Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Laser-plasma debris from a rotating cryogenic-solid-Xe target

We investigate the characteristics of laser plasma debris that is responsible for damaging optics. The debris is composed of fast ions, neutral particles, and fragments, and originates from a solid Xe target on a rotating drum that we developed as an extreme ultraviolet (EUV) source. The ice fragments appear to be a problem most notably with solid Xe targets; however, we find that the damage induced by Xe ice fragments can be avoided by simply reducing the laser pulse energy. We find the number of fast neutral particles to be an order of magnitude less than the number of ions, and we clarify that the plasma debris is primarily composed of fast ions. In addition, we find that the number of fast ions having a few dozen keV of energy decreases when using the rotating target compared with the rest target. We attribute this to a gas curtain effect from the Xe gas localized at the rotating target surface. We estimate the sputtering rate of the Mo/Si mirror, which is caused primarily by the fast ions, to be 104 nm/1x10{sup 6} shots at 190 mm from the source plasma and at an 11.25 deg. angle from the incident laser beam. Up to the 1x10{sup 6} shots exposure, remarkable degradation of the mirror reflectivity is not observed though the sputtering damages the mirror. Mitigation of the ions by using gas and/or magnetic fields will further improve the mirror lifetime. By comparing with a liquid jet Xe target, we conclude that the sputtering rate per conversion efficiency when using the solid Xe targets on the rotating drum is the same as that when using the liquid Xe targets. The high conversion efficiency of 0.9% in the rotating drum solid Xe target makes this technique useful for developing laser plasma EUV sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Protein search for multiple targets on DNA

Protein-DNA interactions are crucial for all biological processes. One of the most important fundamental aspects of these interactions is the process of protein searching and recognizing specific binding sites on DNA. A large number of experimental and theoretical investigations have been devoted to uncovering the molecular description of these phenomena, but many aspects of the mechanisms of protein search for the targets on DNA remain not well understood. One of the most intriguing problems is the role of multiple targets in protein search dynamics. Using a recently developed theoretical framework we analyze this question in detail. Our method is based on a discrete-state stochastic approach that takes into account most relevant physical-chemical processes and leads to fully analytical description of all dynamic properties. Specifically, systems with two and three targets have been explicitly investigated. It is found that multiple targets in most cases accelerate the search in comparison with a single target situation. However, the acceleration is not always proportional to the number of targets. Surprisingly, there are even situations when it takes longer to find one of the multiple targets in comparison with the single target. It depends on the spatial position of the targets, distances between them, average scanning lengths of protein molecules on DNA, and the total DNA lengths. Physical-chemical explanations of observed results are presented. Our predictions are compared with experimental observations as well as with results from a continuum theory for the protein search. Extensive Monte Carlo computer simulations fully support our theoretical calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous Proteomic Discovery and Targeted Monitoring using Liquid Chromatography, Ion Mobility Spectrometry, and Mass Spectrometry

Current proteomics approaches are comprised of both broad discovery measurements as well as more quantitative targeted measurements. These two different measurement types are used to initially identify potentially important proteins (e.g., candidate biomarkers) and then enable improved quantification for a limited number of selected proteins. However, both approaches suffer from limitations, particularly the lower sensitivity, accuracy, and quantitation precision for discovery approaches compared to targeted approaches, and the limited proteome coverage provided by targeted approaches. Herein, we describe a new proteomics approach that allows both discovery and targeted monitoring (DTM) in a single analysis using liquid chromatography, ion mobility spectrometry and mass spectrometry (LC-IMS-MS). In DTM, heavy labeled peptides for target ions are spiked into tryptic digests and both the labeled and unlabeled peptides are broadly detected using LC-IMS-MS instrumentation, allowing the benefits of discovery and targeted approaches. To understand the possible improvement of the DTM approach, it was compared to LC-MS broad measurements using an accurate mass and time tag database and selected reaction monitoring (SRM) targeted measurements. The DTM results yielded greater peptide/protein coverage and a significant improvement in the detection of lower abundance species compared to LC-MS discovery measurements. DTM was also observed to have similar detection limits as SRM for the targeted measurements indicating its potential for combining the discovery and targeted approaches.

Environmental Molecular Sciences Laboratory↗

Requirements and Capabilities for Fielding Cryogenic DT-Containing Fill-Tube Targets for Direct-Drive Experiments on OMEGA

Improving the performance of direct-drive cryogenic targets at the Omega Laser Facility requires the development of a new cryogenic system to (i) field non permeable targets with a fill tube, and (ii) provide a clean environment around the target. This capability is to demonstrate that imploding a scaled-down version of the direct-drive–ignition target for the National Ignition Facility (NIF) on the OMEGA laser will generate the hot-spot pressure that is needed for ignition; this will justify future cryogenic direct-drive experiments on the NIF. The paper describes the target, the cryogenic equipment that is being constructed to achieve this goal, and the proposed target delivery process. Thermal calculations, fill-tube–based target designs, and structural/vibrational analyses are provided to demonstrate the credibility of the design. This new design will include capabilities not available (or possible) with the existing OMEGA cryogenic system, with the emphasis being to preserve a pristinely clean environment around the target, and to provide upgraded diagnostics to characterize both the ice layer and the target’s surface. The conceptual design is complete and testing of prototypes and subcomponents is underway. The rationale and capabilities of the new design are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of Magnetized Liner Inertial Fusion (MagLIF) Targets

Here, the magnetized liner inertial fusion (MagLIF) experimental campaign conducted at the University of Rochester’s Laboratory for Laser Energetics (LLE) has evolved significantly since its start in 2014. Scientific requirements and OMEGA EP system technology both have progressed, resulting in necessary and available updates to the target design. These include, but are not limited to: optimizing target dimensions and aspect ratios to maximize survival at desired pressures; coating target components to enhance physics diagnosis; precision-machining diagnostic windows along the axis of the target; improving fiducial placement reproducibility and reducing subsequent assembly time by 50%; and implementing gas-pressure transducers on the targets. In addition, target fabrication techniques have changed and improved, allowing for simpler target reproducibility and decreased assembly time. To date, eleven variations of targets have been fabricated, with successful target fielding ranging from 1 to 20atm internal pressure and a maximum survivability of 33atm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DMLC IMRT delivery to targets moving in 2D in Beam's Eye View

The goal of this article is to present the algorithm for DMLC leaf control capable of delivering IMRT to tumors that experience motion in two dimensions in the beams eye view (BEV) plane. The generic, two-dimensional (2D) motion of the projection of the rigid target on BEV plane can be divided into two components. The first component describes the motion of the projection of the target along the x axis (parallel to the MLC leaf motions) and the other describes the motion of the target projection on the y axis (perpendicular to the leaf motion direction). First, time optimal leaf trajectories are calculated independently for each leaf pair of the MLC assembly to compensate the x-axis component of the 2D motion of the target on the BEV. These leaf trajectories are then synchronized following the mid time (MT) synchronization procedure. To compensate for the y-axis component of the motion of the target projection on the BEV plane, the procedure of ''switching'' leaf pair trajectories in the upward (or downward) direction is executed when the target's BEV projection moves upward (or downward) from its equilibrium position along the y axis. When the intensity function is a 2D histogram, the error between the intended and delivered intensity in 2D DMLC IMRT delivery will depend on the shape of the intensity map and on the MLC physical constraint (leaf width and maximum admissible leaf speed). The MT synchronization of leaf trajectories decreases the impact of above constraints on the error in 2D DMLC IMRT intensity map delivery. The proof is provided, that if hardware constraints in the 2D DMLC IMRT delivery strategy are removed, the errors between planned and delivered 2D intensity maps are entirely eliminated. Examples of 2D DMLC IMRT delivery to rigid targets moving along elliptical orbits on BEV planes are calculated and analyzed for 20 clinical fluence maps. The comparisons between the intensity delivered without motion correction, with motion correction along x axis only, and with motion correction for full 2D motion of the target are calculated and quantitatively evaluated. The fluence maps were normalized to 100 MU and the rms difference between the desired and delivered fluence was 12 MU for no motion compensation, 11.18 MU for 1D compensation, and 4.73 MU for 2D motion compensations. The advantage of correcting for full 2D motion of target projected on the BEV plane is demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time tumor tracking: Automatic compensation of target motion using the Siemens 160 MLC

Purpose: Advanced high quality radiation therapy techniques such as IMRT require an accurate delivery of precisely modulated radiation fields to the target volume. Interfractional and intrafractional motion of the patient's anatomy, however, may considerably deteriorate the accuracy of the delivered dose to the planned dose distributions. In order to compensate for these potential errors, a dynamic real-time capable MLC control system was designed. Methods: The newly developed adaptive MLC control system contains specialized algorithms which are capable of continuous optimization and correction of the aperture of the MLC according to the motion of the target volume during the dose delivery. The algorithms calculate the new leaf positions based on target information provided online to the system. The algorithms were implemented in a dynamic target tracking control system designed for a Siemens 160 MLC. To assess the quality of the new target tracking system in terms of dosimetric accuracy, experiments with various types of motion patterns using different phantom setups were performed. The phantoms were equipped with radiochromic films placed between solid water slabs. Dosimetric results of exemplary deliveries to moving targets with and without dynamic MLC tracking applied were compared in terms of the gamma criterion to the reference dose delivered to a static phantom. Results: Our measurements indicated that dose errors for clinically relevant two-dimensional target motion can be compensated by the new control system during the dose delivery of open fields. For a clinical IMRT dose distribution, the gamma success rate was increased from 19% to 77% using the new tracking system. Similar improvements were achieved for the delivery of a complete IMRT treatment fraction to a moving lung phantom. However, dosimetric accuracy was limited by the system's latency of 400 ms and the finite leaf width of 5 mm in the isocenter plane. Conclusions: Different experimental setups representing different target tracking scenarios proved that the tracking concept, the new algorithms and the dynamic control system make it possible to effectively compensate for dose errors due to target motion in real-time. These early results indicate that the method is suited to increasing the accuracy and the quality of the treatment delivery for the irradiation of moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-133: Dosimetric Impact of Scan Orientation Relative to Target Motion During Spot Scanning Proton Therapy

Purpose: This study seeks to evaluate the dosimetric effects of intra-fraction motion during spot scanning proton beam therapy as a function of beam-scan orientation and target motion amplitude. Method: Multiple 4DCT scans were collected of a dynamic anthropomorphic phantom mimicking respiration amplitudes of 0 (static), 0.5, 1.0, and 1.5 cm. A spot-scanning treatment plan was developed on the maximum intensity projection image set, using an inverse-planning approach. Dynamic phantom motion was continuous throughout treatment plan delivery.The target nodule was designed to accommodate film and thermoluminescent dosimeters (TLD). Film and TLDs were uniquely labeled by location within the target. The phantom was localized on the treatment table using the clinically available orthogonal kV on-board imaging device. Film inserts provided data for dose uniformity; TLDs provided a 3% precision estimate of absolute dose. An inhouse script was developed to modify the delivery order of the beam spots, to orient the scanning direction parallel or perpendicular to target motion.TLD detector characterization and analysis was performed by the Imaging and Radiation Oncology Core group (IROC)-Houston. Film inserts, exhibiting a spatial resolution of 1mm, were analyzed to determine dose homogeneity within the radiation target. Results: Parallel scanning and target motions exhibited reduced target dose heterogeneity, relative to perpendicular scanning orientation. The average percent deviation in absolute dose for the motion deliveries relative to the static delivery was 4.9±1.1% for parallel scanning, and 11.7±3.5% (p<<0.05) for perpendicularly oriented scanning. Individual delivery dose deviations were not necessarily correlated to amplitude of motion for either scan orientation. Conclusions: Results demonstrate a quantifiable difference in dose heterogeneity as a function of scan orientation, more so than target amplitude. Comparison to the analyzed planar dose of a single field hint that multiple-field delivery alters intra-fraction beam-target motion synchronization and may mitigate heterogeneity, though further study is warranted.

60 APPLIED LIFE SCIENCES↗

SU-E-T-160: Evaluation of Accuracy for Target Margin Size Obtained From CBCT On Lung SBRT Based On Film Dosimetry

Purpose: To analysis delivered dose on target using gafchromic films for evaluating accuracy of target margin size obtained from cone beam computed tomography (CBCT) during lung stereotactic body radiation therapy (SBRT) Methods: The phantom consists of measurement part and driving part. The motor of Quasar motion phantom (Modus Medical Devices Inc, London, ON, Canada) was used for driving part and we developed measurement part which consist of cork cylindrical body and acrylic target with radiochromic film inserted into central and both ends of acrylic target. In this study lung SBRT cases through both four dimensional computed tomography (4DCT) and CBCT were selected. Target contouring including margin based on 4DCT is defined with a 1 cm margin around gross tumor volume (GTV) in all directions except for inferior direction. The moving range in inferior direction was larger than other directions thus, including 2 cm margin. In case of CBCT, the margin means blurring of target on CBCT images. This study was compared margin size determined through 4DCT and that of based on CBCT and we also evaluated dose profile and the length of margin in superior-inferior direction on CBCT compared with 4DCT. Results: The length of target including margin was 2.48 cm (based on CBCT) and 2.66 cm (based on 4DCT), respectively in superior-inferior direction. The difference of delivered dose on target between two margins was only within 1%. Conclusions: This study has shown the feasibility of determining target margin using CBCT for delivering more accurate prescription dose to lung cancer.

60 APPLIED LIFE SCIENCES↗

Comparison between target margins derived from 4DCT scans and real-time tumor motion tracking: Insights from lung tumor patients treated with robotic radiosurgery

Purpose: A unique capability of the CyberKnife system is dynamic target tracking. However, not all patients are eligible for this approach. Rather, their tumors are tracked statically using the vertebral column for alignment. When using static tracking, the internal target volume (ITV) is delineated on the four-dimensional (4D) CT scan and an additional margin is added to account for setup uncertainty [planning target volume (PTV)]. Treatment margins are difficult to estimate due to unpredictable variations in tumor motion and respiratory pattern during the course of treatment. The inability to track the target and detect changes in respiratory characteristics might result in geographic misses and local tumor recurrences. The purpose of this study is to develop a method to evaluate the adequacy of ITV-to-PTV margins for patients treated in this manner. Methods: Data from 24 patients with lesions in the upper lobe (n = 12), middle lobe (n = 3), and lower lobe (n = 9) were included in this study. Each patient was treated with dynamic tracking and underwent 4DCT scanning at the time of simulation. Data including the 3D coordinates of the target over the course of treatment were extracted from the treatment log files and used to determine actual target motion in the superior–inferior (S–I), anterior–posterior (A–P), and left–right (L–R) directions. Different approaches were used to calculate anisotropic and isotropic margins, assuming that the tumor moves as a rigid body. Anisotropic margins were calculated by separating target motion in the three anatomical directions, and a uniform margin was calculated by shifting the gross tumor volume contours in the 3D space and by computing the percentage of overlap with the PTV. The analysis was validated by means of a theoretical formulation. Results: The three methods provided consistent results. A uniform margin of 4.5 mm around the ITV was necessary to assure 95% target coverage for 95% of the fractions included in the analysis. In the case of anisotropic margins, the expansion required in the S–I direction was larger (8.1 mm) than those in the L–R (4.9 mm) and A–P (4.5 mm) directions. This margin accounts for variations of target position within the same treatment fraction. Conclusions: The use of bony alignment for CyberKnife lung stereotactic body radiation therapy requires careful considerations, in terms of the potential for increased toxicity or local miss. Our method could be used by other centers to determine the adequacy of ITV-to-PTV margins for their patients.

60 APPLIED LIFE SCIENCES↗

SU-E-T-495: Influence of Reduced Target-To-Nozzle Distance On Secondary Neutron Dose Equivalent in Proton and Carbon Ion Radiotherapy

Purpose: Ion beams have an unavoidable lateral spread due to nuclear interactions interacting with the air and monitoring systems. To minimize this spread, the distance between the nozzle and the patient should be kept as small as possible.The purpose of this work was to determine the impact of the target-to-nozzle distance reduction on the secondary neutron dose equivalent in proton and carbon ion radiotherapy. Methods: In this study, abdominal and head phantoms were scanned with our CT scanner. Cubical targets with side lengths of 3 cm to 10 cm and 1 cm to 5 cm were drawn in the abdominal and head phantoms respectively. Two intensity-modulated plans were made for each phantom and ion. The first of these plans placed the target at the isocenter while the other shifted the phantom 30 cm towards the nozzle. The plans at both phantom locations were optimized to provide identical dose coverage to the PTVs.Secondary neutron dose equivalent at 50 cm lateral to the center of target. Results: The neutron dose equivalent was higher for the larger field size from 0.25µSv per Gy (RBE) to 72µSv per Gy (RBE). The neutron dose equivalent was smaller when the phantom was placed at the upstream target location versus at the isocenter location by 8.9% to 10.4% and 11.0% to 22.1% for proton plans of the abdominal and head phantoms respectively. Differences for carbon plans with different target-to-nozzle locations were less than 3% for both phantoms. Conclusion: A reduction of target-to-nozzle distance can lead to benefits for proton radiotherapy. In this study, a reduction of secondary neutron dose equivalent was found for proton plans with a smaller target-to-nozzle distance. A greater impact was found for a head phantom with a smaller field size; however, a reduction of the target-to-nozzle distance had little effect for carbon therapy.

60 APPLIED LIFE SCIENCES↗

Structural basis for microRNA targeting

MicroRNAs (miRNAs) control expression of thousands of genes in plants and animals. miRNAs function by guiding Argonaute proteins to complementary sites in messenger RNAs (mRNAs) targeted for repression. In this paper, we determined crystal structures of human Argonaute-2 (Ago2) bound to a defined guide RNA with and without target RNAs representing miRNA recognition sites. These structures suggest a stepwise mechanism, in which Ago2 primarily exposes guide nucleotides (nt) 2 to 5 for initial target pairing. Pairing to nt 2 to 5 promotes conformational changes that expose nt 2 to 8 and 13 to 16 for further target recognition. Interactions with the guide-target minor groove allow Ago2 to interrogate target RNAs in a sequence-independent manner, whereas an adenosine binding-pocket opposite guide nt 1 further facilitates target recognition. Spurious slicing of miRNA targets is avoided through an inhibitory coordination of one catalytic magnesium ion. Finally, these results explain the conserved nucleotide-pairing patterns in animal miRNA target sites first observed over two decades ago.

59 BASIC BIOLOGICAL SCIENCES↗

Designs of Column Separation Processes for Recovery of Molybdenum from Dissolved High-Density LEU Target - Further Studies

The Global Threat Reduction Initiative (GTRI) Conversion Program develops technology necessary to convert civilian facilities that use high enriched uranium (HEU) to low enriched uranium (LEU) fuels and targets. The conversion of conventional HEU dispersion targets to LEU for the production of 99 Mo production requires approximately five times the uranium in a target to maintain the 99 Mo yield per target. Under GTRI, Argonne National Laboratory (Argonne) is developing two frontend options for the current processes to allow the use of LEU-foil targets. In both processes, the aim is to produce a product after the frontend that will be compatible with current purification operations and that will, with the same number of targets irradiated, provide the same or a higher yield of 99 Mo at the end of processing. The goal of the frontend process is to deliver a product solution that is of the same or higher Mo purity than the current solution and is of equal or better compatibility with current purification process. In the first frontend option, the LEU foil (contained in a thin [10–15 µm] Ni fission-recoil barrier) is removed from the annular target and dissolved in nitric acid. In the dissolution, the uranium, nickel, and all fission and activation products are dissolved; the solution will be ~7 mM Mo and ~450 g-U/L, and the nitricacid concentration after dissolution will be ~1 M. The resultant solution will then be run through a column to recover Mo from other target components; the Mo will be stripped from the column with a sodium hydroxide solution that will be compatible with the current purification processes used for dispersion targets. The volume of dissolved-foil solution is assumed to be 500 mL, and the pressure drop, ΔP, constraint of 0.8 atm is based on the use of vacuum/gravity fluid transfer system. Therefore pressure loss is limited to <1 atm; hence a value of 0.8 was chosen.

Stepinski, Dominique C.↗

Genome-Wide Analysis of miRNA targets in Brachypodium and Biomass Energy Crops

MicroRNAs (miRNAs) contribute to the control of numerous biological processes through the regulation of specific target mRNAs. Although the identities of these targets are essential to elucidate miRNA function, the targets are much more difficult to identify than the small RNAs themselves. Before this work, we pioneered the genome-wide identification of the targets of Arabidopsis miRNAs using an approach called PARE (German et al., Nature Biotech. 2008; Nature Protocols, 2009). Under this project, we applied PARE to Brachypodium distachyon (Brachypodium), a model plant in the Poaceae family, which includes the major food grain and bioenergy crops. Through in-depth global analysis and examination of specific examples, this research greatly expanded our knowledge of miRNAs and target RNAs of Brachypodium. New regulation in response to environmental stress or tissue type was found, and many new miRNAs were discovered. More than 260 targets of new and known miRNAs with PARE sequences at the precise sites of miRNA-guided cleavage were identified and characterized. Combining PARE data with the small RNA data also identified the miRNAs responsible for initiating approximately 500 phased loci, including one of the novel miRNAs. PARE analysis also revealed that differentially expressed miRNAs in the same family guide specific target RNA cleavage in a correspondingly tissue-preferential manner. The project included generation of small RNA and PARE resources for bioenergy crops, to facilitate ongoing discovery of conserved miRNA-target RNA regulation. By associating specific miRNA-target RNA pairs with known physiological functions, the research provides insights about gene regulation in different tissues and in response to environmental stress. This, and release of new PARE and small RNA data sets should contribute basic knowledge to enhance breeding and may suggest new strategies for improvement of biomass energy crops.

59 BASIC BIOLOGICAL SCIENCES↗

Estimating Beam-Target Heating

At Los Alamos National Laboratory, two high-current linear induction accelerators (LIAs) are used to produce bremsstrahlung source spots for flash radiography of high-explosive driven hydrodynamic experiments at the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility. Measurements of the electron-beam current density profile are valuable for understanding the beam dynamics in order to improve the quality of the radiography source spot. A technique commonly used at DARHT is to image the profile in Cerenkov or Optical Transition Radiation (OTR) light created by the beam striking a thin target inserted into the beam line. Target materials include aluminized dielectrics and titanium foils for OTR, and fused silica wafers for Cerenkov radiation. A practical complication with this technique is heating of the target by the electron beam. If the beam density is too great, the target can be destroyed. Moreover, even if the beam density is kept low enough to be nondestructive, the beam can heat the target to a high enough temperature to desorb gas from the surface. In that case, direct impact ionization of the gas by beam electrons can partially neutralize the beam, causing it to over-focus, thereby spoiling the data, if not destroying the target. The purpose of this note is to review some of the fundamental physics of electron beam heating in order to provide some elementary guidance for design of these imaging experiments to avoid overheating the target. Some specific examples for materials that we often use for imaging targets and beam-target experiments are provided.

43 PARTICLE ACCELERATORS↗

Testing of Helium-Cooled Metal Molybdenum Disk Target

NorthStar Medical Radioisotopes LLC is planning to produce an important medical radioisotope, molybdenum-99 (Mo-99), through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, it is desired to use as much beam power as possible to achieve maximum production yield and minimize target mass. This objective leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the main challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flowing on one side, making the window cooling even more challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess tensile strength as high as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and high thermal stress from beam heating. An Argonne team of scientists performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF) [3-7]. This report describes two series of tests for scale down production target designs that utilize full-scale 29 millimeters diameter, 0.75 mm thick press-and-sintered disks. We performed two thermal tests with different beam parameters and configurations of the disk laminations. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.

36 MATERIALS SCIENCE↗

Hear It? – New Physics Calls For a Healthy Target!

Nowadays, when the attention of the physics community is drawn to muon collider prospects and neutrino projects, a target as the primary source of such exotic particles is a key component of a particle physics experiment. The extreme conditions placed on the target, though, decrease its functionality and threaten the future of high-power targetry. Subject to superb magnetic fields, extreme temperatures, and radiation damage, the target is constantly at risk of unexpected failures. The Target Health Monitor (THM) aims to enable the continuous analysis of the target state throughout the experiment. Based on the optical concept of Brewster s angle and the reflectivity variation with the compositional changes in the target material, the THM will record and evaluate the radiation-caused transmutations in the target to foresee its malfunction before it affects the experimental results. The first steps in validating our THM concept have been made this summer. Continuing reflectivity measurements of the prospective target materials, we anticipate proving the THM potential to monitor target health effectively.

Havryshchuk, Kateryna↗

A High-Field Polarized 3 He Target for Jefferson Lab’s CLAS12 Spectrometer

Polarized 3He nuclear targets are invaluable surrogates for polarized neutron targets in spin-dependent scattering studies of the structure of matter. Traditional polarized 3He targets have seen steady improvements and active use over the last three decades, however they have been limited to operation in low magnetic fields. This has precluded their use in spectrometers that utilize high-magnetic-field tracking systems, such as Jefferson Lab's CLAS12 spectrometer. Developments in high-magnetic-field metastability exchange optical pumping of 3He, recently incorporated into the design of a polarized 3He ion source for RHIC and the EIC, could enable a new, polarized 3He fixed target to operate within high fields. Combining high-field techniques with the double-cell cryogenic target design used for the MIT-Bates 88-02 experiment, polarization and target density comparable to traditional polarized 3He targets could be reached while within a high magnetic field environment. We discuss the conceptual design for such a target, show our progress in this target's development, and outline plans for in-beams tests in Jefferson Lab's Hall B.

Maxwell, James↗