Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Machine Learning Analysis of Temperature-Strain Relationships for Structural Health Monitoring of Pipes: Self-powered wireless sensor system for health monitoring of liquid-sodium cooled fast reactors

This report presents machine learning (ML) analysis of temperature-strain relationships for structural health monitoring of nuclear reactor stainless steel (SS) pipes with the strain gauge sensor directly printed on the pipe with a 3D conformal aerosol jet printer. We investigate correlations for two sensor pairs installed on the same SS304 pipe: commercial K-type thermocouple with a printed gold strain gauge (TC3-SG3), and commercial K-type thermocouple with commercial Kyowa strain gauge (TC0-SG0). The temperature ranges for the sensor pairs TC0-SG0 and TC3-SG3 are 20.00°C to 266.37°C and 39.95°C to 219.28°C respectively. ML algorithms in this study include Linear Regression (baseline method), Ridge Regression, Lasso Regression, and Gradient Boosting. Performance evaluation metrics include Root Mean Square Error (RMSE), Mean Square Error (MSE), Mean Absolute Error (MAE), R 2 Score, and Explained Variance. Using advanced feature engineering techniques, we extracted 27 temperature-based features and 30 strategic inclusion features. The best performance was obtained with the Gradient Boosting method, which achieves prediction accuracy of R 2 = 0.9999 and RMSE = 7.69 μStrain for TC0-SG0, and R 2 = 0.9998 and RMSE = 18.03 μStrain for TC3-SG3. While the temperature-strain correlations are weaker for the gauge directly printed on the pipe than for the commercial strain gauge, deployment-ready performance exceeding industry standards is achieved for both sensor pairs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Bottom Anode Monitoring in DC Electric Arc Furnaces Using Fiber-Optic Sensors

A pin style bottom anode employs conductive steel rods that serve as the pathway for the high electrical power through rammed refractory at the bottom of a DC Electric Arc Furnace (EAF). Anode wear during operation is important to monitor, as anode replacement is expensive and impacts EAF productivity. Liquid steel penetration into the un-sintered refractory layer can result from rapid electrical power ramp-up, dips in furnace temperature, or operating the anode for too long between EAF campaigns. In extreme cases, the liquid steel may penetrate the bottom of the furnace when anode wear progresses too close to the bottom shell, which is extremely dangerous and must be avoided. The current state of the art for monitoring bottom anode wear employs thermocouples imbedded in the anode pins at points in the anode. However, this approach is not sensitive enough to detect localized damage to the anode, especially when cracking occurs. Here, the present work utilizes fiber optic sensors to monitor the health of the anode, by creating a real-time spatially distributed temperature map of the anode. Unlike the traditional thermocouples, these sensors can be mounted at significantly greater depths, provide distributed temperature measurements, and can withstand temperatures of up to 900°C. Additionally, they are able to perform temperature measurements with a spatial resolution of 1.3 mm at a 5 Hz acquisition rate, providing unprecedented high-density real time monitoring of anode health and increasing the efficiency, and safety of EAF operation.

Bottom Anode↗

Monitoring of Temperature Measurements for Different Flow Regimes in Water and Galinstan with Long Short-Term Memory Networks and Transfer Learning of Sensors

Temperature sensing is one of the most common measurements of a nuclear reactor monitoring system. The coolant fluid flow in a reactor core depends on the reactor power state. We investigated the monitoring and estimation of the thermocouple time series using machine learning for a range of flow regimes. Measurement data were obtained, in two separate experiments, in a flow loop filled with water and with liquid metal Galinstan. We developed long short-term memory (LSTM) recurrent neural networks (RNNs) for sensor predictions by training on the sensor’s own prior history, and transfer learning LSTM (TL-LSTM) by training on a correlated sensor’s prior history. Sensor cross-correlations were identified by calculating the Pearson correlation coefficient of the time series. The accuracy of LSTM and TL-LSTM predictions of temperature was studied as a function of Reynolds number (Re). The root-mean-square error (RMSE) for the test segment of time series of each sensor was shown to linearly increase with Re for both water and Galinstan fluids. Using linear correlations, we estimated the range of values of Re for which RMSE is smaller than the thermocouple measurement uncertainty. For both water and Galinstan fluids, we showed that both LSTM and TL-LSTM provide reliable estimations of temperature for typical flow regimes in a nuclear reactor. The LSTM runtime was shown to be substantially smaller than the data acquisition rate, which allows for performing estimation and validation of sensor measurements in real time.

Pantopoulou, Stella↗

Impact to Cooling Airflow from Truck Platooning

We investigate tradeoffs between the airflow strategies related to engine cooling and the aerodynamic-enabled fuel savings created by platooning. By analyzing air temperatures, engine temperatures and cooling air flow at different platoon distances, we show the thermal impact to the engine from truck platooning. Previously, we collected wind and thermal data for numerous heavy-duty truck platoon configurations (gaps ranging from 4 to 87 meters) and reported the significant fuel savings enabled by these configurations. The fuel consumption for all trucks in the platoon were measured using the SAE J1321 gravimetric procedure as well as calibrated J1939 instantaneous fuel rate while travelling at 65 mph and loaded to a gross weight of 65,000 lb. Using thermocouples mounted 1 m ahead of each truck, anemometers at the grill and a grid of under-hood thermocouples as well as J1939 reported engine temperatures, we analyze the impact to critical operating temperatures from different platoon configurations. Results show significant changes in the engine and under-hood air temperatures that correlate with vehicle gap distance and platoon position.

adaptive cruise control (ACC)↗

Protective coating withstands high temperature in oxidizing atmosphere

Protective coating containing a plasma arc sprayed mixture of hafnium oxide and zirconium diboride will withstand high temperatures in an oxygen rich atmosphere. Used on a homogeneous tungsten thermocouple, it does not flake or crack on subsequent cooling and reheating, and does not degrade the thermocouple response time.

Mellor, C. H.↗

Heat flux sensor design reduces extraneous source effects

Heat flux sensor isolates the sensor and its transmitting thermocouple from undesirable heat sources by incorporating a radiator section that forms a radiation shield between mounting cup and sensor. Bonding of the thermocouple cable to the underside of the radiator provides a conductive path to dissipate extraneous heat that might otherwise reach the sensor.

Crofts, E. D.↗

Superconducting switch permits measurement of small voltages at cryogenic temperatures

Dual-coil, superconducting, on-off switch measures small, thermoelectrically generated voltages produced by thermocouples in a liquid helium bath. Placed in a shunt configuration between the thermocouple and the measuring device, the measuring device sees the sum of the voltage to be measured and the spurious thermoelectric voltages.

Govednik, R. E.↗

Space shuttle: Heat transfer rate measurements on Convair booster (B-15B-2) at nominal Mach number of 8

Plotted and tabulated data on heat transfer from a thin-skin thermocouple are presented. The data is representative of the reentry event of the booster alone configuration. The data were generated during wind tunnel tests of the B-15B-2 delta wing booster at Mach 8. Thermocouple measurements are reduced to heat transfer coefficient ratio and the data are presented as plotted variations versus longitudinal, lateral, and vertical local model positions.

Warmbrod, J. D.↗

Gas velocity and temperature near a liquid rocket injector face

The gas flow near the injector of a liquid propellant rocket was investigated by rapidly inserting butt-welded platinum-platinum rhodium thermocouples through the injector into the chamber. The transient responses of the thermocouples were analyzed to determine average gas temperatures and velocities. A method of fitting exponential curves to repeated measurements of the transient temperature at several positions near the injector face produced consistent results. Preliminary tests yielded gas flow directions and gas compositions at the injector face. Average gas temperatures were found to be between 3100 (1700) and 3500 F (1950 C) and the average gas velocities between 550 (170) and 840 feet/second (260 m/sec).

Boylan, D. M.↗

Apollo 15 measurement of lunar surface brightness temperatures - Thermal conductivity of the upper 1.5 meters of regolith.

In situ measurements of lunar surface brightness temperatures made as a part of the Apollo Lunar Surface Experiments Package at the Apollo 15 Hadley Rille landing site are reported. Data derived from five thermocouples of the Heat Flow Experiment, which are lying on or just above the surface, are used to examine the thermal properties of the upper 15 cm of the lunar regolith using eclipse and nighttime cool-down temperatures. Application of finite-difference techniques in modeling the lunar soil shows that the thermocouple data are best fit by a model consisting of a low-density and low-thermal conductivity surface layer approximately 2 cm thick overlying a region increasing in conductivity and density with depth. Conductivities on the order of 0.00001 W per cm per deg K are postulated for the upper layer, with conductivity increasing to the order of 0.0001 W per cm per deg K at depths exceeding 20 cm. An increase in mean temperature with depth indicates that the ratio of radiative to conductive transfer at 350 K is 2.7 for at least the upper few centimeters of lunar soil; this value is nearly twice that measured for returned lunar fines.

Keihm, S. J.↗

Surface brightness temperatures at the Apollo 17 heat flow site - Thermal conductivity of the upper 15 cm of regolith

Lunar surface brightness temperatures derived as part of the Apollo 17 heat flow experiment are reported. Nighttime surface temperatures, calculated from the data provided by two thermocouples suspended about 15 cm above the lunar surface, are used to determine the conductivity profile of the upper 15 cm of regolith at the ALSEP site. The surface reaches a maximum temperature of 384 (plus or minus 6) K at lunar noon and cools to a minimum temperature of 102 (plus or minus 1.5 K) at the end of the lunar night. Conductivities of the order of .000015 W/cm-deg K are postulated for a 2-cm porous surface layer overlying more compact regolith material with conductivities in the range of .0001 to .00015 W/cm-deg K between 2 and 15 cm. A mean surface temperature of 216 (plus or minus 5) K is deduced from the thermocouple data. The 256 K temperature measured by the probe sensors at 130 cm thus indicates that a large mean temperature gradient exists at the Apollo 17 site.

Keihm, S. J.↗

Analysis of a Pneumatic Probe for Measuring Exhaust-Gas Temperatures with Some Preliminary Experimental Results

A pneumatic probe based on continuity of mass flow through two restrictions separated by a cooling chamber was constructed to measure gas temperature at and beyond the limit of thermocouples. This probe consisted of a subsonic flat-plate orifice for the first restriction and a sonic-flow converging-diverging nozzle for the second restriction. The effect of variation in gas constants on the calibration is examined for common engine-exhaust gases. A high-temperature wind tunnel that allowed calibration of the probe at temperatures up to 2000 deg R and. Mach numbers up to 0.8 is described. Agreement to better than 30 deg R between pneumatic probe indication and the indication of a rake of radiation shielded thermocouples indicates that extrapolation of the calibration to higher temperatures is possible with fair accuracy

Scadron, Marvin D.↗

Forearm blood flow during body temperature transients produced by leg exercise

Subjects exercised for 30 min on a bicycle ergometer at 30, 50, and 70% of maximal aerobic power in ambient temperatures of 15, 25, and 35 C and vapor pressures of less than 18 torr. Exercise was used to vary internal temperature during an experiment, and different ambient temperatures were used to vary skin temperatures independently of internal temperature. Forearm skin temperature was fixed at about 36.5 C. Esophageal temperature was measured with a thermocouple at the level of the left atrium, and mean skin temperature was calculated from a weighted mean of thermocouple temperatures at eight skin sites. Forearm blood flow was measured by electrocapacitance plethysmography. Data are well accounted for by a linear equation independent of exercise intensity, although some subjects showed an equivocal vasodilator effect of exercise.

Wenger, C. B.↗

Thermoregulatory control of finger blood flow

In the present experiment, exercise was used to vary internal temperature and ambient air heat control was used to vary skin temperature. Finger temperature was fixed at about 35.7 C. Esophageal temperature was measured with a thermocouple at the level of the left atrium, and mean skin temperature was calculated from a weighted mean of thermocouple temperatures at different skin sites. Finger blood flow was measured by electrocapacitance plethysmography. An equation in these quantities is given which accounts for the data garnered.

Wenger, C. B.↗

Results of aerodynamic heat transfer tests of a 0.0175-scale model of the Rockwell International Space Shuttle Orbiter 139 (model number 22-0) in the NASA/Ames 3.5-foot hypersonic wind tunnel (test OH6)

The results of a hypersonic wind tunnel test program conducted using a 0.0175 scale thin-skin thermocouple model of the Space Shuttle Orbiter to obtain aerodynamic heat transfer data on the Orbiter under simulated reentry conditions were presented. The test program was conducted at a Mach number of 7.3 and a freestream Reynolds number ranging between 1.0 and 6.0 million/foot. The model was tested for angles of attack ranging between 10 deg and 30 deg and a sideslip angle of 0 deg. The model was constructed of 15-5 PH stainless steel with the instrumented areas machined to a nominal skin thickness of 0.030 in. The model instrumentation consisted of 288 iron-constantan thermocouples spot welded to the skin inner surface, but only 75 of these were used in this test program. A high-speed, analog-to-digital data acquisition system was used to record data on magnetic tape.

Dye, W. H.↗

Shock interference peak heating measurements using phase change coatings

The phase change coating technique is used to obtain peak heating measurements in shock interference flow regions with high surface shear and heating. This technique provides heat transfer coefficients which are determined by measuring the time for a point on the surface to reach the phase change temperature of the thin fusible coating. Measurements were conducted on a 5.08-cm diameter hemisphere-cylinder made of silica based epoxy at Mach 6 for free stream Reynolds numbers of 3.3 to 25.6 million per meter. A sketch of the shock interference pattern produced by a flat plate shock generator is included. Heating data obtained on a 5.08-cm diameter stainless steel hemispherical model instrumented with thermocouples is presented for the purpose of comparing the phase change technique with the thermocouple-calorimeter technique.

Keyes, J. W.↗