Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEST METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Rapid Assessment of Sulfate Resistance in Mortar and Concrete

Extensive research has been conducted on the sulfate attack of concrete structures; however, the need to adopt the use of more sustainable materials is driving a need for a quicker test method to assess sulfate resistance. This work presents accelerated methods that can reduce the time required for assessing the sulfate resistance of mixtures by 70%. Class F fly ash has historically been used in concrete mixtures to improve sulfate resistance. However, environmental considerations and the evolving energy industry have decreased its availability, requiring the identification of economically viable and environmentally friendly alternatives to fly ash. Another challenge in addressing sulfate attack durability issues in concrete is that the standard sulfate attack test (ASTM C1012) is time-consuming and designed for only standard mortars (not concrete mixtures). To expedite the testing process, accelerated testing methods for both mortar and concrete mixtures were adopted from previous work to further the development of the accelerated tests and to assess the feasibility of testing the sulfate resistance of mortar and concrete mixtures rapidly. This study also established criteria for interpreting sulfate resistance for each of the test methods used in this work. A total of 14 mortar mixtures and four concrete mixtures using two types of Portland cement (Type I and Type I/II) and various supplementary cementitious materials (SCMs) were evaluated in this study. The accelerated testing methods significantly reduced the evaluation time from 12 months to 21 days for mortar mixtures and from 6 months to 56 days for concrete mixtures. The proposed interpretation method for mortar accelerated test results showed acceptable consistency with the ACI 318-19 interpretations for ASTM C1012 results. The interpretation methods proposed for the two concrete sulfate attack tests demonstrated excellent consistency with the ASTM C1012 results from mortar mixtures with the same cementitious materials combinations. Metakaolin was shown to improve sulfate resistance for both mortar and concrete mixtures, while silica fume and natural pozzolan had a limited impact. Using 15% metakaolin in mortar or concrete mixtures with Type I/II cement provided the best sulfate resistance.

Chemistry↗

Adaptive flutter suppression, analysis and test

Methods of adaptive control have been applied to suppress a potentially violent flutter condition of a half-span model of a lightweight figher aircraft. This marked the confluence of several technologies with active flutter suppression, digital control and adaptive control theory the primary contributors. The control algorithm was required to adapt both to slowly varying changes, corresponding to changes in the flight condition or fuel loading and to rapid changes, corresponding to a store release or the transition from a stable to an unstable flight condition. The development of the adaptive control methods was followed by a simulation and checkout of the complete system and a wind tunnel demonstration. As part of the test, a store was released from the model wing tip, transforming the model abruptly from a stable configuration to a violent flutter condition. The adaptive algorithm recognized the unstable nature of the resulting configuration and implemented a stabilizing control law in a fraction of a second. The algorithm was also shown to provide system stability over a range of wind tunnel Mach numbers and dynamic pressures.

Johnson, E. H.↗

High-precision Non-Contact Measurement of Creep of Ultra-High Temperature Materials for Aerospace

For high-temperature applications (greater than 2,000 C) such as solid rocket motors, hypersonic aircraft, nuclear electric/thermal propulsion for spacecraft, and more efficient jet engines, creep becomes one of the most important design factors to be considered. Conventional creep-testing methods, where the specimen and test apparatus are in contact with each other, are limited to temperatures approximately 1,700 C. Development of alloys for higher-temperature applications is limited by the availability of testing methods at temperatures above 2000 C. Development of alloys for applications requiring a long service life at temperatures as low as 1500 C, such as the next generation of jet turbine superalloys, is limited by the difficulty of accelerated testing at temperatures above 1700 C. For these reasons, a new, non-contact creep-measurement technique is needed for higher temperature applications. A new non-contact method for creep measurements of ultra-high-temperature metals and ceramics has been developed and validated. Using the electrostatic levitation (ESL) facility at NASA Marshall Space Flight Center, a spherical sample is rotated quickly enough to cause creep deformation due to centrifugal acceleration. Very accurate measurement of the deformed shape through digital image analysis allows the stress exponent n to be determined very precisely from a single test, rather than from numerous conventional tests. Validation tests on single-crystal niobium spheres showed excellent agreement with conventional tests at 1985 C; however the non-contact method provides much greater precision while using only about 40 milligrams of material. This method is being applied to materials including metals and ceramics for non-eroding throats in solid rockets and next-generation superalloys for turbine engines. Recent advances in the method and the current state of these new measurements will be presented.

Rogers, Jan R.↗

Analysis of International Space Station Materials on MISSE-3 and MISSE-4

For high-temperature applications (> 2,000 C) such as solid rocket motors, hypersonic aircraft, nuclear electric/thermal propulsion for spacecraft, and more efficient jet engines, creep becomes one of the most important design factors to be considered. Conventional creep-testing methods, where the specimen and test apparatus are in contact with each other, are limited to temperatures ~1,700 deg. C. Development of alloys for higher-temperature applications is limited by the availability of testing methods at temperatures above 2000 C. Development of alloys for applications requiring a long service life at temperatures as low as 1500 C, such as the next generation of jet turbine superalloys, is limited by the difficulty of accelerated testing at temperatures above 1700 0c. For these reasons, a new, non-contact creep-measurement technique is needed for higher temperature applications. A new non-contact method for creep measurements of ultra-high-temperature metals and ceramics has been developed and validated. Using the electrostatic levitation (ESL) facility at NASA Marshall Space Flight Center, a spherical sample is rotated quickly enough to cause creep deformation due to centrifugal acceleration. Very accurate measurement of the deformed shape through digital image analysis allows the stress exponent n to be determined very precisely from a single test, rather than from numerous conventional tests. Validation tests on single-crystal niobium spheres showed excellent agreement with conventional tests at 1985 C; however the non-contact method provides much greater precision while using only about 40 milligrams of material. This method is being applied to materials including metals and ceramics for noneroding throats in solid rockets and next-generation superalloys for turbine engines. Recent advances in the method and the current state of these new measurements will be presented.

Finckenor, Miria M.↗

High-temperature testing of glass/ceramic matrix composites

Recent advances in ceramic and other high-temperature composites have created a need for test methods that can be used at 1000 C and above. Present test methods usually require adhesively bonded tabs that cannot be used at high temperatures. This paper discusses some of the difficulties with high-temperature test development and describes several promising test methods. Stress-strain data are given for Nicalon ceramic fiber reinforced glass and glass-ceramic matrix composites tested in air at temperatures up to 1000 C.

Mandell, John F.↗

Bulk Electrical Cable Non-Destructive Examination Methods for Nuclear Power Plant Cable Aging Management Programs

This Pacific Northwest National Laboratory milestone report describes progress to date on the investigation of nondestructive test methods focusing particularly on bulk electrical test methods that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As nuclear power plants consider applying for second, or subsequent, license renewal to extend their operating period from 60 years to 80 years, it is important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program, however, is directed toward the more demanding challenge of assuring the cable function under accident or DBE. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB, however, is a destructive test so the test programs must apply an array of other nondestructive examination (NDE) tests to assure or infer the overall set of cable’s system integrity. Assessment of cable integrity is further complicated in many cases by vendor’s use of dissimilar material for jacket and insulation. Frequently the jacket will degrade more rapidly than the underlying insulation. Although this can serve as an early alert to cable damage, direct test of the cable insulation without violating the protective jacket becomes problematic. This report addresses the range of bulk electrical NDE cable tests that are or could be practically implemented in a field-test situation with a particular focus on frequency domain reflectometry (FDR). The FDR test method offers numerous advantages over many other bulk electrical tests. Two commercial FDR systems plus a laboratory vector network analyzer are used to test an array of aged and un-aged cables under identical conditions. Several conclusions are set forth, and a number of knowledge gaps are identified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Utilization of Advanced Composites in Military Aircraft

The purpose of this workshop was to identify the current state of the art in key issues related to compression loading and fluid effects in composite materials. In the area of compression loading, there was considerable concern over the different results obtained from various test methods. It was agreed that failure modes produced by the various test methods along with a better fundamental understanding of compression failure were key issues in the development of compression test methods. In the area of fluid effects, a lack of a comprehensive data base hampers identification of key mechanisms leading to fluid degradation. This is further complicated by the fact that interactions depend on the fluid and composite under consideration.

Advisory Group for Aerospace Research and Developm↗

Centaur feedline dynamics study using power spectral methods

Tests were conducted to determine the dynamic characteristics of the Centaur/RL-10 oxygen and hydrogen feedlines. The fundamental-mode resonant frequencies were determined by applying power spectral methods to noise-generated data from hot firings of the RL-10 engine. The effect of net positive suction pressure of the main feed pumps on resonant frequency characteristics was determined to be a straight-line relation. Power spectral methods were also used to determine the dynamic characteristics of the boost pumps.

Lorenzo, C. F.↗

Test Methodology to Evaluate the Safety of Materials Using Spark Incendivity

For many years scientists and engineers have been searching for the proper test method to evaluate an electrostatic risk for materials used in hazardous environments. A new test standard created by the International Electrotechnical Commission is a promising addition to conventional test methods used throughout industry. The purpose of this paper is to incorporate this test into a proposed new methodology for the evaluation of materials exposed to flammable environments. However, initial testing using this new standard has uncovered some unconventional behavior in materials that conventional test methods were thought to have reconciled. For example some materials tested at higher humidities were more susceptible to incendive discharges than at lower humidity even though the surface resistivity was lower.

Buhler, Charles↗

Duct Leakage Repeatability Testing

The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Existing and Past Methods of Test and Rating Standards Related to Integrated Heat Pump Technologies

This report evaluates existing and past US methods of test and rating standards related to electrically operated air, water, and ground source air conditioners and heat pumps, 65,000 Btu/hr and under in capacity, that potentiality incorporate a potable water heating function. Two AHRI (formerly ARI) standards and three DOE waivers were identified as directly related. Six other AHRI standards related to the test and rating of base units were identified as of interest, as they would form the basis of any new comprehensive test procedure. Numerous other AHRI and ASHRAE component test standards were also identified as perhaps being of help in developing a comprehensive test procedure.

Reedy, Wayne R.↗

Space Suit Joint Torque Measurement Method Validation

In 2009 and early 2010, a test method was developed and performed to quantify the torque required to manipulate joints in several existing operational and prototype space suits. This was done in an effort to develop joint torque requirements appropriate for a new Constellation Program space suit system. The same test method was levied on the Constellation space suit contractors to verify that their suit design met the requirements. However, because the original test was set up and conducted by a single test operator there was some question as to whether this method was repeatable enough to be considered a standard verification method for Constellation or other future development programs. In order to validate the method itself, a representative subset of the previous test was repeated, using the same information that would be available to space suit contractors, but set up and conducted by someone not familiar with the previous test. The resultant data was compared using graphical and statistical analysis; the results indicated a significant variance in values reported for a subset of the re-tested joints. Potential variables that could have affected the data were identified and a third round of testing was conducted in an attempt to eliminate and/or quantify the effects of these variables. The results of the third test effort will be used to determine whether or not the proposed joint torque methodology can be applied to future space suit development contracts.

Valish, Dana↗

Comparison of the mouse Embryonic Stem cell Test, the rat Whole Embryo Culture and the Zebrafish Embryotoxicity Test as alternative methods for developmental toxicity testing of six 1,2,4-triazoles

The relatively high experimental animal use in developmental toxicity testing has stimulated the search for alternatives that are less animal intensive. Three widely studied alternative assays are the mouse Embryonic Stem cell Test (EST), the Zebrafish Embryotoxicity Test (ZET) and the rat postimplantation Whole Embryo Culture (WEC). The goal of this study was to determine their efficacy in assessing the relative developmental toxicity of six 1,2,4-triazole compounds, flusilazole, hexaconazole, cyproconazole, triadimefon, myclobutanil and triticonazole. For this purpose, we analyzed effects and relative potencies of the compounds in and among the alternative assays and compared the findings to their known in vivo developmental toxicity. Triazoles are antifungal agents used in agriculture and medicine, some of which are known to induce craniofacial and limb abnormalities in rodents. The WEC showed a general pattern of teratogenic effects, typical of exposure to triazoles, mainly consisting of reduction and fusion of the first and second branchial arches, which are in accordance with the craniofacial malformations reported after in vivo exposure. In the EST all triazole compounds inhibited cardiomyocyte differentiation concentration-dependently. Overall, the ZET gave the best correlation with the relative in vivo developmental toxicities of the tested compounds, closely followed by the EST. The relative potencies observed in the WEC showed the lowest correlation with the in vivo developmental toxicity data. These differences in the efficacy between the test systems might be due to differences in compound kinetics, in developmental stages represented and in the relative complexity of the alternative assays.

60 APPLIED LIFE SCIENCES↗

Decoding Early Candidacy of High Entropy Alloys for Nuclear Application using the Advanced Test Reactor through Predictive Methods and Combinatorial Testing

High Entropy Alloys (HEAs) are identified candidates for nuclear applications owing to their superb mechanical and thermal properties. In line with evaluating their candidacy, a challenge remains in their validity as structural replacements for extreme environments. Each compositional graded specimen consists up to four different compositions spanning the fueled zone for non-prototypical neutron irradiation testing in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). We have fabricated a set of four compositionally graded specimens using spark plasma sintering that include at least five of the following elements: Cr, C, Al, Zr, Mo, Nb, Ta, V, Ti, W, and Fe. In time for this meeting the role of temperature expected to play a role in-pile cladding chemical interactions (FCCI), mechanical interactions (FCMI), irradiation damage, creep, and resistance will be reported. The irradiated portion has a scheduled irradiation date in April 2020 and with post irradiation examination (PIE) to follow.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Proposed Objective Odor Control Test Methodology for Waste Containment

The Orion Cockpit Working Group has requested that an odor control testing methodology be proposed to evaluate the odor containment effectiveness of waste disposal bags to be flown on the Orion Crew Exploration Vehicle. As a standardized "odor containment" test does not appear to be a matter of record for the project, a new test method is being proposed. This method is based on existing test methods used in industrial hygiene for the evaluation of respirator fit in occupational settings, and takes into consideration peer reviewed documentation of human odor thresholds for standardized contaminates, industry stardnard atmostpheric testing methodologies, and established criteria for laboratory analysis. The proposed methodology is quantitative, though it can readily be complimented with a qualitative subjective assessment. Isoamyl acetate (IAA - also known at isopentyl acetate) is commonly used in respirator fit testing, and there are documented methodologies for both measuring its quantitative airborne concentrations. IAA is a clear, colorless liquid with a banana-like odor, documented detectable smell threshold for humans of 0.025 PPM, and a 15 PPB level of quantation limit.

Vos, Gordon↗

Fracture Mechanics Testing of Titanium 6AL-4V in LMP-103S Propellant

Propellant tank safe-life analysis is a spacecraft propulsion subsystem Launch Range processing requirement. The material property inputs for the safe-life analysis include the stress intensity factor for environment-assisted cracking (KEAC). The KEAC for titanium alloy Ti 6Al-4V in LMP-103S propellant was determined experimentally using an innovative test method following ASTM E1681, Standard Test Method for Determining Threshold Stress Intensity Factor for Environment-Assisted Cracking of Metallic Materials. This effort was a collaboration between NASA Goddard Space Flight Center and NASA Kennedy Space Center to expose the test specimens in the propellant, while loaded in the test fixtures, for 1000- hour (42 days) at 50°C. Two test rounds have been completed to date; 1) testing mechanically loaded specimens but without propellant and 2) testing mechanically loaded specimens wetted with LMP-103S propellant. The dry test was to evaluate the crack growth without exposure to the LMP-103S propellant, and further assess the un-wetted stress intensity factor for the full 1000-hour duration. The second round of testing included the propellant soak for the requisite 1000- hour at 50°C. Current results show that the threshold intensity factor for environment-assisted cracking (exposed to LMP103S) is 22.5 ksi√in for the bulk material and 36. 2 ksi√in for the weld material. A generic ‘candidate’ tank geometry and material thickness is developed for a damage tolerance of known surface cracks below the nondestructive inspection technique detection limit. Evaluations with and without the use of a threshold intensity factor for environment-assisted cracking is performed for the required 4x propellant tank service life using the software tool NASGRO. SP2024_00239

Green propulsion↗

Method for obtaining aerodynamic data on hypersonic configurations with scramjet exhaust flow simulation

A hypersonic wind tunnel test method for obtaining credible aerodynamic data on a complete hypersonic vehicle (generic X-24c) with scramjet exhaust flow simulation is described. The general problems of simulating the scramjet exhaust as well as accounting for scramjet inlet flow and vehicle forces are analyzed, and candidate test methods are described and compared. The method selected as most useful makes use of a thrust-minus-drag flow-through balance with a completely metric model. Inlet flow is diverted by a fairing. The incremental effect of the fairing is determined in the testing of two reference models. The net thrust of the scramjet module is an input to be determined in large-scale module tests with scramjet combustion. Force accounting is described, and examples of force component levels are predicted. Compatibility of the test method with candidate wind tunnel facilities is described, and a preliminary model mechanical arrangement drawing is presented. The balance design and performance requirements are described in a detailed specification. Calibration procedures, model instrumentation, and a test plan for the model are outlined.

Hartill, W. R.↗

Quality Control in Fast Pyrolysis Bio-Oil Production and Use

This paper will focus on norms and standards for fast pyrolysis bio-oils. It will include the present status and address what still has to be done on bio-oil specifications and relevant test methods. The paper will address industrial needs in commercialization of the fuel oil use of bio-oil, including the registration application to the REACH program and its consequences within the European Union, as well as development of a standard within ASTM. The paper will discuss the most important properties of bio-oil and the variation in these properties among various bio-oils. It will address the issue of quality follow-up in bio-oil production, including the properties to be followed and the laboratory and on-line monitoring methods. The paper will provide a state of the art of fuel oil specifications, test methods, and testing procedures as they are applied to bio-oil. It will review the effort in support of the implementation of an ASTM standard including the methods validation work.

02 PETROLEUM↗