing demonstrated that a temperature rise occurred in the activated carbon media when water vapor was first introduced to virgin Kombisorb BAT 37, in response to high nitrogen oxide concentrations, and in response to the presence of organic compounds. Conditioning of the test bed by gradually increasing the NOx concentration prior to the introduction of organics was found to be an important operational strategy for preventing larger temperature excursions. However, no mercury was present in the exhaust stream during DM1200 testing and therefore comparable test data for mercury removal efficiency or temperature response of the carbon media in the presence of mercury were not collected in the DM1200 tests. In view of the need for data on mercury removal performance, BNI contracted with Atkins and the VSL to install and operate a suitable test system at VSL to collect the required data. That testing was designed to assess the performance of Kombisorb BAT-37 and the guard bed material, Sofnolime RG, for simulated melter exhaust streams that contain the highest concentrations of mercury, nitrogen oxides, acid gases, and organic compounds expected in WTP LAW melter exhaust. During shakedown testing with the new system, however, it became evident that a number of issues with Sofnolime RG as the guard bed material would render it unsuitable for this application. BNI subsequently determined that the guard bed was redundant for removal of acid gases since they could be adequately removed by the SBS and WESP. However, since the guard bed material was also credited with significant iodine removal , there was a need for a replacement material that would adequately perform that role. BNI identified several candidate media but performance data in gas compositions that are representative of the WTP LAW off-gas were not available. Accordingly, there was a need to test and evaluate the performance of these candidate media prior to performing the originally-planned tests. To that end, small scale tests were conducted to assess the performance of various adsorbents in simulated melter exhaust streams that contain mercury, iodine, nitrogen oxides, acid gases, and acetonitrile, which are expected to be present in WTP LAW melter exhaust.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of Data Libraries for IAEA Nuclear Security Assessment Methodologies (NUSAM) [section 5.4]

Data libraries are essential for the characterization of the facility and provide the documented input which enables the facility assessment results and subsequent conclusions. Data Libraries are historical, verifiable, quantified, and applicable collections of testing data on different types of barriers, sensors, cameras, procedures, and/or personnel. Data libraries are developed and maintained as part of any assessment program or process. Data is collected during the initial stages of facility characterization to aid in the model and/or simulation development process. Data library values may also be developed through the use of state testing centers and/or site resources by testing different types of barriers, sensors, cameras, procedures, and/or personnel. If no data exists, subject matter expert opinion and manufacturer's specifications/ testing values can be the basis for initially assigning values, but are generally less reliable and lack appropriate confidence measures. The use of existing data libraries that have been developed by a state testing organization reduces the assessment costs by establishing standard delay, detection and assessment values for use by multiple sites or facilities where common barriers and alarms systems exist.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Climate Science for a Sustainable Energy Future Test Bed and Data Infrastructure Final Report

The collaborative Climate Science for a Sustainable Energy Future (CSSEF) project started in July 2011 with the goal of accelerating the development of climate model components (i.e., atmosphere, ocean and sea ice, and land surface) and enhancing their predictive capabilities while incorporating uncertainty quantification (UQ). This effort required accessing and converting observational data sets into specialized model testing and verification data sets and building a model development test bed, where model components and sub-models can be rapidly evaluated. CSSEF’s prototype test bed demonstrated, how an integrated testbed could eliminate tedious activities associated with model development and evaluation, by providing the capability to constantly compare model output—where scientists store, acquire, reformat, regrid, and analyze data sets one-by-one—to observational measurements in a controlled test bed.

54 ENVIRONMENTAL SCIENCES↗

Data of High-Temperature Dynamic LCM Testing Setup

Data from high temperature dynamic sealing tests for various fracture widths, at various temperatures (degrees F), with 5 wt.% bentonite-based mud containing various material fiber contents, at 100 to 400 psi differential pressure. Data from pressure test and evaluation of the dynamic lost circulation materials (LCM) testing unit to reflect the condition of open and sealed fracture using fracture width of 1000 microns at 120 degrees F. Links to two papers based on the data - "Loss circulation prevention in geothermal drilling by shape memory polymer" which was published in Geothermics 89 (2021) 101943) as well as "Evaluating sealability of blended smart polymer and fiber additive for geothermal drilling with the effect of fracture opening size", published in the Journal of Petroleum Science and Engineering 206 (2021) 108998.

15 GEOTHERMAL ENERGY↗

Deep in Data: Empirical Data Based Software Accuracy Testing Using the Building America Field Data Repository

This paper describes progress toward developing a usable, standardized, empirical data-based software accuracy test suite using home energy consumption and building description data. Empirical data collected from around the United States have been translated into a uniform Home Performance Extensible Markup Language format that may enable software developers to create translators to their input schemes for efficient access to the data. This could allow for modeling many homes expediently, and thus implementing software accuracy test cases by applying the translated data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset of mechanically induced thermal runaway measurement and severity level on Li-ion batteries

The deployment of Li-ion batteries covers a wide range of energy storage applications, from mobile phones, e-bikes, electric vehicles (EV) and stationary energy storage systems. However, safety issue such as thermal runaway is always one of the most important concerns to prevent Li-ion batteries from further market penetration. A standardized single-side indentation test protocol was developed to mechanically induce an internal short-circuit. The cell voltage, compressive load, indenter stroke, and temperature at the indentation point are measured in time series. The test data of each cell, along with cell parameters such as dimensions, mass, chemistry, state of charge (SOC), capacity, are integrated together to calculate a thermal runaway severity score from 0 to100. Complete data collection process including the original measured record, test method, severity score calculation scheme is presented in this article. The thermal runaway severity analysis and the more than 100 tested Li-ion battery records provide a good data source for further comparison and ranking of thermal runaway risks.

25 ENERGY STORAGE↗

Optimal SCR Control Using Data-Driven Models

We present an optimal control solution for the urea injection for a heavy-duty diesel (HDD) selective catalytic reduction (SCR). The approach taken here is useful beyond SCR and could be applied to any system where a control strategy is desired and input-output data is available. For example, the strategy could also be used for the diesel oxidation catalyst (DOC) system. In this paper, we identify and validate a one-step ahead Kalman state-space estimator for downstream NOx using the bench reactor data of an SCR core sample. The test data was acquired using a 2010 Cummins 6.7L ISB production engine with a 2010 Cummins production aftertreatment system. We used a surrogate HDD federal test procedure (FTP), developed at Michigan Technological University (MTU), which simulates the representative transients of the standard FTP cycle, but has less engine speed/load points. The identified state-space model is then used to develop a tunable cost function that simultaneously minimizes NOx emissions and urea usage. The cost function is quadratic and univariate, thus the minimum can be computed analytically. We show the performance of the closed-loop controller in using a reduced-order discrete SCR simulator developed at MTU. Our experiments with the surrogate HDD-FTP data show that the strategy developed in this paper can be used to identify performance bounds for urea dose controllers.

diesel, emmissions, control, environment, modeling↗

Using Machine Learning to Create Turbine Performance Models (Presentation)

Wind turbine power output is known to be a strong function of wind speed, but is also affected by turbulence and shear. In this work, new aerostructural simulations of a generic 1.5 MW turbine are used to explore atmospheric influences on power output. Most significant is the hub height wind speed, followed by hub height turbulence intensity and then wind speed shear across the rotor disk. These simulation data are used to train regression trees that predict the turbine response for any combination of wind speed, turbulence intensity, and wind shear that might be expected at a turbine site. For a randomly selected atmospheric condition, the accuracy of the regression tree power predictions is three times higher than that of the traditional power curve methodology. The regression tree method can also be applied to turbine test data and used to predict turbine performance at a new site. No new data is required in comparison to the data that are usually collected for a wind resource assessment. Implementing the method requires turbine manufacturers to create a turbine regression tree model from test site data. Such an approach could significantly reduce bias in power predictions that arise because of different turbulence and shear at the new site, compared to the test site.

17 WIND ENERGY↗

Building America Case Study: Predicting Envelope Leakage in Attached Dwellings (Fact Sheet)

'The cost for blower testing is high, because it is labor intensive, and it may disrupt occupants in multiple units. This high cost and disruption deters program participants, and dissuades them from pursuing energy improvements that would trigger air leakage testing, such as improvements to the building envelope.' This statement found in a 2012 report by Heschong Mahone Group emphasizes the importance of reducing the cost and complexity of blower testing in multifamily buildings. Energy efficiency opportunities are being bypassed. The cost of single blower testing is on the order of $300. The cost for guarded blower door testing, the more appropriate test for assessing energy savings opportunities, could easily be six times that and that's only if you have the equipment and simultaneous access to multiple apartments. Thus, the proper test is simply not performed. The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multifamily Envelope Leakage Model

The objective of the 2013 research project was to develop the model for predicting fully guarded test results (FGT), using unguarded test data and specific building features of apartment units. The model developed has a coefficient of determination R2 value of 0.53 with a root mean square error (RMSE) of 0.13. Both statistical metrics indicate that the model is relatively strong. When tested against data that was not included in the development of the model, prediction accuracy was within 19%, which is reasonable given that seasonal differences in blower door measurements can vary by as much as 25%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Platooning with ADAS (Advanced Driver-Assistance Systems) Control Integration and Assessment

Application of Cooperative Adaptive Cruise Control (CACC) to heavy duty trucks known as truck platooning has shown fuel economy improvements on the test track under ideal driving conditions. However, limited test data is available to assess the truck platooning under real-world driving conditions. Under this Cummins-led project that was funded by the U.S. Department of Energy, truck platooning with CACC has been tested on a real-world interstate highway and the results of the project are reviewed in this report. At first, the real-world driving conditions were characterized using National Renewable Energy Laboratory (NREL) Fleet DNA database to define test factors, including route, terrain, and highway traffic. Afterward, both test track and on-highway testing guided by SAE J1321 procedures were conducted to assess truck platooning under controlled and real-world driving conditions. On-highway testing was done on a highway route in Indiana, consisting of low, medium, and high road grade segments. The highway test results of 2-truck and 3-truck platooning showed considerably reduced fuel savings compared to the controlled test track data, which mainly stems from the traffic or high-grade portions of the route. However, integration of Cummins powertrain and vehicle eco-driving features such as predictive cruise control and neutral coasting called ADEPT™ on the lead truck showed an improvement of fuel saving for the trucks in CACC operation. Furthermore, the importance of tire connectivity in efficient and safe operation of the trucks in platooning is characterized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fatigue and Creep-Fatigue Evaluation of Alloy 709 at 760 and 816°C

A significant research and development effort is underway to support the qualification of Alloy 709 as a Class A construction material in the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section III, Division 5, High Temperature Reactors. This initiative includes a comprehensive Alloy 709 code qualification plan aimed at generating extensive material testing data crucial for compiling the code case data package. The data package is essential in establishing material-specific design parameters for Alloy 709 to be used as Section III, Division 5 Class A construction material for fast reactors, molten salt reactors and gas-cooled reactors. An ASME Section III, Division 5 material code case requires the evaluation of mechanical properties from a minimum of three commercial heats, covering anticipated compositional ranges. A key part of the data package involves fatigue and creep-fatigue testing at elevated temperatures, needed for developing the fatigue design curves and the damage envelope of the creep-fatigue interaction diagram (D-diagram). This paper summarizes the strain-controlled fatigue testing on three commercial heats of Alloy 709 at 760 and 816°C with strain ranges between 0.25% and 3%. The fatigue failure data are used to generate a preliminary fatigue design curve. Additionally, the creep-fatigue testing results at 816°C with tensile hold times of 10, 30, and 60 minutes are presented in support of developing the D-diagram for Alloy 709.

Wang, Yanli↗

Systems and methods for real-time data processing and for emergency planning

Systems and methods are described herein for real-time data processing and for emergency planning. Scenario test data may be collected in real-time based on monitoring local or regional data to ascertain any anomaly phenomenon that may indicate an imminent danger or of concern. A computer-implemented method may include filtering a plurality of different test scenarios to identify a sub-set of test scenarios from the plurality of different test scenarios that may have similar behavior characteristics. A sub-set of test scenarios is provided to a trained neural network to identify one or more sub-set of test scenarios. The one or more identified sub-set of test scenarios may correspond to one or more anomaly test scenarios from the sub-set of test scenarios that is most likely to lead to an undesirable outcome. The neural network may be one of: a conventional neural network and a modular neural network.

Yilmaz, Alper↗

Systems and methods for real-time data processing and for emergency planning

Systems and methods are described herein for real-time data processing and for emergency planning. Scenario test data may be collected in real-time based on monitoring local or regional data to ascertain any anomaly phenomenon that may indicate an imminent danger or of concern. A computer-implemented method may include filtering a plurality of different test scenarios to identify a sub-set of test scenarios from the plurality of different test scenarios that may have similar behavior characteristics. A sub-set of test scenarios is provided to a trained neural network to identify one or more sub-set of test scenarios. The one or more identified sub-set of test scenarios may correspond to one or more anomaly test scenarios from the sub-set of test scenarios that is most likely to lead to an undesirable outcome. The neural network may be one of: a conventional neural network and a modular neural network.

97 MATHEMATICS AND COMPUTING↗

FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cast CF8C-Plus Stainless Steel for Turbocharger Applications

The purpose of this Cooperative Research and Development Agreement (CRADA) project is to provide the critical test data needed to qualify CF8C-Plus cast stainless steel for commercial production and use for turbocharger housings with upgraded performance and durability relative to standard commercial cast irons or stainless steels. The turbocharger technologies include, but are not limited to, heavy-duty highway diesel engines, and passenger vehicle diesel and gasoline engines. This CRADA provides additional critical high-temperature mechanical properties testing and data analysis needed to quality the new CF8C-Plus steels for turbocharger housing applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Deep in Data: Empirical Data Based Software Accuracy Testing Using the Building America Field Data Repository: Preprint

An opportunity is available for using home energy consumption and building description data to develop a standardized accuracy test for residential energy analysis tools. That is, to test the ability of uncalibrated simulations to match real utility bills. Empirical data collected from around the United States have been translated into a uniform Home Performance Extensible Markup Language format that may enable software developers to create translators to their input schemes for efficient access to the data. This may facilitate the possibility of modeling many homes expediently, and thus implementing software accuracy test cases by applying the translated data. This paper describes progress toward, and issues related to, developing a usable, standardized, empirical data-based software accuracy test suite.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling of Interaction Layer Growth Between U-Mo Particles and an Al Matrix

Interaction layer growth between U-Mo alloy fuel particles and Al in a dispersion fuel is a concern due to the volume expansion and other unfavorable irradiation behavior of the interaction product. To reduce interaction layer (IL) growth, a small amount of Si is added to the Al. As a result, IL growth is affected by the Si content in the Al matrix. In order to predict IL growth during fabrication and irradiation, empirical models were developed. For IL growth prediction during fabrication and any follow-on heating process before irradiation, out-of-pile heating test data were used to develop kinetic correlations. Two out-of-pile correlations, one for the pure Al matrix and the other for the Al matrix with Si addition, respectively, were developed, which are Arrhenius equations that include temperature and time. For IL growth predictions during irradiation, the out-of-pile correlations were modified to include a fission-rate term to consider fission enhanced diffusion, and multiplication factors to incorporate the Si addition effect and the effect of the Mo content. The in-pile correlation is applicable for a pure Al matrix and an Al matrix with the Si content up to 8 wt%, for fuel temperatures up to 200 degrees C, and for Mo content in the range of 6 – 10wt%. In order to cover these ranges, in-pile data were included in modeling from various tests, such as the US RERTR-4, -5, -6, -7 and -9 tests and Korea’s KOMO-4 test, that were designed to systematically examine the effects of the fission rate, temperature, Si content in Al matrix, and Mo content in U-Mo particles. A model converting the IL thickness to the IL volume fraction in the meat was also developed.

99 GENERAL AND MISCELLANEOUS↗