Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Combining Mass Spectrometry of Picoliter Samples with a Multicompartment Electrodynamic Trap for Probing the Chemistry of Droplet Arrays

Single droplet levitation provides contactless access to the microphysical and chemical properties of micrometer-sized samples. Most applications of droplet levitation to chemical and biological systems use nondestructive optical techniques to probe droplet properties. To provide improved chemical specificity, we coupled a multicompartment quadrupole electrodynamic trap (QET) with single droplet mass spectrometry. Our QET continuously traps a monodisperse droplet population (tens to hundreds of droplets) and allows for the simultaneous sizing of a single droplet using its Mie scattering pattern. Single droplets are subsequently ejected into the ionization region of an ambient pressure inlet mass spectrometer. We optimized two complementary soft ionization techniques for picoliter aqueous droplets: (1) paper spray (PS) ionization and (2) thermal desorption glow discharge (TDGD) ionization. Both techniques detect oxygenated organic acids in single droplets, with signal-to-noise ratios >100 and detection limits on the order of 10 pg. Sensitivity and reproducibility across single droplets are driven by the droplet deposition location and spray stability in PS-MS and the ionization region humidity and analyte evaporation rate in TDGD-MS. Importantly, the analyte evaporation rate can control the TDGD-MS quantitative capability because high evaporation rates result in significant ion suppression. Additionally, this effect is mitigated by optimizing the vaporization temperature, droplet size range, and analyte volatility. We demonstrate quantitative and reproducible measurements with a droplet internal standard (<10% RSD) and compare the sensitivity of PS-MS and TDGD-MS. Finally, we demonstrate the application of QET-MS to the study of heterogeneous chemical kinetics with the reaction of gas phase O 3 and aqueous maleic acid droplets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large Area Detection of Microstructural Defects with Multi-Mode Ultrasonic Signals

Cyclic loading or other stresses can lead to development of cracks and crack growth in mechanical structures, leading to eventual failure. While ultrasound imaging can be used for non-destructive testing of such structures, conventional ultrasound techniques are often limited by crack size, density, and areal coverage. An effective characterization of real-world, large-area structures is required at an early damage stage to prevent catastrophic failure and predict remaining life. In this study, a new nonlinear ultrasonic testing (NUT) method is proposed for large-area monitoring of practical structures with arbitrary complexity by using multiple-mode guided-wave ultrasonic signals. The proposed guided-wave NUT technique requires single-element transducers, simple electronics, and a mixed time-frequency domain signal processing. As a proof-of-concept demonstration, numerical simulations and experiments are performed on an A36 carbon steel beam assembly with previously formed microstructural defects that cause nonlinearities in ultrasonic response. The quadratic dependence of the nonlinear wave excitation on the input ultrasonic signal amplitude is shown by numerical simulations, and such a nonlinear ultrasonic response is experimentally observed in the zone with a high density of microstructural defects.

36 MATERIALS SCIENCE↗

The real-time data processing and acquisition system for Project 8 Phase II

In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or 83m Kr are detected via their ≈26 GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting ≲10 ms and changing in frequency by ≲1 MHz/ms. To detect these signals, the Project 8 collaboration developed a Data Acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100 MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. Finally, we describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.

Data acquisition↗

A Size-Selectively Biomolecule-Immobilized Nanoprobe-Based Chemiluminescent Lateral Flow Immunoassay for Detection of Avian-Origin Viruses

Here, a signal-amplifiable nanoprobe-based chemiluminescent lateral flow immunoassay (CL-LFA) was developed to detect avian influenza viruses (AIV) and other contagious and fatal viral avian-origin diseases worldwide. Signal-amplifiable nanoprobes are capable of size-selective immobilization of antibodies (binding receptors) and enzymes (signal transducers) on sensitive paper-based sensor platforms. Particle structure designs and conjugation pathways conducive for antigen accessibility to maximum amounts of immobilized enzymes and antibodies have advanced. The detection limit of the CL-LFA using the signal-amplifiable nanoprobe for the nucleoprotein of the H3N2 virus was 5 pM. Sensitivity tests for low pathogenicity avian influenza H9N2, H1N1, and high pathogenicity avian influenza H5N9 viruses were conducted, and the detection limits of CL-LFA were found to be 10 3.5 50% egg infective dose (EID 50 )/mL, 10 2.5 EID 50 /mL, and 10 4 EID 50 /mL, respectively, which is 20 to 100 times lower than that of a commercial AIV rapid test kit. Moreover, CL-LFA demonstrated high sensitivity and specificity against 37 clinical samples. The signal-amplifiable probe designed in this study is a potential diagnostic probe with ultrahigh sensitivity for applications in the field of clinical diagnosis, which requires sensitive antigen detection as evidenced by enhanced signaling capacity and sensitivity of the LFAs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Material transfers detection with seismic observations

We are exploring the use of data from a seismic network around a research nuclear reactor and isotope production facility at Oak Ridge National Laboratory to study activity patterns related to the transfer of nuclear material. A sensor network with eight seismometers was installed around the High Flux Isotope Reactor and the Radiochemical Engineering Development Center and started operating in October 2019. These data are used to detect and characterize operational events around facility. We are using those data to extract signals related to the movement of vehicles involved in the transport of nuclear materials (e.g., transportation of reactor fuel, targets, and product isotopes). Large vehicles produce mechanical energy that can be observed as seismic signals, either as the result of sound emanating from the vehicle engine or by the generation of surface waves as a response of the ground to the load of the vehicles. In particular, the station located near the entrance gate of the facility displays a clear seismic signature as vehicles cross a metal platform on the ground. This signal is characterized by sharp energy bursts that correspond to the number of axles on the vehicle. We developed and are testing an algorithm to identify sequences of energy bursts to count and characterize vehicles of different sizes. We are also exploring the use of seismic polarization analysis to measure the degree of polarization of the observed signals. These two techniques for detection and characterization of vehicles used for nuclear material transfers will be validated with seismic data from a targeted collection using different vehicles and routes similar to the ones used in real-life scenarios at the High Flux Isotope Reactor.

Marcillo, Omar↗

The imprint of cosmic voids from the DESI Legacy Survey DR9 Luminous Red Galaxies in the Planck 2018 lensing map through spectroscopically calibrated mocks

The cross-correlation of cosmic voids with the lensing convergence (κ) map of the Cosmic Microwave Background (CMB) fluctuations provides a powerful tool to refine our understanding of the current cosmological model. However, several studies have reported a moderate tension (up to ∼2σ) between the lensing imprint of cosmic voids on the observed CMB and the ΛCDM signal predicted by simulations. To address this “lensing-is-low” tension and to obtain new, precise measurements of the signal, we exploit the large DESI Legacy Survey Luminous Red Galaxy (LRG) data set, covering approximately 19 500 deg 2 of the sky and including about 10 million LRGs at z < 1.05. Our ΛCDM template was created using the Buzzard mocks, which we specifically calibrated to match the clustering properties of the observed galaxy sample by exploiting more than one million DESI spectra. We identified our catalogs of 3D voids in the range 0.35 < z < 0.95 and cross-correlated them through a stacking methodology, dividing the sample into bins according to the redshift and λv values of the voids. For the full void sample, we report a 14σ detection of the lensing signal, with A κ = 1.016 ± 0.054, which increases to 17σ when considering the void-in-void (A κ = 0.944 ± 0.064) and the void-in-cloud (A κ = 0.975 ± 0.060) populations individually, the highest detection significance for studies of this kind. We observe a full agreement between observations and ΛCDM mocks across all redshift bins, sky regions, and void populations considered. In addition to these findings, our analysis highlights the importance of accurately matching sparseness and redshift error distributions between mocks and observations, as well as the role of λ v in enhancing the signal-to-noise ratio through void population discrimination.

79 ASTRONOMY AND ASTROPHYSICS↗

Unsupervised learning from three-component accelerometer data to monitor the spatiotemporal evolution of meso-scale hydraulic fractures

Enhanced geothermal systems can provide a substantial share of the global energy demand. There exist several hurdles in the engineering implementations of such geothermal systems. One such hurdle is the accurate monitoring of the fracture networks created in subsurface through hydraulic stimulation of these systems. Micro seismicity associated with the stimulation is the primary means to locate the event hypocenters for estimating the stimulated rock volume. Existing methods for location the hypocenters are restricted to only the highest amplitude impulsive signals that are simultaneously detected on several sensors. Consequently, a large portion (usually ~99%) of the measurements are left unused. In this paper, an unsupervised manifold-approximation followed by clustering of 3-component accelerometer data is used to analyze the seismicity recorded on a monitoring well. With this method, a larger portion of the measured signal is used for the monitoring of the hydraulic fracture network. We analyze the EGS Collab experiment 1 microseismic data, recorded at the Sanford Underground Research Facility, South Dakota. Using the data from a single three-component accelerometer, the polarization features viz. Azimuth, incidence, rectilinearity, and planarity are used as inputs for the unsupervised manifold approximation followed by clustering. Our study shows that density-based clusters in the projected 3D space correspond to distinct types of hydraulically fractured zones around the injection point. Finally, we show that the temporal evolution of these clusters can be used to track fracture creation and propagation.

58 GEOSCIENCES↗

Mass calibration of DES Year-3 clusters via SPT-3G CMB cluster lensing

We measure the stacked lensing signal in the direction of galaxy clusters in the DarkEnergy Survey Year 3 (DES Y3) redMaPPer sample, using cosmic microwave background (CMB)temperature data from SPT-3G, the third-generation CMB camera on the South PoleTelescope (SPT). Here, we estimate the lensing signal using temperature maps constructed fromthe initial 2 years of data from the SPT-3G 'Main' survey, covering 1500 deg$^{2}$ of the Southernsky. We then use this lensing signal as a proxy for the mean cluster mass of the DES sample. Thethermal Sunyaev-Zel'dovich (tSZ) signal, which can contaminate the lensing signal if notaddressed, is isolated and removed from the data before obtaining the mass measurement. In thiswork, we employ three versions of the redMaPPer catalogue: a Flux-Limited sample containing 8865clusters, a Volume-Limited sample with 5391 clusters, and a Volume&Redshift-Limited sample with4450 clusters. For the three samples, we detect the CMB lensing signal at a significance of12.4σ, 10.5σ and 10.2σ and find the mean cluster masses to be M$_{200m}$ = 1.66±0.13 [stat.]± 0.03 [sys.], 1.97±0.18 [stat.]± 0.05 [sys.],and 2.11±0.20 [stat.]± 0.05 [sys.]×10$^{14}$ M$_{⊙}$, respectively. Thisis a factor of ∼ 2 improvement relative to the precision of measurements with previousgenerations of SPT surveys and the most constraining cluster mass measurements using CMB clusterlensing to date. Overall, we find no significant tensions between our results and masses given byredMaPPer mass-richness scaling relations of previous works, which were calibrated using CMBcluster lensing, optical weak lensing, and velocity dispersion measurements from variouscombinations of DES, SDSS and Planck data. We then divide our sample into 3 redshift and 3richness bins, finding no significant discrepancies with optical weak-lensing calibrated masses inthese bins. We forecast a 5.7% constraint on the mean cluster mass of the DES Y3 sample withthe complete SPT-3G surveys when using both temperature and polarization data and including anadditional ∼ 1400 deg$^{2}$ of observations from the 'Extended' SPT-3G survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine Learning for Anomaly Detection in Neural Network Security and SRF Cavities

This dissertation explores the development and deployment of machine learning approaches to address critical challenges in anomaly detection across two distinct domains: neural network security in federated learning settings and cavity behavior analysis in particle accelerator operations at Jefferson Lab in Newport News, Virginia. Anomaly detection identifies deviations from expected patterns, safeguarding systems in cybersecurity, industry, and research against malicious activities and failures. This dissertation demonstrates how our machine learning approaches enhance detection accuracy and efficiency in both neural network security and industrial applications. First, we investigate vulnerabilities in deep neural networks deployed in federated learning. Although federated learning preserves user privacy by training models locally, it remains vulnerable to backdoor attacks, in which malicious participants embed hidden triggers that induce targeted misbehavior. We propose a self-supervised contrastive learning framework to detect and mitigate such backdoor attacks. In our experiments, this method achieves higher detection accuracy and lower false positive rates than existing defenses, while operating without access to local model updates or original training data and thus preserving the privacy guarantees of the federated setting. Second, we address the operational reliability of superconducting radio-frequency (SRF) cavities at the Continuous Electron Beam Accelerator Facility (CEBAF). Our research leverages an unsupervised learning approach, combined with Principal Component Analysis (PCA) and k-means clustering, to identify anomalous behaviors in SRF cavities. Our method detects subtle anomalous behavior by analyzing SRF signal data. This knowledge allows for the early detection and resolution of potential faults, significantly improving the efficiency and reliability of operations. Third, we extend these insights to time-series anomaly detection more broadly. We design a contrastive-learning based model tailored to increasingly dynamic environments and academic research. This model improves detection accuracy in settings that require real-time monitoring and predictive maintenance. Our research underscores the broader applicability and impact of advanced machine learning techniques in anomaly detection. By extracting meaningful patterns from complex data, machine learning can significantly enhance security in distributed neural networks and improve the efficiency of particle accelerator operations. This dissertation serves as a stepping stone for future investigations into the vast possibilities of anomaly detection, inspiring further exploration and development of machine learning techniques in this field.

Ferguson, Hal [Old Dominion University]↗

Unsupervised Process Anomaly Detection and Identification Using the Leave-One-Variable-Out Approach

Automated anomaly detection and identification can signal equipment issues and pinpoint causes in large-scale industrial systems. For systems with limited failure history, unsupervised machine learning methods can be utilized as they do not require past failures. This study introduces the leave-one-variable-out (LOVO) model, which masks one variable at a time to predict the others, learning underlying process correlations. Detection performance was assessed with synthetic and experimental data, while identification performance used only synthetic data due to its ability to generate labeled anomaly types. For detection using synthetic data, the LOVO model generally outperformed comparative models; while using experimental data, the comparative methods outperformed the LOVO model. However, the comparative methods required selecting a latent size, and these conclusions pertain to using the optimal size. In practice, it would not be feasible to always select the optimal value, and incorrect selections impacted performance. In contrast, the LOVO model does not require a latent space. For identification using synthetic data, the LOVO model was slightly outperformed in interpretability and repeatability but still demonstrated impressive results. These outcomes suggest that the LOVO model is an effective model and may be more easily implemented without the challenging tuning process of selecting a latent size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing Defects Inside Hexagonal Boron Nitride Using Random Telegraph Signals in van der Waals 2D Transistors

Single-crystal hexagonal boron nitride (hBN) is used extensively in many two-dimensional electronic and quantum devices, where defects significantly impact performance. Therefore, characterizing and engineering hBN defects are crucial for advancing these technologies. Here, we examine the capture and emission dynamics of defects in hBN by utilizing low-frequency noise (LFN) spectroscopy in hBN-encapsulated and graphene-contacted MoS 2 field-effect transistors (FETs). The low disorder of this heterostructure allows the detection of random telegraph signals (RTS) in large device dimensions of 100 μm 2 at cryogenic temperatures. Analysis of gate bias- and temperature-dependent LFN data indicate that RTS originates from a single trap species within hBN. By performing multi-space density functional theory (MS-DFT) calculations on a gated defective hBN/MoS 2 heterostructure model, we assign substitutional carbon atoms in boron sites as the atomistic origin of RTS. This study demonstrates the utility of LFN spectroscopy combined with MS-DFT analysis on a low-disorder all-vdW FET as a powerful means for characterizing the atomistic defects in single-crystal hBN.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Single-photon detection using high-temperature cuprate superconductors

The detection of individual quanta of light is important for quantum computation, fluorescence lifetime imaging, single-molecule detection, remote sensing, correlation spectroscopy, and more. Thanks to their broadband operation, high detection efficiency, exceptional signal-to-noise ratio, and fast recovery times, superconducting nanowire single-photon detectors (SNSPDs) have become a critical component in these applications. The operation of SNSPDs based on conventional superconductors, which have a low critical temperature (T c ), requires costly and bulky cryocoolers. This motivated exploration of other superconducting materials with higher T c that would enable single-photon detection at elevated temperatures, yet this task has proven exceedingly difficult. Here we show that with proper processing, high-T c cuprate superconductors can meet this challenge. We fabricated superconducting nanowires (SNWs) out of thin flakes of Bi 2 Sr 2 CaCu2O 8+δ and La 1.55 Sr 0.45 CuO 4 /La 2 CuO 4 (LSCO-LCO) bilayer films and demonstrated their single-photon response up to 25 and 8 K, respectively. The single-photon operation is revealed through the linear scaling of the photon count rate (PCR) on the radiation power. Both of our cuprate-based SNSPDs exhibited single-photon sensitivity at the technologically-important 1.5 μm telecommunications wavelength. Our work expands the family of superconducting materials for SNSPD technology, opens the prospects of raising the temperature ceiling, and raises important questions about the underlying mechanisms of single-photon detection by unconventional superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effective field theory analysis of the first LUX dark matter search

The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6 x 10 -46 cm 2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4 x 10 4 kg ∙ day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring an ultrashort, ultraviolet pulse in a slowly responding, absorbing medium

Frequency-resolved optical gating (FROG) is a common technique for measuring ultrashort laser pulses using an instantaneous, nonlinear-optical interaction as a fast time-gate to measure the pulse intensity and phase. But at high frequencies, materials are often absorbing and it is not always possible to find a medium with a fast nonlinear-optical response. Here we show that an ultrashort, ultraviolet (UV) pulse can be measured in a strongly absorbing medium, using the absorption as the nonlinear-optical time-gate. To do this, we build on our recent implementation of FROG, known as induced-grating cross-correlation FROG (IG XFROG), where an unknown, higher-frequency pulse creates a transient grating that is probed with a lower-frequency, more easily detectable reference pulse. We demonstrate this with an 800 nm reference pulse to characterize 400 nm or 267 nm pulses using ZnS as the nonlinear-optical medium, which is absorptive at and below 400 nm. By scanning the delay between the two UV pulses which create the transient grating, we show that the phase-sensitive instantaneous four-wave-mixing contribution to the nonlinear signal field can be detected and separated from the slower, incoherent part of the response. Measuring a spectrally-resolved cross-correlation in this way and then applying a simple model for the response of the medium, we show that a modified generalized projections (GP) phase-retrieval algorithm can be used to extract the pulse amplitude and phase. We test this approach by measuring chirped UV pulses centered at 400 nm and 267 nm. Since interband absorption (or even photoionization) is not strongly wavelength-dependent, we expect IG XFROG to be applicable deeper into the UV.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Magneto-optical spectroscopy based on pump-probe strobe light

Here, we demonstrate a pump-probe strobe light spectroscopy for sensitive detection of magneto-optical dynamics in the context of hybrid magnonics. The technique uses a combinatorial microwave-optical pump-probe scheme, leveraging both the high-energy resolution of microwaves and high-efficiency detection using optical photons. In contrast with conventional stroboscopy using continuous-wave light, we apply microwave and optical pulses with varying pulse widths, and demonstrate magneto-optical detection of magnetization dynamics in Y 3 Fe 5 O 12 films. The detected magneto-optical signals depend strongly on the characteristics of both the microwave and the optical pulses, as well as their relative time delays. We show that good magneto-optical sensitivity and coherent stroboscopic character are maintained, even at a microwave pump pulse of 1.5 ns and an optical probe pulse of 80 ps, under a 7 MHz clock rate, corresponding to a pump-probe footprint of approximately 1% in one detection cycle. Our results show that time-dependent strobe light measurement of magnetization dynamics can be achieved in the gigahertz frequency range under a pump-probe detection scheme.

36 MATERIALS SCIENCE↗

Design of RUSL Irradiation Experiment with Free Standing Sample

During FY19, the MIMIC-RUSL TREAT test successfully measured the shift in resonance of a cantilever beam as it underwent a grain restructuring event in the TREAT reactor core. FY20 efforts focused on a new capsule design which would replace the cantilever beam with a free-free beam. The free-free beam configuration eliminates the cantilever boundary condition and enables internal friction measurements. A test capsule was designed which supported the sample beam at the nodal points of the first flexural vibration mode. Initial tests detected the resonance peak but the signal to noise level was not high enough for in-situ measurements. Several detection probes were tested and a significant increase in the signal to noise was achieved. Although adequate signals and clean resonance peaks were measured when the beam was centered, the beam did not self-center when displaced resulting in distorted and inconsistent resonance peaks. It was concluded that the free-free beam approach is likely not suited for in-situ measurements. Measurement of ZGV plate waves is another option for in-situ microstructure monitoring and should be considered for future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗