SU-E-J-55: Dosimetric Evaluation of Centrally Located Lung Tumors: A Monte Carlo (MC) Study of Lung SBRT Planning

Purpose: To compare dose distributions calculated using the iPlan XVMC algorithm and heterogeneities corrected/uncorrected Pencil Beam (PB-hete/PB-homo) algorithms for SBRT treatments of lung tumors. Methods: Ten patients with centrally located solitary lung tumors were treated using MC-based SBRT to 60Gy in 5 fractions for PTVV100%=95%. ITV was delineated on MIP-images based on 4D-CT scans. PTVs(ITV+5mm margins) ranged from 10.1–106.5cc(mean=48.6cc). MC-SBRT plans were generated with a combination of non-coplanar conformal arcs/beams using iPlan-XVMC-algorithm (BrainLABiPlan ver.4.1.2) for Novalis-TX consisting of HD-MLCs and 6MV-SRS(1000MU/min) mode, following RTOG 0813 dosimetric criteria. For comparison, PB-hete/PB-homo algorithms were used to re-calculate dose distributions using same beam configurations, MLCs/monitor units. Plans were evaluated with isocenter/maximal/mean doses to PTV. Normal lung doses were evaluated with V5/V10/V20 and mean-lung-dose(MLD), excluding PTV. Other OAR doses such as maximal spinal cord/2cc-esophagus/max bronchial tree (BT/maximal heart doses were tabulated. Results: Maximal/mean/isocenter doses to PTV calculated by PB-hete were uniformly larger than MC plans by a factors of 1.09/1.13/1.07, on average, whereas they were consistently lower by PB-homo by a factors of 0.9/0.84/0.9, respectively. The volume covered by 5Gy/10Gy/20Gy isodose-lines of the lung were comparable (average within±3%) when calculated by PB-hete compared to XVMC, but, consistently lower by PB-homo by a factors of 0.90/0.88/0.85, respectively. MLD was higher with PB-hete by 1.05, but, lower by PB-homo by 0.9, on average, compared to XVMC. XVMC max-cord/max-BT/max-heart and 2cc of esophagus doses were comparable to PB-hete; however, PB-homo underestimates by a factors of 0.82/0.89/0.88/0.86, on average, respectively. Conclusion: PB-hete significantly overestimates dose to PTV relative to XVMC -hence underdosing the target. MC is more complex and accurate with tissue-heterogeneities.The magnitude of variation significantly varies with ‘small-island-tumor’ surrounded by low-density lung tissues -PB algorithms lacks later electron scattering. Dose calculation with XVMC for lung SBRT is routinely performed in our clinic, its performance for head'neck/sinus cases will also be investigated.

60 APPLIED LIFE SCIENCES↗

SU-E-T-378: Limits and Possibilities of a Simplistic Approach to Whole Breast Radiation Therapy Planning

Purpose: Challenges for radiation therapy in developing countries include unreliable infrastructure and high patient load. We propose a system to treat whole breast in the prone position without computed tomography and/or planning software. Methods: Six parameters are measured using calipers and levels with the patient prone in the treatment position. (1) The largest separation; (2) the angle that separation makes with the horizontal; (3) the separation 2 cm posterior to the nipple; (4) the vertical distance between these two separations; (5) the sup/inf length and (6) angle of the desired posterior field edge. The data in (5) (6) and (2) provide field length, collimator and gantry angles. Isocenter is set to the midpoint of (1), anterior jaw setting is 20cm (half-beam setup), and the dose is prescribed to a point 1.5 cm anterior to isocenter. MUs and wedge angles are calculated using an MU calculator and by requiring 100% dose at that point and 100-105% at the midpoint of (3). Measurements on 30 CT scans were taken to obtain the data 1-6. To test the resulting MU/wedge combinations, they were entered into Eclipse (Varian) and dose distributions were calculated. The MU/wedge combinations were recorded and tabulated. Results: Performing a dose volume histogram analysis, the contoured breast V95 was 90.5%, and the average V90 was 94.1%. The maximum dose never exceeded 114.5%, (average 108%). The lung V20 was <5% for 96.7%, and the heart V5 was <10% for 93.3% of our sample. Conclusion: A method to provide prone whole breast treatment without CT-planning was developed. The method provides reasonable coverage and normal tissue sparing. This approach is not recommended if imaging and planning capabilities are available; it was designed to specifically avoid the need for CT planning and should be reserved to clinics that need to avoid that step.

60 APPLIED LIFE SCIENCES↗

SU-E-T-566: Comparison of VMAT and IMRT for Whole Abdomen Radiation Therapy (WART)

Purpose: Whole Abdomen Radiation Therapy (WART) is used in the treatment of desmoplastic small round cell tumors as well as other tumors with peritoneal dissemination. Intensity modulated radiation therapy (IMRT) is conventionally used to cover the multiple planning target volumes (PTVs) while sparing nearby critical structures, but this approach often requires two isocenters and ≥20 individual treatment fields. Four-field volumetric arc therapy (VMAT) can produce clinically similar treatment plans with the potential to reduce treatment time substantially. Here we examine treatment times and plan robustness for patients undergoing WART. Methods: Twenty patients undergoing WART at our institution were included in this study. Twelve IMRT and 8 VMAT plans utilized upper and lower abdominal isocenters and met similar dose constraints. Treatment times were tabulated from start of daily kV imaging to beam delivery end. Daily treatment couch coordinates were also recorded. From these couch coordinates, difference between actual and planned separation between isocenters was computed. Plan robustness with regard to PTV coverage within the region of field overlap was analyzed for 3 VMAT and 3 IMRT plans assuming a 2σ deviation in isocenter location. Results: The average treatment time for VMAT was 15 minutes shorter than for IMRT (27 minutes vs. 42 minutes). The average deviation in isocenter separation was 0.0 – 0.1 cm in each direction, with a standard deviation of 0.2 – 0.3 cm. Compared with IMRT plans, VMAT plans showed similar loss in PTV coverage for increasing isocenter displacement and similar dose inhomogeneity with decreasing isocenter displacement. Conclusion: Use of VMAT results in substantial time-savings for 2-isocenter whole abdomen radiotherapy plans. VMAT plans show robustness similar to IMRT with respect to isocenter displacement. VMAT should be considered for these very complicated treatments to minimize risk of patient movement during therapy and maximize treatment delivery efficiency.

60 APPLIED LIFE SCIENCES↗

TU-C-BRE-03: Aggregation of Linac Measurement Data

Purpose: Accurate data of linear accelerator radiation characteristics is important for treatment planning system commissioning as well as regular quality assurance of the machine. The RPC has performed site visits of numerous machines . Data gathered from Varian machines from the past 15 years are presented. The data collected can be used as a secondary check or when commissioning a new machine to verify that values are reasonable. Methods: Data from the past 15 years of RPC site visits was compiled and analyzed. Data was composed from measurements from approximately 400 Varian machines. Each dataset consists of several point measurements at various locations in a water phantom to measure percentage depth dose, output factors, including small MLC fields, off-axis factors, and wedge factors if applicable. Common statistical values are presented for each machine type. Where applicable, data was compared to other reference data given by the vendor or a select number of previous researchers. Results: Data is separated by energy and parameter and then analyzed by machine class. Data distributions of the parameter data were normal except occasionally at the tails. Distributions of the data for each class and parameter are tabulated to give not simply a singular reference value, but metrics about the distribution: 5th and 95th percentile values and the standard deviation as well as the median. Conclusion: The RPC has collected numerous data on Varian linacs and presented the finding of the past 15 years. The data can be used as a reference data set for physicists to compare against. A linac that deviates from the values does not necessarily indicate there is a problem as long as the treatment planning system correlates to the machine. Comparison of linac and treatment planning system data to external reference data can prevent serious treatment errors.

07 ISOTOPE AND RADIATION SOURCES↗

WE-D-BRF-05: Quantitative Dual-Energy CT Imaging for Proton Stopping Power Computation

Purpose: To extend the two-parameter separable basis-vector model (BVM) to estimation of proton stopping power from dual-energy CT (DECT) imaging. Methods: BVM assumes that the photon cross sections of any unknown material can be represented as a linear combination of the corresponding quantities for two bracketing basis materials. We show that both the electron density (ρe) and mean excitation energy (Iex) can be modeled by BVM, enabling stopping power to be estimated from the Bethe-Bloch equation. We have implemented an idealized post-processing dual energy imaging (pDECT) simulation consisting of monogenetic 45 keV and 80 keV scanning beams with polystyrene-water and water-CaCl2 solution basis pairs for soft tissues and bony tissues, respectively. The coefficients of 24 standard ICRU tissue compositions were estimated by pDECT. The corresponding ρe, Iex, and stopping power tables were evaluated via BVM and compared to tabulated ICRU 44 reference values. Results: BVM-based pDECT was found to estimate ρe and Iex with average and maximum errors of 0.5% and 2%, respectively, for the 24 tissues. Proton stopping power values at 175 MeV, show average/maximum errors of 0.8%/1.4%. For adipose, muscle and bone, these errors result range prediction accuracies less than 1%. Conclusion: A new two-parameter separable DECT model (BVM) for estimating proton stopping power was developed. Compared to competing parametric fit DECT models, BVM has the comparable prediction accuracy without necessitating iterative solution of nonlinear equations or a sample-dependent empirical relationship between effective atomic number and Iex. Based on the proton BVM, an efficient iterative statistical DECT reconstruction model is under development.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reduction of ring artifacts in CBCT: Detection and correction of pixel gain variations in flat panel detectors

Purpose: In using flat panel detectors (FPD) for cone beam computed tomography (CBCT), pixel gain variations may lead to structured nonuniformities in projections and ring artifacts in CBCT images. Such gain variations can be caused by change in detector entrance exposure levels or beam hardening, and they are not accounted by conventional flat field correction methods. In this work, the authors presented a method to identify isolated pixel clusters that exhibit gain variations and proposed a pixel gain correction (PGC) method to suppress both beam hardening and exposure level dependent gain variations. Methods: To modulate both beam spectrum and entrance exposure, flood field FPD projections were acquired using beam filters with varying thicknesses. “Ideal” pixel values were estimated by performing polynomial fits in both raw and flat field corrected projections. Residuals were calculated by taking the difference between measured and ideal pixel values to identify clustered image and FPD artifacts in flat field corrected and raw images, respectively. To correct clustered image artifacts, the ratio of ideal to measured pixel values in filtered images were utilized as pixel-specific gain correction factors, referred as PGC method, and they were tabulated as a function of pixel value in a look-up table. Results: 0.035% of detector pixels lead to clustered image artifacts in flat field corrected projections, where 80% of these pixels were traced back and linked to artifacts in the FPD. The performance of PGC method was tested in variety of imaging conditions and phantoms. The PGC method reduced clustered image artifacts and fixed pattern noise in projections, and ring artifacts in CBCT images. Conclusions: Clustered projection image artifacts that lead to ring artifacts in CBCT can be better identified with our artifact detection approach. When compared to the conventional flat field correction method, the proposed PGC method enables characterization of nonlinear pixel gain variations as a function of change in x-ray spectrum and intensity. Hence, it can better suppress image artifacts due to beam hardening as well as artifacts that arise from detector entrance exposure variation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-08: Comparison of Unintended Radiation Doses to Organs at Risk Resulting From the Out-Of-Field Therapeutic Beams and From Image-Guidance X-Ray Procedures

Purpose: The unintended radiation dose to organs at risk (OAR) can be contributed from imaging guidance procedures as well as from leakage and scatter of therapeutic beams. This study compares the imaging dose with the unintended out-of-field therapeutic dose to patient sensitive organs. Methods: The Monte Carlo EGSnrc user codes, BEAMnrc and DOSXYZnrc, were used to simulate kV X-ray sources from imaging devices as well as the therapeutic IMRT/VMAT beams and to calculate doses to target and OARs on patient treatment planning CT images. The accuracy of the Monte Carlo simulations was benchmarked against measurements in phantoms. The dose-volume histogram was utilized in analyzing the patient organ doses. Results: The dose resulting from Standard Head kV-CBCT scans to bone and soft tissues ranges from 0.7 to 1.1 cGy and from 0.03 to 0.3 cGy, respectively. The dose resulting from Thorax scans on the chest to bone and soft tissues ranges from 1.1 to 1.8 cGy and from 0.3 to 0.6 cGy, respectively. The dose resulting from Pelvis scans on the abdomen to bone and soft tissues range from 3.2 to 4.2 cGy and from 1.2 to 2.2 cGy, respectively. The out-of-field doses to OAR are sensitive to the distance between the treated target and the OAR. For a typical Head-and-Neck IMRT/VMAT treatment the out-of-field doses to eyes are 1–3% of the target dose, or 2–6 cGy per fraction. Conclusion: The imaging doses to OAR are predictable based on the imaging protocols used when OARs are within the imaged volume and can be estimated and accounted for by using tabulated values. The unintended out-of-field doses are proportional to the target dose, strongly depend on the distance between the treated target and OAR, and are generally higher comparing to the imaging dose. This work was partially supported by Varian research grant VUMC40590.

60 APPLIED LIFE SCIENCES↗

SU-E-T-31: A Fast Finite Size Pencil Beam (FSPB) Convolution Algorithm for a New Co-60 Arc Therapy Machine

Purpose: Present a fast Finite Size Pencil Beam (FSPB) convolution algorithm for a new Co-60 arc therapy machine. The FSPB algorithm accounts for (i) strong angular divergence (short SAD), (ii) heterogeneity effect for primary attenuation, and (iii) source energy spectrum. Methods: The FSPB algorithm is based on a 0.5×0.5-cm2 dose kernel calculated using the GEPTS (Gamma Electron and Positron Transport System) Monte Carlo code. The dose kernel is tabulated using a thin XYZ mesh (0.1 mm steps in lateral directions) for radius less than 1 cm and using an RZ mesh (with varying steps) for larger radial distance. To account for SSD effect, 11 dose kernels with SSDs varying between 30 cm to 80 cm are calculated. Maynord factor and “lateral stretching” are applied to account for differences between closest and actual SSD. Appropriate rotations and second order interpolation are used to calculate the dose from a given beamlet to a point. Results: Accuracy: Dose distributions in water with 80 cm SSD are calculated using the new FSPB convolution algorithm and full Monte Carlo simulation (gold standard). Figs 1–4 show excellent agreements between FSPB and Monte Carlo calculations for different field sizes and at different depths. The dose distribution for a prostate case is calculated using FSPB (Fig.5). Sixty conformal beams with rectum blocking are assumed. Figs 6–8 show the comparison with Monte Carlo simulation based on the same beam apertures. The excellent agreement demonstrates the accuracy of the new algorithm in handling SSD variation, oblique incidence, and scatter contribution.Speed: The FSPB convolution algorithm calculates 28 million dose points per second using a single 2.2-GHz CPU. The present algorithm is seven times faster than a similar algorithm from Gu et al. (Phys. Med. Biol. 54, 2009, 6287–6297). Conclusion: A fast and accurate FSPB convolution algorithm was developed and benchmarked.

60 APPLIED LIFE SCIENCES↗

SU-E-T-54: A New Method for Optimizing Radiation Isocenter for Linac-Based SRS

Purpose: To develop a new method to minimize deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter for all combinations of gantry and table angle. Methods: A set of ball-bearing (Winston-Lutz) images was used to determine the gantry radiation isocenter as the midrange of deviation values. Deviations in the cross-plane direction were minimized by calibration of MLC leaf position offset, and by adjusting beam position steering for each energy. Special attention was also paid to matching the absolute position of isocenter across all energies by adjusting position steering in the gun-target axis. Displacement of table axis from the gantry isocenter, and recommended table axis adjustment for contemporary Elekta linacs, was also determined. Eight images were used to characterize the volumetric isocenter for the full range of gantry and table rotations available. Tabulation of deviation for each beam was used to test compliance with isocenter tolerance. Results: Four contemporary Elekta linacs were evaluated and the radius in the gun-target axis of the radiation isocenter was 0.5 to 0.7 mm. After beam steering adjustment, the radius in the cross-plane direction was typically 0.2 to 0.4 mm. Position matching between energies can be reduced to 0.28 mm. Maximum total deviation was 0.68 to 1.07 mm, depending primarily on the effect of systematic table axis wobble with rotation. Conclusion: This new method effectively facilitates minimization of deviation between beam center and target position. The test, which requires a few minutes to perform, can be easily incorporated into a routine machine QA program. A tighter radiation isocenter for contemporary Elekta linacs would require reducing the effect of gantry arm flex and/or table axis wobble that are the two main components of deviation from the designated isocenter point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-116: Analysis of Patient Specific VMAT QA Passing Rates with Delta4 for Matched Machines

Purpose: To test whether unified vendor specified beam conformance for matched machines implies volumetric modulated arc radiotherapy(VMAT) delivery consistency. Methods: Twenty-two identical patient QA plans, eleven 6MV and eleven 15MV, were delivered to the Delta{sup 4}(Scandidos, Uppsala, Sweden) on two Varian TrueBEAM matched machines. Sixteen patient QA plans, nine 6 MV and seven 10 MV, were delivered to Delta{sup 4} on two Elekta Agility matched machines. The percent dose deviation(%DDev), distance-to-agreement(DTA), and the gamma analysis(γ) were collected for all plans and the differences in measurements were tabulated between matched machines. A paired t-test analysis of the data with an alpha of 0.05 determines statistical significance. Power(P) was calculated to detect a difference of 5%; all data except Elekta %DDev sets were strong with above a 0.85 power. Results: The average differences for Varian machines (%DDev, DTA, and γ) are 6.4%, 1.6% and 2.7% for 6MV, respectively, and 8.0%, 0.6%, and 2.5% for 15MV. The average differences for matched Elekta machines (%DDev, DTA, and γ) are 10.2%, 0.6% and 0.9% for 6 MV, respectively, and 7.0%, 1.9%, and 2.8% for 10MV.A paired t-test shows for Varian the %DDev difference is significant for 6MV and 15MV(p-value6MV=0.019, P6MV=0.96; p-value15MV=0.0003, P15MV=0.86). Differences in DTA are insignificant for both 6MV and 15MV(p-value6MV=0.063, P6MV=1; p-value15MV=0.907, P15MV=1). Varian differences in gamma are significant for both energies(p-value6MV=0.025, P6MV=0.99; p-value15MV=0.013, P15MV=1). A paired t-test shows for Elekta the difference in %DDev is significant for 6MV but not 10MV(p-value6MV=0.00065, P6MV=0.68; p-value10MV=0.262, P10MV=0.39). Differences in DTA are statistically insignificant(p-value6MV=0.803, P6MV = 1; p-value10MV=0.269, P10MV=1). Elekta differences in gamma are significant for 10MV only(p-value6MV=0.094, P6MV=1; p-value10MV=0.011, P10MV=1). Conclusion: These results show vendor specified beam conformance across machines does not ensure equivalent patient specific QA pass rates. Gamma differences are statistically significant in three of the four comparisons for two pairs of vendor matched machines.

60 APPLIED LIFE SCIENCES↗

SU-E-T-149: Brachytherapy Patient Specific Quality Assurance for a HDR Vaginal Cylinder Case

Purpose: Commonly Ir-192 HDR treatment planning system commissioning is only based on a single absolute measurement of source activity supplemented by tabulated parameters for multiple factors without independent verification that the planned distribution corresponds to the actual delivered dose. The purpose on this work is to present a methodology using Gafchromic film with a statistically valid calibration curve that can be used to validate clinical HDR vaginal cylinder cases by comparing the calculated plan dose distribution in a plane with the corresponding measured planar dose. Methods: A vaginal cylinder plan was created with Oncentra treatment planning system. The 3D dose matrix was exported to a Varian Eclipse work station for convenient extraction of a 2D coronal dose plane corresponding to the film position. The plan was delivered with a sheet of Gafchromic EBT3 film positioned 1mm from the catheter using an Ir-192 Nucletron HDR source. The film was then digitized with an Epson 10000 XL color scanner. Film analysis is performed with MatLab imaging toolbox. A density to dose calibration curve was created using TG43 formalism for a single dwell position exposure at over 100 points for statistical accuracy. The plan and measured film dose planes were registered using a known dwell position relative to four film marks. The plan delivered 500 cGy to points 2 cm from the sources. Results: The distance to agreement of the 500 cGy isodose between the plan and film measurement laterally was 0.5 mm but can be as much as 1.5 mm superior and inferior. The difference between the computed plan dose and film measurement was calculated per pixel. The greatest errors up to 50 cGy are near the apex. Conclusion: The methodology presented will be useful to implement more comprehensive quality assurance to verify patient-specific dose distributions.

60 APPLIED LIFE SCIENCES↗

SU-E-T-226: Correction of a Standard Model-Based Dose Calculator Using Measurement Data

Purpose: To propose a hybrid method that combines advantages of the model-based and measurement-based method for independent dose calculation. Modeled-based dose calculation, such as collapsed-cone-convolution/superposition (CCCS) or the Monte-Carlo method, models dose deposition in the patient body accurately; however, due to lack of detail knowledge about the linear accelerator (LINAC) head, commissioning for an arbitrary machine is tedious and challenging in case of hardware changes. On the contrary, the measurement-based method characterizes the beam property accurately but lacks the capability of dose disposition modeling in heterogeneous media. Methods: We used a standard CCCS calculator, which is commissioned by published data, as the standard model calculator. For a given machine, water phantom measurements were acquired. A set of dose distributions were also calculated using the CCCS for the same setup. The difference between the measurements and the CCCS results were tabulated and used as the commissioning data for a measurement based calculator. Here we used a direct-ray-tracing calculator (ΔDRT). The proposed independent dose calculation consists of the following steps: 1. calculate D-model using CCCS. 2. calculate D-ΔDRT using ΔDRT. 3. combine Results: D=D-model+D-ΔDRT. Results: The hybrid dose calculation was tested on digital phantoms and patient CT data for standard fields and IMRT plan. The results were compared to dose calculated by the treatment planning system (TPS). The agreement of the hybrid and the TPS was within 3%, 3 mm for over 98% of the volume for phantom studies and lung patients. Conclusion: The proposed hybrid method uses the same commissioning data as those for the measurement-based method and can be easily extended to any non-standard LINAC. The results met the accuracy, independence, and simple commissioning criteria for an independent dose calculator.

60 APPLIED LIFE SCIENCES↗

SU-E-T-409: Evaluation of Tissue Composition Effect On Dose Distribution in Radiotherapy with 6 MV Photon Beam of a Medical Linac

Purpose: The aim of this study is to evaluate soft tissue composition effect on dose distribution for various soft tissues and various depths in radiotherapy with 6 MV photon beam of a medical linac. Methods: A phantom and Siemens Primus linear accelerator were simulated using MCNPX Monte Carlo code. In a homogeneous cubic phantom, six types of soft tissue and three types of tissue-equivalent materials were defined separately. The soft tissues were muscle (skeletal), adipose tissue, blood (whole), breast tissue, soft tissue (9-component) and soft tissue (4-component). The tissue-equivalent materials included: water, A-150 tissue-equivalent plastic and perspex. Photon dose relative to dose in 9-component soft tissue at various depths on the beam’s central axis was determined for the 6 MV photon beam. The relative dose was also calculated and compared for various MCNPX tallies including,F8, F6 and,F4. Results: The results of the relative photon dose in various materials relative to dose in 9-component soft tissue and using different tallies are reported in the form of tabulated data. Minor differences between dose distributions in various soft tissues and tissue-equivalent materials were observed. The results from F6 and F4 were practically the same but different with,F8 tally. Conclusion: Based on the calculations performed, the differences in dose distributions in various soft tissues and tissue-equivalent materials are minor but they could be corrected in radiotherapy calculations to upgrade the accuracy of the dosimetric calculations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-552: Monte Carlo Calculation of Correction Factors for a Free-Air Ionization Chamber in Support of a National Air-Kerma Standard for Electronic Brachytherapy

Purpose: To use Monte Carlo radiation transport methods to calculate correction factors for a free-air ionization chamber in support of a national air-kerma standard for low-energy, miniature x-ray sources used for electronic brachytherapy (eBx). Methods: The NIST is establishing a calibration service for well-type ionization chambers used to characterize the strength of eBx sources prior to clinical use. The calibration approach involves establishing the well-chamber’s response to an eBx source whose air-kerma rate at a 50 cm distance is determined through a primary measurement performed using the Lamperti free-air ionization chamber. However, the free-air chamber measurements of charge or current can only be related to the reference air-kerma standard after applying several corrections, some of which are best determined via Monte Carlo simulation. To this end, a detailed geometric model of the Lamperti chamber was developed in the EGSnrc code based on the engineering drawings of the instrument. The egs-fac user code in EGSnrc was then used to calculate energy-dependent correction factors which account for missing or undesired ionization arising from effects such as: (1) attenuation and scatter of the x-rays in air; (2) primary electrons escaping the charge collection region; (3) lack of charged particle equilibrium; (4) atomic fluorescence and bremsstrahlung radiation. Results: Energy-dependent correction factors were calculated assuming a monoenergetic point source with the photon energy ranging from 2 keV to 60 keV in 2 keV increments. Sufficient photon histories were simulated so that the Monte Carlo statistical uncertainty of the correction factors was less than 0.01%. The correction factors for a specific eBx source will be determined by integrating these tabulated results over its measured x-ray spectrum. Conclusion: The correction factors calculated in this work are important for establishing a national standard for eBx which will help ensure that dose is accurately and consistently delivered to patients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-E-18: Training Monthly QA of Medical Accelerators: Illustrated Instructions for Self-Learning

Purpose: To develop and test clear illustrated instructions for training of monthly mechanical QA of medical linear accelerators. Methods: Illustrated instructions were created for monthly mechanical QA with tolerance tabulated, and underwent several steps of review and refinement. Testers with zero QA experience were then recruited from our radiotherapy department (1 student, 2 computational scientists and 8 dosimetrists). The following parameters were progressively de-calibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (5 testers); Group B = Group A + wall laser position, couch lateral and vertical position, collimator angle (3 testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (3 testers). Testers were taught how to use the linac, and then used the instructions to try to identify these errors. A physicist observed each session, giving support on machine operation, as necessary. The instructions were further tested with groups of therapists, graduate students and physics residents at multiple institutions. We have also changed the language of the instructions to simulate using the instructions with non-English speakers. Results: Testers were able to follow the instructions. They determined gantry, collimator and couch angle errors within 0.4, 0.3, and 0.9degrees of the actual changed values, respectively. Laser positions were determined within 1mm, and jaw positions within 2mm. Couch position errors were determined within 2 and 3mm for lateral/longitudinal and vertical errors, respectively. Accessory positioning errors were determined within 1mm. ODI errors were determined within 2mm when comparing with distance sticks, and 6mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. Conclusion: Inexperienced users were able to follow these instructions, and catch errors within the criteria suggested by AAPM TG142 for linacs used for IMRT.

60 APPLIED LIFE SCIENCES↗

SU-F-J-17: Patient Localization Using MRI-Guided Soft Tissue for Head-And-Neck Radiotherapy: Indication for Margin Reduction and Its Feasibility

Purpose: On-board MRI provides superior soft-tissue contrast, allowing patient alignment using tumor or nearby critical structures. This study aims to study H&N MRI-guided IGRT to analyze inter-fraction patient setup variations using soft-tissue targets and design appropriate CTV-to-PTV margin and clinical implication. Methods: 282 MR images for 10 H&N IMRT patients treated on a ViewRay system were retrospectively analyzed. Patients were immobilized using a thermoplastic mask on a customized headrest fitted in a radiofrequency coil and positioned to soft-tissue targets. The inter-fraction patient displacements were recorded to compute the PTV margins using the recipe: 2.5∑+0.7σ. New IMRT plans optimized on the revised PTVs were generated to evaluate the delivered dose distributions. An in-house dose deformation registration tool was used to assess the resulting dosimetric consequences when margin adaption is performed based on weekly MR images. The cumulative doses were compared to the reduced margin plans for targets and critical structures. Results: The inter-fraction displacements (and standard deviations), ∑ and σ were tabulated for MRI and compared to kVCBCT. The computed CTV-to-PTV margin was 3.5mm for soft-tissue based registration. There were minimal differences between the planned and delivered doses when comparing clinical and the PTV reduced margin plans: the paired t-tests yielded p=0.38 and 0.66 between the planned and delivered doses for the adapted margin plans for the maximum cord and mean parotid dose, respectively. Target V95 received comparable doses as planned for the reduced margin plans. Conclusion: The 0.35T MRI offers acceptable soft-tissue contrast and good spatial resolution for patient alignment and target visualization. Better tumor conspicuity from MRI allows soft-tissue based alignments with potentially improved accuracy, suggesting a benefit of margin reduction for H&N radiotherapy. The reduced margin plans (i.e., 2 mm) resulted in improved normal structure sparing and accurate dose delivery to achieve intended treatment goal under MR guidance.

60 APPLIED LIFE SCIENCES↗

SU-F-J-46: Feasibility of Cerenkov Emission for Absorption Spectroscopy

Purpose: Cerenkov emission (CE) is a promising tool for online tumor microenvironment interrogation and targeting during radiotherapy. In this work, we utilize CE generated during radiotherapy as a broadband excitation source for real-time absorption spectroscopy. We demonstrate the feasibility of CE spectroscopy using a controlled experiment of materials with known emission/absorption properties. Methods: A water tank is irradiated with 20 MeV electron beam to induce Cerenkov emission. Food coloring dyes (Yellow #5, Red #40, and Blue #1), which have known emission/absorption properties were added to the water tank with increasing concentration (1 drop (0.05 mL), 2 drops, and 4 drops from a dispenser bottle). The signal is collected using a condensing lens which is coupled into a 20m optical fiber that is fed into a spectrometer that measures the emitted spectra. The resulting spectra from water/food coloring dye solutions were normalized by the reference spectrum, which is the Cerenkov spectrum of pure water, correcting for both the nonlinearity of the broadband Cerenkov emission spectrum as well as the non-uniform spectral response of the spectrometer. The emitted spectra were then converted into absorbance and their characteristics were analyzed. Results: The food coloring dye had a drastic change on the Cerenkov emission, shifting its wavelength according to its visible color. The collected spectra showed various absorbance peaks which agrees with tabulated peak positions of the dyes added within 0.3% for yellow, 1.7% for red, and 0.16% for blue. The CE peak heights proportionally increased as the dye concentration is increased. Conclusion: This work shows the potential for real-time functional spectroscopy using Cerenkov emission during radiotherapy. It was demonstrated that molecule identification as well as relative concentration can be extracted from the Cerenkov emission color shift.

60 APPLIED LIFE SCIENCES↗

SU-F-J-47: Inherent Uncertainty in the Positional Shifts Determined by a Volumetric Cone Beam Imaging System

Purpose: To quantify inherent uncertainty associated with a volumetric imaging system in its determination of positional shifts. Methods: The study was performed on an Elekta Axesse™ linac’s XVI cone beam computed tomography (CBCT) system. A CT image data set of a Penta- Guide phantom was used as reference image by placing isocenter at the center of the phantom.The phantom was placed arbitrarily on the couch close to isocenter and CBCT images were obtained. The CBCT dataset was matched with the reference image using XVI software and the shifts were determined in 6-dimensions. Without moving the phantom, this process was repeated 20 times consecutively within 30 minutes on a single day. Mean shifts and their standard deviations in all 6-dimensions were determined for all the 20 instances of imaging. For any given day, the first set of shifts obtained was kept as reference and the deviations of the subsequent 19 sets from the reference set were scored. Mean differences and their standard deviations were determined. In this way, data were obtained for 30 consecutive working days. Results: Tabulating the mean deviations and their standard deviations observed on each day for the 30 measurement days, systematic and random errors in the determination of shifts by XVI software were calculated. The systematic errors were found to be 0.03, 0.04 and 0.03 mm while random errors were 0.05, 0.06 and 0.06 mm in lateral, craniocaudal and anterio-posterior directions respectively. For rotational shifts, the systematic errors were 0.02°, 0.03° and 0.03° and random errors were 0.06°, 0.05° and 0.05° in pitch, roll and yaw directions respectively. Conclusion: The inherent uncertainties in every image guidance system should be assessed and baseline values established at the time of its commissioning. These shall be periodically tested as part of the QA protocol.

60 APPLIED LIFE SCIENCES↗