Catalytic production of tetrahydropyran (THP): a biomass-derived, economically competitive solvent with demonstrated use in plastic dissolution

Tetrahydropyran (THP) is a five-carbon heterocyclic ether that is non-carcinogenic, non-peroxide forming, biodegradable, and economically competitive with tetrahydrofuran (THF) as a solvent. In this work, THP has been synthesized from renewable biomass at >99.8% selectivity and 98% yield via hydrogenation of furfural-derived 3,4-dihydropyran (DHP) over Ni/SiO 2 in a continuous flow reactor at 150–200 °C. The apparent activation energy of THP formation is 31 kJ mol -1 , and the reaction orders with respect to the partial pressures of H 2 , DHP, and THP are: 2, 1, and -0.3. The kinetic data has been fitted to a Hougen–Watson model where the rate limiting step is the hydrogenation of adsorbed DHP. Ni/SiO 2 is shown to have a low deactivation rate constant of 0.012 h -1 over 100 h time on stream and can be regenerated in situ. As a performance advantage, THP is shown to be resistant to ring opening polymerization under strongly acidic conditions that THF is not, revealing it to be a superior solvent. Further, the minimum selling price of THP is competitive with the market price of THF ($$900 – 1400 per ton ) at a DHP feedstock cost of $1000 per ton. Conductor-like Screening Model for Real Solvents (COSMO-RS) and molecular dynamics (MD) simulations with 1008 solvents and 8 common plastics have demonstrated that THP can serve as an alternative solvent to THF, 2-methyltetrahydrofuran (MeTHF), and cyclopentyl methyl ether (CPME) for plastic dissolution, especially low-density polyethylene (LDPE), polypropylene (PP), polystyrene (PS) and polyvinyl chloride (PVC). This work establishes THP as a green solvent with excellent thermal, chemical and peroxidative stability that can be used for numerous applications, including waste plastic recycling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiscale investigation of the mechanism of biomass deconstruction in the dimethyl isosorbide/water Co-solvent pretreatment system

In the context of promoting a circular bioeconomy, the development of green and efficient lignocellulosic biomass pretreatment technologies so as to realize high value-added biomass utilization is of intense interest. We demonstrated the potential of the bio-based green solvent dimethyl isosorbide (DMI) for the fractionation of Eucalyptus biomass with excellent performance. Here, to investigate the mechanisms involved in biomass fractionation, microimaging and microspectroscopic techniques were employed together with molecular dynamics (MD) simulation and COSMO-RS quantum chemical calculations to derive multiscale information. Both the microstructure and regional chemistry of the cell wall vary significantly with the volume ratio of DMI/H 2 O. The strongest effects were found at DMI/H 2 O = 9:1 and showed visible cell wall tearing cracks and cell wall deformation and collapse as well as the lowest values of cell wall thickness and circularity. From the MD simulations, lignin exhibits collapsed-like structure in pure H 2 O with low solvent accessibility surface area (SASA) and radius of gyration (R g ). In contrast, lignin in DMI/H 2 O shows extended structure with high SASA and solvent interactions dominated by van der Waals forces, with maximal contact in the 9:1 (v/v) system. Further, the COSMO-RS calculated sigma (σ-) potential suggests the intermolecular interactions in DMI and DMI/H 2 O co-solvent are weak, leading to stronger interaction with lignin and correspondingly higher lignin dissolution. The radial distribution functions and σ-potential all show that again DMI/H 2 O at 9:1 is an optimal volume ratio for high lignin dissolution. Finally, this study provides a solvent-ratio dependent mechanism for the action of polar aprotic solvents in the deconstruction of biomass.

09 BIOMASS FUELS↗

Multi-scale computational screening and mechanistic insights of cyclic amines as solvents for improved lignocellulosic biomass processing

A computational screening workflow for the efficient deconstruction of cellulose, lignin and hemicellulose fractions of lignocellulosic biomass using cyclic amines as solvents. Lignocellulosic biomass is a promising feedstock for production of affordable fuels and chemicals from renewable resources. Effective solubilization and subsequent deconstruction of its cellulose, hemicellulose, and lignin fractions is essential for the viability of future biorefineries. This study used quantum chemistry-based equilibrium thermodynamics methods to evaluate the potential of 650 cyclic amines to solubilize cellulose, hemicellulose, and lignin. The activity coefficients of solvent - biopolymer interactions were predicted using the COSMO-RS (COnductor-like Screening MOdel for Real Solvents) method and used to identify cyclic amines that can efficiently dissolve and extract selective fractions of biopolymers during biomass pretreatment. Among the 650 cyclic amines, 1-piperazineethanmaine was predicted to be an effective solvent for extracting all three polymers and was experimentally shown to achieve the highest lignin removal (97.1%). Non-covalent interaction, reduced density gradient and quantum chemical calculations were performed to elucidate the dissolution mechanism of lignin, cellulose and hemicellulose and gain further molecular level insights into the interactions between the cyclic amines and biomass polymers that promote efficient solubilization and extraction. These analyses indicated that 1-piperazineethanmaine and 1-methylimidazole make noncovalent van der Waals, electrostatic interactions and hydrogen bonding with lignin, leading to enhanced lignin removal, while the strong intramolecular hydrogen bonding interactions in cellulose and hemicellulose result in weaker solvent-biopolymer interactions. Overall, the computational approach provided an efficient method for identifying cyclic amines tailored for optimal biomass pretreatment and resulted in the identification of a potential new class of solvents for effective biomass pretreatment.

Kumar, Nikhil↗

Rapid water dynamics structures the OH-stretching spectra of solitary water in ionic liquids and dipolar solvents

In a recent study [J. Phys. Chem. B 126, 4584–4598 (2022)], we have used infrared spectroscopy to investigate the solvation and dynamics of solitary water in ionic liquids and dipolar solvents. Complex shapes observed for water OH-stretching bands, common to all high-polarity solvents, were assigned to water in several solvation states. Here, in the present study, classical molecular dynamics simulations of a single water molecule in four ionic liquids and three dipolar solvents were used to test and refine this interpretation. Consistent with past assignments, simulations show solitary water usually donates two hydrogen bonds to distinct solvent molecules. Such symmetrically solvated water produces the primary pair of peaks identified in the OH spectra of water in nearly all solvents. We had further proposed that additional features flanking this main peak are due to asymmetric solvation states, states in which only one OH group makes a hydrogen bond to solvent. Such states were found in significant concentrations in all of the systems simulated. Simulations of the OH stretching spectra using a semiclassical description and the vibrational map developed by Auer and Skinner [J. Chem. Phys. 128, 224511–224512 (2008)] provided semi-quantitative agreement with experiment. Analysis of species-specific spectra confirmed assignment of the additional features in the experimental spectra to asymmetrically solvated water. The simulations also showed that rapid water motions cause a marked motional narrowing compared with the inhomogeneous limit. This narrowing is largely responsible for making the additional features due to minority solvation states manifest in the spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electric-Field-Induced Spatially Dynamic Heterogeneity of Solvent Motion and Cation Transference in Electrolytes

While electric fields primarily result in migration of charged species in electrolytic solutions, the solutions are dynamically heterogeneous. Solvent molecules within the solvation shells of the cation will be dragged by the field while free solvent molecules will not. Here we combine electrophoretic NMR measurements of ion and solvent velocities under applied electric fields with molecular dynamics simulations to interrogate different solvation motifs in a model liquid electrolyte. Measured values of the cation transference number $(t^0_+)$ agree quantitatively with simulation-based predictions over a range of electrolyte concentrations. Solvent-cation interactions strongly influence the concentration-dependent behavior of $t^0_+$. We identify a critical concentration at which most of the solvent molecules lie within solvation shells of the cations. The dynamic heterogeneity of solvent molecules is minimized at this concentration where $t^0_+$ is approximately equal to zero.

42 ENGINEERING↗

Pigment removal from reverse-printed laminated flexible films by solvent-targeted recovery and precipitation

The solvent-targeted recovery and precipitation (STRAP) process separates and recovers the constituent resins in multilayer plastic packaging films by selective polymer dissolution. In this work, the cause of coloring in the STRAP-recycled polyethylene (PE) resins from postindustrial printed films was identified as decomposed diarylide pigments. Two different approaches are needed to completely remove the dissolved colorants during the STRAP process including (i) adding an activated carbon (AC) adsorbent to the solvent after polymer dissolution and (ii) proper mechanical filtration of the polymer-solvent cake to remove as much solvent from the cake as possible. Colorless recycled PE can be produced by a combination of the proposed approaches (choosing the proper solvent, adding an AC adsorbent, and doing proper mechanical filtration) with minimal accumulation of colorants in the recycled STRAP solvents. This study demonstrated that high-quality STRAP low-density PE can be obtained from printed plastic films, enhancing the potential circularity of these packaging materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Solvent Motion on Ion Transport in Electrolytes

We use concentrated solution theory to derive an equation governing solvent velocity in a binary electrolyte when a current passes through it. This equation, in combination with the material balance equation, enables the prediction of electrolyte concentration profiles and species velocities as a function of space and time. This framework is used to predict ion velocities in Li-Li symmetric cells containing a mixture of lithium bis(trifluoromethanesulfonyl)imide and poly(ethylene oxide) (LiTFSI/PEO), for which the cation transference number relative to the solvent velocity, ${t}_{+}^{0},$ can be either positive or negative, depending on salt concentration. Accounting for the solvent motion is increasingly important at higher concentrations. Especially for negative ${t}_{+}^{0},$ if solvent velocity is set to zero, the cation velocity, based on the electrode-electrolyte interface reference frame, is pointed opposite to the current flow. However, when solvent motion is taken into account, the cation velocity, based on the same reference frame, is in the same direction as the current. This analysis demonstrates the importance of accounting for solvent velocity rigorously in seemingly simple systems such as symmetric cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solvent Hold Tank Sample Results for Mcu-12-488, Mcu-12-489, Mcu-12-490, Mcu-12-491, Mcu-12-492 And Mcu-12-493: Quarterly Sample from October 2012

Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-12-488, MCU-12-489, MCU-12-490, MCU-12-491, MCU-12-492 and MCU-12-493 received 24 October 2012 are reported. The results show that the solvent at MCU does not require an Isopar® L addition, but it will require addition of trioctylamine. SRNL also analyzed the SHT sample for 137 Cs content and determined the measured value is within tolerance but is trending upward compared to the 137 Cs measurement made last year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Solvent Hold Tank Sample Results for MCU-13-143, MCU-13-144, MCU-13-145, MCU-13-146, MCU-13-147 AND MCU-13-148: Quarterly Sample from January 2013

Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-143, MCU-13-144, MCU-13-145, MCU-13-146, MCU-13-147 and MCU-13-148 received 29 January 2012 are reported. The results show that the solvent at MCU does not require an Isopar® L addition, but it will require addition of trioctylamine. SRNL also analyzed the SHT sample for 137 Cs content and determined the measured value is within tolerance and the value has returned to levels observed in 2012.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results From The Salt Disposition Project Next Generation Solvent Demonstration Plan

Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), Caustic Wash Tank (CWT) and Solvent Hold Tank (SHT) samples were taken throughout the Next Generation Solvent (NGS) Demonstration Plan. These samples were analyzed and the results are reported. SHT: The solvent behaved as expected, with no bulk changes in the composition over time, with the exception of the TOA and TiDG. The TiDG depletion is higher than expected, and consideration must be taken on the required rate of replenishment. Monthly sampling of the SHT is warranted. If possible, additional SHT samples for TiDG analysis (only) would help SRNL refine the TiDG degradation model. CWT: The CWT samples show the expected behavior in terms of bulk chemistry. The 137Cs deposited into the CWT varies somewhat, but generally appears to be lower than during operations with the BOBCalix solvent. While a few minor organic components were noted to be present in the Preliminary sample, at this time these are thought to be artifacts of the sample preparation or may be due to the preceding solvent superwash. DSSHT: The DSSHT samples show the predicted bulk chemistry, although they point towards significant dilution at the front end of the Demonstration. The 137Cs levels in the DSSHT are much lower than during the BOBCalix operations, which is the expected observation. SEHT: The SEHT samples represent the most different output of all four of the outputs from MCU. While the bulk chemistry is as expected, something is causing the pH of the SEHT to be higher than what would be predicted from a pure stream of 0.01 M boric acid. There are several possible different reasons for this, and SRNL is in the process of investigating. Other than the pH issue, the SEHT is as predicted. In summary, the NGS Demonstration Plan samples indicate that the MCU system, with the Blend Solvent, is operating as expected. The only issue of concern regards the pH of the SEHT, and SRNL is in the process of investigating this. SRNL results support the transition to routine operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimized Solvent for Energy-Efficient, Environmentally-Friendly Capture of CO{sub 2} at Coal-Fired Power Plants

The overall goal of this project, as originally proposed, was to optimize the formulation of a novel solvent as a critical enabler for the cost-effective, energy-efficient, environmentally-friendly capture of CO{sub 2} at coal-fired utility plants. Aqueous blends of concentrated piperazine (PZ) with other compounds had been shown to exhibit high rates of CO{sub 2} absorption, low regeneration energy, and other desirable performance characteristics during an earlier 5-year development program conducted by B&W. The specific objective of this project was to identify PZ-based solvent formulations that globally optimize the performance of coal-fired power plants equipped with CO{sub 2} scrubbing systems. While previous solvent development studies have tended to focus on energy consumption and absorber size, important issues to be sure, the current work seeks to explore, understand, and optimize solvent formulation across the full gamut of issues related to commercial application of the technology: capital and operating costs, operability, reliability, environmental, health and safety (EH&S), etc. Work on the project was intended to be performed under four budget periods. The objective of the work in the first budget period has been to identify several candidate formulations of a concentrated PZ-based solvent for detailed characterization and evaluation. Work in the second budget period would generate reliable and comprehensive property and performance data for the identified formulations. Work in the third budget period would quantify the expected performance of the selected formulations in a commercial CO{sub 2} scrubbing process. Finally, work in the fourth budget period would provide a final technology feasibility study and a preliminary technology EH&S assessment. Due to other business priorities, however, B&W has requested that this project be terminated at the end of the first budget period. This document therefore serves as the final report for this project. It is the first volume of the two-volume final report and summarizes Budget Period 1 accomplishments under Tasks 1-5 of the project, including the selection of four solvent formulations for further study.

20 FOSSIL-FUELED POWER PLANTS↗

Initiate test loop irradiations of ALSEP process solvent

This report describes the initial results of the study of the impacts of gamma radiolysis upon the efficacy of the ALSEP process and is written in completion of milestone M3FT-14IN030202. Initial irradiations, up to 100 kGy absorbed dose, of the extraction section of the ALSEP process have been completed. The organic solvent used for these experiments contained 0.05 M TODGA and 0.75 M HEH[EHP] dissolved in n-dodecane. The ALSEP solvent was irradiated while in contact with 3 M nitric acid and the solutions were sparged with compressed air in order to maintain aerated conditions. The irradiated phases were used for the determination of americium and europium distribution ratios as a function of absorbed dose for the extraction and stripping conditions. Analysis of the irradiated phases in order to determine solvent composition as a function of absorbed dose is ongoing. Unfortunately, the failure of analytical equipment necessary for the analysis of the irradiated samples has made the consistent interpretation of the analytical results difficult. Continuing work will include study of the impacts of gamma radiolysis upon the extraction of actinides and lanthanides by the ALSEP solvent and the stripping of the extracted metals from the loaded solvent. The irradiated aqueous and organic phases will be analyzed in order to determine the variation in concentration of solvent components with absorbed gamma dose. Where possible, radiolysis degradation product will be identified.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Low-Energy Solvents For Carbon Dioxide Capture Enabled By A Combination Of Enzymes And Vacuum Regeneration

An integrated bench-scale system combining the attributes of the bio-renewable enzyme carbonic anhydrase (CA) with low-enthalpy CO 2 absorption solvents and vacuum regeneration was designed, built and operated for 500 hours using simulated flue gas. The objective was to develop a CO 2 capture process with improved efficiency and sustainability when compared to NETL Case 10 monoethanolamine (MEA) scrubbing technology. The use of CA accelerates inter-conversion between dissolved CO 2 and bicarbonate ion to enhance CO 2 absorption, and the use of low enthalpy CO 2 absorption solvents makes it possible to regenerate the solvent at lower temperatures relative to the reference MEA-based solvent. The vacuum regeneration-based integrated bench-scale system operated successfully for an accumulated 500 hours using aqueous 23.5 wt% K 2 CO 3 -based solvent containing 2.5 g/L enzyme to deliver an average 84% CO 2 capture when operated with a 20% enzyme replenishment rate per ~7 hour steady-state run period. The total inlet gas flow was 30 standard liters per minute with 15% CO 2 and 85% N 2 . The absorber temperature was 40°C and the stripper operated under 35 kPa pressure with an approximate 77°C stripper bottom temperature. Tests with a 30°C absorber temperature delivered >90% capture. On- and off-line operational measurements provided a full process data set, with recirculating enzyme, that allowed for enzyme replenishment and absorption/desorption kinetic parameter calculations. Dissolved enzyme replenishment and conventional process controls were demonstrated as straightforward approaches to maintain system performance. Preliminary evaluation of a novel flow-through ultrasonically enhanced regeneration system was also conducted, yet resulted in CO2 release within the range of temperature-dependent release, and further work would be needed to validate the benefits of ultrasonic enhanced stripping. A full technology assessment was completed in which four techno-economic cases for enzyme-enhanced aqueous K 2 CO 3 solvent with vacuum stripping were considered and a corresponding set of sensitivity studies were developed. The cases were evaluated using bench-scale and laboratory-based observations, AspenPlus® process simulation and modeling, AspenTech’s CCE® Parametric Software, current vendor quotations, and project partners’ know-how of unit operations. Overall, the DOE target of 90% CO 2 capture could be met using the benign enzyme-enhanced aqueous K 2 CO 3 -based alternative to NETL Case 10. The model-predicted plant COE performance, scaled to 550 MWe net output, was 9% higher than NETL Case 10 for an enzyme-activated case with minimized technical risk and highest confidence in physical system performance utilizing commercially available equipment. A COE improvement of 2.8% versus NETL Case 10 was predicted when favorable features of improved enzyme longevity and additional power output from a very low pressure (VLP) turbine were combined, wherein corresponding high capital and operational costs limited the level of COE benefit. The environmental, health and safety (EH&S) profile of the system was found to be favorable and was compliant with the Federal EH&S legislation reviewed. Further work on a larger scale test unit is recommended to reduce the level of uncertainty inherent in extrapolating findings from a bench-scale unit to a full scale PCC plant, and to further investigate several identified opportunities for improvement. Production feasibility and suitability of carbonic anhydrases for scale-up testing was confirmed both through the current project and through parallel efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ION Advanced Solvent CO 2 Capture Pilot Project

This final report to DOE/NETL presents all the work and tests performed during ION Engineering’s (ION) carbon dioxide (CO 2 ) capture pilot test campaign: “ION Advanced Solvent CO 2 Capture Project”. This project is comprised of three budget periods (BP): BP1 – Design of a 0.6 MWe system, BP2 – 0.5 MWe National Carbon Capture Center (NCCC) Testing Campaign, and BP3 – 12 MWe Technology Center at Mongstad (TCM) Testing Campaign. The program began in October 2013 and continued until December 2017. The campaign at NCCC, which took place from June to August of 2015, resulted in 1,116 operational hours where ~350 tonnes of CO 2 were captured from the 0.5 MWe coal-fired flue gas slipstream. The follow-up campaign at TCM took place from Oct 2016 to April 2017, where 2,775 hours of operation resulted in the capture of 14,820 tonnes of CO 2 , which is a cumulative of capturing CO 2 from the natural gas-fired Combined Heat and Power (CHP) plant, and a residue fluid catalytic cracker gas (RFCC) from Statoil at Mongstad. ION has conducted a thoughtful, comprehensive, and successful program in close collaboration with all its partners. CO 2 was successfully removed and captured for extended periods of time using three gas sources (NCCC Coal-fired Power plant, TCM CHP flue gas with and without CO 2 recycle, and TCM RFCC flue gas with air dilution) at various slipstream flows ranging from 0.5 MWe to 12 MWe. The data gathered on its solvent continues to strengthen the development of ION’s advanced solvent and positive track record in executing on-site test campaigns in highly industrialized settings. These existing pilot plants do not include the necessary process modifications that ION requires to obtain the lowest possible regeneration energy; processes such as a cold-rich bypass and intercooling, would allow for lowering the demonstrated specific reboiler duty. The resulting data was also used to validate the process model, and, in the absence of testing on a custom test rig specifically designed for ION’s advanced solvent, the results of the process model have shown specific reboiler duties under 2.5 MJ/kg CO 2 (1075 BTU/lb CO 2 ). When these regeneration energies are factored into the Techno-Economic Analysis (TEA), where ION’s technology is compared to the DOE/NETL BBS Case 12, which integrates a highly optimized and commercially available CO 2 capture technology, ION’s technology shows: 38% incremental reduction in capital cost of CO 2 capture; 28% incremental reduction in annual operating and maintenance costs of CO 2 capture; and $35-44 per tonne of CO 2 capture, which is a 20% to 40% reduction in cost of CO 2 capture. Throughout pilot testing, ION has confirmed its understanding of process improvements and analytics that will enable successful operation of its advanced solvent at significantly lower L/G circulation rates, packing heights and regeneration energies than MEA. ION has identified routes to further develop its technology and is looking forward to testing a fully optimized solvent and capture system in the near future.

01 COAL, LIGNITE, AND PEAT↗

Solvent Hold Tank Sample Results for MCU-18-425- 427 (October 2018), MCU-18-459-460-461 (November 2018), and MCU-18-487-488-489 (December 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples MCU-18-425-426-427, MCU-18- 459-460-461 and MCU-18-487-488-489 are reported. Most of the conclusions are based on the December SHT sample (MCU-18-487-488-489). Analyses of the December SHT sample (MCU-18-487-488-489 indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 2% and 9% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the October 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing (from May through November 2018) to 528 mg/L, but it is above the minimum recommended concentration (479 mg/L). These new levels are consistent with the concentrations observed when MCU was fully operational in 2016. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected presence of phthalates at a few ppm. The impurity concentration was highest in the October sample and consistently detected in the November and December samples (but always a few ppm or less). Another impurity observed in the samples was mercury. Based on the December SHT sample, up to 24 ± 5 micrograms of mercury per mL of solvent was detected (as the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10. The gamma concentration (~3.6E5 dpm/mL) measured in the December SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) but it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to an Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-19-366- 367-368 (April 2019), MCU-19-469-470-471 (May 2019), MCU-19-524-525-526 (June 2019): Quarterly Report

A trend summary of three sets of Solvent Hold Tank (SHT) monthly samples MCU-19-366-367-368 (April), MCU-19-469-470-471 (May), and MCU-19-524-525-526 (June) are reported. Most of the conclusions are based on the June SHT sample (MCU-19-524-525-526). Analyses of the June SHT sample (MCU-19-524- 525-526) indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L respectively) by 4% and 2% respectively but consistent with previously observed levels during normal runs. The Suppressor (N,N’,N”– tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the March 2019 measurement to 793 mg/L, which is above the minimum recommended concentration (479 mg/L). The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected presence of phthalates at a few ppm. The impurity concentration was highest in the April sample and consistently detected in the May and June samples (but always registered as a few ppm or less). Another impurity observed in the samples was mercury. Based on the June SHT sample, up to 25 ± 5 micrograms of mercury per mL of solvent was detected (as the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10. The gamma concentration (~2.90E4 dpm/mL) measured in the June 2019 SHT samples was consistent with previous values observed when the Modular Caustic-Side Solvent Extraction Unit (MCU) was operating continuously (for example, between December 2016 and January 2017). Statistical analysis of the different analytical methods detected a bias between the FT-HNMR and the High Performance Liquid Chromatography (HPLC) methods when measuring the MaxCalix and Modifier concentrations; the FT-HNMR gave a higher concentration possibly due to peak overlapping in the measured data. A bias was detected when measuring total mercury by the DMA method versus the XRF method with the XRF method reported higher mercury concentrations. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-19-569-571 (December 2019), MCU-20-1-28 (January 2020), and MCU-20-29-30-31 (June 2020) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples MCU-19-569-570-571 (December 2019), MCU-20-1-28 (January 2020), and MCU-20-29-30-31 (June 2020) are reported. Most of the conclusions are based on the June 2020 SHT sample (MCU-20-29-30-31). Analyses of the June 2020 SHT sample indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were above their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L respectively) by 6% and 7% respectively. The Suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has remained at 833 ± 16 mg/L, but it is above the minimum recommended concentration (479 mg/L). The Semi-Volatile Organic Analysis (SVOA) and FT-HNMR did not detect any organic impurities. Another impurity observed in the samples was mercury. Based on the June 2020 SHT sample, up to 23 ± 5 micrograms of mercury per gram of solvent (or 19 ± 4 mg/L) was detected. The mercury concentration steadily decreased from 34.8 ug/g solvent (or 21.9 mg/L) in the December 2019 SHT sample to 34.8 ug/g solvent (or 19 mg/L) in the June 2020 SHT sample. The gamma concentration (~3.33E4 dpm/mL) measured in the June 2020 SHT samples was consistent with previous values observed when MCU was idle (for example, between February 2017 and August 2017). If additional SHT samples become available, the laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Transformational Solvents for CO2 Separations

The primary objective of this CRADA activity is to use a combined molecular modeling and experimental validation approach to refine and develop transformational solvents for carbon capture. PNNL’s role on this project is currently funded by the Department of Energy’s (DOE) Office of Fossil Energy (OFE). PNNL is developing advanced molecular modeling based on their CO2BOLs solvent platform as a demonstration solvent for the activity; the model was developed and compared against measured data for CO2BOL derivatives. Here, a CRADA with PNNL and GE will leverage their current molecular models and apply them to solvent classes that operate on carbamate chemistry, specifically GE’s aminosilicone solvent class. The molecular models will be used to predict physical and thermodynamic properties, such as viscosity, as a means to predict advanced formulations with reduced viscosity compared to current aminosilicone derivatives, enabling optimized thermodynamic and kinetic metrics for economical carbon capture for this class of materials. Together, PNNL and GE will develop a comprehensive means of linking molecular modeling parameters to intermediate physical properties as a means to improve solvent performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗