Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

The Lick Observatory Supernova Search follow-up program: photometry data release of 70 SESNe

We present BVRI and unfiltered (Clear) light curves of 70 stripped-envelope supernovae (SESNe), observed between 2003 and 2020, from the Lick Observatory Supernova Search follow-up program. Our SESN sample consists of 19 spectroscopically normal SNe Ib, 2 peculiar SNe Ib, six SNe Ibn, 14 normal SNe Ic, 1 peculiar SN Ic, 10 SNe Ic-BL, 15 SNe IIb, 1 ambiguous SN IIb/Ib/c, and 2 superluminous SNe. Our follow-up photometry has (on a per-SN basis) a mean coverage of 81 photometric points (median of 58 points) and a mean cadence of 3.6 d (median of 1.2 d). From our full sample, a subset of 38 SNe have pre-maximum coverage in at least one passband, allowing for the peak brightness of each SN in this subset to be quantitatively determined. We describe our data collection and processing techniques, with emphasis toward our automated photometry pipeline, from which we derive publicly available data products to enable and encourage further study by the community. Using these data products, we derive host-galaxy extinction values through the empirical colour evolution relationship and, for the first time, produce accurate rise-time measurements for a large sample of SESNe in both optical and infrared passbands. By modelling multiband light curves, we find that SNe Ic tend to have lower ejecta masses and lower ejecta velocities than SNe Ib and IIb, but higher 56Ni masses.

Lick Observatory↗

High-Field One-Dimensional and Two-Dimensional 27Al Magic-Angle Spinning Nuclear Magnetic Resonance Study of ?-, d-, and ?-Al2O3 Dominated Aluminum Oxides: Toward Understanding the Al Sites in ?-Al2O3

Herein, a detailed analysis was carried out using high-field (19.9 T) 27Al magic-angle spinning (MAS) nuclear magnetic resonance (NMR) on three specially prepared aluminum oxide samples where the ?-, d-, and ?-Al2O3 phases are dominantly expressed through careful control of the synthesis conditions. Specifically, two-dimensional (2D) multiquantum (MQ) MAS 27Al was used to obtain high spectral resolution, which provided a guide for analyzing quantitative 1D 27Al NMR spectra. Six aluminum sites were resolved in the 2D MQ MAS NMR spectra, and seven aluminum sites were required to fit the 1D spectra. A set of octahedral and tetrahedral peaks with well-defined quadrupolar line shapes was observed in the ?-phase dominant sample and was unambiguously assigned to the ?-Al2O3 phase. The distinct line shapes related to the ?-Al2O3 phase provided an opportunity for effectively deconvoluting the more complex spectrum obtained from the d-Al2O3 dominant sample, allowing the peaks/quadrupolar parameters related to the d-Al2O3 phase to be extracted. The results show that the d-Al2O3 phase contains three distinct AlO sites and three distinct AlT sites. This detailed Al site structural information offers a powerful way of analyzing the most complex ?-Al2O3 spectrum. It is found that the ?-Al2O3 phase consists of Al sites with local structures similar to those found in the d-Al2O3 and ?-Al2O3 phases albeit with less ordering. Spin–lattice relaxation time measurement further confirms the disordering of the lattice. Collectively, this study uniquely assigns 27Al features in transition aluminas, offering a simplified method to quantify complex mixtures of aluminum sites in transition alumina samples.

Xu, Suochang↗

Synchronized operation by field programmable gate array based signal controller for the Thomson scattering diagnostic system in KSTAR

The Thomson scattering diagnostic system is successfully installed in the Korea Superconducting Tokamak Advanced Research (KSTAR) facility. We got the electron temperature and electron density data for the first time in 2011, 4th campaign using a field programmable gate array (FPGA) based signal control board. It operates as a signal generator, a detector, a controller, and a time measuring device. This board produces two configurable trigger pulses to operate Nd:YAG laser system and receives a laser beam detection signal from a photodiode detector. It allows a trigger pulse to be delivered to a time delay module to make a scattered signal measurement, measuring an asynchronous time value between the KSTAR timing board and the laser system injection signal. All functions are controlled by the embedded processor running on operating system within a single FPGA. It provides Ethernet communication interface and is configured with standard middleware to integrate with KSTAR. This controller has operated for two experimental campaigns including commissioning and performed the reconfiguration of logic designs to accommodate varying experimental situation without hardware rebuilding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated evaluation of setup errors in carbon ion therapy using PET: Feasibility study

Purpose: To investigate the possibility of detecting patient mispositioning in carbon-ion therapy with particle therapy positron emission tomography (PET) in an automated image registration based manner. Methods: Tumors in the head and neck (H and N), pelvic, lung, and brain region were investigated. Biologically optimized carbon ion treatment plans were created with TRiP98. From these treatment plans, the reference β{sup +}-activity distributions were calculated using a Monte Carlo simulation. Setup errors were simulated by shifting or rotating the computed tomography (CT). The expected β{sup +} activity was calculated for each plan with shifts. Finally, the reference particle therapy PET images were compared to the “shifted” β{sup +}-activity distribution simulations using the Pearson's correlation coefficient (PCC). To account for different PET monitoring options the inbeam PET was compared to three different inroom scenarios. Additionally, the dosimetric effects of the CT misalignments were investigated. Results: The automated PCC detection of patient mispositioning was possible in the investigated indications for cranio-caudal shifts of 4 mm and more, except for prostate tumors. In the rather homogeneous pelvic region, the generated β{sup +}-activity distribution of the reference and compared PET image were too much alike. Thus, setup errors in this region could not be detected. Regarding lung lesions the detection strongly depended on the exact tumor location: in the center of the lung tumor misalignments could be detected down to 2 mm shifts while resolving shifts of tumors close to the thoracic wall was more challenging. Rotational shifts in the H and N and lung region of +6° and more could be detected using inroom PET and partly using inbeam PET. Comparing inroom PET to inbeam PET no obvious trend was found. However, among the inroom scenarios a longer measurement time was found to be advantageous. Conclusions: This study scopes the use of various particle therapy PET verification techniques in four indications. The automated detection of patients' setup errors was investigated in a broad accumulation of data sets. The evaluation of introduced setup errors is performed automatically, which is of utmost importance to introduce highly required particle therapy monitoring devices into the clinical routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Space and Time Resolved Measurements of the Heating of Solids to Ten Million Kelvin by a Petawatt Laser

The heating of plane solid targets by the Vulcan petawatt laser at powers of 0.32-0.73 PW and intensities of up to 4 x 10^20 W cm^-2 has been diagnosed with a temporal resolution of 17 ps and a spatial resolution of 30 um, by measuring optical emission from the opposite side of the target to the laser with a streak camera. Second harmonic emission was filtered out and the target viewed at an angle to eliminate optical transition radiation. Spatial resolution was obtained by imaging the emission onto a bundle of fibre optics, arranged into a one-dimensional array at the camera entrance. The results show that a region 160 um in diameter can be heated to a temperature of ~10^7 K (kT/e ~ keV) in solid targets from 10 to 20 um thick and that this temperature is maintained for at least 20 ps, confirming the utility of PW lasers in the study of high energy density physics. Hybrid code modelling shows that magnetic field generation prevents increased target heating by electron refluxing above a certain target thickness and that the absorption of laser energy into electrons entering the solid target was between 15-30%, and tends to increase with laser energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and Theoretical Study of Molecular Response of Amine Bases in Organic Solvents

Reorientational correlation times of various amine bases (viz., pyridine, 2,6-lutidene, 2,2,6,6-tetramethylpiperidine) and organic solvents (dichloromethane, toluene) were determined by solution-state NMR relaxation time measurements and compared with predictions from molecular dynamics (MD) simulations. The bases and solvents are reagents in complex reactions involving Frustrated Lewis Pairs (FLP), which display remarkable catalytic activity in metal-free H2 scission. The comparison of measured and simulated correlation times is a key test of the ability of recent MD and quantum electronic structure calculations to elucidate the mechanism of FLP activity. Correla- tion times were found to be in the range 1.4-3.4 ps (NMR) and 1.23-5.28 ps (MD) for the amines, and 0.9-2.3 ps (NMR) and 0.2-1.7 ps (MD) for the solvent molecules. This work was supported by the U.S. Department of Energy, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Biosciences. Pacic Northwest National Laboratory (PNNL) is a multiprogram national laboratory operated for DOE by Battelle.

Frustrated Lewis pairs↗

GEOMETRIC AND DYNAMICAL MODELS OF REVERBERATION MAPPING DATA

We present a general method to analyze reverberation (or echo) mapping data that simultaneously provides estimates for the black hole mass and for the geometry and dynamics of the broad-line region (BLR) in active galactic nuclei (AGNs). While previous methods yield a typical scale size of the BLR or a reconstruction of the transfer function, our method directly infers the spatial and velocity distribution of the BLR from the data, from which a transfer function can be easily derived. Previous echo mapping analysis requires an independent estimate of a scaling factor known as the virial coefficient to infer the mass of the black hole, but this is not needed in our more direct approach. We use the formalism of Bayesian probability theory and implement a Markov Chain Monte Carlo algorithm to obtain estimates and uncertainties for the parameters of our BLR models. Fitting of models to the data requires knowledge of the continuum flux at all times, not just the measured times. We use Gaussian Processes to interpolate and extrapolate the continuum light curve data in a fully consistent probabilistic manner, taking the associated errors into account. We illustrate our method using simple models of BLR geometry and dynamics and show that we can recover the parameter values of our test systems with realistic uncertainties that depend upon the variability of the AGN and the quality of the reverberation mapping observing campaign. With a geometry model we can recover the mean radius of the BLR to within {approx}0.1 dex random uncertainty for simulated data with an integrated line flux uncertainty of 1.5%, while with a dynamical model we can recover the black hole mass and the mean radius to within {approx}0.05 dex random uncertainty, for simulated data with a line profile average signal-to-noise ratio of 4 per spectral pixel. These uncertainties do not include modeling errors, which are likely to be present in the analysis of real data, and should therefore be considered as lower limits to the accuracy of the method.

79 ASTRONOMY AND ASTROPHYSICS↗