At least 505 records · Page 28

Rossi-alpha Analysis of CURIE Experiment [Slides]

Critical assembly measurement and operations are crucial to the development of benchmark data. Knowledge of the prompt neutron lifetime informs on the state of the system’s neutron spectrum. Rossi-alpha analysis can give us time-dependent information on the system. Teflon was selected, via genetic algorithm, as a moderator to target the URR in uranium for CURIE. Rossi-alpha measurements of the assembly's approach to critical using He-3 detectors estimated the prompt neutron decay constant (α) at delayed critical. α values of several subcritical measurements were then used to predict the α value at delayed critical.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE ROLL-OVER OF HELIOSPHERIC NEUTRAL HYDROGEN BELOW 100 eV: OBSERVATIONS AND IMPLICATIONS

We present an improved analysis of the energy spectrum of energetic neutral hydrogen from the heliosheath observed with the IBEX -Lo sensor on the Interstellar Boundary EXplorer from the years 2009 to 2012. This analysis allows us to study the lowest energies between 10 and 100 eV although various background sources are more intense than the targeted signal over broad areas of the sky. The results improve our knowledge of the interaction region between our heliosphere and the interstellar plasma because these neutral atoms are direct messengers from the low-energy plasma in the heliosheath. We find a roll-over of the energy spectrum below 100 eV, which has major implications for the pressure balance of the plasma in the inner heliosheath. The results can also be compared directly with in situ observations of the Voyager 1 and 2 spacecraft.

79 ASTRONOMY AND ASTROPHYSICS↗

Charge exchange spectroscopy as a fast ion diagnostic on TEXTOR

An upgraded charge exchange spectroscopy diagnostic has been taken into operation at the TEXTOR tokamak. The angles of the viewing lines with the toroidal magnetic field are close to the pitch angles at birth of fast ions injected by one of the neutral beam injectors. Using another neutral beam for active spectroscopy, injected counter the direction in which fast ions injected by the first beam are circulating, we can simultaneously measure a fast ion tail on the blue wing of the D{sub {alpha}} spectrum while the beam emission spectrum is Doppler shifted to the red wing. An analysis combining the two parts of the spectrum offers possibilities to improve the accuracy of the absolute (fast) ion density profiles. Fast beam modulation or passive viewing lines cannot be used for background subtraction on this diagnostic setup and therefore the background has to be modeled and fitted to the data together with a spectral model for the slowing down feature. The analysis of the fast ion D{sub {alpha}} spectrum obtained with the new diagnostic is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-resolution anisotropy studies of ultrahigh-energy cosmic rays detected at the Pierre Auger Observatory

Here, we report a multi-resolution search for anisotropies in the arrival directions of cosmic rays detected at the Pierre Auger Observatory with local zenith angles up to 80(o) and energies in excess of 4 EeV (4 × 10 18 eV). This search is conducted by measuring the angular power spectrum and performing a needlet wavelet analysis in two independent energy ranges. Both analyses are complementary since the angular power spectrum achieves a better performance in identifying large-scale patterns while the needlet wavelet analysis, considering the parameters used in this work, presents a higher efficiency in detecting smaller-scale anisotropies, potentially providing directional information on any observed anisotropies. No deviation from isotropy is observed on any angular scale in the energy range between 4 and 8 EeV. Above 8 EeV, an indication for a dipole moment is captured, while no other deviation from isotropy is observed for moments beyond the dipole one. The corresponding p-values obtained after accounting for searches blindly performed at several angular scales, are 1.3 × 10 -5 in the case of the angular power spectrum, and 2.5 × 10 -3 in the case of the needlet analysis. While these results are consistent with previous reports making use of the same data set, they provide extensions of the previous works through the thorough scans of the angular scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparison of Direct Sequence Spread Spectrum Rake Receiver with a Maximum Ratio Combining Multicarrier Spread Spectrum Receiver

This paper presents a theoretical analysis of the performance of a filter bank-based multicarrier spread spectrum (FB-MC-SS) system. We consider an FB-MC-SS setup where each data symbol is spread across multiple subcarriers, but there is no spreading in time. The results are then compared with those of the well-known direct sequence spread spectrum (DS-SS) system with a rake receiver for its best performance. We compare the two systems when the channel noise is white. We prove that as the processing gains of the two systems tend to infinity both approach the same performance. However, numerical simulations show that, in practice, where processing gain is limited, FB-MC-SS outperforms DS-SS.

99 GENERAL AND MISCELLANEOUS↗

Quantifying Polaron Mole Fractions and Interpreting Spectral Changes in Molecularly Doped Conjugated Polymers

Molecular doping of conjugated polymers causes bleaching of the neutral absorbance and results in new polaron absorbance transitions in the mid and near infrared. In this report the concentration dependent changes in the spectra for a series of molecularly doped diketopyrrolopyrrole (DPP) co-polymers with a series of ultra-high electron affinity cyanotrimethylenecyclopropane-based dopants is analyzed. With these strong dopants the polaron mole fraction (Θ) reaches saturation. Analysis of the full spectrum enables separation of neutral and polaron signals and quantification of the polaron mole fraction using a simple noninteracting site model. The peak ratios for both neutral and polaron peaks change systematically with increasing polaron mole fraction for all measured polymers. Analysis of the spectral changes indicates that the polaron mole fraction can be quantified to within 5%. While the total change in the absorbance spectrum with increasing polaron mole fraction is linear, the lowest energy polaron peak (P1) grows nonlinearly, which indicates increased polarization/delocalization. Molecular doping of polymers that form either H- or J-aggregates shows systematically different spectral changes in the vibronic peak ratios of the neutral spectra and provides insights into the polymer configuration at undoped sites in the film.

36 MATERIALS SCIENCE↗

Photoelectron Spectroscopy Study of Quinonimides

Structures and energetics of o-, m- and p-quinonimide anions (OC6H4N) and quinoniminyl radicals have been investigated by using negative ion photoelectron spectroscopy. Modeling of the photoelectron spectrum of the ortho isomer shows that the ground state of the anion is a triplet, while the quinoniminyl radical has a doublet ground state with a doublet-quartet splitting of 35.5 kcal/mol. The para radical has doublet ground state, but a band for a quartet state is missing from the photoelectron spectrum indicating that the anion has a singlet ground state, in contrast to previously reported calculations. The theoretical modeling is revisited here, and it is shown that accurate predictions for the electronic structure of the para quinonimide anion require both an accurate account of electron correlation and a sufficiently diffuse basis set. Electron affinities of o- and p-quinoniminyl radicals are measured to be 1.715 ± 0.010 and 1.675 ± 0.010 eV, respectively. The photoelectron spectrum of the m-quinonimide anion shows that the ion undergoes several different rearrangements, including a rearrangement to the energetically favorable para isomer. Such rearrangements preclude a meaningful analysis of the experimental spectrum.

Environmental Molecular Sciences Laboratory↗

Analysis of Radiological Release From Fueled Irradiation Experiments During Manual Handling (Slides)

Irradiation experiments are manually handled at the Advanced Test Reactor (ATR) by qualified operators using long handled tools. Standard handling evolutions include insertion and removal from the reactor vessel, transfer to/from a storage location or cask in the ATR canal, and handling/reconfigurations at a canal working tray. Such routine handling has the potential to result in mechanical damage to the experiment boundary which is credited to retain fission products. Since damage can occur due to operator error, this is an anticipated occurrence. This work determines the radiological consequences to receptors inside the ATR facility, as well as public receptors. Given the wide variety of fuel types tested at the ATR, a generic approach to the analysis is taken. The radiological inventory is determined to bound a variety of fuel types (e.g., ceramic and molten fuel matrices) and fission powers on the U-235 enrichment spectrum. The source term analysis considers different release fractions to bound different fuel types and burnups. The postulated handling events occur underwater; thus, retention of the released isotopic content is considered within the canal water column. Retention of radionuclides in the water column is determined using a modified approach of United States (US) Nuclear Regulatory Commission (NRC) Regulatory Guide (RG) 1.183. Radiological dose to the facility receptor is determined using a compartment release model. Dose to the public receptor is determined using atmospheric dispersion models using site specific atmospheric conditions with the use of the Radiological Safety Analysis Computer (RSAC) program version 7.2.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

PRINCIPAL COMPONENT ANALYSIS STUDIES OF TURBULENCE IN OPTICALLY THICK GAS

In this work we investigate the sensitivity of principal component analysis (PCA) to the velocity power spectrum in high-opacity regimes of the interstellar medium (ISM). For our analysis we use synthetic position–position–velocity (PPV) cubes of fractional Brownian motion and magnetohydrodynamics (MHD) simulations, post-processed to include radiative transfer effects from CO. We find that PCA analysis is very different from the tools based on the traditional power spectrum of PPV data cubes. Our major finding is that PCA is also sensitive to the phase information of PPV cubes and this allows PCA to detect the changes of the underlying velocity and density spectra at high opacities, where the spectral analysis of the maps provides the universal −3 spectrum in accordance with the predictions of the Lazarian and Pogosyan theory. This makes PCA a potentially valuable tool for studies of turbulence at high opacities, provided that proper gauging of the PCA index is made. However, we found the latter to not be easy, as the PCA results change in an irregular way for data with high sonic Mach numbers. This is in contrast to synthetic Brownian noise data used for velocity and density fields that show monotonic PCA behavior. We attribute this difference to the PCA's sensitivity to Fourier phase information.

79 ASTRONOMY AND ASTROPHYSICS↗

The analysis of shape data including normalization and the impact on prompt fission neutron spectrum measurements

While measurements of physical quantities contain an intrinsic absolute scale based on details of the experiment, sometimes only the value of each measured data point relative to the others, i.e., the shape, is of interest. Additionally, in contrast to absolute measurements of quantities like nuclear cross sections, shape measurements are unique in that the result is contained entirely in the relative value of each measured point with respect to all others. This fundamental attribute of shape data is sometimes discussed by data evaluators, but it is common that shape data are reported by experimenters with covariances directly from the raw data as though an absolute measurement has been performed, thereby misrepresenting the true knowledge of the measured shape. A normalization procedure must be carried out including careful covariance propagation in order to accurately represent the uncertainty in a measured shape. Known consequences of this procedure, such as the exclusion of constant fully-correlated uncertainties, are sometimes applied ad hoc to shape data. However, normalization also produces features of shape data that are otherwise difficult to apply, such as partial exclusion of strongly-correlated uncertainty sources, a redistribution of uncertainties across data points, and consistency of the covariance matrix obtained when combining separate shape measurements. In this study all of the above features are shown in a generalized fashion and exhibited using prompt fission neutron spectrum data from the Chi-Nu experiment with recommendations for analysis of future shape measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reanalysis of the Aqueous Spectrum of the Neptunyl(V) [NpO 2 + ] Ion

The actinyl ions, consisting of the dioxoactinde(VI) and dioxoactinide(V) ions, are unique in the periodic table. However, very few quantitative studies of the spectra of these ions have been performed. In this paper the analysis of the optical spectrum of the aqueous neptunyl(V) [NpO 2 + ] ion in 1 M HClO 4 is reexamined. The species in solution is assumed to be the linear NpO 2 + ion surrounded in the equatorial plane by five oxygen atoms from five H 2 O molecules. The neptunyl(V) ion has the 5f 2 open-shell configuration, and the low-lying optical transitions (up to 20 000 cm -1 ) observed are primarily from the two 5f electrons occupying the 5f and 5fφ orbitals. The conventional parametric theory used for f n systems is applied to these low-lying transitions utilizing the intensity calculations that Matiska et al.1 have performed for this ion and the data reported by Eisenstein and Pryce.2 Possible ratios for the Slater electrostatic repulsion parameters are obtained from the data for the isoelectronic ion U 4+ (5f 2 ) in various host crystals. The results are consistent with previous crystal field analyses of the 5f 1 neptunyl(VI) [NpO 2 + ] ion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracking the evolution of quasi-periodic oscillation in RE J1034+396 using the Hilbert-Huang transform

RE J1034+396, a narrow-line Seyfert 1 active galactic nucleus (AGN), is the first example of AGNs that exhibited a nearly coherent quasi-periodic oscillation (QPO) for the data collected by XMM-Newton in 2007. The spectral behaviors and timing properties of the QPO have been studied since its discovery. We present an analysis of the QPO in RE J1034+396 based on the Hilbert-Huang transform. Comparing with other time-frequency analysis methods, the Hilbert spectrum reveals the variation of the QPO period in great detail. Furthermore, the empirical mode decomposition provides bandpass-filtered data that can be used in the O – C and correlation analysis. We suggest that it is better to divide the evolution of the QPO in this observation into three epochs according to their different periodicities. In addition to the periodicities, the correlations between the QPO periods and corresponding mean count rates are also different in these three epochs. Further examining the phase lags in these epochs, we found no significant phase lags between the soft and hard X-ray bands, which is also confirmed in the QPO phase-resolved spectral analysis. Finally, we discuss the indications of current models including a spotted accretion disk, diskoseismology, and oscillation of shock according to the observed time-frequency and spectral behaviors.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of the S{sub 2}←S{sub 0} vibronic spectrum of the ortho-cyanophenol dimer using a multimode vibronic coupling approach

The S{sub 2}←S{sub 0} vibronic spectrum of the ortho-cyanophenol dimer (oCP){sub 2} is analyzed in a joint experimental and theoretical investigation. Vibronic excitation energies up to 750 cm{sup −1} are covered, which extends our previous analysis of the quenching of the excitonic splitting in this and related species [Kopec et al., J. Chem. Phys. 137, 184312 (2012)]. As we demonstrate, this necessitates an extension of the coupling model. Accordingly, we compute the potential energy surfaces of the ortho-cyanophenol dimer (oCP){sub 2} along all relevant normal modes using the approximate second-order coupled cluster method RI-CC2 and extract the corresponding coupling constants using the linear and quadratic vibronic coupling scheme. These serve as the basis to calculate the vibronic spectrum. The theoretical results are found to be in good agreement with the experimental highly resolved resonant two-photon ionization spectrum. This allows to interpret key features of the excitonic and vibronic interactions in terms of nodal patterns of the underlying vibronic wave functions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved photoluminescence property of CTAB assisted polyaniline-AlZnO nanocomposite

Polyaniline-Al doped ZnO ((PANI-AlZnO:: 70:30) nanocomposite was prepared via in situ chemical oxidative polymerization, while the hexagonal powder of AlZnO was synthesized via sol-gel technique, using Hexadecyltrimethylammonium bromide (CTAB) as a capping agent. The prepared nanocomposite was characterized by High resolution transmission electron microscopy (HRTEM), EDAX, X-ray diffraction (XRD) and Fourier transforms infrared (FTIR) spectra. The optical property of the nanomaterials is examined by photoluminescence (PL) spectra analysis. The XRD pattern confirms the formation of Al doped ZnO as well as PANI. The HRTEM images of the composite showed the formation of hexagonal AlZnO embedded in polyaniline matrix. EDAX spectrum shows the compositional analysis of the nanocomposite. FTIR spectra confirm the formation of nanocomposite of PANI and hexagonal AlZnO. The PL intensity of the nanocomposite is improved as compared to pure AlZnO.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of the time-of-flight neutron scattering cross-section data for light water measured at the SEQUOIA spectrometer, Spallation Neutron Source (SNS)

Thermal neutron scattering cross-section data for light water available in the major nuclear data libraries observes significant differences especially at reactor operating temperatures. During the past few years there has been a renewed interest in reviewing the existing thermal scattering models and generating more accurate and reliable thermal scattering cross sections using existing experimental data and in some cases based on Molecular Dynamics (MD) simulations. There is a need for performing new time-of-flight experiments at high temperatures and pressures, to have a better understanding of the physics involved in the scattering process that could help improve the existing TSL data.Lack of experimental thermal scattering data for light water at high temperatures led to a new measurement campaign within the INSIDER project at the Institut de radioprotection et de sûreté nucléaire (IRSN). Double differential scattering cross section for light water have been measured at the SEQUOIA spectrometer based at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, United States. Several measurements have been carried out at different temperatures and pressures corresponding to liquid light water. Measurements at five different incident neutron energies Ei (8, 60, 160, 280 and 800 meV) have been carried out to help exploring different regions of the frequency spectrum. This paper presents the analysis of the dynamic structure factor and the derived frequency spectrum of light water. The analysis of the experimental data would provide one with better confidence, the behavior of thermal scattering cross sections for light water at high temperatures, knowledge of which is very important for the design of novel reactors as well as existing pressurized water reactors.

Jaiswal, V↗

Extracting the spectrum of a flow by spatial filtering

We show that the spectrum of a flow field can be extracted within a local region by straightforward filtering in physical space. We find that for a flow with a certain level regularity, the filtering kernel must have a sufficient number of vanishing moments in order for the "filtering spectrum" to be meaningful. Our derivation follows a similar analysis by [1] for the wavelet spectrum, where we show that the filtering kernel has to have at least p vanishing moments in order to correctly extract a spectrum k (-alpha) with (alpha) less/equal to p + 2. For example, any ow with a spectrum shallower than k (-3) can be extracted by a straightforward average on grid-cells of a stencil. We construct two new "simple stencil" kernels, MI and MII, with only two and three fixed stencil weight coefficients, respectively, and that have sufficient vanishing moments to allow for extracting spectra steeper than k(-3). We demonstrate our results using synthetic fields, 2D turbulence from a Direct Numerical Simulation, and 3D turbulence from the JHU Database. Our method guarantees energy conservation and can be useful in both simulations and experiments when a straightforward Fourier analysis is not justified, such as within coherent flow structures covering non-rectangular regions or in geophysical flows on Earth's curved surface.

42 ENGINEERING↗

In situ ultrahigh vacuum residual gas analyzer 'calibration'

Knowing the residual gas spectrum is essential for many applications and research in ultrahigh vacuum (UHV). Residual gas analyzers (RGAs) are used for both qualitative and quantitative gas analyses, where the quadrupole mass analyzers are now the most popular. It was found that RGAs supplied by different manufacturers are not necessarily well calibrated for quantitative gas analysis. A procedure applied for in situ RGA 'calibration' against a calibrated UHV total pressure gauge is described in this article. It was found that special attention should be paid to H{sub 2} calibration, as RGAs are usually much more sensitive to H{sub 2} than ionization gauges. The calibration coefficients are quite reproducible in Faraday cup mode, however, using the secondary electron multiplier requires frequent checks of the calibration coefficients. The coefficients obtained for the RGA allow the use of the RGA as an accurate device for gas spectrum analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Failure analysis of a cooling pump using modal and vibration analysis

Four pumps redundantly supply cooling water to a system. All four pumps underwent maintenance during a recently scheduled downtime. During preliminary evaluation following maintenance, one pump, the subject of this document, exhibited higher vibration levels compared to the other three pumps. The pump underwent further performance testing to rule out potential damage resulting from the higher vibration. Vibration analysis and modal analysis including steady state spectrum, operational deflection shape, run up transients, and modal impact have been utilized to identify dynamic characteristics that could contribute to the increased vibration levels. This article will cover the testing setup, methodology, analysis results, and recommendations.

42 ENGINEERING↗