Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Simulation methods.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

The role of deviatoric stress and dislocations on the α to ω phase transformation in Ti

Under extreme conditions, α-Ti becomes unstable and transforms either into β-Ti at high temperature or into ω-Ti at high pressure. In what concerns the α to ω phase transformation (PT), there has been a wide range of experimentally reported transition pressures from approximately 2 to 15 GPa at room temperature. Deviatoric stresses and internal defects are often assumed to be the root cause of this variation. Here, in this study, these postulates are revisited using both continuum mechanics and molecular dynamics (MD) simulations. First, a simple continuum model, assuming linear elasticity and isotropic plasticity, is developed to describe the effects of applied stress and dislocations on the stability of an ω nucleus in an infinite α domain. Second, a new MD simulation method is developed to generate an ω nucleus in the α domain utilizing the displacement field identified from the topological analysis. Results from MD simulations show that despite the fact that phase diagrams typically delineate the limits between two phases in terms of only P and T, deviatoric stress promotes the α to ω phase transformation by reducing the critical radius above which an ω nucleus is stable. Furthermore, the required deviatoric stress to nucleate and stabilize a nanoscale ω nucleus is likely emanating from the internal stress of defects such as dislocations. The MD-informed micromechanics models are used to identify favorable configurations where dislocations help favor the α to ω transformation. These configurations show that the interaction with a basal or prismatic dislocation reduces the critical radius of a ω nucleus by about 10 or 16 %, respectively. In addition, prismatic edge dislocations are found to promote the growth of ω nucleus when interacting with the ($\bar{1}$$\bar{1}$20) α //(0001) ω interface. Importantly, a simple model of the arrival of dislocation at an ω nucleus suggests that PT does not necessarily require a pile-up to be present but could alternatively be mediated by a constant rapid flow of dislocations.

36 MATERIALS SCIENCE↗

HALOS (Heliostat Aimpoint and Layout Optimization Software) [SWR-21-41]

Heliostat Aimpoint and Layout Optimization Software (HALOS) is an open-source software package that allows users to explore solar field layout optimization, aimpoint strategy optimization, and performance characterization of concentrating solar power tower plants. Users interface with the tool through python, and results are reported in time series tables, plots, runtime logs, and flat-file outputs. Users choose from a list of variables such as tower height, receiver capacity, flux limits, design-point irradiance, etc., and specify information about the system using a small collection of flat files. The software can then optimize the specified variables (e.g., aimpoints for each heliostat) to maximize the thermal energy delivered to the receiver while adhering to flux limits. HALOS is implemented to be flexible with respect to flux characterization methods, but includes a direct connection to NREL's SolarPILOT™ software via its python API so that users can utilize high-fidelity flux simulation methods that have already been developed.

Zolan, Alexander↗

Solutions to Droop and the Green Gap by Novel Carrier Injection

Long-wavelength (green, yellow, red) visible light-emitting diodes (LEDs) have historically been inefficient compared to blue light-emitters in the III-nitrides. This is due to many factors, including poor material quality due to the low growth temperatures required for high Incomposition InGaN quantum wells (QWs), and the polar nature of the III-nitride crystal structure. Spontaneous and piezoelectric polarization in the III-nitrides causes enhanced quantum-confined Stark effect (QCSE), which spatially separates electrons and holes and reduces radiative recombination (ie: light output) from the devices. Polarization in the crystal also induces additional potential barriers that electrons and holes must cross over before entering the QWs where they can recombine to emit light. Both of these polarization effects worsen as emission wavelength increases, making blue III-nitride LEDs are the most efficient and red III-nitride LEDs the least efficient. The focus of this project has been solving the latter polarization-related issue through the implementation of V-defects in long wavelength LEDs. V-defects are morphological defects which are commonly observed in c-plane III-nitrides. They are observed as hexagonal pyramid-shaped depressions on the c-plane surface, with six semipolar sidewalls. They typically form at the apex of threading dislocations (TDs) under conditions of kinetically-limited growth and low growth-temperature. They were initially thought to be detrimental to LED performance and much early work focused on eliminating them entirely from III-nitride devices. However, over the past decade work has emerged that indicate that they can improve LED performance by allowing electrons and holes to bypass the polarization-induced barriers present in the c-plane and directly enter the QWs of an LED. This is due to the semipolar nature of the V-defect sidewall: these sidewalls are thin and lack the polarization-induced barriers which prevent carriers easily moving between layers. V-defects have since been determined to be an efficient avenue by which to inject electrons and holes into the c-plane QWs where they can recombine to emit light. Throughout this project we have explored lateral injection through a variety of methods: simulation (Task 2), epitaxial growth of V-defect and non-V-defect LEDs (Tasks 1, 3, 4, 5, 6), and advanced characterization methods (Task 7). All tasks have been completed. A description of each task completed follows from this section.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying transport and electrocatalytic reaction processes in a gastight rotating cylinder electrode reactor via integration of Computational Fluid Dynamics modeling and experiments

Understanding the complexity of the multiple processes of mass, momentum, charge, and heat transport, and how these affect reaction kinetics at the electrode/electrolyte interface is one of the major challenges in the field of energy and catalysis. The rapid and rational scale-up of electrocatalytic systems to industrial scales require a detailed understanding of nonlinear transport-reaction processes, accessible only through the building of multi-physics models that capture with high fidelity the complexity of real-world devices. The gastight rotating cylinder electrode (RCE) reactor is a promising lab-scale tool that can decouple transport from intrinsic kinetics to generate data for first-principle models useful in the design of industrial, electrochemical reactors. Computational Fluid Dynamics (CFD) studies have previously been used to investigate the bulk flow in RCE reactors for simple corrosion and electroplating processes. However, the quantification of changes in local concentration within the viscous layer where catalysis takes place requires capturing the correct flow conditions inside the hydrodynamic boundary layer near the surface of the electrode. Further, this requires simulations with spatial resolution in the nm and μm scale and temporal resolutions between ms and s scales that are similar to the timescales for reactions on the electrode surface. In this study, experimental electrocatalysis is combined with CFD modeling to elucidate and parameterize the hydrodynamics in a gastight RCE reactor. CFD simulations of the electrochemical ferricyanide reduction reaction under mass transport limited conditions are used to evaluate the validity of the CFD model parameters by comparing calculated dimensionless mass transport descriptors to dimensionless correlations obtained experimentally. Justifications for assumptions and details of the simulation methods used in this study are presented to provide a detailed understanding of the effect that each model parameter has on the ability to accurately simulate electrocatalysis in RCE systems. The simulation methodology reported here is a first step towards the development of multi-scale models for the study of transport dependent electrocatalytic processes, such as the electrochemical transformation of CO 2 to fuels and chemicals.

42 ENGINEERING↗

Digital quantum magnetism on a trapped-ion quantum computer

Digital quantum matter—realized when discrete quantum gates approximate continuous time evolution—is susceptible to heating into chaotic, structureless states. If digitization errors are adequately suppressed, a long-lived transient regime of approximately energy-conserving dynamics can be observed on gate-based quantum computers. Conservation of energy, in turn, enables the exploration of a wide variety of complex behaviours observed in equilibrium systems, ranging from the non-trivial microscopic origins of thermalization itself to the stabilization of effective models hosting exotic emergent properties. Here we use Quantinuum’s H2 quantum computer to simulate digitized dynamics of the quantum Ising model, suppressing digitization errors well enough to observe thermalization on timescales that severely challenge classical simulation methods. Relaxation of an inhomogeneous state reveals an emergent hydrodynamics owing to approximate energy conservation and we compute the associated diffusion constant. By reprogramming our simulations to take place on a triangular lattice with periodic boundary conditions, we observe thermalization consistent with emergent gauge and topological constraints resulting from lattice frustration. Furthermore, our results were enabled by continued advances in two-qubit gate quality (native partial entangler fidelities of 99.94(1)%) and establish digital quantum computers as powerful tools for studying (effectively) continuous-time dynamics.

Information theory and computation↗

SU-E-J-205: Monte Carlo Modeling of Ultrasound Probes for Real-Time Ultrasound Image-Guided Radiotherapy

Purpose: To quantify the effect of ultrasound (US) probe beam attenuation for radiation therapy delivered under real-time US image guidance by means of Monte Carlo (MC) simulations. Methods: MC models of two Philips US probes, an X6-1 matrix-array transducer and a C5-2 curved-array transducer, were built based on their CT images in the EGSnrc BEAMnrc and DOSXYZnrc codes. Due to the metal parts, the probes were scanned in a Tomotherapy machine with a 3.5 MV beam. Mass densities in the probes were assigned based on an electron density calibration phantom consisting of cylinders with mass densities between 0.2–8.0 g/cm{sup 3}. Beam attenuation due to the probes was measured in a solid water phantom for a 6 MV and 15 MV 15x15 cm{sup 2} beam delivered on a Varian Trilogy linear accelerator. The dose was measured with the PTW-729 ionization chamber array at two depths and compared to MC simulations. The extreme case beam attenuation expected in robotic US image guided radiotherapy for probes in upright position was quantified by means of MC simulations. Results: The 3.5 MV CT number to mass density calibration curve was found to be linear with R{sup 2} > 0.99. The maximum mass densities were 4.6 and 4.2 g/cm{sup 3} in the C5-2 and X6-1 probe, respectively. Gamma analysis of the simulated and measured doses revealed that over 98% of measurement points passed the 3%/3mm criteria for both probes and measurement depths. The extreme attenuation for probes in upright position was found to be 25% and 31% for the C5-2 and X6-1 probe, respectively, for both 6 and 15 MV beams at 10 cm depth. Conclusion: MC models of two US probes used for real-time image guidance during radiotherapy have been built. As a Result, radiotherapy treatment planning with the imaging probes in place can now be performed. J Schlosser is an employee of SoniTrack Systems, Inc. D Hristov has financial interest in SoniTrack Systems, Inc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NONRESONANT INTERACTION OF CHARGED ENERGETIC PARTICLES WITH LOW-FREQUENCY NONCOMPRESSIVE TURBULENCE: NUMERICAL SIMULATION

A new method for simulating the three-dimensional dynamics of charged energetic particles in very broadband noncompressive magnetic turbulence is introduced. All scales within the primary inertial range of the turbulence observed in the solar wind near 1 AU are now included for the independent computations of both the particle dynamics and the turbulent magnetic field lines (MFLs). While previous theories of resonant particle pitch-angle (PA) scattering and transport in interplanetary magnetic fields had favored interpreting the observed depletions in the electron PA distributions (PADs) around 90 Degree-Sign PA as evidence of poor scattering at low PA cosines, the computed particle dynamics reveal a very different reality. The MFL directions now vary on many scales, and the PADs are depleted around 90 Degree-Sign PA due to nonresonant filtering of the particles that propagate at too large an angle to the local magnetic field. Rather than being too weak, the scattering through 90 Degree-Sign PA is actually so strong that the particles (electrons and protons/ions) are reflected and trapped in the turbulent magnetic fields. While the low-frequency nonresonant turbulence produces ubiquitous magnetic traps that only let through particles with the most field-aligned velocities, higher-frequency near-gyroscale turbulence, when present, enhances particle transport by allowing the particles to navigate between magnetic traps. Finally, visualizing both particle trajectories and MFLs in the very same turbulence reveals a powerful tool for understanding the effects of the turbulent fields on the particle dynamics and cross-field transport. Some cross-field-line scattering, strongly amplified by MFL dispersal, results in a strong cross-field scattering of the particles. From this visualization, it also appears that near-gyroscale turbulence, previously known as gyroresonant turbulence, does not resonantly interact with the particles. The interaction between particles and fields at or near the gyroscale, though potentially strong, does not actually involve the periodic driving of a true resonance.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-155: Validation of a Commercial Monte Carlo Dose Calculation Algorithm for Proton Therapy

Purpose: Compare proton pencil beam scanning dose measurements to GATE/GEANT4 (GMC) and RayStation™ Monte Carlo (RMC) simulations. Methods: Proton pencil beam models of the IBA gantry at the Seattle Proton Therapy Center were developed in the GMC code system and a research build of the RMC. For RMC, a preliminary beam model that does not account for upstream halo was used. Depth dose and lateral profiles are compared for the RMC, GMC and a RayStation™ pencil beam dose (RPB) model for three spread out Bragg peaks (SOBPs) in homogenous water phantom. SOBP comparisons were also made among the three models for a phantom with a (i) 2 cm bone and a (ii) 0.5 cm titanium insert. Results: Measurements and GMC estimates of R80 range agree to within 1 mm, and the mean point-to-point dose difference is within 1.2% for all integrated depth dose (IDD) profiles. The dose differences at the peak are 1 to 2%. All of the simulated spot sigmas are within 0.15 mm of the measured values. For the three SOBPs considered, the maximum R80 deviation from measurement for GMC was −0.35 mm, RMC 0.5 mm, and RPB −0.1 mm. The minimum gamma pass using the 3%/3mm criterion for all the profiles was 94%. The dose comparison for heterogeneous inserts in low dose gradient regions showed dose differences greater than 10% at the distal edge of interface between RPB and GMC. The RMC showed improvement and agreed with GMC to within 7%. Conclusion: The RPB dosimetry show clinically significant differences (> 10%) from GMC and RMC estimates. The RMC algorithm is superior to the RPB dosimetry in heterogeneous media. We suspect modelling of the beam’s halo may be responsible for a portion of the remaining discrepancy and that RayStation will reduce this discrepancy as they finalize the release. Erik Traneus is employed as a Research Scientist at RaySearch Laboratories. The research build of the RayStation TPS used in the study was made available to the SCCA free of charge. RaySearch did not provide any monetary support other than a license to use the research build of the TPS.

60 APPLIED LIFE SCIENCES↗

Flux tube train model for local turbulence simulation of toroidal plasmas

A new simulation method for local turbulence in toroidal plasmas is developed by extending the conventional idea of the flux tube model. In the new approach, a train of flux tubes is employed, where flux tube simulation boxes are serially connected at each end along a field line so as to preserve a symmetry of the local gyrokinetic equations for image modes in an axisymmetric torus. Validity of the flux tube train model is confirmed against the toroidal ion temperature gradient turbulence for a case with a long parallel correlation of fluctuations, demonstrating numerical advantages over the conventional method in the time step size and the symmetry-preserving property.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Equilibrium cycle pin by pin transport depletion calculations with DeCART

As the Advanced Fuel Cycle Initiative (AFCI) program has matured it has become more important to utilize more advanced simulation methods. The work reported here was performed as part of the AFCI fellowship program to develop and demonstrate the capability of performing high fidelity equilibrium cycle calculations. As part of the work here, a new multi-cycle analysis capability was implemented in the DeCART code which included modifying the depletion modules to perform nuclide decay calculations, implementing an assembly shuffling pattern description, and modifying iteration schemes. During the work, stability issues were uncovered with respect to converging simultaneously the neutron flux, isotopics, and fluid density and temperature distributions in 3-D. Relaxation factors were implemented which considerably improved the stability of the convergence. To demonstrate the capability two core designs were utilized, a reference UOX core and a CORAIL core. Full core equilibrium cycle calculations were performed on both cores and the discharge isotopics were compared. From this comparison it was noted that the improved modeling capability was not drastically different in its prediction of the discharge isotopics when compared to 2-D single assembly or 2-D core models. For fissile isotopes such as U-235, Pu-239, and Pu-241 the relative differences were 1.91%, 1.88%, and 0.59%), respectively. While this difference may not seem large it translates to mass differences on the order of tens of grams per assembly, which may be significant for the purposes of accounting of special nuclear material. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental and Monte Carlo determination of the TG-43 dosimetric parameters for the model 9011 THINSeed brachytherapy source

Purpose: AAPM TG-43 brachytherapy dosimetry parameters for a new, smaller diameter {sup 125}I brachytherapy source (THINSeed, model 9011) were determined using LiF:Mg,Ti thermoluminescent dosimeter (TLD-100) microcubes and Monte Carlo simulations. Methods: Two polymethyl methacrylate phantoms were machined to hold TLD-100 microcubes at specific locations for the experimental determination of the radial dose function, dose-rate constant, and anisotropy functions of the new source. The TG-43 parameters were also calculated using Monte Carlo simulations. For comparison, the model 6711 source was also investigated. Results: Experimental results for both models 9011 and 6711 sources showed good agreement with Monte Carlo values, as well as with previously published values. Conclusions: The TG-43 parameters for the new source model are similar to those of model 6711; however, they represent two separate sources and TG-43 parameters used in treatment planning must be source specific.

61 RADIATION PROTECTION AND DOSIMETRY↗

Efficient implicit LES method for the simulation of turbulent cavitating flows

We present a numerical method for efficient large-eddy simulation of compressible liquid flows with cavitation based on an implicit subgrid-scale model. Phase change and subgrid-scale interface structures are modeled by a homogeneous mixture model that assumes local thermodynamic equilibrium. Unlike previous approaches, emphasis is placed on operating on a small stencil (at most four cells). The truncation error of the discretization is designed to function as a physically consistent subgrid-scale model for turbulence. We formulate a sensor functional that detects shock waves or pseudo-phase boundaries within the homogeneous mixture model for localizing numerical dissipation. In smooth regions of the flow field, a formally non-dissipative central discretization scheme is used in combination with a regularization term to model the effect of unresolved subgrid scales. The new method is validated by computing standard single- and two-phase test-cases. Comparison of results for a turbulent cavitating mixing layer obtained with the new method demonstrates its suitability for the target applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a Smart Signal Detection Method for Cyclic Voltammetry via Artificial Neural Intelligence

The electrorefiner (ER) is the heart of pyroprocessing technology which is a high-temperature method for separating uranium from Used Nuclear Fuel (UNF). It is important to improve this technology with respect to nuclear materials detection and accountability. Artificial Neural Intelligence (ANI) is a novel data analysis and simulation method that can be applied to electrochemical data sets. This computational code, which has been performed using the commercial software MATLAB, can be trained to generalize adequate electrical current and potential simulated data sets for the unseen data with a high accuracy of prediction. For this purpose, a massive collection of cyclic voltammetry (CV) data sets by Hoover (2014), for 0.5, 1, 2.5, and 5 wt% of zirconium chloride in LiCl-KCl molten salt with different scan rates at 773 K has been considered. The computer is trained via ANI to predict the unseen data after providing suitable hidden layers and validation numbers. In addition, this work can trace the CV plot for a blind condition by interpolating between two simulated data set. The different hidden layers with various neurons (from 5 to 30) at several validation numbers (from 5 to 30) has been studied and the average percent error between experimental and theoretical data for 0.5 wt% with 200 and 450 mV/s has been calculated. Preliminary results demonstrate that if the number of hidden layers increases from one to three, the average error falls down from 44% to around 8%. The best condition which gives a minimum average percent error has been discovered and the simulated CV graph has been compared with the experimental data. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-J-163: A Biomechanical Lung Model for Respiratory Motion Study

Purpose: This work presents a biomechanical model to investigate the complex respiratory motion for the lung tumor tracking in radiosurgery by computer simulation. Methods: The models include networked massspring-dampers to describe the tumor motion, different types of surrogate signals, and the force generated by the diaphragm. Each mass-springdamper has the same mechanical structure and each model can have different numbers of mass-spring-dampers. Both linear and nonlinear stiffness parameters were considered, and the damping ratio was tuned in a range so that the tumor motion was over-damped (no natural tumor oscillation occurs without force from the diaphragm). The simulation was run by using ODE45 (ordinary differential equations by Runge-Kutta method) in MATLAB, and all time courses of motions and inputs (force) were generated and compared. Results: The curvature of the motion time courses around their peaks was sensitive to the damping ratio. Therefore, the damping ratio can be determined based on the clinical data of a high sampling rate. The peak values of different signals and the time the peaks occurred were compared, and it was found that the diaphragm force had a time lead over the tumor motion, and the lead time (0.1–0.4 seconds) depended on the distance between the tumor and the diaphragm. Conclusion: We reported a model based analysis approach for the spatial and temporal relation between the motion of the lung tumor and the surrogate signals. Due to the phase lead of the diaphragm in comparing with the lung tumor motion, the measurement of diaphragm motion (or its electromyography signal) can be used as a beam gating signal in radiosurgery, and it can also be an additional surrogate signal for better tumor motion tracking. The research is funded by the American Cancer Society (ACS) grant. The grant name is: Frameless SRS Based on Robotic Head Motion Cancellation. The grant number is: RSG-13-313-01-CCE.

60 APPLIED LIFE SCIENCES↗

A novel lateral disequilibrium inclusive (LDI) pencil-beam based dose calculation algorithm: Evaluation in inhomogeneous phantoms and comparison with Monte Carlo calculations

Purpose: Pencil-beam (PB) based dose calculation for treatment planning is limited by inaccuracies in regions of tissue inhomogeneities, particularly in situations with lateral electron disequilibrium as is present at tissue/lung interfaces. To overcome these limitations, a new ''lateral disequilibrium inclusive'' (LDI) PB based calculation algorithm was introduced. In this study, the authors evaluated the accuracy of the new model by film and ionization chamber measurements and Monte Carlo simulations. Methods: To validate the performance of the new LDI algorithm implemented in Corvus 09, eight test plans were generated on inhomogeneous thorax and pelvis phantoms. In addition, three plans were calculated with a simple effective path length (EPL) algorithm on the inhomogeneous thorax phantom. To simulate homogeneous tissues, four test plans were evaluated in homogeneous phantoms (homogeneous dose calculation). Results: The mean pixel pass rates and standard deviations of the gamma 4%/4 mm test for the film measurements were (96{+-}3)% for the plans calculated with LDI, (70{+-}5)% for the plans calculated with EPL, and (99{+-}1)% for the homogeneous plans. Ionization chamber measurements and Monte Carlo simulations confirmed the high accuracy of the new algorithm (dose deviations {<=}4%; gamma 3%/3 mm {>=}96%)Conclusions: LDI represents an accurate and fast dose calculation algorithm for treatment planning.

60 APPLIED LIFE SCIENCES↗

Scalable, Physical Effects Measureable Microgridfor Cyber Resilience Analysis

SPEMMCRA provides a low-cost simulated method to provide for testing of control theory and cybersecurity approaches to microgrid implementations. Specifically, this physics-based approach provides realistic responses to compare control strategies in simulation, but also to demonstrate actions that can or cannot be taken in taking cybersecurity actions . As communications interfaces or other actions are taken that affect the flow of data, SPEMMCRA can show whether the microgrid operation is adversely affected by what is intended to mitigate a cybersecurity event.

Rieger, CraigG↗

SU-E-T-455: Characterization of 3D Printed Materials for Proton Beam Therapy

Purpose: The widespread availability of low cost 3D printing technologies provides an alternative fabrication method for customized proton range modifying accessories such as compensators and boluses. However the material properties of the printed object are dependent on the printing technology used. In order to facilitate the application of 3D printing in proton therapy, this study investigated the stopping power of several printed materials using both proton pencil beam measurements and Monte Carlo simulations. Methods: Five 3–4 cm cubes fabricated using three 3D printing technologies (selective laser sintering, fused-deposition modeling and stereolithography) from five printers were investigated. The cubes were scanned on a CT scanner and the depth dose curves for a mono-energetic pencil beam passing through the material were measured using a large parallel plate ion chamber in a water tank. Each cube was measured from two directions (perpendicular and parallel to printing plane) to evaluate the effects of the anisotropic material layout. The results were compared with GEANT4 Monte Carlo simulation using the manufacturer specified material density and chemical composition data. Results: Compared with water, the differences from the range pull back by the printed blocks varied and corresponded well with the material CT Hounsfield unit. The measurement results were in agreement with Monte Carlo simulation. However, depending on the technology, inhomogeneity existed in the printed cubes evidenced from CT images. The effect of such inhomogeneity on the proton beam is to be investigated. Conclusion: Printed blocks by three different 3D printing technologies were characterized for proton beam with measurements and Monte Carlo simulation. The effects of the printing technologies in proton range and stopping power were studied. The derived results can be applied when specific devices are used in proton radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

WE-FG-207B-06: Plaque Composition Measurement with Dual Energy Computed Tomography

Purpose: To investigate the feasibility of characterizing arterial plaque composition in terms of water, lipid and protein or calcium using dual energy computed tomography. Characterization of plaque composition can potentially help distinguish vulnerable from stable plaques. Methods: Simulations studies were performed by the CT simulator based on ASTRA tomography toolbox. The beam energy for dual energy images was selected to be 80 kVp and 135 kVp. The radiation dose and energy spectrum for the CT simulator were carefully calibrated with respect to a 320-slice CT scanner. A digital chest phantom was constructed using Matlab for calibration and plaque measurement. Pure water, lipid, protein or calcium was used for calibration and a mixture of different volume percentages of these materials were used for validation purposes. Non-calcified plaque was simulated using water, lipid and protein with volumetric percentage range of 35%∼65%, 5%∼60% and 5%∼40%, respectively. Calcified plaque was simulated using water, lipid and calcium with volumetric percentage range of 50%∼80%, 8%∼45% and 3%∼13%, respectively. We employed iterative sinogram processing (ISP) to reduce the beam hardening effect in the simulation to improve the decomposition results. Results: The simulated known composition and dual energy decomposition results were in good agreement. Water, lipid and protein (calcium) mixtures were decomposed into water, lipid and protein (calcium) contents. The RMS errors of volumetric percentage for the water, lipid and protein (non-calcified plaque) decomposition, as compared to known values, were estimated to be approximately 5.74%, 2.54%, and 0.95% respectively. The RMS errors of volumetric percentage for the water, lipid and Calcium (calcified plaque) decomposition, as compared to known values, were estimated to be approximately 7.4%, 8.64%, and 0.08% respectively. Conclusion: The results of this study suggest that the dual energy decomposition can potentially be used to quantify the water, lipid, and protein or calcium composition of a plaque with relatively good accuracy. Grant funding from Toshiba Medical Systems and Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗