Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SWEEP EFFICIENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

488 records · Page 28

Deep Learning Method for Detecting Precursors to Adverse Events

With the recent advancements in Deep Learning methods, the ability to model large complex heterogeneous data sets are fundamentally changing industry and research. Coupled with hardware improvements, and ease of implementation, a wide variety of deep neural network architectures can quickly be developed to solve a sweeping range of problems such as: object detection in images, automatic healthcare diagnosis using heterogenous data sources, real time language translating and sentence prediction, upscaling low resolution images, and forecasting of multivariate timeseries. Generally, many of these architectures outperform classical machine learning approaches in their respective tasks, however, this typically comes at a cost of interpretability. These black box algorithms generally suffer from lack of transparency in both model complexity as well as the rationale behind the prediction. This lack of comprehension, is driving an emerging area of interest in “Explainable AI”. An algorithm called: “Deep Temporal Multiple Instance Learning”1 was a recently developed to identify precursors to adverse events and has been applied in the aviation domain. The deep learning architecture is designed to capture the evolution of the probability of the outcome over the time preceding the adverse event using a multiple instance learning approach as illustrated in Figure 1. Precursors are defined when the probability of the event has exceeded a threshold at some point in the timeseries, at which point, a sensitivity analysis is performed to determine contributing factors. The contributing factors are used to explain and define the precursor during the periods where the probability score is high. The identified contributing factors are then presented to subject matter experts to provide objective insights into the leading factors associated with the particular adverse event. The algorithm has been tested on flight data from a commercial airline and has the ability to discover precursors to known adverse events that take the form of safety critical operations, such as unstable approach events on final approach. Apart from detecting precursors to adverse events, the converse can also be leveraged to discover corrective actions. These positive actions manifest themselves as periods in the timeseries when the precursor score has been lowered from an elevated state; meaning that if the system had been left uncorrected, it would have eventually reached the adverse event state. Characterizing these state changes can help identify successful interventions that may not have been known before. Policy makers and procedure designers can use this additional knowledge to craft more safety and efficient resilient procedures for future operations and therefore improve the overall performance of the National Airspace.

Matthews, Bryan L.↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗