Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Design and evaluation of executable assertions for concurrent error detection

System level concurrent detection of errors due to hardware faults can be accomplished by introducing software redundancy in the form of executable assertions into a program to monitor the correct operation of the system during its execution. This paper attempts to formalize the use of executable assertions for the purpose of concurrent error detection, and discusses a transformation approach to the design of assertion statements. The second part deals with the effectiveness of the error detection technique. A fault simulation method for the evaluation of the reliability of the assertion statements is described. This scheme was used to study the effectiveness of a nontrivial program in providing protection against faults in the underlying system. The experimental results shows that the use of executable assertions provides an effective approach to achieve concurrent error detection.

Hua, Kien A.↗

PIXiE: an algorithm for automated ion mobility arrival time extraction and collision cross section calculation using global data association

Abstract Motivation Drift tube ion mobility spectrometry coupled with mass spectrometry (DTIMS-MS) is increasingly implemented in high throughput omics workflows, and new informatics approaches are necessary for processing the associated data. To automatically extract arrival times for molecules measured by DTIMS at multiple electric fields and compute their associated collisional cross sections (CCS), we created the PNNL Ion Mobility Cross Section Extractor (PIXiE). The primary application presented for this algorithm is the extraction of data that can then be used to create a reference library of experimental CCS values for use in high throughput omics analyses. Results We demonstrate the utility of this approach by automatically extracting arrival times and calculating the associated CCSs for a set of endogenous metabolites and xenobiotics. The PIXiE-generated CCS values were within error of those calculated using commercially available instrument vendor software. Availability and implementation PIXiE is an open-source tool, freely available on Github. The documentation, source code of the software, and a GUI can be found at https://github.com/PNNL-Comp-Mass-Spec/PIXiE and the source code of the backend workflow library used by PIXiE can be found at https://github.com/PNNL-Comp-Mass-Spec/IMS-Informed-Library. Supplementary information Supplementary data are available at Bioinformatics online.

Ma, Jian↗

Computer-developed construction of analytic expressions for the coordinates and partial derivatives of Jupiter's Galilean satellites

A method for improving Sampson's (1910, 1912, 1921) original work in developing series expressions for accurate coordinates of the Galilean satellites is discussed. The method, which utilizes computer-based algebraic manipulation software, was developed to reconstruct Sampson's theory, remove existing errors, introduce neglected effects, and provide analytic expressions for the coordinates as well as for the partial derivatives with respect to orbital parameters, Jupiter's mass and oblateness, the satellite masses, and Jupiter's pole and rotation period. The software system, capable of handling Poisson series with up to 73 polynomial variables and 28 trigonometric arguments, is described. The preliminary solution is presented, and procedures are outlined for calculating perturbations and eliminating auxiliary parameters.

Lieske, J. H.↗

Experimental validation of equations for 2D DIC uncertainty quantification.

Uncertainty quantification (UQ) equations have been derived for predicting matching uncertainty in two-dimensional image correlation a priori. These equations include terms that represent the image noise and image contrast. Researchers at the University of South Carolina have extended previous 1D work to calculate matching errors in 2D. These 2D equations have been coded into a Sandia National Laboratories UQ software package to predict the uncertainty for DIC images. This paper presents those equations and the resulting error surfaces for trial speckle images. Comparison of the UQ results with experimentally subpixel-shifted images is also discussed.

99 GENERAL AND MISCELLANEOUS↗

Solution of D dimensional Dirac equation for hyperbolic tangent potential using NU method and its application in material properties

The analytical solution of D-dimensional Dirac equation for hyperbolic tangent potential is investigated using Nikiforov-Uvarov method. In the case of spin symmetry the D dimensional Dirac equation reduces to the D dimensional Schrodinger equation. The D dimensional relativistic energy spectra are obtained from D dimensional relativistic energy eigen value equation by using Mat Lab software. The corresponding D dimensional radial wave functions are formulated in the form of generalized Jacobi polynomials. The thermodynamically properties of materials are generated from the non-relativistic energy eigen-values in the classical limit. In the non-relativistic limit, the relativistic energy equation reduces to the non-relativistic energy. The thermal quantities of the system, partition function and specific heat, are expressed in terms of error function and imaginary error function which are numerically calculated using Mat Lab software.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-442: Sensitivity of Quality Assurance Tools to Delivery Errors On a Magnetic Resonance-Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the sensitivity of the quality assurance (QA) tools actively used on a clinical MR-IGRT system for potential delivery errors. Methods: Patient-specific QA procedures have been implemented for a commercially available Cobalt-60 MR-IGRT system. The QA tools utilized were a MR-compatible cylindrical diode-array detector (ArcCHECK) with a custom insert which positions an ionization chamber (Exradin A18) in the middle of the device, as well as an in-house treatment delivery verification program. These tools were tested to investigate their sensitivity to delivery errors. For the ArcCHECK and ion chamber, a baseline was established with a static field irradiation to a known dose. Variations of the baseline were investigated which included rotated gantry, altered field size, directional shifts, and different delivery time. In addition, similar variations were tested with the automated delivery verification program that compared the treatment parameters in the machine delivery logs to the ones in the plan. To test the software, a 3-field conformal plan was generated as the baseline. Results: ArcCHECK noted at least a 13% decrease in passing rate from baseline in the following scenarios: gantry rotation of 1 degree from plan, 5mm change in field size, 2mm lateral shift, and delivery time decrease. Ion chamber measurements remained consistent for these variations except for the 5 second decrease in delivery time scenario which resulted in an 8% difference from baseline. The delivery verification software was able to detect and report the simulated errors such as when the gantry was rotated by 0.6 degrees, the beam weighting was changed by a percent, a single multileaf collimator was moved by 1cm, and the dose was changed from 2 to 1.8Gy. Conclusion: The results show that the current tools used for patient specific QA are capable of detecting small errors in RT delivery with presence of magnetic field.

60 APPLIED LIFE SCIENCES↗

SU-E-J-173: Evaluation of Deformable Registration for Correcting Respiratory Motion in 4DCT Lung Images

Purpose: Deformable Image Registration (DIR) is gaining wider clinical acceptance in radiation oncology. The aim of this work is to characterise a DIR algorithm on publically available 4DCT lung images, such that comparison can be performed against other algorithms. We propose an evaluation method of registration accuracy that takes into account the initial misregistration of the datasets. Methods: The “DIR Validation dataset” ( http://www.creatis.insa-lyon.fr/rio/dir{sub v}alidation{sub d}ata ) provides benchmark data for evaluating 3D CT registration algorithms. It consists of six 4DCT lung datasets (1x1x2mm resolution) with 100 landmarks identified on the end-exhalation and end-inhalation phases. Images were registered to end-inhalation using proprietary form of optical flow in commercial software (Mirada RTx, Mirada Medical, UK). Target registration error was measured before and after DIR, referred to as Initial Registration Error (IRE) and Final Registration Error (FRE). Results: The mean FRE over all landmarks was 1.37±1.81mm. FRE increased with IRE. Mean FRE of 0.86, 0.86, 1.53, 3.38, 4.45, 7.58mm was observed for IRE in the ranges 0–5, 5–10, 10–15, 15–20, 20–25, >25 mm. Higher FRE was observed at the inferior lung, where IRE was greater. Out-of-plane motion contributed more to IRE, and therefore to FRE. Maximum FRE of 20.6mm was observed for IRE of 32.1mm, located at the posterior of the middle lobe for dataset 2. Sub-voxel registration accuracy was achieved for up to 10mm IRE, and increased linearly at 0.3mm FRE/mm IRE thereafter. Conclusion: Publicly available clinical datasets enable algorithms to be compared objectively between publications. However, only reporting average TRE after registration can be misleading as the ability of an algorithm to correct for displacements varies with the IRE or position within the patient. Consequently, algorithms should be characterized using the entire range of initial displacements. For the algorithm assessed, clinically acceptable error within one voxel was achieved for IRE of up to 15mm. TK, AL, and MG are employees of Mirada Medical.

60 APPLIED LIFE SCIENCES↗

WE-G-204-07: Automated Characterization of Perceptual Quality of Clinical Chest Radiographs: Improvements in Lung, Spine, and Hardware Detection

Purpose: To develop and validate more robust methods for automated lung, spine, and hardware detection in AP/PA chest images. This work is part of a continuing effort to automatically characterize the perceptual image quality of clinical radiographs. [Y. Lin et al. Med. Phys. 39, 7019–7031 (2012)] Methods: Our previous implementation of lung/spine identification was applicable to only one vendor. A more generalized routine was devised based on three primary components: lung boundary detection, fuzzy c-means (FCM) clustering, and a clinically-derived lung pixel probability map. Boundary detection was used to constrain the lung segmentations. FCM clustering produced grayscale- and neighborhood-based pixel classification probabilities which are weighted by the clinically-derived probability maps to generate a final lung segmentation. Lung centerlines were set along the left-right lung midpoints. Spine centerlines were estimated as a weighted average of body contour, lateral lung contour, and intensity-based centerline estimates. Centerline estimation was tested on 900 clinical AP/PA chest radiographs which included inpatient/outpatient, upright/bedside, men/women, and adult/pediatric images from multiple imaging systems. Our previous implementation further did not account for the presence of medical hardware (pacemakers, wires, implants, staples, stents, etc.) potentially biasing image quality analysis. A hardware detection algorithm was developed using a gradient-based thresholding method. The training and testing paradigm used a set of 48 images from which 1920 51×51 pixel{sup 2} ROIs with and 1920 ROIs without hardware were manually selected. Results: Acceptable lung centerlines were generated in 98.7% of radiographs while spine centerlines were acceptable in 99.1% of radiographs. Following threshold optimization, the hardware detection software yielded average true positive and true negative rates of 92.7% and 96.9%, respectively. Conclusion: Updated segmentation and centerline estimation methods in addition to new gradient-based hardware detection software provide improved data integrity control and error-checking for automated clinical chest image quality characterization across multiple radiography systems.

60 APPLIED LIFE SCIENCES↗

Bindee

Bindee is a clang tool that outputs a simple pybind11 template given a C++ file for efficient generation of C++-Python bindings. Bindee is intended to be a helper tool for minimizing initial user effort and safeguarding against common runtime errors. Bindee relies on two open-source software to produce bindings. Clang's LibTooling enables bindee to traverse a C++ file's AST to pick out bindable variables and functions, or "bindees." PyBind11 is templated, header-only library for generating C++-Python bindings for variables and functions. Operating purely in C++, bindee does not require learning any new API for accomplishing its task. Additionally, picking the correct pybind11 API for a given bindable element is handled without interaction from the user. Any user input is denoted by '@TEXT@' string substitution. Bindee is capable of generating modular bindings for public class methods, public class variables, enumerations, and free functions and variables. Bindings for templates are also supported. For those familiar with pybind11, bindee does not handle trampolines, C++ extensions through lambdas, or custom type casters.

Kimkno, JasonS.↗

bibcheck

SAND2026-16981O Bibcheck is designed to extract bibliographies from research papers and perform metadata searches to identify errors. It assists authors in checking their bibliographies for metadata errors during the writing process and helps reviewers identify errors in bibliographies of papers under review. The software uses large language models (LLMs) to extract bibliography entries from PDF documents, classifies the type of bibliography entry, and verifies referenced works. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Pearson, Carl [Sandia National Lab. (SNL-CA), Live↗

CCSI Toolset 3.18 Release

CCSI Toolset 3.18 Release Highlights FOQUS was updated to allow installation for users using MacOS on Apple silicon. FOQUS Cloud support was added for user plugins. The Optimality-Based Design of Experiments tutorials were updated to reflect the latest changes in the user interface flow. The plot discrete sliders were fixed for CDF and 3D plots within Uncertainty Quantification, which were not working due to a matplotlib depreciation. The installation was updated to set the default location for the PSUADE executable if found in the environment. Updates were made to allow compatibility with NumPy 1.25. Additional documentation changes were made to fix typographical errors and fix a broken link to optional software.

AS↗

Achieving Verifiable and High Integrity Instrumentation and Control Systems through Complexity Awareness and Constrained Design. Final Report

While most process control industries have been able to embrace digital Instrumentation and Control (I&C) technology to improve performance, reliability, maintainability, and efficiency of production, the nuclear industry has been relatively slow to adopt digital I&C for safety critical plant functions. There are a variety of reasons for this, but in general the nuclear industry takes a conservative stance that new technologies must mature before adoption. A deeper underlying reason for not fully realizing digital I&C and automation in nuclear power is associated with the complexity that can manifest in software-based systems that is different in nature from the complexity of their analog predecessors. Accordingly, this research pursued the development of innovative architectures and methods to “constrain complexity” to enhance verifiability of digital I&C devices. These constraints can positively impact the reduction of Software Common Cause Failures (SCCF) and other systematic errors. The architectural concept developed in this research effort is called SymPLe. SymPLe is specifically aimed at safety critical functions within Nuclear Power Plants and other critical infrastructure where constraining device complexity to support verifiability and safety case arguments is important. The SymPLe architecture is designed to promote “accessible verification” between OEM/utility engineers and the regulatory agencies who review and license nuclear power plant I&C systems. The major contributions of this work to the nuclear industry are: Demonstration of SymPLe as a viable approach to “complexity aware” I&C systems and Embedded Digital Devices.Comprehensive use of model-based design and engineering to produce verifiable I&C systems for the nuclear industry with clear findings on the usability of model-based engineering. Employ comprehensive use of model-based engineering, testing, and verification in an IEC 61508 workflow in support of design assurance. Gathered evidence of “difficult to find” design flaws found using model-based design and testing methods. Detailed the nature of these SCCFs including where they were introduced, the triggers, and how they were found. Gathered evidence on the synergistic use of practical formal methods and testing and how these methods can be used to significantly increase assurance of reduction and avoidance of design flaws.

Testing↗

Quantitative Uncertainty Analysis for Diffraction

Current software uses a least squares statistical method. For each model parameter, current software yields a point estimate and estimated standard error for each point estimate. In contrast, we have employed a Bayesian approach with sampling algorithm to provide a full posterior probability density function on each model parameter. This yields a different type of solution (probabilistic) with better fidelity. The Quantitative Uncertainty Analysis for Diffraction (QUAD) package returns a matrix of affect model parameters as a function of iteration through the MCMC analysis. QUAD is a Python code that allows for analysis of X-ray and neutron diffraction data to infer the structure of materials with quantifiable certainty. The code uses Bayesian statistics and Markov chain sampling algorithms to create posterior probability distributions on all material structure parameters that are modeled by a researcher. The statistical packages use the open source GSASII project as a library to calculate model diffraction patterns.

Fancher, ChristopherM↗

Methodology evaluation: Effects of independent verification and intergration on one class of application

The effects of an independent verification and integration (V and I) methodology on one class of application are described. Resource profiles are discussed. The development environment is reviewed. Seven measures are presented to test the hypothesis that V and I improve the development and product. The V and I methodology provided: (1) a decrease in requirements ambiguities and misinterpretation; (2) no decrease in design errors; (3) no decrease in the cost of correcting errors; (4) a decrease in the cost of system and acceptance testing; (5) an increase in early discovery of errors; (6) no improvement in the quality of software put into operation; and (7) a decrease in productivity and an increase in cost.

Page, J.↗

An investigation of the crustal properties of Australia and surrounding regions derived from interpretation of MAGSAT anomaly field data

The 2 deg averaged data set was analyzed and filtered to produce a magnetic anomaly map of the Australian continental region. The map was overlain on a tectonic map of Australia and correlations were made. A data set was selected that is dominated by relatively low elevation profiles with small changes of elevation within the Australian area in an effort to maximize the crustal anomaly field signal and reduce the effect of variation in satellite elevation. Support systems, both hardware and software are described and best-worst case errors encountered during processing of MAGSAT investigator tapes are summarized. The Broken Ridge anomaly was studied for model development purposes.

Johnson, B. D.↗

Development of a flight software testing methodology

The research to develop a testing methodology for flight software is described. An experiment was conducted in using assertions to dynamically test digital flight control software. The experiment showed that 87% of typical errors introduced into the program would be detected by assertions. Detailed analysis of the test data showed that the number of assertions needed to detect those errors could be reduced to a minimal set. The analysis also revealed that the most effective assertions tested program parameters that provided greater indirect (collateral) testing of other parameters. In addition, a prototype watchdog task system was built to evaluate the effectiveness of executing assertions in parallel by using the multitasking features of Ada.

Mccluskey, E. J.↗

Dynamic assertion testing of flight control software

Assertions are used to dynamically test fault tolerant flight software. The experiment showed that 87% of typical errors introduced into the program would be detected by assertions. Detailed analysis of the test data showed that the number of assertions needed to detect those errors could be reduced to a minimal set. The analysis also revealed that the most effective assertions tested program parameters that provided greater indirect (collateral) testing of other parameters.

Andrews, D. M.↗